Performance of large-scale 6Li-doped pulse-shape discriminating plastic scintillators
Authors:
C. Roca,
N. S. Bowden,
L. Carman,
S. A. Dazeley,
S. R. Durham,
O. M. Falana,
M. J. Ford,
A. M. Glenn,
C. Hurlbut,
V. A. Li,
M. P. Mendenhall,
K. Shipp,
F. Sutanto,
N. P. Zaitseva
Abstract:
A $^6$Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ-299-50, has been developed and produced at the kilogram-scale. A total of 44 kg-scale bars of dimensions 5.5 cm $\times$ 5.5 cm $\times$ 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable…
▽ More
A $^6$Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ-299-50, has been developed and produced at the kilogram-scale. A total of 44 kg-scale bars of dimensions 5.5 cm $\times$ 5.5 cm $\times$ 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable to $^6$Li-doped liquid scintillators. The scintillator EJ-299-50 shows good neutron detection capabilities with an effective efficiency for capture on $^6$Li of approximately 85%. Stability tests performed on two formulation variations showed no intrinsic degradation in the material or optical properties during several months of observations.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
PMT signal increase using a wavelength shifting paint
Authors:
K. Allada,
Ch. Hurlbut,
L. Ou,
B. Schmookler,
A. Shahinyan,
B. Wojtsekhowski
Abstract:
We report a 1.65 times increase of the PMT signal and a simple procedure of application of a new wavelength shifting (WLS) paint for PMTs with non-UV-transparent windows. Samples of four different WLS paints, made from hydrocarbon polymers and organic fluors, were tested on a 5-inch PMT (ET 9390KB) using Cherenkov radiation produced in fused silica disks by $^{106}$Ru electrons on a `table-top' se…
▽ More
We report a 1.65 times increase of the PMT signal and a simple procedure of application of a new wavelength shifting (WLS) paint for PMTs with non-UV-transparent windows. Samples of four different WLS paints, made from hydrocarbon polymers and organic fluors, were tested on a 5-inch PMT (ET 9390KB) using Cherenkov radiation produced in fused silica disks by $^{106}$Ru electrons on a `table-top' setup. The best performing paint was employed on two different types of 5-inch PMTs (ET 9390KB and XP4572B), installed in atmospheric pressure CO$_2$ gas Cherenkov detectors, and tested using GeV electrons.
△ Less
Submitted 5 February, 2015;