Beam Commissioning Results from the CBETA Fractional Arc Test
Authors:
C. Gulliford,
N. Banerjee,
A. Bartnik,
J. S. Berg,
J. Crittenden,
J. Dobbins,
R. Hulsart,
J. Jones,
D. J. Kelliher,
B. Kuske,
W. Lou,
M. McAteer,
R. Michnoff,
S. Peggs,
P. Quigley,
D. Sagan,
K. Smolenski,
V. Vesherevich,
D. Widger,
G. H. Hoffstaetter,
D. Trbojevic
Abstract:
This work describes first commissioning results from the Cornell Brookhaven Energy Recovery Test Accelerator Fractional Arc Test. These include the recommissioning of the Cornell photo-injector, the first full energy operation of the main linac with beam, as well as commissioning of the lowest energy matching beamline (splitter) and a partial section of the Fixed Field Alternating gradient (FFA) r…
▽ More
This work describes first commissioning results from the Cornell Brookhaven Energy Recovery Test Accelerator Fractional Arc Test. These include the recommissioning of the Cornell photo-injector, the first full energy operation of the main linac with beam, as well as commissioning of the lowest energy matching beamline (splitter) and a partial section of the Fixed Field Alternating gradient (FFA) return loop featuring first production Halbach style permanent magnets. Achieving these tasks required characterization of the injection beam, calibration and phasing of the main linac cavities, demonstration of the required 36 MeV energy gain, and measurement of the splitter line horizontal dispersion and R56 at the nominal 42 MeV. In addition, a procedure for determining the BPM offsets, as well as the tune per cell in the FFA section via scanning the linac energy and inducing betatron oscillations around the periodic orbit in the fractional arc was developed and tested. A detailed comparison of these measurements to simulation is discussed.
△ Less
Submitted 11 February, 2019; v1 submitted 8 February, 2019;
originally announced February 2019.
-
Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets
Authors:
P. Thieberger,
D. Gassner,
R. Hulsart,
R. Michnoff,
T. Miller,
M. Minty,
Z. Sorrell,
A. Bartnik
Abstract:
A simple, analytically correct algorithm is developed for calculating pencil beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correct…
▽ More
A simple, analytically correct algorithm is developed for calculating pencil beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then used to study the impact of beam-size upon the precision of BPMs in the non-linear region. As an example of the data acquisition speed advantage, a FPGA-based BPM readout implementation of the new algorithm has been developed and characterized. Finally,the algorithm is tested with BPM data from the Cornell Preinjector.
△ Less
Submitted 24 March, 2018; v1 submitted 21 November, 2017;
originally announced November 2017.
-
Status of head-on beam-beam compensation in RHIC
Authors:
W. Fischer,
Z. Altinbas,
M. Anerella,
M. Blaskiewicz,
D. Bruno,
M. Costanzo,
W. C. Dawson,
D. M. Gassner,
X. Gu,
R. C. Gupta,
K. Hamdi,
J. Hock,
L. T. Hoff,
R. Hulsart,
A. K. Jain,
R. Lambiase,
Y. Luo,
M. Mapes,
A. Marone,
R. Michnoff,
T. A. Miller,
M. Minty,
C. Montag,
J. Muratore,
S. Nemesure
, et al. (12 additional authors not shown)
Abstract:
In polarized proton operation, the performance of the Relativistic Heavy Ion Collider (RHIC) is limited by the head-on beam-beam effect. To overcome this limitation, two electron lenses are under commissioning. We give an overview of head-on beam-beam compensation in general and in the specific design for RHIC, which is based on electron lenses. The status of installation and commissioning are pre…
▽ More
In polarized proton operation, the performance of the Relativistic Heavy Ion Collider (RHIC) is limited by the head-on beam-beam effect. To overcome this limitation, two electron lenses are under commissioning. We give an overview of head-on beam-beam compensation in general and in the specific design for RHIC, which is based on electron lenses. The status of installation and commissioning are presented along with plans for the future.
△ Less
Submitted 20 October, 2014;
originally announced October 2014.