-
High-dimensional quantum key distribution using orbital angular momentum of single photons from a colloidal quantum dot at room temperature
Authors:
Dotan Halevi,
Boaz Lubotzky,
Kfir Sulimany,
Eric G. Bowes,
Jennifer A. Hollingsworth,
Yaron Bromberg,
Ronen Rapaport
Abstract:
High-dimensional quantum key distribution (HDQKD) is a promising avenue to address the inherent limitations of basic QKD protocols. However, experimental realizations of HDQKD to date have relied on indeterministic photon sources that limit the achievable key rate. In this paper, we demonstrate a full emulation of a HDQKD system using a single colloidal giant quantum dot (gQD) as a deterministic,…
▽ More
High-dimensional quantum key distribution (HDQKD) is a promising avenue to address the inherent limitations of basic QKD protocols. However, experimental realizations of HDQKD to date have relied on indeterministic photon sources that limit the achievable key rate. In this paper, we demonstrate a full emulation of a HDQKD system using a single colloidal giant quantum dot (gQD) as a deterministic, compact and room-temperature single-photon source (SPS). We demonstrate a practical protocol by encoding information in a high-dimensional space ($d = 3$) of the orbital angular momentum of the photons. Our experimental configuration incorporates two spatial light modulators for encoding and decoding the spatial information carried by individual photons. Our experimental demonstration establishes the feasibility of utilizing high radiative quantum yield gQDs as practical SPSs for HDQKD. We also demonstrate experimentally secure qudit transmission exceeding one secure bit per photon, thus already beating the traditional d=2 QKD capacity.
△ Less
Submitted 6 May, 2024;
originally announced May 2024.
-
Ultrafast and highly collimated radially polarized photons from a colloidal quantum dot in a hybrid nanoantenna at room-temperature
Authors:
Alexander Nazarov,
Yuval Bloom,
Boaz Lubotzky,
Hamza Abudayyeh,
Annika Mildner,
Lorenzo Baldessarini,
Yuval Shemla,
Eric G. Bowes,
Monika Fleischer,
Jennifer A. Hollingsworth,
Ronen Rapaport
Abstract:
To harness the potential of radially polarized single photons in applications such as high-dimensional quantum key distribution (HD-QKD) and quantum communication, we demonstrate an on-chip, room-temperature device, which generates highly directional radially polarized photons at very high rates. The photons are emitted from a giant CdSe/CdS colloidal quantum dot (gQD) accurately positioned at the…
▽ More
To harness the potential of radially polarized single photons in applications such as high-dimensional quantum key distribution (HD-QKD) and quantum communication, we demonstrate an on-chip, room-temperature device, which generates highly directional radially polarized photons at very high rates. The photons are emitted from a giant CdSe/CdS colloidal quantum dot (gQD) accurately positioned at the tip of a metal nanocone centered inside a hybrid metal-dielectric bullseye antenna. We show that due to the large and selective Purcell enhancement specifically for the out-of-plane optical dipole of the gQD, the emitted photons can have a very high degree of radial polarization (>93%), based on a quantitative metric. Our study emphasizes the importance of accurate gQD positioning for optimal radial polarization purity through extensive experiments and simulations, which contribute to the fundamental understanding of radial polarization in nanostructured devices and pave the way for implementation of such systems in practical applications using structured quantum light.
△ Less
Submitted 24 March, 2024; v1 submitted 11 March, 2024;
originally announced March 2024.
-
Room Temperature Fiber-Coupled single-photon devices based on Colloidal Quantum Dots and SiV centers in Back Excited Nanoantennas
Authors:
Boaz Lubotzky,
Alexander Nazarov,
Hamza Abudayyeh,
Lukas Antoniuk,
Niklas Lettner,
Viatcheslav Agafonov,
Anastasia V. Bennett,
Jennifer A. Hollingsworth,
Alexander Kubanek,
Ronen Rapaport
Abstract:
We demonstrate an important step towards on chip integration of single photon sources operating at room temperature fiber coupling of a directional quantum emitter with back-excitation. Directionality is achieved with a hybrid metal-dielectric bullseye antenna, while back-excitation is permitted by placement of the emitter at or in a sub-wavelength hole positioned at the bullseye center. Overall,…
▽ More
We demonstrate an important step towards on chip integration of single photon sources operating at room temperature fiber coupling of a directional quantum emitter with back-excitation. Directionality is achieved with a hybrid metal-dielectric bullseye antenna, while back-excitation is permitted by placement of the emitter at or in a sub-wavelength hole positioned at the bullseye center. Overall, the unique design enables a direct laser excitation from the back of the on-chip device and very efficient coupling of the highly collimated photon emission to either low numerical aperture (NA) free space optics or directly to an optical fiber from the front. To show the versatility of the concept, we fabricate devices containing either a colloidal quantum dot or a silicon-vacancy center containing nanodiamond, which are accurately coupled to the nano-antenna using two different nano-positioning methods. Both back-excited devices display front collection efficiencies of about 70 % at NAs as low as 0.5. Moreover, the combination of back-excitation with forward low-NA directionality enables direct coupling of the emitted photons into a proximal optical fiber without the need of any coupling optics, thereby facilitating and greatly simplifying future integration.
△ Less
Submitted 19 March, 2023;
originally announced March 2023.
-
Holographic immunoassays
Authors:
Kaitlynn Snyder,
Rushna Quddus,
Andrew D. Hollingsworth,
Kent Kirshenbaum,
David G. Grier
Abstract:
The size of a probe bead reported by holographic particle characterization depends on the proportion of the surface area covered by bound target molecules and so can be used as an assay for molecular binding. We validate this technique by measuring the kinetics of irreversible binding for the antibodies immunoglobulin G (IgG) and immunoglobulin M (IgM) as they attach to micrometer-diameter colloid…
▽ More
The size of a probe bead reported by holographic particle characterization depends on the proportion of the surface area covered by bound target molecules and so can be used as an assay for molecular binding. We validate this technique by measuring the kinetics of irreversible binding for the antibodies immunoglobulin G (IgG) and immunoglobulin M (IgM) as they attach to micrometer-diameter colloidal beads coated with protein A. These measurements yield the antibodies' binding rates and can be inverted to obtain the concentration of antibodies in solution. Holographic molecular binding assays therefore can be used to perform fast quantitative immunoassays that are complementary to conventional serological tests.
△ Less
Submitted 18 July, 2020;
originally announced July 2020.
-
Single Photon Sources with Near Unity Collection Efficiencies by Deterministic Placement of Quantum Dots in Nanoantennas
Authors:
Hamza Abudayyeh,
Boaz Lubotzky,
Anastasia Blake,
Jun Wang,
Somak Majumder,
Zhongjian Hu,
Younghee Kim,
Han Htoon,
Riya Bose,
Anton V. Malko,
Jennifer A. Hollingsworth,
Ronen Rapaport
Abstract:
Deterministic coupling between photonic nodes in a quantum network is an essential step towards implementing various quantum technologies. The omnidirectionality of free-standing emitters, however, makes this coupling highly inefficient, in particular if the distant nodes are coupled via low numerical aperture (NA) channels such as optical fibers. This limitation requires placing quantum emitters…
▽ More
Deterministic coupling between photonic nodes in a quantum network is an essential step towards implementing various quantum technologies. The omnidirectionality of free-standing emitters, however, makes this coupling highly inefficient, in particular if the distant nodes are coupled via low numerical aperture (NA) channels such as optical fibers. This limitation requires placing quantum emitters in nanoantennas that can direct the photons into the channels with very high efficiency. Moreover, to be able to scale such technologies to a large number of channels, the placing of the emitters should be deterministic. In this work we present a method for directly locating single free-standing quantum emitters with high spatial accuracy at the center of highly directional bullseye metal-dielectric nanoantennas. We further employ non-blinking, high quantum yield colloidal quantum dots (QDs) for on-demand single-photon emission that is uncompromised by instabilities or non-radiative exciton recombination processes. Taken together this approach results in a record-high collection efficiency of 85% of the single photons into a low NA of 0.5, setting the stage for efficient coupling between on-chip, room temperature nanoantenna-emitter devices and a fiber or a remote free-space node without the need for additional optics.
△ Less
Submitted 14 February, 2021; v1 submitted 23 May, 2020;
originally announced May 2020.
-
Purification of single photons by temporal heralding of quantum dot sources
Authors:
Hamza Abudayyeh,
Boaz Lubotzky,
Somak Majumder,
Jennifer A. Hollingsworth,
Ronen Rapaport
Abstract:
Efficient, high rate photon sources with high single photon purity are essential ingredients for quantum technologies. Single photon sources based on solid state emitters such as quantum dots are very advantageous for integrated photonic circuits, but they can suffer from a high two-photon emission probability, which in cases of non-cryogenic environment cannot be spectrally filtered. Here we prop…
▽ More
Efficient, high rate photon sources with high single photon purity are essential ingredients for quantum technologies. Single photon sources based on solid state emitters such as quantum dots are very advantageous for integrated photonic circuits, but they can suffer from a high two-photon emission probability, which in cases of non-cryogenic environment cannot be spectrally filtered. Here we propose two temporal purification-by-heralding methods for using a two photon emission process to yield highly pure and efficient single photon emission, bypassing the inherent problem of spectrally overlap** bi-photon emission. We experimentally demonstrate their feasibility on the emission from a single nanocrystal quantum dot, exhibiting single photon purities exceeding 99.5%, without a significant loss of single photon efficiency. These methods can be applied for any indeterministic source of spectrally broadband photon pairs.
△ Less
Submitted 10 December, 2018; v1 submitted 1 May, 2018;
originally announced May 2018.
-
Influence of Morphology on Blinking Mechanisms and Excitonic Fine Structure of Single Colloidal Nanoplatelets
Authors:
Zhongjian Hu,
Ajay Singh,
Serguei V. Goupalov,
Jennifer A. Hollingsworth,
Han Htoon
Abstract:
Colloidal semiconductor nanoplatelets (NPLs) with electronic structure as quantum wells have recently emerged as exciting materials for optoelectronic applications. Here we investigate how morphology affects important photoluminescence (PL) properties of single CdSe and core/shell CdSe/CdZnS nanoplatelets. By analyzing PL intensity-lifetime correlation and second-order photon correlation results,…
▽ More
Colloidal semiconductor nanoplatelets (NPLs) with electronic structure as quantum wells have recently emerged as exciting materials for optoelectronic applications. Here we investigate how morphology affects important photoluminescence (PL) properties of single CdSe and core/shell CdSe/CdZnS nanoplatelets. By analyzing PL intensity-lifetime correlation and second-order photon correlation results, we demonstrate that, irrespective of morphology, Auger recombination cannot be responsible for PL blinking of single NPLs. We propose that hot carrier trap** plays a significant role in blinking and find that a rough shell induces additional nonradiative channels presumably related to defects or traps of an imperfect shell. Polarization-resolved PL spectroscopy analysis reveals exciton fine-structure splitting on the order of several tens of meV in rough-shell NPLs at room temperature, which is attributed to exciton localization and substantiated with theoretical calculations taking into account the NPL shape and electron-hole exchange interaction.
△ Less
Submitted 21 March, 2018; v1 submitted 8 March, 2018;
originally announced March 2018.
-
Strong plasmonic enhancement of biexciton emission: controlled coupling of a single quantum dot to a gold nanocone antenna
Authors:
Korenobu Matsuzaki,
Simon Vassant,
Hsuan-Wei Liu,
Anke Dutschke,
Björn Hoffmann,
Xuewen Chen,
Silke Christiansen,
Matthew R. Buck,
Jennifer A. Hollingsworth,
Stephan Götzinger,
Vahid Sandoghdar
Abstract:
Multiexcitonic transitions and emission of several photons per excitation comprise a very attractive feature of semiconductor quantum dots for optoelectronics applications. However, these higher-order radiative processes are usually quenched in colloidal quantum dots by Auger and other non-radiative decay channels. To increase the multiexcitonic quantum efficiency, several groups have explored pla…
▽ More
Multiexcitonic transitions and emission of several photons per excitation comprise a very attractive feature of semiconductor quantum dots for optoelectronics applications. However, these higher-order radiative processes are usually quenched in colloidal quantum dots by Auger and other non-radiative decay channels. To increase the multiexcitonic quantum efficiency, several groups have explored plasmonic enhancement, so far with moderate results. By controlled positioning of individual quantum dots in the near field of gold nanocone antennas, we enhance the radiative decay rates of monoexcitons and biexcitons by 109 and 100 folds at quantum efficiencies of 60% and 70%, respectively, in very good agreement with the outcome of numerical calculations. We discuss the implications of our work for future fundamental and applied research in nano-optics.
△ Less
Submitted 28 August, 2016;
originally announced August 2016.
-
Experimental realization of an optical antenna for collecting 99% of photons from a quantum emitter
Authors:
X. -L. Chu,
T. J. K. Brenner,
X. -W. Chen,
Y. Ghosh,
J. A. Hollingsworth,
V. Sandoghdar,
S. Goetzinger
Abstract:
We present the fabrication and characterization of an optical antenna that converts the dipolar radiation of a quantum emitter to a directional beam with 99% efficiency. Aside from its implications for efficient detection of nanoscopic emitters, this antenna facilitates a deterministic single-photon source with applications in quantum information processing, metrology and sub-shot-noise detection…
▽ More
We present the fabrication and characterization of an optical antenna that converts the dipolar radiation of a quantum emitter to a directional beam with 99% efficiency. Aside from its implications for efficient detection of nanoscopic emitters, this antenna facilitates a deterministic single-photon source with applications in quantum information processing, metrology and sub-shot-noise detection of absorption. We discuss the photophysical limitations of the currently used quantum emitters for the realization of such a device.
△ Less
Submitted 3 June, 2014;
originally announced June 2014.
-
Measurement and simulation of the muon-induced neutron yield in lead
Authors:
L. Reichhart,
A. Lindote,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
V. Francis,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. A. Kudryavtsev,
V. N. Lebedenko,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. St J. Murphy
, et al. (14 additional authors not shown)
Abstract:
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well…
▽ More
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well the measured capture times and multiplicities and, within the dynamic range of the instrumentation, the spectrum of energy deposits. By comparing measurements with simulations of neutron capture rates a neutron yield in lead of (5.78^{+0.21}_{-0.28}) x 10^{-3} neutrons/muon/(g/cm^{2}) has been obtained. Absolute agreement between simulation and data is of order 25%. Consequences for deep underground rare event searches are discussed.
△ Less
Submitted 4 November, 2013; v1 submitted 18 February, 2013;
originally announced February 2013.
-
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Authors:
V. N. Solovov,
V. A. Belov,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. St J. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (11 additional authors not shown)
Abstract:
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the…
▽ More
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV gamma-rays. For the inner part of the detector (R<100 mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.
△ Less
Submitted 26 September, 2012; v1 submitted 7 December, 2011;
originally announced December 2011.
-
Performance data from the ZEPLIN-III second science run
Authors:
P. Majewski,
V. N. Solovov,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
A. St J. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (10 additional authors not shown)
Abstract:
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the…
▽ More
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the instrument performance with emphasis on the position and energy reconstruction algorithm and summarise the final science results.
△ Less
Submitted 30 November, 2011;
originally announced December 2011.
-
Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
Authors:
E. Santos,
B. Edwards,
V. Chepel,
H. M. Araujo,
D. Yu. Akimov,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
A. Currie,
L. DeViveiros,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (12 additional authors not shown)
Abstract:
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these…
▽ More
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these detectors. Then, using a realistic detector response model and backgrounds, we assess the feasibility of deploying such an instrument for measuring coherent neutrino-nucleus elastic scattering using the ionisation channel in the few-electron regime. We conclude that it should be possible to measure this elusive neutrino signature above an ionisation threshold of $\sim$3 electrons both at a stopped pion source and at a nuclear reactor. Detectable signal rates are larger in the reactor case, but the triggered measurement and harder recoil energy spectrum afforded by the accelerator source enable lower overall background and fiducialisation of the active volume.
△ Less
Submitted 13 October, 2011;
originally announced October 2011.
-
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Authors:
F. Neves,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. St J. Murphy,
S. M. Paling,
J. Pinto da Cunha,
R. Preece
, et al. (12 additional authors not shown)
Abstract:
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the d…
▽ More
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the detection of scintillation pulses down to a single photoelectron and of ionisation signals as small as those produced by single electrons. We discuss in particular several strategies related to data filtering, pulse finding and pulse clustering which are tuned to recover the best electron/nuclear recoil discrimination near the detection threshold, where most dark matter elastic scattering signatures are expected. The software was designed assuming only minimal knowledge of the physics underlying the detection principle, allowing an unbiased analysis of the experimental results and easy extension to other detectors with similar requirements.
△ Less
Submitted 4 June, 2011;
originally announced June 2011.
-
Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data
Authors:
M. Horn,
V. A. Belov,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
A. A. Burenkov,
V. Chepel,
A. Currie,
B. Edwards,
C. Ghag,
A. Hollingsworth,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (11 additional authors not shown)
Abstract:
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and r…
▽ More
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and resolution effects are treated using a light collection Monte Carlo, measured photomultiplier response profiles and hardware trigger studies. A gradual fall in scintillation yield below ~40 keVnr is found, together with a rising ionisation yield; both are in good agreement with the latest independent measurements. The analysis method is applied to both the most recent ZEPLIN-III data, acquired with a significantly upgraded detector and a precision-calibrated Am-Be source, as well as to the earlier data from the first run in 2008. A new method for deriving the recoil scintillation yield, which includes sub-threshold S1 events, is also presented which confirms the main analysis.
△ Less
Submitted 17 October, 2011; v1 submitted 3 June, 2011;
originally announced June 2011.
-
Radioactivity Backgrounds in ZEPLIN-III
Authors:
H. M. Araujo,
D. Yu. Akimov,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel. A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy. F. Neves,
S. M. Paling,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (10 additional authors not shown)
Abstract:
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level…
▽ More
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level Monte Carlo simulations propagating the effects of the radiological contamination measured for materials employed in the experiment. Neutron elastic scattering is predicted to yield 3.05$\pm$0.5 nuclear recoils with energy 5-50 keV per year, which translates to an expectation of 0.4 events in a 1-year dataset in anti-coincidence with the veto detector for realistic signal acceptance. Less obvious background sources are discussed, especially in the context of future experiments. These include contamination of scintillation pulses with Cherenkov light from Compton electrons and from $β$ activity internal to photomultipliers, which can increase the size and lower the apparent time constant of the scintillation response. Another challenge is posed by multiple-scatter $γ$-rays with one or more vertices in regions that yield no ionisation. If the discrimination power achieved in the first run can be replicated, ZEPLIN-III should reach a sensitivity of $\sim 1 \times 10^{-8}$ pb$\cdot$year to the scalar WIMP-nucleon elastic cross-section, as originally conceived.
△ Less
Submitted 12 August, 2011; v1 submitted 18 April, 2011;
originally announced April 2011.