Development of RFSoC-based direct sampling highly multiplexed microwave SQUID readout for future CMB and submillimeter surveys
Authors:
Chao Liu,
Zeeshan Ahmed,
Shawn W. Henderson,
Ryan Herbst,
Larry Ruckman,
Thomas Satterthwaite
Abstract:
The SLAC Microresonator Radio Frequency (SMuRF) electronics is being deployed as the readout for the Cosmic Microwave Background (CMB) telescopes of the Simons Observatory (SO). A Radio Frequency System-on-Chip (RFSoC) based readout of microwave frequency resonator based cryogenic sensors is under development at SLAC as an upgrade path for SMuRF with simplified RF hardware, a more compact footprin…
▽ More
The SLAC Microresonator Radio Frequency (SMuRF) electronics is being deployed as the readout for the Cosmic Microwave Background (CMB) telescopes of the Simons Observatory (SO). A Radio Frequency System-on-Chip (RFSoC) based readout of microwave frequency resonator based cryogenic sensors is under development at SLAC as an upgrade path for SMuRF with simplified RF hardware, a more compact footprint, and lower total power consumption. The high-speed integrated data converters and digital data path in RFSoC enable direct RF sampling without analog up and down conversion for RF frequencies up to 6 GHz. A comprehensive optimization and characterization study has been performed for direct RF sampling for microwave SQUID multiplexers, which covers noise level, RF dynamic range, and linearity using a prototype implementation. The SMuRF firmware, including the implementation of closed-loop tone tracking, has been ported to the RFSoC platform and interfaced with the quadrature mixers for digital up and down conversion in the data converter data path to realize a full microwave SQUID multiplexer readout. In this paper, a selection of the performance characterization results of direct RF sampling for microwave SQUID multiplexer readout will be summarized and compared with science-driven requirements. Preliminary results demonstrating the read out of cryogenic sensors using the prototype system will also be presented here. We anticipate our new RFSoC-based SMuRF system will be an enabling readout for on-going and future experiments in astronomy and cosmology, which rely on large arrays of cryogenic sensors to achieve their science goals.
△ Less
Submitted 18 June, 2024;
originally announced June 2024.
-
Higher Order Nyquist Zone Sampling with RFSoC Data Converters for Astronomical and High Energy Physics Readout Systems
Authors:
Chao Liu,
Zeeshan Ahmed,
Shawn W. Henderson,
Ryan Herbst,
Larry Ruckman
Abstract:
From generation to generation, the maximum RF frequency and sampling rate of the integrated data converters in RF system-on-chip (RFSoC) family devices from Xilinx increases significantly. With the integrated digital mixers and up and down conversion blocks in the datapaths of the data converters, those RFSoC devices offer the capability for implementing a full readout system of ground and space-b…
▽ More
From generation to generation, the maximum RF frequency and sampling rate of the integrated data converters in RF system-on-chip (RFSoC) family devices from Xilinx increases significantly. With the integrated digital mixers and up and down conversion blocks in the datapaths of the data converters, those RFSoC devices offer the capability for implementing a full readout system of ground and space-based telescopes and detectors across the electromagnetic spectrum within the devices with minimum or no analog mixing circuit. In this paper, we present the characterization results for the the data converters sampling at higher orders of Nyquist zones to extend the frequency range covered for our targeted readout systems of microwave-frequency resonator-based cryogenic detector and multiplexer systems and other astronomical and high-energy physics instrumentation applications, such as, axion search and dark matter detection. The initial evaluation of the data converters operating higher order Nyquist zones covers two-tones and comb of tones tests to address the concerns in the RF inter-modulation distortion, which is the key performance index for our targeted applications. The characterization of the data converters is performed in the bandwidth of 4-6 GHz and results meet our requirements. The settings and operating strategies of the data converters for our targeted applications will be summarised.
△ Less
Submitted 14 September, 2023;
originally announced September 2023.
-
Quantum metrology of low frequency electromagnetic modes with frequency upconverters
Authors:
Stephen E. Kuenstner,
Elizabeth C. van Assendelft,
Saptarshi Chaudhuri,
Hsiao-Mei Cho,
Jason Corbin,
Shawn W. Henderson,
Fedja Kadribasic,
Dale Li,
Arran Phipps,
Nicholas M. Rapidis,
Maria Simanovskaia,
Jyotirmai Singh,
Cyndia Yu,
Kent D. Irwin
Abstract:
We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the Very High Frequency band (VHF) ($\lesssim$300MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode…
▽ More
We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the Very High Frequency band (VHF) ($\lesssim$300MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode in the microwave C Band ($\sim$ 5GHz), analogous to the radiation pressure interaction between electromagnetic and mechanical modes in cavity optomechanics. We analyze RQU performance with quantum amplifier theory, and show that the RQU can operate as a quantum-limited op-amp in this frequency range. It can also use non-classical measurement protocols equivalent to those used in cavity optomechanics, including back-action evading (BAE) measurements, sideband cooling, and two-mode squeezing. These protocols enable experiments using dc--VHF electromagnetic modes as quantum sensors with sensitivity better than the Standard Quantum Limit (SQL). We demonstrate signal upconversion from low frequencies to microwave C band using an RQU and show a phase-sensitive gain (extinction ratio) of $46.9$\;dB, which is a necessary step towards the realization of full BAE.
△ Less
Submitted 12 July, 2024; v1 submitted 11 October, 2022;
originally announced October 2022.
-
SLAC Microresonator RF (SMuRF) Electronics: A tone-tracking readout system for superconducting microwave resonator arrays
Authors:
Cyndia Yu,
Zeeshan Ahmed,
Josef C. Frisch,
Shawn W. Henderson,
Max Silva-Feaver,
Kam Arnold,
David Brown,
Jake Connors,
Ari J. Cukierman,
J. Mitch D'Ewart,
Bradley J. Dober,
John E. Dusatko,
Gunther Haller,
Ryan Herbst,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Chao-Lin Kuo,
John A. B. Mates,
Larry Ruckman,
Joel Ullom,
Leila Vale,
Daniel D. Van Winkle,
Jesus Vasquez,
Edward Young
Abstract:
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems such as microwave SQUID multiplexers ($μ$mux) or microwave kinetic inductance detectors (MKIDs). Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arr…
▽ More
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems such as microwave SQUID multiplexers ($μ$mux) or microwave kinetic inductance detectors (MKIDs). Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4-8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. We focus in particular on the case of large channel count, low bandwidth applications, but the system has been easily reconfigured for high bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.
△ Less
Submitted 22 August, 2022;
originally announced August 2022.
-
Phase Drift Monitoring for Tone Tracking Readout of Superconducting Microwave Resonators
Authors:
Max Silva-Feaver,
Zeeshan Ahmed,
Kam Arnold,
Josef C. Frisch,
John Groh,
Shawn W. Henderson,
Jesus Vasquez,
Cyndia Yu
Abstract:
A number of modern millimeter, sub-millimeter, and far-infrared detectors are read out using superconducting microwave (1-10GHz) resonators. The main detector technologies are Transition Edge Sensors, read out using Microwave SQUID Multiplexers ($μ$mux) and Microwave Kinetic Inductance Detectors. In these readout schemes, sky signal is encoded as resonance frequency changes. One way to interrogate…
▽ More
A number of modern millimeter, sub-millimeter, and far-infrared detectors are read out using superconducting microwave (1-10GHz) resonators. The main detector technologies are Transition Edge Sensors, read out using Microwave SQUID Multiplexers ($μ$mux) and Microwave Kinetic Inductance Detectors. In these readout schemes, sky signal is encoded as resonance frequency changes. One way to interrogate these superconducting resonators is to calibrate the probe tone phase such that any sky signal induced frequency shifts from the resonators show up primarily as voltage changes in only one of the two quadratures of the interrogation tone. However, temperature variations in the operating environment produce phase drifts that degrade the phase calibration and can source low frequency noise in the final detector time ordered data if left to drift too far from optimal calibration. We present a method for active software monitoring of the time delay through the system which could be used to feedback on the resonator probe tone calibration angle or to apply an offline cleaning. We implement and demonstrate this monitoring method using the SLAC Microresonator RF Electronics on a 65 channel $μ$mux chip from NIST.
△ Less
Submitted 4 August, 2022;
originally announced August 2022.
-
Conceptual Design of the Modular Detector and Readout System for the CMB-S4 survey experiment
Authors:
D. R. Barron,
Z. Ahmed,
J. Aguilar,
A. J. Anderson,
C. F. Baker,
P. S. Barry,
J. A. Beall,
A. N. Bender,
B. A. Benson,
R. W. Besuner,
T. W. Cecil,
C. L. Chang,
S. C. Chapman,
G. E. Chesmore,
G. Derylo,
W. B. Doriese,
S. M. Duff,
T. Elleflot,
J. P. Filippini,
B. Flaugher,
J. G. Gomez,
P. K. Grimes,
R. Gualtieri,
I. Gullett,
G. Haller
, et al. (25 additional authors not shown)
Abstract:
We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental…
▽ More
We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over a wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4's science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 square meters of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
A simulation suite for readout with SMuRF tone-tracking electronics
Authors:
Cyndia Yu,
Zeeshan Ahmed,
J. Mitch D'Ewart,
Josef C. Frisch,
Shawn W. Henderson,
Max Silva-Feaver
Abstract:
We present the details of a simulation suite for modeling the effects of readout with SLAC Microresonator RF (SMuRF) electronics. The SMuRF electronics are a warm readout and control system for use with superconducting microwave resonator-based detector systems. The system has been used with the BICEP/Keck program and will be used on the upcoming Simons Observatory and BICEP Array experiments. Thi…
▽ More
We present the details of a simulation suite for modeling the effects of readout with SLAC Microresonator RF (SMuRF) electronics. The SMuRF electronics are a warm readout and control system for use with superconducting microwave resonator-based detector systems. The system has been used with the BICEP/Keck program and will be used on the upcoming Simons Observatory and BICEP Array experiments. This simulation suite is a software implementation of the main SMuRF algorithms for offline analysis, modeling, and study. The firmware-implemented algorithms for calibration, resonator frequency estimation, and tone tracking present sources of potential bias or errors if not modeled properly. The simulator takes as input true detector signal, realistic resonator properties, and SMuRF-related user-controlled readout settings. It returns the final flux ramp-demodulated output of a detector timestream as would be passed to the experiment data acquisition system, enabling the analysis of the impact of readout-related parameters on the final science data. It is publicly available in Python with accompanying Jupyter notebooks for user tutorials.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
Bandwidth and Aliasing in the Microwave SQUID Multiplexer
Authors:
Cyndia Yu,
Zeeshan Ahmed,
Jake A. Connors,
J. Mitch D'Ewart,
Bradley Dober,
Josef C. Frisch,
Shawn W. Henderson,
Gene C. Hilton,
Johannes Hubmayr,
Stephen E. Kuenstner,
J. A. Ben Mates,
Maximiliano Silva-Feaver,
Joel N. Ullom,
Leila R. Vale,
Dan Van Winkle,
Edward Young
Abstract:
The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts.…
▽ More
The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts. Since the multiplexer is considered for both bolometric and calorimetric applications across several orders of magnitude of signal frequencies, understanding the bandwidth of the device and its interaction with readout electronics is key to appropriately designing and engineering systems. Here we discuss several important factors contributing to the bandwidth properties of umux systems, including the intrinsic device bandwidth, interactions with warm electronics readout systems, and aliasing. We present simulations and measurements of umux devices coupled with SLAC Microresonator RF (SMuRF) tone-tracking electronics and discuss several implications for future experimental design.
△ Less
Submitted 17 June, 2022;
originally announced June 2022.
-
Faraday rotation study of plasma bubbles in GeV wakefield accelerators
Authors:
Y. Y. Chang,
X. Cheng,
A. Hannasch,
M. LaBerge,
J. M. Shaw,
K. Weichman,
J. Welch,
A. Bernstein,
W. Henderson,
R. Zgadzaj,
M. C. Downer
Abstract:
We visualize plasma bubbles driven by 0.67 PW laser pulses in plasma of density $n_e \approx 5\times10^{17}$ ${\rm cm}^{-3}$ by imaging Faraday rotation patterns imprinted on linearly-polarized probe pulses of wavelength $λ_{pr} = 1.05 μ$m and duration $τ_{pr} = 2$ ps or $1$ ps that cross the bubble's path at right angles. When the bubble captures and accelerates tens to hundreds of pC of electron…
▽ More
We visualize plasma bubbles driven by 0.67 PW laser pulses in plasma of density $n_e \approx 5\times10^{17}$ ${\rm cm}^{-3}$ by imaging Faraday rotation patterns imprinted on linearly-polarized probe pulses of wavelength $λ_{pr} = 1.05 μ$m and duration $τ_{pr} = 2$ ps or $1$ ps that cross the bubble's path at right angles. When the bubble captures and accelerates tens to hundreds of pC of electron charge, we observe two parallel streaks of length $cτ_{pr}$ straddling the drive pulse propagation axis, separated by $\sim45$ $μ$m, in which probe polarization rotates by $0.3^\circ$ to more than $5^\circ$ in opposite directions. Accompanying simulations show that they result from Faraday rotation within portions of dense bubble side walls that are pervaded by the azimuthal magnetic field of accelerating electrons during the probe transit across the bubble. Analysis of the width of the streaks shows that quasi-monoenergetic high-energy electrons and trailing lower energy electrons inside the bubble contribute distinguishable portions of the observed signals, and that relativistic flow of sheath electrons suppresses Faraday rotation from the rear of the bubble. The results demonstrate favorable scaling of Faraday rotation diagnostics to $40\times$ lower plasma density than previously demonstrated.
△ Less
Submitted 23 September, 2021;
originally announced September 2021.
-
Observation of Plasma Bubble Structures in a GeV Laser-Plasma Accelerator
Authors:
Yen-Yu Chang,
Kathleen Weichman,
Xiantao Cheng,
Joseph M. Shaw,
James Welch,
Maxwell LaBerge,
Andrea Hannasch,
Rafal Zgadzaj,
Aaron Bernstein,
Watson Henderson,
Michael C. Downer
Abstract:
We measure characteristics of plasma bubbles in GeV-class laser-plasma accelerators (LPAs) using Faraday rotation diagnostics. We extend these techniques, previously demonstrated for LPAs in atmospheric density plasmas (electron density $n_e >10^{19}$ cm$^{-3}$), to LPAs in low-density plasmas ($n_e \approx 5\times10^{17}$ cm$^{-3}$), in which plasma bubbles are $\sim 5$ times larger, and correspo…
▽ More
We measure characteristics of plasma bubbles in GeV-class laser-plasma accelerators (LPAs) using Faraday rotation diagnostics. We extend these techniques, previously demonstrated for LPAs in atmospheric density plasmas (electron density $n_e >10^{19}$ cm$^{-3}$), to LPAs in low-density plasmas ($n_e \approx 5\times10^{17}$ cm$^{-3}$), in which plasma bubbles are $\sim 5$ times larger, and correspondingly easier to visualize in detail. The signals show $\approx 0.5^\circ$ rotation streaks of opposite sign separated by $\sim50$ $μ$m, consistent with bubble diameter; no on-axis rotation; streaks length consistent with transverse probe pulse duration ($180$ $μ$m for $500$ fs pulse length, and $600$ $μ$m for $2$ ps pulse length). We utilized an anamorphic imaging system to obtain a wide longitudinal field of view ($>1$ cm) and a high transverse resolution ($<9$ $μ$m). We also demonstrated that Faraday rotation signals are sensitive to the stages of acceleration processes using extended 2D Finite Difference Time Domain (FDTD) simulation.
△ Less
Submitted 5 November, 2019; v1 submitted 3 October, 2017;
originally announced October 2017.
-
Bright 5 - 85 MeV Compton gamma-ray pulses from GeV laser-plasma accelerator and plasma mirror
Authors:
J. M. Shaw,
A. C. Bernstein,
R. Zgadzaj,
A. Hannasch,
M. LaBerge,
Y. Y. Chang,
K. Weichman,
J. Welch,
W. Henderson,
H. -E. Tsai,
N. Fazel,
X. Wang,
T. Ditmire,
M. Donovan,
G. Dyer,
E. Gaul,
J. Gordon,
M. Martinez,
M. Spinks,
T. Toncian,
C. Wagner,
M. C. Downer
Abstract:
We convert a GeV laser-plasma electron accelerator into a compact femtosecond-pulsed $γ$-ray source by inserting a $100 μ$m-thick glass plate $\sim3$ cm after the accelerator exit. With near-unity reliability, and requiring only crude alignment, this glass plasma mirror retro-reflected spent drive laser pulses (photon energy $\hbarω_L = 1.17$ eV) with $>50\%$ efficiency back onto trailing electron…
▽ More
We convert a GeV laser-plasma electron accelerator into a compact femtosecond-pulsed $γ$-ray source by inserting a $100 μ$m-thick glass plate $\sim3$ cm after the accelerator exit. With near-unity reliability, and requiring only crude alignment, this glass plasma mirror retro-reflected spent drive laser pulses (photon energy $\hbarω_L = 1.17$ eV) with $>50\%$ efficiency back onto trailing electrons (peak Lorentz factor $1000 < γ_e < 4400$), creating an optical undulator that generated $\sim10^8 γ$-ray photons with sub-mrad divergence, estimated peak brilliance $\sim10^{21}$ photons/s/mm$^2$/mrad$^2$/$0.1\%$ bandwidth and negligible bremsstrahlung background. The $γ$-ray photon energy $E_γ= 4γ_e^2 \hbarω_L$, inferred from the measured $γ_e$ on each shot, peaked from 5 to 85 MeV, spanning a range otherwise available with comparable brilliance only from large-scale GeV-linac-based high-intensity $γ$-ray sources.
△ Less
Submitted 24 May, 2017;
originally announced May 2017.
-
Compact tunable Compton x-ray source from laser-plasma accelerator and plasma mirror
Authors:
Hai-En Tsai,
Xiaoming Wang,
Joseph Shaw,
Zhengyan Li,
Alexey V. Arefiev,
Xi Zhang,
Rafal Zgadzaj,
Watson Henderson,
V. Khudik,
G. Shvets,
M. C. Downer
Abstract:
We present an in-depth experimental-computational study of the parameters necessary to optimize a tunable, quasi-monoenergetic, efficient, low-background Compton backscattering (CBS) x-ray source that is based on the self-aligned combination of a laser-plasma accelerator (LPA) and a plasma mirror (PM). The main findings are: (1) an LPA driven in the blowout regime by 30 TW, 30 fs laser pulses prod…
▽ More
We present an in-depth experimental-computational study of the parameters necessary to optimize a tunable, quasi-monoenergetic, efficient, low-background Compton backscattering (CBS) x-ray source that is based on the self-aligned combination of a laser-plasma accelerator (LPA) and a plasma mirror (PM). The main findings are: (1) an LPA driven in the blowout regime by 30 TW, 30 fs laser pulses producesnot only a high-quality, tunable, quasi-monoenergetic electron beam, but also a high-quality, relativistically intense (a0~1) spent drive pulse that remains stable in profile and intensity over the LPA tuning range. (2) A thin plastic film near the gas jet exit retro-reflects the spent drive pulse efficiently into oncoming electrons to produce CBS x-rays without detectable bremsstrahlung background. Meanwhile anomalous far-field divergence of the retro-reflected light demonstrates relativistic "denting" of the PM. Exploiting these optimized LPA and PM conditions, we demonstrate quasi-monoenergetic (50% FWHM energy spread), tunable (75 to 200 KeV) CBS x-rays, characteristics previously achieved only on more powerful laser systems by CBS of a split-off, counter-propagating pulse. Moreover, laser-to-x-ray photon conversion efficiency ~6e12 exceeds that of any previous LPA-based quasi-monoenergetic Compton source. Particle-in-cell simulations agree well with the measurements.
△ Less
Submitted 14 January, 2015; v1 submitted 8 November, 2014;
originally announced November 2014.
-
The H1 Forward Track Detector at HERA II
Authors:
P. J. Laycock,
R. C. W. Henderson,
S. J. Maxfield,
J. V. Morris,
G. D. Patel,
D. P. C. Sankey
Abstract:
In order to maintain efficient tracking in the forward region of H1 after the luminosity upgrade of the HERA machine, the H1 Forward Track Detector was also upgraded. While much of the original software and techniques used for the HERA I phase could be reused, the software for pattern recognition was completely rewritten. This, along with several other improvements in hit finding and high-level tr…
▽ More
In order to maintain efficient tracking in the forward region of H1 after the luminosity upgrade of the HERA machine, the H1 Forward Track Detector was also upgraded. While much of the original software and techniques used for the HERA I phase could be reused, the software for pattern recognition was completely rewritten. This, along with several other improvements in hit finding and high-level track reconstruction, are described in detail together with a summary of the performance of the detector.
△ Less
Submitted 2 August, 2012; v1 submitted 18 June, 2012;
originally announced June 2012.