-
Increasing the rate capability for the cryogenic stop** cell of the FRS Ion Catcher
Authors:
J. W. Zhao,
D. Amanbayev,
T. Dickel,
I. Miskun,
W. R. Plass,
N. Tortorelli,
S. Ayet San Andres,
Soenke Beck,
J. Bergmann,
Z. Brencic,
P. Constantin,
H. Geissel,
F. Greiner,
L. Groef,
C. Hornung,
N. Kuzminzuk,
G. Kripko-Koncz,
I. Mardor,
I. Pohjalainen,
C. Scheidenberger,
P. G. Thirolf,
S. Bagchi,
E. Haettner,
E. Kazantseva,
D. Kostyleva
, et al. (23 additional authors not shown)
Abstract:
At the FRS Ion Catcher (FRS-IC), projectile and fission fragments are produced at relativistic energies, separated in-flight, energy-bunched, slowed down, and thermalized in the ultra-pure helium gas-filled cryogenic stop** cell (CSC). Thermalized nuclei are extracted from the CSC using a combination of DC and RF electric fields and gas flow. This CSC also serves as the prototype CSC for the Sup…
▽ More
At the FRS Ion Catcher (FRS-IC), projectile and fission fragments are produced at relativistic energies, separated in-flight, energy-bunched, slowed down, and thermalized in the ultra-pure helium gas-filled cryogenic stop** cell (CSC). Thermalized nuclei are extracted from the CSC using a combination of DC and RF electric fields and gas flow. This CSC also serves as the prototype CSC for the Super-FRS, where exotic nuclei will be produced at unprecedented rates making it possible to go towards the extremes of the nuclear chart. Therefore, it is essential to efficiently extract thermalized exotic nuclei from the CSC under high beam rate conditions, in order to use the rare exotic nuclei which come as cocktail beams. The extraction efficiency dependence on the intensity of the im**ing beam into the CSC was studied with a primary beam of 238U and its fragments. Tests were done with two different versions of the DC electrode structure inside the cryogenic chamber, the standard 1 m long and a short 0.5 m long DC electrode. In contrast to the rate capability of 10^4 ions/s with the long DC electrode, results show no extraction efficiency loss up to the rate of 2x10^5 ions/s with the new short DC electrode. This order of magnitude increase of the rate capability paves the way for new experiments at the FRS-IC, including exotic nuclei studies with in-cell multi-nucleon transfer reactions. The results further validate the design concept of the CSC for the Super-FRS, which was developed to effectively manage beams of even higher intensities.
△ Less
Submitted 4 August, 2023;
originally announced August 2023.
-
Recent Upgrades of the Gas Handling System for the Cryogenic Stop** Cell of the FRS Ion Catcher
Authors:
A. Mollaebrahimi,
D. Amanbayev,
S. Ayet San Andrés,
S. Beck,
J. Bergmann,
T. Dickel,
H. Geissel,
C. Hornung,
N. Kalantar-Nayestanaki,
G. Kripko-Koncz,
I. Miskun,
D. Nichita,
W. R. Plaß,
I. Pohjalainen,
C. Scheidenberger,
G. Stanic,
A. State,
J. Zhao
Abstract:
In this paper, the major upgrades and technical improvements of the buffer gas handling system for the cryogenic stop** cell of the FRS Ion Catcher at GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include implementation of new gas lines and gas purifiers to achieve a higher buffer gas cleanliness for a more efficient extraction of reactive ions as well as suppression of the molecu…
▽ More
In this paper, the major upgrades and technical improvements of the buffer gas handling system for the cryogenic stop** cell of the FRS Ion Catcher at GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include implementation of new gas lines and gas purifiers to achieve a higher buffer gas cleanliness for a more efficient extraction of reactive ions as well as suppression of the molecular background ionized in the stop** cell. Furthermore, additional techniques have been implemented for improved monitoring and quantification of the purity of the helium buffer gas.
△ Less
Submitted 25 July, 2023;
originally announced July 2023.
-
Mean range bunching of exotic nuclei produced by in-flight fragmentation and fission -- Stopped-beam experiments with increased efficiency
Authors:
Timo Dickel,
Christine Hornung,
Daler Amanbayev,
Samuel Ayet San Andres,
Soenke Beck,
Julian Bergmann,
Hans Geissel,
Juergen Gerl,
Magdalena Gorska,
Lizzy Groef,
Emma Haettner,
Jan-Paul Hucka,
Daria A. Kostyleva,
Gabriella Kripko-Koncz,
Ali Mollaebrahimi,
Ivan Mukha,
Stephane Pietri,
Wolfgang R. Plaß,
Zsolt Podolyak,
Sivaji Purushothaman,
Moritz Pascal Reiter,
Heidi Roesch,
Christoph Scheidenberger,
Yoshiki K. Tanaka,
Helmut Weick
, et al. (2 additional authors not shown)
Abstract:
The novel technique of mean range bunching has been developed and applied at the projectile fragment separator FRS at GSI in four experiments of the FAIR phase-0 experimental program. Using a variable degrader system at the final focal plane of the FRS, the ranges of the different nuclides can be aligned, allowing to efficiently implant a large number of different nuclides simultaneously in a gas-…
▽ More
The novel technique of mean range bunching has been developed and applied at the projectile fragment separator FRS at GSI in four experiments of the FAIR phase-0 experimental program. Using a variable degrader system at the final focal plane of the FRS, the ranges of the different nuclides can be aligned, allowing to efficiently implant a large number of different nuclides simultaneously in a gas-filled stop** cell or an implantation detector. Stop** and studying a cocktail beam overcomes the present limitations of stopped-beam experiments. The conceptual idea of mean range bunching is described and illustrated using simulations. In a single setting of the FRS, 37 different nuclides were stopped in the cryogenic stop** cell and were measured in a single setting broadband mass measurement with the multiple-reflection time-of-flight mass spectrometer of the FRS Ion Catcher.
△ Less
Submitted 30 May, 2023;
originally announced June 2023.
-
Storage, Accumulation and Deceleration of Secondary Beams for Nuclear Astrophysics
Authors:
J. Glorius,
Yu. A. Litvinov,
M. Aliotta,
F. Amjad,
B. Brückner,
C. G. Bruno,
R. Chen,
T. Davinson,
S. F. Dellmann,
T. Dickel,
I. Dillmann,
P. Erbacher,
O. Forstner,
H. Geissel,
C. J. Griffin,
R. Grisenti,
A. Gumberidze,
E. Haettner,
R. Hess,
P. -M. Hillenbrand,
C. Hornung,
R. Joseph,
B. Jurado,
E. Kazanseva,
R. Knöbel
, et al. (39 additional authors not shown)
Abstract:
Low-energy investigations on rare ion beams are often limited by the available intensity and purity of the ion species in focus. Here, we present the first application of a technique that combines in-flight production at relativistic energies with subsequent secondary beam storage, accumulation and finally deceleration to the energy of interest. Using the FRS and ESR facilities at GSI, this scheme…
▽ More
Low-energy investigations on rare ion beams are often limited by the available intensity and purity of the ion species in focus. Here, we present the first application of a technique that combines in-flight production at relativistic energies with subsequent secondary beam storage, accumulation and finally deceleration to the energy of interest. Using the FRS and ESR facilities at GSI, this scheme was pioneered to provide a secondary beam of $^{118}$Te$^{52+}$ for the measurement of nuclear proton-capture at energies of 6 and 7 MeV/u. The technique provided stored beam intensities of about $10^6$ ions at high purity and brilliance, representing a major step towards low-energy nuclear physics studies using rare ion beams.
△ Less
Submitted 30 May, 2023; v1 submitted 25 May, 2023;
originally announced May 2023.
-
Separation of atomic and molecular ions by ion mobility with an RF carpet
Authors:
Ivan Miskun,
Timo Dickel,
Samuel Ayet San Andres,
Julian Bergmann,
Paul Constantin,
Jens Ebert,
Hans Geissel,
Florian Greiner,
Emma Haettner,
Christine Hornung,
Wayne Lippert,
Israel Mardor,
Iain Moore,
Wolfgang R. Plaß,
Sivaji Purushothaman,
Ann-Kathrin Rink,
Moritz P. Reiter,
Christoph Scheidenberger,
Helmut Weick
Abstract:
Gas-filled stop** cells are used at accelerator laboratories for the thermalization of high-energy radioactive ion beams. Common challenges of many stop** cells are a high molecular background of extracted ions and limitations of extraction efficiency due to space-charge effects. At the FRS Ion Catcher at GSI, a new technique for removal of ionized molecules prior to their extraction out of th…
▽ More
Gas-filled stop** cells are used at accelerator laboratories for the thermalization of high-energy radioactive ion beams. Common challenges of many stop** cells are a high molecular background of extracted ions and limitations of extraction efficiency due to space-charge effects. At the FRS Ion Catcher at GSI, a new technique for removal of ionized molecules prior to their extraction out of the stop** cell has been developed. This technique utilizes the RF carpet for the separation of atomic ions from molecular contaminant ions through their difference in ion mobility. Results from the successful implementation and test during an experiment with a 600~MeV/u $^{124}$Xe primary beam are presented. Suppression of molecular contaminants by three orders of magnitude has been demonstrated. Essentially background-free measurement conditions with less than $1~\%$ of background events within a mass-to-charge range of 25 u/e have been achieved. The technique can also be used to reduce the space-charge effects at the extraction nozzle and in the downstream beamline, thus ensuring high efficiency of ion transport and highly-accurate measurements under space-charge-free conditions.
△ Less
Submitted 6 November, 2020; v1 submitted 27 July, 2020;
originally announced July 2020.
-
High-resolution, accurate MR-TOF-MS for short-lived, exotic nuclei of few events in their ground and low-lying isomeric states
Authors:
S. Ayet,
C. Hornung,
J. Ebert,
W. R. Plaß,
T. Dickel,
H. Geissel,
C. Scheidenberger,
J. Bergmann,
F. Greiner,
E. Haettner,
C. Jesch,
W. Lippert,
I. Mardor,
I. Miskun,
Z. Patyk,
S. Pietri,
A. Pihktelev,
S. Purushothaman,
M. P. Reiter,
A. -K. Rink,
H. Weick,
M. I. Yavor,
S. Bagchi,
V. Charviakova,
P. Constantin
, et al. (15 additional authors not shown)
Abstract:
Mass measurements of fission and projectile fragments, produced via $^{238}$U and $^{124}$Xe primary beams, have been performed with the multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) of the FRS Ion Catcher with a mass resolving powers (FWHM) up to 410,000 and an uncertainty of $6\cdot 10^{-8}$. The nuclides were produced and separated in-flight with the fragment separator FRS at…
▽ More
Mass measurements of fission and projectile fragments, produced via $^{238}$U and $^{124}$Xe primary beams, have been performed with the multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) of the FRS Ion Catcher with a mass resolving powers (FWHM) up to 410,000 and an uncertainty of $6\cdot 10^{-8}$. The nuclides were produced and separated in-flight with the fragment separator FRS at 300 to 1000 MeV/u and thermalized in a cryogenic stop** cell. The data-analysis procedure was developed to determine with highest accuracy the mass values and the corresponding uncertainties for the most challenging conditions: down to a few events in a spectrum and overlap** distributions, characterized only by a broader common peak shape. With this procedure, the resolution of low-lying isomers is increased by a factor of up to three compared to standard data analysis. The ground-state masses of 31 short-lived nuclides of 15 different elements with half-lives down to 17.9~ms and count rates as low as 11 events per nuclide were determined. This is the first direct mass measurement for seven nuclides. The excitation energies and the isomer-to-ground state ratios of six isomeric states with excitation energies down to about 280~keV were measured. For nuclides with known mass values, the average relative deviation from the literature values is $(2.9 \pm 6.2) \cdot 10^{-8}$. The measured two-neutron separation energies and their slopes near and at the N=126 and Z=82 shell closures indicate a strong element-dependent binding energy of the first neutron above the closed proton shell Z=82. The experimental results deviate strongly from the theoretical predictions, especially for N=126 and N=127.
△ Less
Submitted 31 January, 2019;
originally announced January 2019.