-
Ground calibration of Gamma-Ray Detectors of GECAM-C
Authors:
Chao Zheng,
Zheng-Hua An,
Wen-Xi Peng,
Da-Li Zhang,
Shao-Lin Xiong,
Rui. Qiao,
Yan-Qiu Zhang,
Wang-Chen Xue,
Jia-Cong Liu,
Pei-Yi Feng,
Ce. Cai,
Min Gao,
Ke Gong,
Dong-Ya Guo,
Dong-Jie Hou,
Gang Li,
Xin-Qiao Li,
Yan-Guo Li,
Mao-Shun Li,
Xiao-Hua Liang,
Ya-Qing Liu,
Xiao-**g Liu,
Li-Ming Song,
Xi-Lei Sun,
Wen-Jun Tan
, et al. (13 additional authors not shown)
Abstract:
As a new member of GECAM mission, GECAM-C (also named High Energy Burst Searcher, HEBS) was launched onboard the SATech-01 satellite on July 27th, 2022, which is capable to monitor gamma-ray transients from $\sim$ 6 keV to 6 MeV. As the main detector, there are 12 gamma-ray detectors (GRDs) equipped for GECAM-C. In order to verify the GECAM-C GRD detector performance and to validate the Monte Carl…
▽ More
As a new member of GECAM mission, GECAM-C (also named High Energy Burst Searcher, HEBS) was launched onboard the SATech-01 satellite on July 27th, 2022, which is capable to monitor gamma-ray transients from $\sim$ 6 keV to 6 MeV. As the main detector, there are 12 gamma-ray detectors (GRDs) equipped for GECAM-C. In order to verify the GECAM-C GRD detector performance and to validate the Monte Carlo simulations of detector response, comprehensive on-ground calibration experiments have been performed using X-ray beam and radioactive sources, including Energy-Channel relation, energy resolution, detection efficiency, SiPM voltage-gain relation and the non-uniformity of positional response. In this paper, the detailed calibration campaigns and data analysis results for GECAM-C GRDs are presented, demonstrating the excellent performance of GECAM-C GRD detectors.
△ Less
Submitted 30 May, 2023; v1 submitted 1 March, 2023;
originally announced March 2023.
-
The performance of SiPM-based gamma-ray detector (GRD) of GECAM-C
Authors:
Dali Zhang,
Chao Zheng,
Jiacong Liu,
Zhenghua An,
Chenwei Wang,
Xiangyang Wen,
Xinqiao Li,
Xilei Sun,
Ke Gong,
Yaqing Liu,
Xiao**g Liu,
Sheng Yang,
Wenxi Peng,
Rui Qiao,
Dongya Guo,
Peiyi Feng,
Yanqiu Zhang,
Wangchen Xue,
Wenjun Tan,
Ce Cai,
Shuo Xiao,
Qibin Yi,
Yanbing Xu,
Min Gao,
**zhou Wang
, et al. (20 additional authors not shown)
Abstract:
As a new member of GECAM mission, the GECAM-C (also called High Energy Burst Searcher, HEBS) is a gamma-ray all-sky monitor onboard SATech-01 satellite, which was launched on July 27th, 2022 to detect gamma-ray transients from 6 keV to 6 MeV, such as Gamma-Ray Bursts (GRBs), high energy counterpart of Gravitational Waves (GWs) and Fast Radio Bursts (FRBs), and Soft Gamma-ray Repeaters (SGRs). Toge…
▽ More
As a new member of GECAM mission, the GECAM-C (also called High Energy Burst Searcher, HEBS) is a gamma-ray all-sky monitor onboard SATech-01 satellite, which was launched on July 27th, 2022 to detect gamma-ray transients from 6 keV to 6 MeV, such as Gamma-Ray Bursts (GRBs), high energy counterpart of Gravitational Waves (GWs) and Fast Radio Bursts (FRBs), and Soft Gamma-ray Repeaters (SGRs). Together with GECAM-A and GECAM-B launched in December 2020, GECAM-C will greatly improve the monitoring coverage, localization, as well as temporal and spectral measurements of gamma-ray transients. GECAM-C employs 12 SiPM-based Gamma-Ray Detectors (GRDs) to detect gamma-ray transients . In this paper, we firstly give a brief description of the design of GECAM-C GRDs, and then focus on the on-ground tests and in-flight performance of GRDs. We also did the comparison study of the SiPM in-flight performance between GECAM-C and GECAM-B. The results show GECAM-C GRD works as expected and is ready to make scientific observations.
△ Less
Submitted 7 March, 2023; v1 submitted 1 March, 2023;
originally announced March 2023.
-
The Design and Performance of Charged Particle Detector onboard the GECAM Mission
Authors:
Y. B. Xu,
X. L. Sun,
S. Yang,
X. Q. Li,
W. X. Peng,
K. Gong,
X. H. Liang,
Y. Q. Liu,
D. Y. Guo,
H. Wang,
C. Y. Li,
Z. H. An,
J. J. He,
X. J. Liu,
S. L. Xiong,
X. Y. Wen,
Fan Zhang,
D. L. Zhang,
X. Y. Zhao,
C. Y. Zhang,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du
, et al. (25 additional authors not shown)
Abstract:
The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new radiation phenomena. GECAM consists of two microsatellites, each equipped with 8 charged particle detectors (CPDs) and 25 gamma-ray detectors (GRDs). The CPD is us…
▽ More
The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new radiation phenomena. GECAM consists of two microsatellites, each equipped with 8 charged particle detectors (CPDs) and 25 gamma-ray detectors (GRDs). The CPD is used to measure charged particles in the space environment, monitor energy and flow intensity changes, and identify between gamma-ray bursts and space charged particle events in conjunction with GRD. CPD uses plastic scintillator as the sensitive material for detection, silicon photomultiplier (SiPM) array as the optically readable device, and the inlaid Am-241 radioactive source as the onboard calibration means. In this paper, we will present the working principle, physical design, functional implementation and preliminary performance test results of the CPD.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Inflight performance of the GECAM Gamma-ray and Charge particle Detectors
Authors:
X. Q. Li,
X. Y. Wen,
S. L. Xiong,
K. Gong,
D. L. Zhang,
Z. H. An,
Y. B. Xu,
Y. Q. Liu,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du,
M. Gao,
R. Gao,
D. Y. Guo,
J. J. He,
D. J. Hou,
Y. G. Li,
C. Li,
C. Y. Li,
G. Li,
L. Li,
Q. X. Li,
X. F. Li
, et al. (34 additional authors not shown)
Abstract:
The GECAM mission consists of two identical microsatellites (GECAM-A and GECAM-B). Each satellite is equipped with 25 gamma-ray detectors (GRD) and 8 charged particle detectors (CPD). The main scientific objective of the GECAM mission is to detect gamma-ray bursts (GRBs) associated with the gravitational wave events produced by the merging of binary compact stars. After the launch on Dec. 10, 2020…
▽ More
The GECAM mission consists of two identical microsatellites (GECAM-A and GECAM-B). Each satellite is equipped with 25 gamma-ray detectors (GRD) and 8 charged particle detectors (CPD). The main scientific objective of the GECAM mission is to detect gamma-ray bursts (GRBs) associated with the gravitational wave events produced by the merging of binary compact stars. After the launch on Dec. 10, 2020 , we carried out a series of on orbit tests. This paper introduces the test results of the GECAM-B satellite. According to the in-flight performance, the energy band for gamma-ray detection of GECAM-B is from about 7 keV to 3.5 MeV. GECAM-B can achieve prompt localization of GRBs. For the first time, GECAM-B realized a quasi-real-time transmission of trigger information using Beidou-3 RDSS. Keywords GECAM, gamma-ray burst, gravitational wave, GRD, CPD
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Performance of a focal plane detector for soft X-ray imaging spectroscopy based on back-illuminated sCMOS
Authors:
Can Chen,
Yusa Wang,
Yupeng Xu,
Zijian Zhao,
Hongyun Qiu,
Dongjie Hou,
Xiongtao Yang,
Jia Ma,
Yong Chen,
Yang Zhao,
Hua Liu,
Xiaofan Zhao,
Yuxuan Zhu
Abstract:
Spectroscopy focusing array (SFA) and Polarimetry focusing array (PFA) are the two major payloads of enhanced X-ray Timing and Polarimetry mission (eXTP). Nested Wolter-\RNum{1} X-ray mirror module is implemented in SFA and PFA to achive high effective area. When evaluating the properties of the mirror module, the alignment of the optical axis of the X-ray mirror module and a quasi-parallel X-ray…
▽ More
Spectroscopy focusing array (SFA) and Polarimetry focusing array (PFA) are the two major payloads of enhanced X-ray Timing and Polarimetry mission (eXTP). Nested Wolter-\RNum{1} X-ray mirror module is implemented in SFA and PFA to achive high effective area. When evaluating the properties of the mirror module, the alignment of the optical axis of the X-ray mirror module and a quasi-parallel X-ray beam is a prerequisite to ensure the accuracy of the results. Hence, to assist the alignment of the X-ray mirror module, an X-ray focal plane detector is designed based on the back-illuminated scientific Complementary Metal-Oxide-Semiconductor Transistor (sCMOS) sensor GSENSE6060BSI, one of the largest detection areas, is produced by \textit{Gpixel Inc}. Then the characteristics of readout noise, dark current, and split-pixel event properties of the detector are studied with the self-developed multi-target fluorescence X-ray source in a 100 m long X-ray test facility. The energy calibration is carried out with the single-pixel event and the energy non-linearity of the detector is also obtained. Eventually, the simulation of the eXTP mirror module based on the optical model is conducted and the alignment test of the Wolter-\RNum{1} X-ray mirror module designed for \textit{EP/FXT} (Einstein Probe/Follow-up X-ray Telescope) with "Burkert test" method is shown.
△ Less
Submitted 22 November, 2021;
originally announced November 2021.
-
The new MRTOF mass spectrograph following the ZeroDegree spectrometer at RIKEN's RIBF facility
Authors:
M. Rosenbusch,
M. Wada,
S. Chen,
A. Takamine,
S. Iimura,
D. Hou,
W. Xian,
S. Yan,
P. Schury,
Y. Hirayama,
Y. Ito,
H. Ishiyama,
S. Kimura,
T. Kojima,
J. Lee,
J. Liu,
S. Michimasa,
H. Miyatake,
M. Mukai,
J. Y. Moon,
S. Nishimura,
S. Naimi,
T. Niwase,
T. Sonoda,
Y. X. Watanabe
, et al. (1 additional authors not shown)
Abstract:
A newly assembled multi-reflection time-of-flight mass spectrograph (MRTOF-MS) at RIKEN's RIBF facility became operational for the first time in spring 2020; further modifications and performance tests using stable ions were completed in early 2021. By using a pulsed-drift-tube technique to modify the ions' kinetic energy in a wide range, we directly characterize the dispersion function of the sys…
▽ More
A newly assembled multi-reflection time-of-flight mass spectrograph (MRTOF-MS) at RIKEN's RIBF facility became operational for the first time in spring 2020; further modifications and performance tests using stable ions were completed in early 2021. By using a pulsed-drift-tube technique to modify the ions' kinetic energy in a wide range, we directly characterize the dispersion function of the system for use in a new procedure for optimizing the voltages applied to the electrostatic mirrors. Thus far, a mass resolving power of $R_m > 1\,000\,000$ is reached within a total time-of-flight of only $12.5\,\mathrm{ms}$, making the spectrometer capable of studying short-lived nuclei possessing low-lying isomers. Detailed information about the setup and measurement procedure is reported, and an alternative in-MRTOF ion selection scheme to remove molecular contaminants in the absence of a dedicated deflection device is introduced. The setup underwent an initial on-line commissioning at the BigRIPS facility at the end of 2020, where more than 70 nuclear masses have been measured. A summary of the commissioning experiments and results from a test of mass accuracy will be presented.
△ Less
Submitted 2 November, 2022; v1 submitted 22 October, 2021;
originally announced October 2021.
-
Gain stabilization and consistency correction approach for multiple SiPM-based gamma-ray detectors on GECAM
Authors:
Dali Zhang,
Xinqiao Li,
Xiangyang Wen,
Shaolin Xiong,
Zhenghua An,
Xilei Sun,
Rui Qiao,
Zhengwei Li,
Ke Gong,
Dongjie Hou,
Yanguo Li,
Xiaohua Liang,
Xiao**g Liu,
Yaqing Liu,
Wenxi Peng,
Sheng Yang,
Fan Zhang,
Xiaoyun Zhao,
Ce Cai,
Chaoyang Li,
Jiacong Liu,
Shuo Xiao,
Chenwei Wang,
Qibin Yi,
Chao Zheng
Abstract:
Each satellite of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM, mission) consists of 25 SiPM based gamma-ray detectors (GRDs). Although SiPM based GRD has merits of compact size and low bias-voltage, the drift of the SiPM gain with temperature is a severe problem for GRD performance. An adaptive voltage supply source was designed to automatically adjust the…
▽ More
Each satellite of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM, mission) consists of 25 SiPM based gamma-ray detectors (GRDs). Although SiPM based GRD has merits of compact size and low bias-voltage, the drift of the SiPM gain with temperature is a severe problem for GRD performance. An adaptive voltage supply source was designed to automatically adjust the SiPM bias voltage to compensate the temperature effects and keep the gain stable. This approach has been proved to be effective during both the on-ground and in-flight tests. The in-flight measured variation of the SiPM gain is within 2%. To reduce the gain non-uniformity of GRDs, an iterative bias voltage adjustment approach is proposed and implemented. The gain non-uniformity is reduced from 17% to 0.6%. In this paper, the gain stabilization and consistency correction approach are presented and discussed in detail.
△ Less
Submitted 9 December, 2021; v1 submitted 4 October, 2021;
originally announced October 2021.
-
Quality assurance test and Failure Analysis of SiPM Arrays of GECAM Satellites
Authors:
D. L. Zhang,
M. Gao,
X. L. Sun,
X. Q. Li,
Z. H. An,
X. Y. Wen,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du,
R. Gao,
K. Gong,
D. Y. Guo,
J. J. He,
D. J. Hou,
Y. G. Li,
C. Y. Li,
G. Li,
L. Li,
X. F. Li,
M. S. Li,
X. H. Liang,
X. J. Liu,
Y. Q. Liu
, et al. (23 additional authors not shown)
Abstract:
The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) satellite consists of two small satellites. Each GECAM payload contains 25 gamma ray detectors (GRD) and 8 charged particle detectors (CPD). GRD is the main detector which can detect gamma-rays and particles and localize the Gamma-Ray Bursts (GRB),while CPD is used to help GRD to discriminate gamma-ray bursts an…
▽ More
The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) satellite consists of two small satellites. Each GECAM payload contains 25 gamma ray detectors (GRD) and 8 charged particle detectors (CPD). GRD is the main detector which can detect gamma-rays and particles and localize the Gamma-Ray Bursts (GRB),while CPD is used to help GRD to discriminate gamma-ray bursts and charged particle bursts. The GRD makes use of lanthanum bromide (LaBr3) crystal readout by SiPM. As the all available SiPM devices belong to commercial grade, quality assurance tests need to be performed in accordance with the aerospace specifications. In this paper, we present the results of quality assurance tests, especially a detailed mechanism analysis of failed devices during the development of GECAM. This paper also summarizes the application experience of commercial-grade SiPM devices in aerospace payloads, and provides suggestions for forthcoming SiPM space applications.
△ Less
Submitted 9 December, 2021; v1 submitted 1 September, 2021;
originally announced September 2021.
-
Design and test of a portable Gamma-Ray Burst simulator for GECAM
Authors:
Can Chen,
Shuo Xiao,
Shaolin Xiong,
Nian Yu,
Xiangyang Wen,
Ke Gong,
Xinqiao Li,
Chaoyang Li,
Dongjie Hou,
Xiongtao Yang,
Zijian Zhao,
Yuxuan Zhu,
Dali Zhang,
Zhenghua An,
Xiaoyun Zhao,
Yupeng Xu,
Yusa Wang
Abstract:
The main scientific goal of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is to monitor various types of Gamma-Ray Bursts (GRB) originated from merger of binary compact stars, which could also produce gravitational wave, and collapse of massive stars. In order to study the response of GECAM Gamma-Ray Detectors (GRDs) to high-energy bursts and test the in-fl…
▽ More
The main scientific goal of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is to monitor various types of Gamma-Ray Bursts (GRB) originated from merger of binary compact stars, which could also produce gravitational wave, and collapse of massive stars. In order to study the response of GECAM Gamma-Ray Detectors (GRDs) to high-energy bursts and test the in-flight trigger and localization software of GECAM before the launch, a portable GRB simulator device is designed and implemented based on grid controlled X-ray tube (GCXT) and direct digital synthesis (DDS) technologies. The design of this GRB simulator which modulates X-ray flux powered by high voltage up to 20 kV is demonstrated, and the time jitter (FWHM) of the device is about 0.9 $μ$s. Before the launch in December, 2020, both two GECAM satellites were irradiated by different types of GRBs (including short and long bursts in duration) generated by this GRB simulator. The light curves detected with GECAM/GRDs are consistent with the programmed input functions within statistical uncertainties, indicating the good performance of both the GRDs and the GRB simulator.
△ Less
Submitted 10 July, 2021; v1 submitted 26 June, 2021;
originally announced June 2021.
-
Bioinspired Materials with Self-Adaptable Mechanical Properties
Authors:
Santiago Orrego,
Zhezhi Chen,
Urszula Krekora,
Decheng Hou,
Seung-Yeol Jeon,
Matthew Pittman,
Carolina Montoya,
Yun Chen,
Sung Hoon Kang
Abstract:
Natural structural materials, such as bone and wood, can autonomously adapt their mechanical properties in response to loading to prevent failure. They smartly control the addition of material in locations of high stress by utilizing locally available resources guided by biological signals. On the contrary, synthetic structural materials have unchanging mechanical properties limiting their mechani…
▽ More
Natural structural materials, such as bone and wood, can autonomously adapt their mechanical properties in response to loading to prevent failure. They smartly control the addition of material in locations of high stress by utilizing locally available resources guided by biological signals. On the contrary, synthetic structural materials have unchanging mechanical properties limiting their mechanical performance and service life. Here, a material system that autonomously adapts its mechanical properties in response to mechanical loading is reported inspired by the mineralization process of bone. It is observed that charges from piezoelectric scaffolds can induce mineralization from media with mineral ions. The material system adapts to mechanical loading by inducing mineral deposition in proportion to the magnitude of the loading and the resulting piezoelectric charges. Moreover, the mechanism allows a simple one-step route for making graded materials by controlling stress distribution along the scaffold. The findings can pave the way for a new class of self-adaptive materials that reinforce the region of high stress or induce deposition of minerals on the damaged areas from the increase in stress to prevent/mitigate failure. They can also contribute to addressing the current challenges of synthetic materials for load-bearing applications from self-adaptive capabilities.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
Possibility to construct a clock on non 0-0 transition
Authors:
Chao Li,
Fuyu Sun,
Jie Liu,
Xiaofeng Li,
Jie Ma,
Guangkun Guo,
Dong Hou,
Shougang Zhang
Abstract:
In this letter, we discuss the possibility of non 0-0 atomic lines as the reference transitions to design a new atomic clock. The proposed clock operates in high C-field regime offering an interesting alternative to conventional clock based on 0-0 transition as the former can also eliminate the influence of the first-order Zeeman effect. Using the Breit-Rabi formula, we theoretically calculate the…
▽ More
In this letter, we discuss the possibility of non 0-0 atomic lines as the reference transitions to design a new atomic clock. The proposed clock operates in high C-field regime offering an interesting alternative to conventional clock based on 0-0 transition as the former can also eliminate the influence of the first-order Zeeman effect. Using the Breit-Rabi formula, we theoretically calculate the magnetically insensitive frequency and the corresponding C-field value for different alkali atom species. We also provide an estimate of the uncertainty of frequency shift to change of C-field. We show that a high C-field clock based on Cs: 3,-1 - 4,0, 3,0 - 4,-1, and 3,-1 - 4,-1, can achieve a bias of 10-14 with a C-field of 10-6 uncertainty. The free first-order Zeeman effect C-field for 3,-1 - 4,0 or 3,0 - 4,-1 transition is about one half that for 3,-1 - 4,-1 transition.
△ Less
Submitted 23 October, 2019;
originally announced October 2019.
-
Coherent ac spin current transmission across an antiferromagnetic CoO insulator
Authors:
Q. Li,
M. Yang,
C. Klewe,
P. Shafer,
A. T. N'Diaye,
D. Hou,
T. Y. Wang,
N. Gao,
E. Saitoh,
C. Hwang,
R. J. Hicken,
J. Li,
E. Arenholz,
Z. Q. Qiu
Abstract:
The recent discovery of spin-current transmission through antiferromagnetic (AFM) insulating materials opens up unprecedented opportunities for fundamental physics and spintronics applications. The great mystery currently surrounding this topic is: how could THz AFM magnons mediate a GHz spin current? This mis-match of frequencies becomes particularly critical for the case of coherent ac spin-curr…
▽ More
The recent discovery of spin-current transmission through antiferromagnetic (AFM) insulating materials opens up unprecedented opportunities for fundamental physics and spintronics applications. The great mystery currently surrounding this topic is: how could THz AFM magnons mediate a GHz spin current? This mis-match of frequencies becomes particularly critical for the case of coherent ac spin-current, raising the fundamental question of whether a GHz ac spin-current can ever keep its coherence inside an AFM insulator and so drive the spin precession of another FM layer coherently? Utilizing element- and time-resolved x-ray pump-probe measurements on Py/Ag/CoO/Ag/Fe75Co25/MgO(001) heterostructures, we demonstrate that a coherent GHz ac spin current pumped by the permalloy (Py) ferromagnetic resonance (FMR) can transmit coherently across an antiferromagnetic CoO insulating layer to drive a coherent spin precession of the FM Fe75Co25 layer. Further measurement results favor thermal magnons rather than evanescent spin waves as the mediator of the coherent ac spin current in CoO.
△ Less
Submitted 1 June, 2019;
originally announced June 2019.
-
Laser-based underwater transfer of radio-frequency clock signal with electronic phase compensation
Authors:
Dong Hou,
Guangkun Guo,
Danian Zhang,
Fuyu Sun
Abstract:
We demonstrate a laser-based underwater transfer of radio frequency clock signal with a phase compensation technique. With this frequency transfer scheme, a 100 MHz signal has been transferred over 5 m underwater link. Timing jitter power spectral density, timing fluctuations and instabilities were all measured to evaluate the quality of the transferred frequency signal. The experimental results s…
▽ More
We demonstrate a laser-based underwater transfer of radio frequency clock signal with a phase compensation technique. With this frequency transfer scheme, a 100 MHz signal has been transferred over 5 m underwater link. Timing jitter power spectral density, timing fluctuations and instabilities were all measured to evaluate the quality of the transferred frequency signal. The experimental results show the root-mean-square (RMS) timing fluctuations of the transferred frequency signal over 5 m underwater link with and without phase compensation are 2.1 ps and 9.6 ps within 5000 s, respectively. The relative fractional frequency instabilities are on the order of 5E-13 at 1 s and 7E-16 at 1000 s for phase-compensated link, and 2E-12 at 1 s and 7E-15 at 1000 sfor uncompensated link, respectively. The proposed frequency transfer scheme has a potential application that disseminating Cs and H-master clocks signal over the underwater transmission link since the stability of the transmission link is superior to these atomic clocks.
△ Less
Submitted 21 January, 2019;
originally announced January 2019.
-
Tunable Microwave Magnetic Field Detection based on Rabi Resonance with a Single Cesium-Rubidium Hybrid Vapor Cell
Authors:
Fuyu Sun,
Zhiyuan Jiang,
Jifeng Qu,
Zhenfei Song,
Jie Ma,
Dong Hou,
Xiaochi Liu
Abstract:
We experimentally investigated Rabi resonance-based continuously frequency-tunable microwave (MW) magnetic field detection using a single hybrid vapor cell filled with cesium and rubidium atoms. The multispecies atomic systems, with their tunable abilities in transition frequencies, enabled this atomic sensing head to cover a broader detectable MW field scope compared to the use of a single metal…
▽ More
We experimentally investigated Rabi resonance-based continuously frequency-tunable microwave (MW) magnetic field detection using a single hybrid vapor cell filled with cesium and rubidium atoms. The multispecies atomic systems, with their tunable abilities in transition frequencies, enabled this atomic sensing head to cover a broader detectable MW field scope compared to the use of a single metal atom. Here, we demonstrated the simultaneous observation of atomic Rabi resonance signals with 85Rb, 87Rb, and 133Cs in the same vapor cell. Using an experimentally feasible static magnetic field (DC field) below 500 Gauss, we realized a MW magnetic field strength detection with bandwidths of 4.8 GHz around 8.1 GHz. The use of these three atomic systems confined in a single vapor cell also enabled the establishment of an identical MW field with the help of DC field, allowing us to perform a perfect comparison for different applications that require the same electromagnetic environment. The results may be useful for the realization and application of many atomic detectors based on different physical principles.
△ Less
Submitted 6 August, 2018; v1 submitted 21 July, 2018;
originally announced July 2018.
-
Measuring magnetic field inside a microwave cavity via Rabi resonances in Cs atoms
Authors:
Fuyu Sun,
Dong Hou,
Qingsong Bai,
Xianhe Huang,
Jie Ma,
Xiaofeng Li
Abstract:
We present a technique for measuring microwave (MW) field based on Rabi resonances induced by the interaction of atoms with a phase-modulated MW field. A theoretical model of field measurement is used to calculate Rabi frequency. Single-peak feature of the measurement model makes the technique a valuable tool for simple and fast field measurement. As an example, we use the technique to determine t…
▽ More
We present a technique for measuring microwave (MW) field based on Rabi resonances induced by the interaction of atoms with a phase-modulated MW field. A theoretical model of field measurement is used to calculate Rabi frequency. Single-peak feature of the measurement model makes the technique a valuable tool for simple and fast field measurement. As an example, we use the technique to determine the MW field strength inside a Cs vapor cell in the X-band rectangular cavity for applied power in the range of -21 dBm to 20 dBm. The results show that this proposed technique is capable for detecting the field over a broad dynamical range.
△ Less
Submitted 16 May, 2017; v1 submitted 29 November, 2016;
originally announced November 2016.
-
Long-term Stabilization of Fiber Laser Using Phase-locking Technique with Ultra-low Phase Noise and Phase Drift
Authors:
Dong Hou,
Bo Ning,
Shuangyou Zhang,
Jiutao Wu,
Jianye Zhao
Abstract:
We review the conventional phase-locking technique in the long-term stabilization of the mode-locked fiber laser and investigate the phase noise limitation of the conventional technique. To break the limitation, we propose an improved phase-locking technique with an optic-microwave phase detector in achieving the ultra-low phase noise and phase drift. The mechanism and the theoretical model of the…
▽ More
We review the conventional phase-locking technique in the long-term stabilization of the mode-locked fiber laser and investigate the phase noise limitation of the conventional technique. To break the limitation, we propose an improved phase-locking technique with an optic-microwave phase detector in achieving the ultra-low phase noise and phase drift. The mechanism and the theoretical model of the novel phase-locking technique are also discussed. The long-term stabilization experiments demonstrate that the improved technique can achieve the long-term stabilization for the MLFL with ultra-low phase noise and phase drift. The excellent locking performance of the improved phase-locking technique implies that this technique can be used to stabilize the mode-locked fiber laser with the highly stable H-master or optical clock without stability loss.
△ Less
Submitted 11 March, 2014;
originally announced March 2014.
-
High-precision Distribution of Highly-stable Optical Pulse Trains with Sub-10-fs Timing Jitter
Authors:
B. Ning,
S. Y. Zhang,
D. Hou,
J. T. Wu,
Z. B. Li,
J. Y. Zhao
Abstract:
High-precision optical pulse trains distribution via fibre links has made huge impacts in many fields. In most published works, the accuracies are still fundamentally limited by some unavoidable noises, such as thermal and shot noise from conventional photodiodes, thermal noise from mixers. Here, we demonstrate a new high-precision timing distribution system by using highly-precision phase detecto…
▽ More
High-precision optical pulse trains distribution via fibre links has made huge impacts in many fields. In most published works, the accuracies are still fundamentally limited by some unavoidable noises, such as thermal and shot noise from conventional photodiodes, thermal noise from mixers. Here, we demonstrate a new high-precision timing distribution system by using highly-precision phase detector to overcome the limitations. Instead of using photodiodes and microwave mixers, we use several fibre Sagnac-loop-based optical-microwave phase detectors to realize optical-electrical conversion and phase measurements, for suppressing the noises and achieving ultra-high accuracy. A 10-km fibre link distribution experiment shows our system provides a residual instability at the level of 4.6*10-15@1-s and 6.1*10-18@10000-s, with an integrated timing jitter as low as 3.8 fs in a bandwidth of 1 Hz to 100 KHz. This low instability and timing jitter makes it possible that our system can be used in the optical clock distribution or the applications for the facilities which require extremely accuracy frequency time synchronization.
△ Less
Submitted 23 February, 2014;
originally announced February 2014.
-
Time-dependent density-functional theory for real-time electronic dynamics on material surfaces
Authors:
Rulin Wang,
Dong Hou,
Xiao Zheng
Abstract:
The real-time electronic dynamics on material surfaces is critically important to a variety of applications. However, their simulations have remained challenging for conventional methods such as the time-dependent density-functional theory (TDDFT) for isolated and periodic systems. By extending the applicability of TDDFT to systems with open boundaries, we achieve accurate atomistic simulations of…
▽ More
The real-time electronic dynamics on material surfaces is critically important to a variety of applications. However, their simulations have remained challenging for conventional methods such as the time-dependent density-functional theory (TDDFT) for isolated and periodic systems. By extending the applicability of TDDFT to systems with open boundaries, we achieve accurate atomistic simulations of real-time electronic response to local perturbations on material surfaces. Two prototypical scenarios are exemplified: the relaxation of an excess electron on graphene surface, and the electron transfer across the molecule-graphene interface. Both the transient and long-time asymptotic dynamics are validated, which accentuates the fundamental importance and unique usefulness of an open-system TDDFT approach. The simulations also provide insights into the characteristic features of temporal electron evolution and dissipation on surfaces of bulk materials.
△ Less
Submitted 22 July, 2013;
originally announced July 2013.
-
Observation of Rb Two-Photon Absorption Directly Excited by an Erbium-Fiber-Laser-Based Optical Frequency Comb via Spectral Control
Authors:
Jiutao Wu,
Dong Hou,
Xiaoliang Dai,
Zhengyu Qin,
Zhigang Zhang,
Jianye Zhao
Abstract:
We demonstrated the observation of Rb two-photon absorption directly excided by an optical frequency comb at fiber communication bands. A chain of comb spectral control is elaborately implemented to increase the power of the second harmonic optical frequency comb generation and the two-photon transition strength. A two-photon transition spectrum is obtained with clearly resolved transition lines.…
▽ More
We demonstrated the observation of Rb two-photon absorption directly excided by an optical frequency comb at fiber communication bands. A chain of comb spectral control is elaborately implemented to increase the power of the second harmonic optical frequency comb generation and the two-photon transition strength. A two-photon transition spectrum is obtained with clearly resolved transition lines. It provides a potential approach to realize the optical frequency comb or optical clock at ~1.5μm with high stability and accuracy.
△ Less
Submitted 10 June, 2013;
originally announced June 2013.