-
Wide-range resistivity characterization of semiconductors with terahertz time-domain spectroscopy
Authors:
Joshua Hennig,
Jens Klier,
Stefan Duran,
Kuei-Shen Hsu,
Jan Beyer,
Christian Röder,
Franziska C. Beyer,
Nadine Schüler,
Nico Vieweg,
Katja Dutzi,
Georg von Freymann,
Daniel Molter
Abstract:
Resistivity is one of the most important characteristics in the semiconductor industry. The most common way to measure resistivity is the four-point probe method, which requires physical contact with the material under test. Terahertz time domain spectroscopy, a fast and non-destructive measurement method, is already well established in the characterization of dielectrics. In this work, we demonst…
▽ More
Resistivity is one of the most important characteristics in the semiconductor industry. The most common way to measure resistivity is the four-point probe method, which requires physical contact with the material under test. Terahertz time domain spectroscopy, a fast and non-destructive measurement method, is already well established in the characterization of dielectrics. In this work, we demonstrate the potential of two Drude model-based approaches to extract resistivity values from terahertz time-domain spectroscopy measurements of silicon in a wide range from about 10$^{-3}$ $Ω$cm to 10$^{2}$ $Ω$cm. One method is an analytical approach and the other is an optimization approach. Four-point probe measurements are used as a reference. In addition, the spatial resistivity distribution is imaged by X-Y scanning of the samples to detect inhomogeneities in the do** distribution.
△ Less
Submitted 23 January, 2024;
originally announced January 2024.
-
Robust Centerline Prediction for Accurate Vessel Wall Visualization of Intracranial Vessels in Multi-Contrast 3D MRI Data
Authors:
Patrick Vogel,
Thomas Kampf,
Konstanze Guggenberger,
Esther Raithel,
Christoph Forman,
Stephan Meckel,
Ute Ludwig,
Axel J. Krafft,
Jürgen Hennig,
Thorsten A. Bley
Abstract:
An accurate planar visualization (curved planar reformation - CPR) of intracranial arteries is mandatory for an improved luminal and mural assessment especially in low resolution Magnetic Resonance Imaging (MRI) data sets acquired in standard clinical settings. CPR visualization methods based on the centerline of the desired structure are fast and easy to implement but the accuracy strongly depend…
▽ More
An accurate planar visualization (curved planar reformation - CPR) of intracranial arteries is mandatory for an improved luminal and mural assessment especially in low resolution Magnetic Resonance Imaging (MRI) data sets acquired in standard clinical settings. CPR visualization methods based on the centerline of the desired structure are fast and easy to implement but the accuracy strongly depends on the spatial resolution of the 3D data set and the size of the desired vessel. In the manuscript, a novel algorithm for fast and robust centerline calculation in multi-contrast 3D MRI data is presented. It considers the extracted surface of the vessel structure for a more accurate centerline prediction resulting in an enhanced CPR visualization of small vessels.
△ Less
Submitted 3 September, 2022;
originally announced September 2022.
-
Phase-quadrature quantum imaging with undetected photons
Authors:
Björn Erik Haase,
Joshua Hennig,
Mirco Kutas,
Erik Waller,
Julian Hering,
Georg von Freymann,
Daniel Molter
Abstract:
Sensing with undetected photons allows access to spectral regions with simultaneous detection of photons of another region and is based on nonlinear interferometry. To obtain the full information of a sample, the corresponding interferogram has to be analyzed in terms of amplitude and phase, which has been realized so far by multiple measurements followed by phase variation. Here, we present a pol…
▽ More
Sensing with undetected photons allows access to spectral regions with simultaneous detection of photons of another region and is based on nonlinear interferometry. To obtain the full information of a sample, the corresponding interferogram has to be analyzed in terms of amplitude and phase, which has been realized so far by multiple measurements followed by phase variation. Here, we present a polarization-optics-based phase-quadrature implementation in a nonlinear interferometer for imaging with undetected photons in the infrared region. This allows us to obtain phase and visibility with a single image acquisition without the need of varying optical paths or phases, thus enabling the detection of dynamic processes. We demonstrate the usefullness of our method on a static phase mask opaque to the detected photons as well as on dynamic measurement tasks as the drying of an isopropanol film and the stretching of an adhesive tape.
△ Less
Submitted 5 August, 2022;
originally announced August 2022.
-
ETpathfinder: a cryogenic testbed for interferometric gravitational-wave detectors
Authors:
A. Utina,
A. Amato,
J. Arends,
C. Arina,
M. de Baar,
M. Baars,
P. Baer,
N. van Bakel,
W. Beaumont,
A. Bertolini,
M. van Beuzekom,
S. Biersteker,
A. Binetti,
H. J. M. ter Brake,
G. Bruno,
J. Bryant,
H. J. Bulten,
L. Busch,
P. Cebeci,
C. Collette,
S. Cooper,
R. Cornelissen,
P. Cuijpers,
M. van Dael,
S. Danilishin
, et al. (90 additional authors not shown)
Abstract:
The third-generation of gravitational wave observatories, such as the Einstein Telescope (ET) and Cosmic Explorer (CE), aim for an improvement in sensitivity of at least a factor of ten over a wide frequency range compared to the current advanced detectors. In order to inform the design of the third-generation detectors and to develop and qualify their subsystems, dedicated test facilities are req…
▽ More
The third-generation of gravitational wave observatories, such as the Einstein Telescope (ET) and Cosmic Explorer (CE), aim for an improvement in sensitivity of at least a factor of ten over a wide frequency range compared to the current advanced detectors. In order to inform the design of the third-generation detectors and to develop and qualify their subsystems, dedicated test facilities are required. ETpathfinder prototype uses full interferometer configurations and aims to provide a high sensitivity facility in a similar environment as ET. Along with the interferometry at 1550 nm and silicon test masses, ETpathfinder will focus on cryogenic technologies, lasers and optics at 2090 nm and advanced quantum-noise reduction schemes. This paper analyses the underpinning noise contributions and combines them into full noise budgets of the two initially targeted configurations: 1) operating with 1550 nm laser light and at a temperature of 18 K and 2) operating at 2090 nm wavelength and a temperature of 123 K.
△ Less
Submitted 10 June, 2022;
originally announced June 2022.
-
Single Shot Spiral TSE with Annulated Segmentation
Authors:
Juergen Hennig,
Antonia Barhoorn,
Shuoyue Zhang,
Maxim Zaitsev
Abstract:
Purpose: To develop, optimize and implement a single shot spiral TSE-sequence at 3 T and to demonstrate its feasibility to acquire artefact free images of the central nervous system with 1 mm spatial resolution in < 200 ms. Theory and Methods: Spiral TSE sequences with annulated spiral segmentation have been implemented with different acquisition modes. In fixed mode the duration of each spiral se…
▽ More
Purpose: To develop, optimize and implement a single shot spiral TSE-sequence at 3 T and to demonstrate its feasibility to acquire artefact free images of the central nervous system with 1 mm spatial resolution in < 200 ms. Theory and Methods: Spiral TSE sequences with annulated spiral segmentation have been implemented with different acquisition modes. In fixed mode the duration of each spiral segment is fixed to fill the available acquisition time tacq. In tangential mode, the beginning of each spiral segment is reached via a straight tangential trajectory. Tangential mode allows faster transition and thus longer tacq for a given echo spacing ESP, but less data points can be acquired per acquisition interval. Alternating between spiral-in and spiral-out readout in alternating echoes leads to a somewhat different point spread function for off-resonant spins. Results: Images of the brain with 1 mm spatial resolution acquired with a variable density spiral with ~45 % undersampling can be acquired in a single shot. All acquisition modes produce comparable image quality. Only mild artifacts in regions of strong susceptibility effects can be observed for ESP of 10 ms and below. The use of variable flip angle schemes allows seamless acquisition of consecutive slices and/or dynamic scans without waiting time between consecutive acquisitions. Comparison with images acquired at 1.5 T shows reduced susceptibility artifacts within the brain and facial structures.. Conclusion: Single shot spiral TSE has been demonstrated to enable highly efficient acquisition of high-resolution images of the brain in < 200 ms per slice.
△ Less
Submitted 29 November, 2021;
originally announced November 2021.
-
Selectively pulsed spin order transfer increases parahydrogen-induced NMR amplification of insensitive nuclei and makes polarization transfer more robust
Authors:
Andreas B. Schmidt,
Arne Brahms,
Frowin Ellermann,
Stephan Berner,
Jürgen Hennig,
Dominik von Elverfeldt,
Rainer Herges,
Jan-Bernd Hövener,
Andrey N. Pravdivtsev
Abstract:
We describe a new method for pulsed spin order transfer (SOT) of parahydrogen induced polarization (PHIP) that enables close to 100 % polarization in incompletely 2H-labeled molecules by exciting only the desired protons in a frequency-selective manner. While a selective pulse (SP) on 1H at the beginning of pulsed SOT had been considered before, using SPs during the SOT suppresses undesired indire…
▽ More
We describe a new method for pulsed spin order transfer (SOT) of parahydrogen induced polarization (PHIP) that enables close to 100 % polarization in incompletely 2H-labeled molecules by exciting only the desired protons in a frequency-selective manner. While a selective pulse (SP) on 1H at the beginning of pulsed SOT had been considered before, using SPs during the SOT suppresses undesired indirect spin-spin interactions. As a result, we achieved a more robust SOT for the SP variants of the phINEPT+ sequence that we refer to as phSPINEPT+. Thereby, for the first time, we report a sequence that is effective for all weakly coupled spin systems. Our simulations show that the method converts close to 100 % of the parahydrogen-derived spin order into 13C hyperpolarization in weakly coupled three-spin systems and partially or fully 2H-labeled molecules if relaxation is neglected. Experimentally we demonstrate high hyperpolarization of 13C with 15.8 % for 1-13C-hydroxyethyl propionate-d3 and 12.6 % for 1-13C-ethyl acetate-d6, which corresponds to ~47 % and ~38 % if the enrichment of parahydrogen had been 100 %. Even in non-2H-labeled molecules, a remarkable 13C polarization is achieved, e.g. up to 20 % were simulated for 100 % pH2, and 1.25 % were obtained experimentally for 1-13C-ethyl pyruvate and 50 % pH2, which can be further improved by faster hydrogenation. As a result, full deuterium labeling may no longer be required e.g., when new PHIP agents are investigated, the synthesis of fully deuterated molecules is too complex, or when a kinetic isotope effect regarding the metabolic conversion rate of an agent is to be avoided. Using SPs during SOT seems very promising and may be extended to other sequences in the context of PHIP and be-yond to make them less prone to experimental imperfections or real molecular environments.
△ Less
Submitted 10 September, 2021;
originally announced September 2021.
-
Parametric Sequential Method for MRI-based Wall Shear Stress Quantification
Authors:
Nina Shokina,
Gabriel Teschner,
Andreas Bauer,
Cameron Tropea,
Herbert Egger,
Jürgen Hennig,
Axel J. Krafft
Abstract:
Wall shear stress (WSS) has been suggested as a potential biomarker in various cardiovascular diseases and it can be estimated from phase-contrast Magnetic Resonance Imaging (PC-MRI) velocity measurements. We present a new parametric sequential method for MRI-based WSS quantification consisting of a geometry identification and a subsequent approximation of the velocity field. The new method was va…
▽ More
Wall shear stress (WSS) has been suggested as a potential biomarker in various cardiovascular diseases and it can be estimated from phase-contrast Magnetic Resonance Imaging (PC-MRI) velocity measurements. We present a new parametric sequential method for MRI-based WSS quantification consisting of a geometry identification and a subsequent approximation of the velocity field. The new method was validated on well controlled, high resolution in vitro measurements of turbulent stationary flows and physiological pulsatile flows in phantoms. Basic applicability to in vivo was demonstrated using 2D PC-MRI data of the ascending aorta of three volunteers.
△ Less
Submitted 21 October, 2020; v1 submitted 15 June, 2020;
originally announced June 2020.
-
A Cryogenic Silicon Interferometer for Gravitational-wave Detection
Authors:
Rana X Adhikari,
Odylio Aguiar,
Koji Arai,
Bryan Barr,
Riccardo Bassiri,
Garilynn Billingsley,
Ross Birney,
David Blair,
Joseph Briggs,
Aidan F Brooks,
Daniel D Brown,
Huy-Tuong Cao,
Marcio Constancio,
Sam Cooper,
Thomas Corbitt,
Dennis Coyne,
Edward Daw,
Johannes Eichholz,
Martin Fejer,
Andreas Freise,
Valery Frolov,
Slawomir Gras,
Anna Green,
Hartmut Grote,
Eric K Gustafson
, et al. (86 additional authors not shown)
Abstract:
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new inst…
▽ More
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor.
△ Less
Submitted 9 June, 2020; v1 submitted 29 January, 2020;
originally announced January 2020.
-
Demonstration of a switchable dam** system to allow low-noise operation of high-Q low-mass suspension systems
Authors:
Jan-Simon Hennig,
Bryan W. Barr,
Angus S. Bell,
William Cunningham,
Stefan L. Danilishin,
Peter Dupej,
Christian Graef,
Sabina H. Huttner,
Russell Jones,
Sean S. Leavey,
Daniela Pascucci,
Martin Sinclair,
Borja Sorazu,
Andrew Spencer,
Sebastian Steinlechner,
Kenneth A. Strain,
Jennifer Wright,
Teng Zhang,
Stefan Hild
Abstract:
Low mass suspension systems with high-Q pendulum stages are used to enable quantum radiation pressure noise limited experiments. Utilising multiple pendulum stages with vertical blade springs and materials with high quality factors provides attenuation of seismic and thermal noise, however dam** of these high-Q pendulum systems in multiple degrees of freedom is essential for practical implementa…
▽ More
Low mass suspension systems with high-Q pendulum stages are used to enable quantum radiation pressure noise limited experiments. Utilising multiple pendulum stages with vertical blade springs and materials with high quality factors provides attenuation of seismic and thermal noise, however dam** of these high-Q pendulum systems in multiple degrees of freedom is essential for practical implementation. Viscous dam** such as eddy-current dam** can be employed but introduces displacement noise from force noise due to thermal fluctuations in the dam** system. In this paper we demonstrate a passive dam** system with adjustable dam** strength as a solution for this problem that can be used for low mass suspension systems without adding additional displacement noise in science mode. We show a reduction of the dam** factor by a factor of 8 on a test suspension and provide a general optimisation for this system.
△ Less
Submitted 25 October, 2017; v1 submitted 24 October, 2017;
originally announced October 2017.
-
Towards the LISA Backlink: Experiment design for comparing optical phase reference distribution systems
Authors:
Katharina-Sophie Isleif,
Lea Bischof,
Stefan Ast,
Daniel Penkert,
Thomas S Schwarze,
Germán Fernández Barranco,
Max Zwetz,
Sonja Veith,
Jan-Simon Hennig,
Michael Tröbs,
Jens Reiche,
Oliver Gerberding,
Karsten Danzmann,
Gerhard Heinzel
Abstract:
LISA is a proposed space-based laser interferometer detecting gravitational waves by measuring distances between free-floating test masses housed in three satellites in a triangular constellation with laser links in-between. Each satellite contains two optical benches that are articulated by moving optical subassemblies for compensating the breathing angle in the constellation. The phase reference…
▽ More
LISA is a proposed space-based laser interferometer detecting gravitational waves by measuring distances between free-floating test masses housed in three satellites in a triangular constellation with laser links in-between. Each satellite contains two optical benches that are articulated by moving optical subassemblies for compensating the breathing angle in the constellation. The phase reference distribution system, also known as backlink, forms an optical bi-directional path between the intra-satellite benches.
In this work we discuss phase reference implementations with a target non-reciprocity of at most $2π\,\mathrm{μrad/\sqrt{Hz}}$, equivalent to $1\,\mathrm{pm/\sqrt{Hz}}$ for a wavelength of $1064\,\mathrm{nm}$ in the frequency band from $0.1\,\mathrm{mHz}$ to $1\,\mathrm{Hz}$. One phase reference uses a steered free beam connection, the other one a fiber together with additional laser frequencies. The noise characteristics of these implementations will be compared in a single interferometric set-up with a previously successfully tested direct fiber connection. We show the design of this interferometer created by optical simulations including ghost beam analysis, component alignment and noise estimation. First experimental results of a free beam laser link between two optical set-ups that are co-rotating by $\pm 1^\circ$ are presented. This experiment demonstrates sufficient thermal stability during rotation of less than $10^{-4}\,\mathrm{K/\sqrt{Hz}}$ at $1\,\mathrm{mHz}$ and operation of the free beam steering mirror control over more than 1 week.
△ Less
Submitted 12 January, 2018; v1 submitted 19 September, 2017;
originally announced September 2017.
-
Low Rank Alternating Direction Method of Multipliers Reconstruction for MR Fingerprinting
Authors:
Jakob Assländer,
Martijn A Cloos,
Florian Knoll,
Daniel K Sodickson,
Jürgen Hennig,
Riccardo Lattanzi
Abstract:
Purpose
The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for Magnetic Resonance Fingerprinting (MRF).
Methods
Based on a singular value decomposition (SVD) of the signal evolution, MRF is formulated as a low rank inverse problem in which one image is reconstructed for each singular value under consideration. This low rank app…
▽ More
Purpose
The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for Magnetic Resonance Fingerprinting (MRF).
Methods
Based on a singular value decomposition (SVD) of the signal evolution, MRF is formulated as a low rank inverse problem in which one image is reconstructed for each singular value under consideration. This low rank approximation of the signal evolution reduces the computational burden by reducing the number of Fourier transformations. Also, the low rank approximation improves the conditioning of the problem, which is further improved by extending the low rank inverse problem to an augmented Lagrangian that is solved by the alternating direction method of multipliers (ADMM). The root mean square error and the noise propagation are analyzed in simulations. For verification, in vivo examples are provided.
Results
The proposed low rank ADMM approach shows a reduced root mean square error compared to the original fingerprinting reconstruction, to a low rank approximation alone and to an ADMM approach without a low rank approximation. Incorporating sensitivity encoding allows for further artifact reduction.
Conclusion
The proposed reconstruction provides robust convergence, reduced computational burden and improved image quality compared to other MRF reconstruction approaches evaluated in this study.
△ Less
Submitted 22 November, 2016; v1 submitted 24 August, 2016;
originally announced August 2016.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Local-Oscillator Noise Coupling in Balanced Homodyne Readout for Advanced Gravitational Wave Detectors
Authors:
Sebastian Steinlechner,
Bryan W Barr,
Angus S Bell,
Stefan L Danilishin,
Andreas Gläfke,
Christian Gräf,
Jan-Simon Hennig,
E Alasdair Houston,
Sabina H Huttner,
Sean S Leavey,
Daniela Pascucci,
Borja Sorazu,
Andrew Spencer,
Kenneth A Strain,
Jennifer Wright,
Stefan Hild
Abstract:
The second generation of interferometric gravitational wave detectors are quickly approaching their design sensitivity. For the first time these detectors will become limited by quantum back-action noise. Several back-action evasion techniques have been proposed to further increase the detector sensitivity. Since most proposals rely on a flexible readout of the full amplitude- and phase-quadrature…
▽ More
The second generation of interferometric gravitational wave detectors are quickly approaching their design sensitivity. For the first time these detectors will become limited by quantum back-action noise. Several back-action evasion techniques have been proposed to further increase the detector sensitivity. Since most proposals rely on a flexible readout of the full amplitude- and phase-quadrature space of the output light field, balanced homodyne detection is generally expected to replace the currently used DC readout. Up to now, little investigation has been undertaken into how balanced homodyne detection can be successfully transferred from its ubiquitous application in table-top quantum optics experiments to large-scale interferometers with suspended optics. Here we derive implementation requirements with respect to local oscillator noise couplings and highlight potential issues with the example of the Glasgow Sagnac Speed Meter experiment, as well as for a future upgrade to the Advanced LIGO detectors.
△ Less
Submitted 24 June, 2015;
originally announced June 2015.
-
Design of a speed meter interferometer proof-of-principle experiment
Authors:
C. Gräf,
B. W. Barr,
A. S. Bell,
F. Campbell,
A. V. Cumming,
S. L. Danilishin,
N. A. Gordon,
G. D. Hammond,
J. Hennig,
E. A. Houston,
S. H. Huttner,
R. A. Jones,
S. S. Leavey,
H. Lück,
J. Macarthur,
M. Marwick,
S. Rigby,
R. Schilling,
B. Sorazu,
A. Spencer,
S. Steinlechner,
K. A. Strain,
S. Hild
Abstract:
The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of develo…
▽ More
The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of development are being pursued to reach this goal, focusing both on modifications of the well-established Michelson detector configuration and development of different detector topologies. In this paper, we present the design of the world's first Sagnac speed meter interferometer which is currently being constructed at the University of Glasgow. With this proof-of-principle experiment we aim to demonstrate the theoretically predicted lower quantum noise in a Sagnac interferometer compared to an equivalent Michelson interferometer, to qualify Sagnac speed meters for further research towards an implementation in a future generation large scale gravitational wave detector, such as the planned Einstein Telescope observatory.
△ Less
Submitted 11 September, 2014; v1 submitted 12 May, 2014;
originally announced May 2014.
-
Fully pseudospectral time evolution and its application to 1+1 dimensional physical problems
Authors:
Jörg Hennig
Abstract:
It was recently demonstrated that time-dependent PDE problems can numerically be solved with a fully pseudospectral scheme, i.e. using spectral expansions with respect to both spatial and time directions (Hennig and Ansorg, 2009 [15]). This was done with the example of simple scalar wave equations in Minkowski spacetime. Here we show that the method can be used to study interesting physical proble…
▽ More
It was recently demonstrated that time-dependent PDE problems can numerically be solved with a fully pseudospectral scheme, i.e. using spectral expansions with respect to both spatial and time directions (Hennig and Ansorg, 2009 [15]). This was done with the example of simple scalar wave equations in Minkowski spacetime. Here we show that the method can be used to study interesting physical problems that are described by systems of nonlinear PDEs. To this end we consider two 1+1 dimensional problems: radial oscillations of spherically symmetric Newtonian stars and time evolution of Gowdy spacetimes as particular cosmological models in general relativity.
△ Less
Submitted 16 December, 2012; v1 submitted 18 April, 2012;
originally announced April 2012.