-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and develo** detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.
-
A Comparative Study of Straight-Strip and Zigzag-Interleaved Anode Patterns for MPGD Readouts
Authors:
C. Perez-Lara,
S. Aune,
B. Azmoun,
K. Dehmelt,
A. Deshpande,
W. Fan,
P. Garg,
T. K. Hemmick,
M. Kebbiri,
A. Kiselev,
I. Mandjavidze,
M. L. Purschke,
M. Revolle,
M. Vandenbroucke,
C. Woody
Abstract:
Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring pads. However, to effectively extract the inherent p…
▽ More
Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring pads. However, to effectively extract the inherent positional information, the lateral spacing of the straight pads must be significantly smaller than the extent of the charge cloud. In contrast, highly interleaved anode patterns, such as zigzags, can adequately sample the charge with a pitch comparable to the size of the charge cloud or even larger. This has the considerable advantage of providing the same performance while requiring far fewer instrumented channels. Additionally, the geometric parameters defining such zigzag structures may be tuned to provide a uniform detector response without the need for so-called pad response functions, while simultaneously maintaining excellent position resolution. We have measured the position resolution of a variety of zigzag shaped anode patterns optimized for various MPGDs, including GEM, Micromegas, and micro-RWELL and compared this performance to the same detectors equipped with straight pads of varying pitch. We report on the performance results of each readout structure, evaluated under identical conditions in a test beam.
△ Less
Submitted 28 January, 2021;
originally announced January 2021.
-
Passive Gating Grid for Ion Back Flow Suppression in High Luminosity Collider Experiments
Authors:
K. Dehmelt,
P. Garg,
T. K. Hemmick,
A. Milov,
E. Shulga,
V. Zakharov
Abstract:
Time Projection Chamber (TPC) is one of the main tracking systems for many current and future collider experiments at RHIC and LHC. It has a capability to measure the space points of charged tracks for good momentum resolution as well as the energy loss (dE/dx) for particle identification with good energy resolution. Both of these features depend strongly on the amount of space charge in the TPC g…
▽ More
Time Projection Chamber (TPC) is one of the main tracking systems for many current and future collider experiments at RHIC and LHC. It has a capability to measure the space points of charged tracks for good momentum resolution as well as the energy loss (dE/dx) for particle identification with good energy resolution. Both of these features depend strongly on the amount of space charge in the TPC gas volume, mainly due to the ions from the amplification stage. An active gating grid has been used thus far to gate the electrons and ions by switching the polarities of the grid wires. Therefore, active gating does introduce a limitation for data taking rates in high luminosity collisions. In this work we propose several options of a passive gating, where a significant reduction of Ion Back Flow (IBF) is possible in a high luminosity environment without any dead time issues due to gating operation. Particularly, the application of a TPC passive gating for the sPHENIX experiment at RHIC is presented, which is currently under development.
△ Less
Submitted 27 December, 2019;
originally announced December 2019.
-
Results from a Prototype Combination TPC Cherenkov Detector with GEM Readout
Authors:
B. Azmoun,
K. Dehmelt,
T. K. Hemmick,
R. Majka,
H. N. Nguyen,
M. Phipps,
M. L. Purschke,
N. Ram,
W. Roh,
D. Shangase,
N. Smirnov,
C. Woody,
A. Zhang
Abstract:
A combination Time Projection Chamber-Cherenkov prototype detector has been developed as part of the Detector R&D Program for a future Electron Ion Collider. The prototype was tested at the Fermilab test beam facility to provide a proof of principle to demonstrate that the detector is able to measure particle tracks and provide particle identification information within a common detector volume. T…
▽ More
A combination Time Projection Chamber-Cherenkov prototype detector has been developed as part of the Detector R&D Program for a future Electron Ion Collider. The prototype was tested at the Fermilab test beam facility to provide a proof of principle to demonstrate that the detector is able to measure particle tracks and provide particle identification information within a common detector volume. The TPC portion consists of a 10x10x10cm3 field cage, which delivers charge from tracks to a 10x10cm2 quadruple GEM readout. Tracks are reconstructed by interpolating the hit position of clusters on an array of 2x10mm2 zigzag pads The Cherenkov component consists of a 10x10cm2 readout plane segmented into 3x3 square pads, also coupled to a quadruple GEM. As tracks pass though the drift volume of the TPC, the generated Cherenkov light is able to escape through sparsely arranged wires making up one side of the field cage, facing the CsI photocathode of the Cherenkov detector. The Cherenkov detector is thus operated in a windowless, proximity focused configuration for high efficiency. Pure CF4 is used as the working gas for both detector components, mainly due to its transparency into the deep UV, as well as its high N0. Results from the beam test, as well as results on its particle id capabilities will be discussed.
△ Less
Submitted 26 April, 2019;
originally announced April 2019.
-
Design Studies for a TPC Readout Plane Using Zigzag Patterns with Multistage GEM Detectors
Authors:
B. Azmoun,
P. Garg,
T. K. Hemmick,
M. Hohlmann,
A. Kiselev,
M. L. Purschke,
C. Woody,
A. Zhang
Abstract:
A new Time Projection Chamber (TPC) is currently under development for the sPHENIX experiment at RHIC. The TPC will be read out using multistage GEM detectors on each end and will be divided into approximately 40 pad layers in radius. Each pad layer is required to provide a spatial resolution of ~250 microns, which must be achieved with a minimal channel count in order to minimize the overall cost…
▽ More
A new Time Projection Chamber (TPC) is currently under development for the sPHENIX experiment at RHIC. The TPC will be read out using multistage GEM detectors on each end and will be divided into approximately 40 pad layers in radius. Each pad layer is required to provide a spatial resolution of ~250 microns, which must be achieved with a minimal channel count in order to minimize the overall cost of the detector. The current proposal is to make the pads into a zigzag shape in order to enhance charge sharing among neighboring pads. This will allow for the possibility to interpolate the hit position to high precision, resulting in a position resolution many times better than the 2mm pitch of the readout pads. This paper discusses various simulation studies that were carried out to optimize the size and shape of the zigzag pads for the readout board for the TPC, along with the technical challenges in fabricating it. It also describes the performance of the first prototype readout board obtained from measurements carried out in the laboratory using a highly collimated X-ray source.
△ Less
Submitted 8 January, 2018;
originally announced January 2018.
-
A Magnetic Field Cloak For Charged Particle Beams
Authors:
K. Capobianco-Hogan,
R. Cervantes,
A. Deshpande,
N. Feege,
T. Krahulik,
J. LaBounty,
R. Sekelsky,
A. Adhyatman,
G. Arrowsmith-Kron,
B. Coe,
K. Dehmelt,
T. K. Hemmick,
S. Jeffas,
T. LaByer,
S. Mahmud,
A. Oliveira,
A. Quadri,
K. Sharma,
A. Tishelman-Charny
Abstract:
Shielding charged particle beams from transverse magnetic fields is a common challenge for particle accelerators and experiments. We demonstrate that a magnetic field cloak is a viable solution. It allows for the use of dipole magnets in the forward regions of experiments at an Electron Ion Collider (EIC) and other facilities without interfering with the incoming beams. The dipoles can improve the…
▽ More
Shielding charged particle beams from transverse magnetic fields is a common challenge for particle accelerators and experiments. We demonstrate that a magnetic field cloak is a viable solution. It allows for the use of dipole magnets in the forward regions of experiments at an Electron Ion Collider (EIC) and other facilities without interfering with the incoming beams. The dipoles can improve the momentum measurements of charged final state particles at angles close to the beam line and therefore increase the physics reach of these experiments. In contrast to other magnetic shielding options (such as active coils), a cloak requires no external powering. We discuss the design parameters, fabrication, and limitations of a magnetic field cloak and demonstrate that cylinders made from 45 layers of YBCO high-temperature superconductor, combined with a ferromagnetic shell made from epoxy and stainless steel powder, shield more than 99% of a transverse magnetic field of up to 0.45 T (95 % shielding at 0.5 T) at liquid nitrogen temperature. The ferromagnetic shell reduces field distortions caused by the superconductor alone by 90% at 0.45 T.
△ Less
Submitted 20 November, 2017; v1 submitted 6 July, 2017;
originally announced July 2017.
-
Performance of a Quintuple-GEM Based RICH Detector Prototype
Authors:
M. Blatnik,
K. Dehmelt,
A. Deshpande,
D. Dixit,
N. Feege,
T. K. Hemmick,
B. Lewis,
M. L. Purschke,
W. Roh,
F. Torales-Acosta,
T. Videbaek,
S. Zajac
Abstract:
Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must perform well at high high laboratory momenta. For the upcoming Electron Ion Collider (EIC), the physics goals require hadron ($π$, K, p) identification up to $\sim$~5…
▽ More
Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must perform well at high high laboratory momenta. For the upcoming Electron Ion Collider (EIC), the physics goals require hadron ($π$, K, p) identification up to $\sim$~50 GeV/c. In this region Cerenkov Ring-Imaging is the most viable solution.\newline The speed of light in a radiator medium is inversely proportional to the refractive index. Hence, for PID reaching out to high momenta a small index of refraction is required. Unfortunately, the lowest indices of refraction also result in the lowest light yield ($\frac{dN_γ}{dx} \propto \sin^2{\left(θ_C \right)}$) driving up the radiator length and thereby the overall detector cost. In this paper we report on a successful test of a compact RICH detector (1 meter radiator) capable of delivering in excess of 10 photoelectrons per ring with a low index radiator gas ($CF_4$). The detector concept is a natural extension of the PHENIX HBD detector achieved by adding focusing capability at low wavelength and adequate gain for high efficiency detection of single-electron induced avalanches. Our results indicate that this technology is indeed a viable choice in the forward direction of the EIC. The setup and results are described within.
△ Less
Submitted 27 June, 2016; v1 submitted 14 January, 2015;
originally announced January 2015.
-
Two-pion correlations in Au+Au collisions at 10.8 GeV/c per nucleon
Authors:
E877 Collaboration,
J. Barrette,
R. Bellwied,
S. Bennett,
R. Bersch,
P. Braun-Munzinger,
W. C. Chang,
W. E. Cleland,
J. D. Cole,
T. M. Cormier,
G. David,
J. Dee,
O. Dietzsch,
M. W. Drigert,
S. Gilbert,
J. R. Hall,
T. K. Hemmick,
N. Herrmann,
B. Hong,
C. L. Jiang,
S. C. Johnson,
Y. Kwon,
R. Lacasse,
A. Lukaszew,
Q. Li
, et al. (26 additional authors not shown)
Abstract:
Two-particle correlation functions for positive and negative pions have been measured in Au+Au collisions at 10.8~GeV/c per nucleon. The data were analyzed using one- and three-dimensional correlation functions. From the results of the three-dimensional fit the phase space density of pions was calculated. It is consistent with local thermal equilibrium.
Two-particle correlation functions for positive and negative pions have been measured in Au+Au collisions at 10.8~GeV/c per nucleon. The data were analyzed using one- and three-dimensional correlation functions. From the results of the three-dimensional fit the phase space density of pions was calculated. It is consistent with local thermal equilibrium.
△ Less
Submitted 7 February, 1997;
originally announced February 1997.