-
Achieving a Near-Ideal Silicon Crystal Neutron Interferometer using Sub-Micron Fabrication Techniques
Authors:
M. G. Huber,
I. Taminiau,
D. G. Cory,
B. Heacock,
D. Sarenac,
R. Valdillez,
D. A. Pushin
Abstract:
Perfect-crystal neutron interferometry which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degre…
▽ More
Perfect-crystal neutron interferometry which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degree of dimensional tolerance as well as being relatively defect-free with minimal internal stresses. In the past, perfect-crystal neutron interferometers have been produced by a two step process. First, a resin diamond wheel would be used to remove excess material and shape the interferometer. Afterword, the crystal would be etched in order to remove surface defects and elevate strains. This process has had limitations in terms of repeatability and in maximizing the final contrast, or fringe visibility, of the interferometer. We have tested various fabrication and post-fabrication techniques on a single perfect-crystal neutron interferometer and measured the interferometer's performance at each step. Here we report a robust, repeatable non-etching fabrication process with high final contrast. For the interferometer used in this work, we achieved contrasts of greater than 90% several separate times and ultimately finished with an interferometer that has 92% contrast and a uniform phase distribution.
△ Less
Submitted 25 February, 2024;
originally announced February 2024.
-
Next-generation high transmission neutron optical devices utilizing micro-machined structures
Authors:
C. Kapahi,
D. Sarenac,
M. Bleuel,
D. G. Cory,
B. Heacock,
M. Henderson,
M. G. Huber,
I. Taminiau,
D. A. Pushin
Abstract:
Neutrons have emerged as a unique probe at the forefront of modern material science, unrivaled in their penetrating abilities. A major challenge stems from the fact that neutron optical devices are limited to refractive indices on the order of $n\approx 1 \pm 10^{-5}$. By exploiting advances in precision manufacturing, we have designed and constructed a micro-meter period triangular grating with a…
▽ More
Neutrons have emerged as a unique probe at the forefront of modern material science, unrivaled in their penetrating abilities. A major challenge stems from the fact that neutron optical devices are limited to refractive indices on the order of $n\approx 1 \pm 10^{-5}$. By exploiting advances in precision manufacturing, we have designed and constructed a micro-meter period triangular grating with a high aspect ratio of $14.3$. The manufacturing quality is demonstrated with white-light interferometric data and microscope imaging. Neutron scattering experiment results are presented, showing agreement to refraction modelling. The capabilities of neutron Fresnel lenses based on this design are contrasted to existing neutron focusing techniques and the path separation of a prism-based neutron interferometer is estimated.
△ Less
Submitted 24 December, 2021;
originally announced December 2021.
-
Optimization of neutron diffraction from phase-gratings
Authors:
B. Heacock,
D. Sarenac,
D. G. Cory,
M. G. Huber,
D. S. Hussey,
C. Kapahi,
H. Miao,
H. Wen,
D. A. Pushin
Abstract:
The recent development of phase-grating moiré neutron interferometry promises a wide range of impactful experiments from dark-field imaging of material microstructure to precise measurements of fundamental constants. However, the contrast of 3 % obtained using this moiré interferometer was well below the theoretical prediction of 30 % using ideal gratings. It is suspected that non-ideal aspects of…
▽ More
The recent development of phase-grating moiré neutron interferometry promises a wide range of impactful experiments from dark-field imaging of material microstructure to precise measurements of fundamental constants. However, the contrast of 3 % obtained using this moiré interferometer was well below the theoretical prediction of 30 % using ideal gratings. It is suspected that non-ideal aspects of the phase-gratings was a leading contributor to this deficiency and that phase-gratings needed to be quantitatively assessed and optimized. Here we characterize neutron diffraction from phase-gratings using Bragg diffraction crystals to determine the optimal phase-grating orientations. We show well-defined diffraction peaks and explore perturbations to the diffraction peaks and the effects on interferometer contrast as a function of grating alignment. This technique promises to improve the contrast of the grating interferometers by providing in-situ aides to grating alignment.
△ Less
Submitted 13 November, 2018;
originally announced December 2018.
-
Sub-micrometer resolution neutron tomography
Authors:
B. Heacock,
D. Sarenac,
D. G. Cory,
M. G. Huber,
J. P. W. MacLean,
H. Miao,
H. Wen,
D. A. Pushin
Abstract:
We demonstrate a neutron tomography technique with sub-micrometer spatial resolution. Our method consists of measuring neutron diffraction spectra using a double crystal diffractometer as a function of sample rotation and then using a phase retrieval algorithm followed by tomographic reconstruction to generate a density map of the sample. In this first demonstration, silicon phase-gratings are use…
▽ More
We demonstrate a neutron tomography technique with sub-micrometer spatial resolution. Our method consists of measuring neutron diffraction spectra using a double crystal diffractometer as a function of sample rotation and then using a phase retrieval algorithm followed by tomographic reconstruction to generate a density map of the sample. In this first demonstration, silicon phase-gratings are used as samples, the periodic structure of which allows the shape of the gratings to be imaged without the need of position sensitive detectors. Topological features found in the reconstructions also appear in scanning electron micrographs. The reconstructions have a resolution of about 300 nm, which is over an order of magnitude smaller than the resolution of radiographic, phase contrast, differential phase contrast, and dark field neutron tomography methods. Further optimization of the underlying phase recovery and tomographic reconstruction algorithm is also considered.
△ Less
Submitted 22 August, 2018;
originally announced August 2018.
-
Increased interference fringe visibility from the post fabrication heat treatment of a perfect crystal silicon neutron interferometer
Authors:
Benjamin Heacock,
Muhammad Arif,
David G Cory,
Thomas Gnaupel-Herold,
Robert Williamson Haun,
Michael G. Huber,
Michelle Elizabeth Jamer,
Joachim Nsofini,
Dmitry A Pushin,
Dusan Sarenac,
Ivar A. J. Taminiau,
Albert Young
Abstract:
Construction of silicon neutron interferometers requires a perfect crystal silicon ingot (5 cm to 30 cm long) be machined such that Bragg diffracting "blades" protrude from a common base. Leaving the interferometer blades connected to the same base preserves Bragg plane alignment, but if the interferometer contains crystallographic misalignments of greater than about 10 nrad between the blades, in…
▽ More
Construction of silicon neutron interferometers requires a perfect crystal silicon ingot (5 cm to 30 cm long) be machined such that Bragg diffracting "blades" protrude from a common base. Leaving the interferometer blades connected to the same base preserves Bragg plane alignment, but if the interferometer contains crystallographic misalignments of greater than about 10 nrad between the blades, interference fringe visibility begins to suffer. Additionally, the parallelism, thickness, and distance between the blades must be machined to micron tolerances. Traditionally, interferometers do not exhibit usable interference fringe visibility until 30 $μ$m to 60 $μ$m of machining surface damage is chemically etched away. However, if too much material is removed, the uneven etch rates across the interferometer cause the shape of the crystal blades to be outside of the required tolerances. As a result, the ultimate interference fringe visibility varies widely among neutron interferometers that are created under similar conditions. We find that annealing a previously etched interferometer at $800^\circ \mathrm{C}$ dramatically increased interference fringe visibility from 23 % to 90 %. The Bragg plane misalignments were also measured before and after annealing using neutron rocking curve interference peaks, showing that Bragg plane alignment was improved across the interferometer after annealing. This suggests that current interferometers with low fringe visibility may be salvageable and that annealing may become an important step in the fabrication process of future neutron interferometers, leading to less need for chemical etching and larger, more exotic neutron interferometers.
△ Less
Submitted 17 October, 2017;
originally announced October 2017.
-
Three Phase-Grating Moire Neutron Interferometer for Large Interferometer Area Applications
Authors:
D. Sarenac,
D. A. Pushin,
M. G. Huber,
D. S. Hussey,
H. Miao,
M. Arif,
D. G. Cory,
A. D. Cronin,
B. Heacock,
D. L. Jacobson,
J. M. LaManna,
H. Wen
Abstract:
We demonstrate a three phase-grating neutron interferometer as a robust candidate for large area interferometry applications and characterization of materials. This novel far-field moire technique allows for broad wavelength acceptance and relaxed requirements related to fabrication and alignment, circumventing the main obstacles associated with perfect crystal neutron interferometry. Interference…
▽ More
We demonstrate a three phase-grating neutron interferometer as a robust candidate for large area interferometry applications and characterization of materials. This novel far-field moire technique allows for broad wavelength acceptance and relaxed requirements related to fabrication and alignment, circumventing the main obstacles associated with perfect crystal neutron interferometry. Interference fringes were observed with a total interferometer length of four meters, and the effects of an aluminum 6061 alloy sample on the coherence of the system was examined. Experiments to measure the autocorrelation length of samples and the universal gravitational constant are proposed and discussed.
△ Less
Submitted 17 August, 2017;
originally announced August 2017.
-
Decoupling of a Neutron Interferometer from Temperature Gradients
Authors:
Parminder Saggu,
Taisiya Mineeva,
Muhammad Arif,
David Cory,
Robert Haun,
Ben Heacock,
Michael Huber,
Ke Li,
Joachim Nsofini,
Dusan Sarenac,
Chandra Shahi,
Vladimir Skavysh,
William Snow,
Samuel Werner,
Albert Young,
Dmitriy Pushin
Abstract:
Neutron interferometry enables precision measurements that are typically operated within elaborate, multi-layered facilities which provide substantial shielding from environmental noise. These facilities are necessary to maintain the coherence requirements in a perfect crystal neutron interferometer which is extremely sensitive to local environmental conditions such as temperature gradients across…
▽ More
Neutron interferometry enables precision measurements that are typically operated within elaborate, multi-layered facilities which provide substantial shielding from environmental noise. These facilities are necessary to maintain the coherence requirements in a perfect crystal neutron interferometer which is extremely sensitive to local environmental conditions such as temperature gradients across the interferometer, external vibrations, and acoustic waves. The ease of operation and breadth of applications of perfect crystal neutron interferometry would greatly benefit from a mode of operation which relaxes these stringent isolation requirements. Here, the INDEX Collaboration and National Institute of Standards and Technology demonstrates the functionality of a neutron interferometer in vacuum and characterize the use of a compact vacuum chamber enclosure as a means to isolate the interferometer from spatial temperature gradients and time-dependent temperature fluctuations. The vacuum chamber is found to have no depreciable effect on the performance of the interferometer (contrast) while improving system stability, thereby showing that it is feasible to replace large temperature isolation and control systems with a compact vacuum enclosure for perfect crystal neutron interferometry.
△ Less
Submitted 29 November, 2016;
originally announced November 2016.
-
Neutron Limit on the Strongly-Coupled Chameleon Field
Authors:
K. Li,
M. Arif,
D. G. Cory,
R. Haun,
B. Heacock,
M. G. Huber,
J. Nsofini,
D. A. Pushin,
P. Saggu,
D. Sarenac,
C. B. Shahi,
V. Skavysh,
W. M. Snow,
A. R. Young
Abstract:
The physical origin of the dark energy that causes the accelerated expansion rate of the universe is one of the major open questions of cosmology. One set of theories postulates the existence of a self-interacting scalar field for dark energy coupling to matter. In the chameleon dark energy theory, this coupling induces a screening mechanism such that the field amplitude is nonzero in empty space…
▽ More
The physical origin of the dark energy that causes the accelerated expansion rate of the universe is one of the major open questions of cosmology. One set of theories postulates the existence of a self-interacting scalar field for dark energy coupling to matter. In the chameleon dark energy theory, this coupling induces a screening mechanism such that the field amplitude is nonzero in empty space but is greatly suppressed in regions of terrestrial matter density. However measurements performed under appropriate vacuum conditions can enable the chameleon field to appear in the apparatus, where it can be subjected to laboratory experiments. Here we report the most stringent upper bound on the free neutron-chameleon coupling in the strongly-coupled limit of the chameleon theory using neutron interferometric techniques. Our experiment sought the chameleon field through the relative phase shift it would induce along one of the neutron paths inside a perfect crystal neutron interferometer. The amplitude of the chameleon field was actively modulated by varying the millibar pressures inside a dual-chamber aluminum cell. We report a 95% confidence level upper bound on the neutron-chameleon coupling $β$ ranging from $β< 4.7\times 10^6$ for a Ratra-Peebles index of n = 1 in the nonlinear scalar field potential to $β< 2.4\times 10^7$ for n = 6, one order of magnitude more sensitive than the most recent free neutron limit for intermediate n. Similar experiments can explore the full parameter range for chameleon dark energy in the foreseeable future.
△ Less
Submitted 26 January, 2016;
originally announced January 2016.