-
Digital Pixel Test Structures implemented in a 65 nm CMOS process
Authors:
Gianluca Aglieri Rinella,
Anton Andronic,
Matias Antonelli,
Mauro Aresti,
Roberto Baccomi,
Pascal Becht,
Stefania Beole,
Justus Braach,
Matthew Daniel Buckland,
Eric Buschmann,
Paolo Camerini,
Francesca Carnesecchi,
Leonardo Cecconi,
Edoardo Charbon,
Giacomo Contin,
Dominik Dannheim,
Joao de Melo,
Wen**g Deng,
Antonello di Mauro,
Jan Hasenbichler,
Hartmut Hillemanns,
Geun Hee Hong,
Artem Isakov,
Antoine Junique,
Alex Kluge
, et al. (27 additional authors not shown)
Abstract:
The ALICE ITS3 (Inner Tracking System 3) upgrade project and the CERN EP R&D on monolithic pixel sensors are investigating the feasibility of the Tower Partners Semiconductor Co. 65 nm process for use in the next generation of vertex detectors. The ITS3 aims to employ wafer-scale Monolithic Active Pixel Sensors thinned down to 20 to 40 um and bent to form truly cylindrical half barrels. Among the…
▽ More
The ALICE ITS3 (Inner Tracking System 3) upgrade project and the CERN EP R&D on monolithic pixel sensors are investigating the feasibility of the Tower Partners Semiconductor Co. 65 nm process for use in the next generation of vertex detectors. The ITS3 aims to employ wafer-scale Monolithic Active Pixel Sensors thinned down to 20 to 40 um and bent to form truly cylindrical half barrels. Among the first critical steps towards the realisation of this detector is to validate the sensor technology through extensive characterisation both in the laboratory and with in-beam measurements. The Digital Pixel Test Structure (DPTS) is one of the prototypes produced in the first sensor submission in this technology and has undergone a systematic measurement campaign whose details are presented in this article.
The results confirm the goals of detection efficiency and non-ionising and ionising radiation hardness up to the expected levels for ALICE ITS3 and also demonstrate operation at +20 C and a detection efficiency of 99% for a DPTS irradiated with a dose of $10^{15}$ 1 MeV n$_{\mathrm{eq}}/$cm$^2$. Furthermore, spatial, timing and energy resolutions were measured at various settings and irradiation levels.
△ Less
Submitted 10 July, 2023; v1 submitted 16 December, 2022;
originally announced December 2022.
-
First demonstration of in-beam performance of bent Monolithic Active Pixel Sensors
Authors:
ALICE ITS project,
:,
G. Aglieri Rinella,
M. Agnello,
B. Alessandro,
F. Agnese,
R. S. Akram,
J. Alme,
E. Anderssen,
D. Andreou,
F. Antinori,
N. Apadula,
P. Atkinson,
R. Baccomi,
A. Badalà,
A. Balbino,
C. Bartels,
R. Barthel,
F. Baruffaldi,
I. Belikov,
S. Beole,
P. Becht,
A. Bhatti,
M. Bhopal,
N. Bianchi
, et al. (230 additional authors not shown)
Abstract:
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to ra…
▽ More
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to radii of about 2cm without any signs of mechanical or electrical damage. During a subsequent characterisation using a 5.4GeV electron beam, it was further confirmed that they preserve their full electrical functionality as well as particle detection performance.
In this article, the bending procedure and the setup used for characterisation are detailed. Furthermore, the analysis of the beam test, including the measurement of the detection efficiency as a function of beam position and local inclination angle, is discussed. The results show that the sensors maintain their excellent performance after bending to radii of 2cm, with detection efficiencies above 99.9% at typical operating conditions, paving the way towards a new class of detectors with unprecedented low material budget and ideal geometrical properties.
△ Less
Submitted 17 August, 2021; v1 submitted 27 May, 2021;
originally announced May 2021.
-
Fluorescence Imaging In Vivo at Wavelengths beyond 1500 nm
Authors:
Shuo Diao,
Jeffrey L. Blackburn,
Guosong Hong,
Alexander L. Antaris,
Junlei Chang,
Justin Z. Wu,
Bo Zhang,
Kai Cheng,
Calvin J. Kuo,
Hongjie Dai
Abstract:
Compared to imaging in the visible and near-infrared regions below 900 nm, imaging in the second near-infrared window (NIR-II, 1000-1700 nm) is a promising method for deep-tissue high-resolution optical imaging in vivo mainly due to the reduced scattering of photons traversing through biological tissues. Herein, semiconducting single-walled carbon nanotubes with large diameters were used for in vi…
▽ More
Compared to imaging in the visible and near-infrared regions below 900 nm, imaging in the second near-infrared window (NIR-II, 1000-1700 nm) is a promising method for deep-tissue high-resolution optical imaging in vivo mainly due to the reduced scattering of photons traversing through biological tissues. Herein, semiconducting single-walled carbon nanotubes with large diameters were used for in vivo fluorescence imaging in the long-wavelength NIR region (1500-1700 nm, NIR-IIb). With this imaging agent, 3-4 um wide capillary blood vessels at a depth of about 3 mm could be resolved. Meanwhile, the blood-flow speeds in multiple individual vessels could be mapped simultaneously. Furthermore, NIR-IIb tumor imaging of a live mouse was explored. NIR-IIb imaging can be generalized to a wide range of fluorophores emitting at up to 1700 nm for high-performance in vivo optical imaging.
△ Less
Submitted 2 November, 2015; v1 submitted 9 February, 2015;
originally announced February 2015.
-
Through Skull Fluorescence Imaging of the Brain in a New Near-Infrared Window
Authors:
Guosong Hong,
Shuo Diao,
Junlei Chang,
Alexander L. Antaris,
Changxin Chen,
Bo Zhang,
Su Zhao,
Dmitriy N. Atochin,
Paul L. Huang,
Katrin I. Andreasson,
Calvin J. Kuo,
Hongjie Dai
Abstract:
To date, brain imaging has largely relied on X-ray computed tomography and magnetic resonance angiography with limited spatial resolution and long scanning times. Fluorescence-based brain imaging in the visible and traditional near-infrared regions (400-900 nm) is an alternative but currently requires craniotomy, cranial windows and skull thinning techniques, and the penetration depth is limited t…
▽ More
To date, brain imaging has largely relied on X-ray computed tomography and magnetic resonance angiography with limited spatial resolution and long scanning times. Fluorescence-based brain imaging in the visible and traditional near-infrared regions (400-900 nm) is an alternative but currently requires craniotomy, cranial windows and skull thinning techniques, and the penetration depth is limited to 1-2 mm due to light scattering. Here, we report through-scalp and through-skull fluorescence imaging of mouse cerebral vasculature without craniotomy utilizing the intrinsic photoluminescence of single-walled carbon nanotubes in the 1.3-1.4 micrometre near-infrared window. Reduced photon scattering in this spectral region allows fluorescence imaging reaching a depth of >2 mm in mouse brain with sub-10 micrometre resolution. An imaging rate of ~5.3 frames/s allows for dynamic recording of blood perfusion in the cerebral vessels with sufficient temporal resolution, providing real-time assessment of blood flow anomaly in a mouse middle cerebral artery occlusion stroke model.
△ Less
Submitted 7 August, 2014;
originally announced August 2014.
-
Ultra-Fast Fluorescence Imaging in Vivo with Conjugated Polymer Fluorophores in the Second Near-Infrared Window
Authors:
Guosong Hong,
Ying** Zou,
Alexander L. Antaris,
Shuo Diao,
Di Wu,
Kai Cheng,
Xiaodong Zhang,
Changxin Chen,
Bo Liu,
Yuehui He,
Justin Z. Wu,
Jun Yuan,
Bo Zhang,
Zhimin Tao,
Chihiro Fukunaga,
Hongjie Dai
Abstract:
In vivo fluorescence imaging in the second near-infrared window (1.0-1.7 microns) can afford deep tissue penetration and high spatial resolution, owing to the reduced scattering of long-wavelength photons. Here, we synthesize a series of low-bandgap donor/acceptor copolymers with tunable emission wavelengths of 1050-1350 nm in this window. Non-covalent functionalization with phospholipid-polyethyl…
▽ More
In vivo fluorescence imaging in the second near-infrared window (1.0-1.7 microns) can afford deep tissue penetration and high spatial resolution, owing to the reduced scattering of long-wavelength photons. Here, we synthesize a series of low-bandgap donor/acceptor copolymers with tunable emission wavelengths of 1050-1350 nm in this window. Non-covalent functionalization with phospholipid-polyethylene glycol results in water-soluble and biocompatible polymeric nanoparticles, allowing for live cell molecular imaging at > 1000 nm with polymer fluorophores for the first time. Importantly, the high quantum yield of the polymer allows for in vivo, deep-tissue and ultrafast imaging of mouse arterial blood flow with an unprecedented frame rate of > 25 frames per second. The high time resolution results in spatially and time resolved imaging of the blood flow pattern in cardiogram waveform over a single cardiac cycle (~ 200 ms) of a mouse, which has not been observed with fluorescence imaging in this window before.
△ Less
Submitted 25 June, 2014;
originally announced June 2014.
-
Multifunctional in vivo vascular imaging using near-infrared II fluorescence
Authors:
Guosong Hong,
Jerry C. Lee,
Joshua T. Robinson,
Uwe Raaz,
Liming Xie,
Ngan F. Huang,
John P. Cooke,
Hongjie Dai
Abstract:
In vivo real-time epifluorescence imaging of mouse hindlimb vasculatures in the second near-infrared region (NIR-II, 1.1~1.4 microns) is performed using single-walled carbon nanotubes (SWNTs) as fluorophores. Both high spatial resolution (~30 microns) and temporal resolution (<200 ms/frame) for small vessel imaging are achieved 1-3 mm deep in the tissue owing to the beneficial NIR-II optical windo…
▽ More
In vivo real-time epifluorescence imaging of mouse hindlimb vasculatures in the second near-infrared region (NIR-II, 1.1~1.4 microns) is performed using single-walled carbon nanotubes (SWNTs) as fluorophores. Both high spatial resolution (~30 microns) and temporal resolution (<200 ms/frame) for small vessel imaging are achieved 1-3 mm deep in the tissue owing to the beneficial NIR-II optical window that affords deep anatomical penetration and low scattering. This spatial resolution is unattainable by traditional NIR imaging (NIR-I, 0.75~0.9 microns) or microscopic computed tomography (micro-CT), while the temporal resolution far exceeds scanning microscopic imaging techniques. Arterial and venous vessels are unambiguously differentiated using a dynamic contrast-enhanced NIR-II imaging technique based on their distinct hemodynamics. Further, the deep tissue penetration, high spatial and temporal resolution of NIR-II imaging allow for precise quantifications of blood velocity in both normal and ischemic femoral arteries, which are beyond the capability of ultrasonography at lower blood velocity.
△ Less
Submitted 18 November, 2012;
originally announced November 2012.
-
Three-dimensional imaging of single nanotube molecule endocytosis on plasmonic substrates
Authors:
Guosong Hong,
Justin Z. Wu,
Joshua T. Robinson,
Hailiang Wang,
Bo Zhang,
Hongjie Dai
Abstract:
Investigating the cellular internalization pathways of single molecules or single nano-objects is important to understanding cell-matter interactions and to applications in drug delivery and discovery. Imaging and tracking the motion of single molecules on cell plasma membrane require high spatial resolution in three dimensions (3D). Fluorescence imaging along the axial dimension with nanometer re…
▽ More
Investigating the cellular internalization pathways of single molecules or single nano-objects is important to understanding cell-matter interactions and to applications in drug delivery and discovery. Imaging and tracking the motion of single molecules on cell plasma membrane require high spatial resolution in three dimensions (3D). Fluorescence imaging along the axial dimension with nanometer resolution has been highly challenging but critical to revealing displacements in trans-membrane events. Here, utilizing a plasmonic ruler based on the sensitive distance dependence of near-infrared fluorescence enhancement (NIR-FE) of carbon nanotubes on a gold plasmonic substrate, we probe ~10 nm scale trans-membrane displacements through changes in nanotube fluorescence intensity, enabling observations of single nanotube endocytosis in 3D. Cellular uptake and trans-membrane displacements show clear dependences to temperature and clathrin assembly on cell membrane, suggesting that the cellular entry mechanism for a nanotube molecule is via clathrin-dependent endocytosis through the formation of clathrin-coated pits on cell membrane.
△ Less
Submitted 29 January, 2012;
originally announced January 2012.
-
Near-Infrared Fluorescence Enhanced (NIR-FE) Molecular Imaging of Live Cells on Gold Substrates
Authors:
Guosong Hong,
Scott M. Tabakman,
Kevin Welsher,
Zhuo Chen,
Joshua T. Robinson,
Hailiang Wang,
Bo Zhang,
Hongjie Dai
Abstract:
Low quantum yields of near infrared (NIR) fluorophores have limited their capabilities as imaging probes in a transparent, low background imaging window. Here for the first time we reported near-infrared fluorescence enhance (NIR-FE) cell imaging using nanostructured Au substrate, which was employed as a general platform for both single-walled carbon nanotubes (SWNTs) and organic fluorescent label…
▽ More
Low quantum yields of near infrared (NIR) fluorophores have limited their capabilities as imaging probes in a transparent, low background imaging window. Here for the first time we reported near-infrared fluorescence enhance (NIR-FE) cell imaging using nanostructured Au substrate, which was employed as a general platform for both single-walled carbon nanotubes (SWNTs) and organic fluorescent labels in the NIR region. Fluorescence intensity, as well as cell targeting specificity, was greatly improved by this novel imaging technique. With NIR-FE imaging, we were able to image SWNT-stained cells at short exposure time of 300ms, and push the detectable limit of SWNT staining of cells down to an ultralow concentration of ~50 pM. Further, different degrees of fluorescence enhancement for endocytosed, intracellular SWNTs vs. nanotubes on the cell membrane at the cell/gold interface were observed, suggesting the possibility of using this technique to track the transmembrane behavior of NIR fluorophores.
△ Less
Submitted 15 March, 2011;
originally announced March 2011.