Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider
Authors:
A. Lyapin,
H. J. Schreiber,
M. Viti,
C. Adolphsen,
R. Arnold,
S. Boogert,
G. Boorman,
M. V. Chistiakova,
F. Gournaris,
V. Duginov,
C. Hast,
M. D. Hildreth,
C. Hlaing,
F. Jackson,
O. Khainovsky,
Yu. G. Kolomensky,
S. Kostromin,
K. Kumar,
B. Maiheu,
D. McCormick,
D. J. Miller,
N. Morozov,
T. Orimoto,
E. Petigura,
M. Sadre-Bazzaz
, et al. (7 additional authors not shown)
Abstract:
The International Linear Collider and other proposed high energy e+ e- machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 1e-4. This article presents the analysis of data from a prototype energy spectromete…
▽ More
The International Linear Collider and other proposed high energy e+ e- machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 1e-4. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006--2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5e-4 was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.
△ Less
Submitted 27 January, 2011; v1 submitted 1 November, 2010;
originally announced November 2010.
Cavity BPM System Tests for the ILC Spectrometer
Authors:
M. Slater,
C. Adolphsen,
R. Arnold,
S. Boogert,
G. Boorman,
F. Gournaris,
M. Hildreth,
C. Hlaing,
F. Jackson,
O. Khainovski,
Yu. G. Kolomensky,
A. Lyapin,
B. Maiheu,
D. McCormick,
D. J. Miller,
T. J. Orimoto,
Z. Szalata,
M. Thomson,
D. Ward,
M. Wing,
M. Woods
Abstract:
The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of $10^{-4}$ or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-…
▽ More
The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of $10^{-4}$ or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 hours for a $1\m$ long BPM triplet. We find micron-level stability over 1 hour for 3 BPM stations distributed over a $30\m$ long baseline. The understanding of the behaviour and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.
△ Less
Submitted 9 December, 2007;
originally announced December 2007.