Experimental observation of $β$-delayed neutrons from $^{9}$Li as a way to study short-pulse laser-driven deuteron production
Authors:
Andrea Favalli,
Nevzat Guler,
Daniela Henzlova,
Katerina Falk,
Stephen Croft,
Donald C. Gautier,
Kiril D. Ianakiev,
Metodi Iliev,
Sasikumar Palaniyappan,
Markus Roth,
Juan C. Fernandez,
Martyn T. Swinhoe
Abstract:
A short-pulse laser-driven deuteron beam is generated in the relativistic transparency regime and aimed at a beryllium converter to generate neutrons at the TRIDENT laser facility. These prompt neutrons have been used for active interrogation to detect nuclear materials, the first such demonstration of a laser-driven neutron source. During the experiments, delayed neutrons from $^9$Li decay was ob…
▽ More
A short-pulse laser-driven deuteron beam is generated in the relativistic transparency regime and aimed at a beryllium converter to generate neutrons at the TRIDENT laser facility. These prompt neutrons have been used for active interrogation to detect nuclear materials, the first such demonstration of a laser-driven neutron source. During the experiments, delayed neutrons from $^9$Li decay was observed. It was identified by its characteristic half-life of 178.3 ms. Production is attributed to the nuclear reactions $^9$Be(d,2p)$^9$Li and $^9$Be(n,p)$^9$Li inside the beryllium converter itself. These reactions have energy thresholds of 18.42 and 14.26 MeV respectively, and we estimate the (d,2p) reaction to be the dominant source of $^9$Li production. Therefore, only the higher-energy portion of the deuteron spectrum contributes to the production of the delayed neutrons. It was observed that the delayed-neutron yield decreases with increasing distance between the converter and the deuteron source. This behavior is consistent with deuteron production with energy greater than $\sim$20 MeV within a cone with a half-angle greater than 40$^{\circ}$. Prompt-neutron time-of-flight measurements at varying separation between the converter and the laser target indicate that the fast deuteron population above threshold is severely depleted on axis out to $\sim$20$^{\circ}$. These measurements are consistent with emission of the fast deuterons (i.e., above 10 MeV/nucleon) in a ring-like fashion around the central axis. Such an inferred ring-like structure is qualitatively consistent with a documented signature of the breakout afterburner (BOA) laser-plasma ion acceleration mechanism. The measurement of $β$-delayed neutrons from $^9$Li decay could provide an important new diagnostic tool for the study of the features of the deuteron production mechanism in a non-intrusive way.
△ Less
Submitted 18 May, 2016;
originally announced May 2016.
Tracking rare-isotope beams with microchannel plates
Authors:
A. M. Rogers,
A. Sanetullaev,
W. G. Lynch,
M. B. Tsang,
J. Lee,
D. Bazin,
D. Coupland,
V. Henzl,
D. Henzlova,
M. Kilburn,
M. S. Wallace,
M. Youngs,
F. Delaunay,
M. Famiano,
D. Shapira,
K. L. Jones,
K. T. Schmitt,
Z. Y. Sun
Abstract:
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams,…
▽ More
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams, the magnetic field strength between the secondary-electron accelerating foil and the microchannel plate had to be increased substantially. Results from an experiment using a 37-MeV/nucleon ${}^{56}$Ni beam show that the tracking system can achieve sub-nanosecond timing resolution and a position resolution of $\sim$1 mm for beam intensities up to $5\times10^{5}$ pps.
△ Less
Submitted 11 September, 2013;
originally announced September 2013.