Measurement and tricubic interpolation of the magnetic field for the OLYMPUS experiment
Authors:
J. C. Bernauer,
J. Diefenbach,
G. Elbakian,
G. Gavrilov,
N. Goerrissen,
D. K. Hasel,
B. S. Henderson,
Y. Holler,
G. Karyan,
J. Ludwig,
H. Marukyan,
Y. Naryshkin,
C. O'Connor,
R. L. Russell,
A. Schmidt,
U. Schneekloth,
K. Suvorov,
D. Veretennikov
Abstract:
The OLYMPUS experiment used a 0.3 T toroidal magnetic spectrometer to measure the momenta of outgoing charged particles. In order to accurately determine particle trajectories, knowledge of the magnetic field was needed throughout the spectrometer volume. For that purpose, the magnetic field was measured at over 36,000 positions using a three-dimensional Hall probe actuated by a system of translat…
▽ More
The OLYMPUS experiment used a 0.3 T toroidal magnetic spectrometer to measure the momenta of outgoing charged particles. In order to accurately determine particle trajectories, knowledge of the magnetic field was needed throughout the spectrometer volume. For that purpose, the magnetic field was measured at over 36,000 positions using a three-dimensional Hall probe actuated by a system of translation tables. We used these field data to fit a numerical magnetic field model, which could be employed to calculate the magnetic field at any point in the spectrometer volume. Calculations with this model were computationally intensive; for analysis applications where speed was crucial, we pre-computed the magnetic field and its derivatives on an evenly spaced grid so that the field could be interpolated between grid points. We developed a spline-based interpolation scheme suitable for SIMD implementations, with a memory layout chosen to minimize space and optimize the cache behavior to quickly calculate field values. This scheme requires only one-eighth of the memory needed to store necessary coefficients compared with a previous scheme [1]. This method was accurate for the vast majority of the spectrometer volume, though special fits and representations were needed to improve the accuracy close to the magnet coils and along the toroid axis.
△ Less
Submitted 21 March, 2016;
originally announced March 2016.
-
The OLYMPUS Experiment
Authors:
R. Milner,
D. K. Hasell,
M. Kohl,
U. Schneekloth,
N. Akopov,
R. Alarcon,
V. A. Andreev,
O. Ates,
A. Avetisyan,
D. Bayadilov,
R. Beck,
S. Belostotski,
J. C. Bernauer,
J. Bessuille,
F. Brinker,
B. Buck,
J. R. Calarco,
V. Carassiti,
E. Cisbani,
G. Ciullo,
M. Contalbrigo,
N. D'Ascenzo,
R. De Leo,
J. Diefenbach,
T. W. Donnelly
, et al. (48 additional authors not shown)
Abstract:
The OLYMPUS experiment was designed to measure the ratio between the positron-proton and electron-proton elastic scattering cross sections, with the goal of determining the contribution of two-photon exchange to the elastic cross section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, $μ_p G^p_E/G^p_M$, made using polarization techniques and…
▽ More
The OLYMPUS experiment was designed to measure the ratio between the positron-proton and electron-proton elastic scattering cross sections, with the goal of determining the contribution of two-photon exchange to the elastic cross section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, $μ_p G^p_E/G^p_M$, made using polarization techniques and those made in unpolarized experiments. OLYMPUS operated on the DORIS storage ring at DESY, alternating between 2.01~GeV electron and positron beams incident on an internal hydrogen gas target. The experiment used a toroidal magnetic spectrometer instrumented with drift chambers and time-of-flight detectors to measure rates for elastic scattering over the polar angular range of approximately $25^\circ$--$75^\circ$. Symmetric Møller/Bhabha calorimeters at $1.29^\circ$ and telescopes of GEM and MWPC detectors at $12^\circ$ served as luminosity monitors. A total luminosity of approximately 4.5~fb$^{-1}$ was collected over two running periods in 2012. This paper provides details on the accelerator, target, detectors, and operation of the experiment.
△ Less
Submitted 5 December, 2013;
originally announced December 2013.
-
The HERMES Recoil Detector
Authors:
A. Airapetian,
E. C. Aschenauer,
S. Belostotski,
A. Borissov,
A. Borisenko,
J. Bowles,
I. Brodski,
V. Bryzgalov,
J. Burns,
G. P. Capitani,
V. Carassiti,
G. Ciullo,
A. Clarkson,
M. Contalbrigo,
R. De Leo,
E. De Sanctis,
M. Diefenthaler,
P. Di Nezza,
M. Düren,
M. Ehrenfried,
H. Guler,
I. M. Gregor,
M. Hartig,
G. Hill,
M. Hoek
, et al. (58 additional authors not shown)
Abstract:
For the final running period of HERA, a recoil detector was installed at the HERMES experiment to improve measurements of hard exclusive processes in charged-lepton nucleon scattering. Here, deeply virtual Compton scattering is of particular interest as this process provides constraints on generalised parton distributions that give access to the total angular momenta of quarks within the nucleon.…
▽ More
For the final running period of HERA, a recoil detector was installed at the HERMES experiment to improve measurements of hard exclusive processes in charged-lepton nucleon scattering. Here, deeply virtual Compton scattering is of particular interest as this process provides constraints on generalised parton distributions that give access to the total angular momenta of quarks within the nucleon. The HERMES recoil detector was designed to improve the selection of exclusive events by a direct measurement of the four-momentum of the recoiling particle. It consisted of three components: two layers of double-sided silicon strip sensors inside the HERA beam vacuum, a two-barrel scintillating fibre tracker, and a photon detector. All sub-detectors were located inside a solenoidal magnetic field with an integrated field strength of 1 T. The recoil detector was installed in late 2005. After the commissioning of all components was finished in September 2006, it operated stably until the end of data taking at HERA end of June 2007. The present paper gives a brief overview of the physics processes of interest and the general detector design. The recoil detector components, their calibration, the momentum reconstruction of charged particles, and the event selection are described in detail. The paper closes with a summary of the performance of the detection system.
△ Less
Submitted 6 May, 2013; v1 submitted 25 February, 2013;
originally announced February 2013.