-
Radiopurity of NaI(Tl) crystals for PICOLON dark matter experiment
Authors:
K. Kotera,
D. Chernyak,
H. Ejiri,
K. Fushimi,
K. Hata,
R. Hazama,
T. Iida,
H. Ikeda,
K. Imagawa,
K. Inoue,
H. Ito,
T. Kishimoto,
M. Koga,
A. Kozlov,
K. Nakamura,
R. Orito,
T. Shima,
Y. Takemoto,
S. Umehara,
Y. Urano,
K. Yasuda,
S. Yoshida
Abstract:
The dark matter observation claim by the DAMA/LIBRA collaboration has been a long-standing puzzle within the particle physics community. Efforts of other research groups to verify the claim have been insufficient by significant radioactivity of present NaI(Tl) crystals. PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neut(ra)lino) experiment conducts independent search for Weakly Intera…
▽ More
The dark matter observation claim by the DAMA/LIBRA collaboration has been a long-standing puzzle within the particle physics community. Efforts of other research groups to verify the claim have been insufficient by significant radioactivity of present NaI(Tl) crystals. PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neut(ra)lino) experiment conducts independent search for Weakly Interacting Massive Particles (WIMPs) using NaI(Tl) crystals. Our NaI(Tl) crystal manufactured in 2020 (Ingot #85) reached the same purity level as DAMA/LIBRA crystals. In this report, we describe the radiopurity of the new Ingot #94 crystal produced using the same purification technique as Ingot #85. The $α$-ray events were selected by pulse-shape discrimination method. The impurities in the Ingot #94, $^{232}$Th, $^{226}$Ra and $^{210}$Po radioactivity were $4.6\pm 1.2~\mathrm{μBq/kg}$, $7.9\pm 4.4~\mathrm{μBq/kg}$, and $19\pm 6~\mathrm{μBq/kg}$, which are equivalent to those of the DAMA/LIBRA crystals. The background rate in the energy region of 2-6 keV , was 2-5 events/d/kg/keV without applying a veto trigger.
△ Less
Submitted 25 September, 2023;
originally announced September 2023.
-
PICOLON dark matter search project
Authors:
K. Fushimi,
D. Chernyak,
H. Ejiri,
K. Hata,
R. Hazama,
T. Iida,
H. Ikeda,
K. Imagawa,
K. Inoue,
H. Ishiura,
H. Ito,
T. Kishimoto,
M. Koga,
K. Kotera,
A. Kozlov,
K. Nakamura,
R. Orito,
T. Shima,
Y. Takemoto,
S. Umehara,
Y. Urano,
Y. Yamamoto,
K. Yasuda,
S. Yoshida
Abstract:
PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neutr(al)ino) aims to search for cosmic dark matter by high purity NaI(Tl) scintillator. We developed extremely pure NaI(Tl) crystal by hybrid purification method. The recent result of $^{210}$Pb in our NaI(Tl) is less than 5.7 $μ$Bq/kg. We will report the test experiment in the low-background measurement at Kamioka Underground Laboratory.…
▽ More
PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neutr(al)ino) aims to search for cosmic dark matter by high purity NaI(Tl) scintillator. We developed extremely pure NaI(Tl) crystal by hybrid purification method. The recent result of $^{210}$Pb in our NaI(Tl) is less than 5.7 $μ$Bq/kg. We will report the test experiment in the low-background measurement at Kamioka Underground Laboratory. The sensitivity for annual modulating signals and finding dark matter particles will be discussed.
△ Less
Submitted 19 December, 2021;
originally announced December 2021.
-
Dark matter search with high purity NaI(Tl) scintillator
Authors:
K. Fushimi,
Y. Kanemitsu,
K. Kotera,
D. Chernyak,
H. Ejiri,
K. Hata,
R. Hazama,
T. Iida,
H. Ikeda,
K. Imagawa,
K. Inoue,
H. Ishiura,
H. Ito,
T. Kisimoto,
M. Koga,
A. Kozlov,
K. Nakamura,
R. Orito,
T. Shima,
Y. Takemoto,
S. Umehara,
Y. Urano,
K. Yasuda,
S. Yoshida
Abstract:
A dark matter search project needs and extremely low background radiation detector since the expected event rate of dark matter is less than a few events in one year in one tonne of the detector mass. The authors developed a highly radiopure NaI(Tl) crystal to search for dark matter. The best combination of the purification methods was developed, resulting $^{\mathrm{nat}}$K and $^{210}$Pb were le…
▽ More
A dark matter search project needs and extremely low background radiation detector since the expected event rate of dark matter is less than a few events in one year in one tonne of the detector mass. The authors developed a highly radiopure NaI(Tl) crystal to search for dark matter. The best combination of the purification methods was developed, resulting $^{\mathrm{nat}}$K and $^{210}$Pb were less than 20 ppb and 5.7 $μ$Bq/kg, respectively.
The authors will construct a large volume detector system with high-purity NaI(Tl) crystals. The design and the performance of the prototype detector module will be reported in this article.
△ Less
Submitted 29 June, 2021;
originally announced June 2021.
-
Development of highly radiopure NaI(Tl) scintillator for PICOLON dark matter search project
Authors:
K. Fushimi,
Y. Kanemitsu,
S. Hirata,
D. Chernyak,
R. Hazama,
H. Ikeda,
K. Imagawa,
H. Ishiura,
H. Ito,
T. Kisimoto,
A. Kozlov,
Y. Takemoto,
K. Yasuda,
H. Ejiri,
K. Hata,
T. Iida,
K. Inoue,
M. Koga,
K. Nakamura,
R. Orito,
T. Shima,
S. Umehara,
S. Yoshida
Abstract:
The highly radiopure NaI(Tl) was developed to search for particle candidates of dark matter. The optimized methods were combined to reduce various radioactive impurities. The $^{40}$K was effectively reduced by the re-crystallization method. The progenies of the decay chains of uranium and thorium were reduced by appropriate resins. The concentration of natural potassium in NaI(Tl) crystal was red…
▽ More
The highly radiopure NaI(Tl) was developed to search for particle candidates of dark matter. The optimized methods were combined to reduce various radioactive impurities. The $^{40}$K was effectively reduced by the re-crystallization method. The progenies of the decay chains of uranium and thorium were reduced by appropriate resins. The concentration of natural potassium in NaI(Tl) crystal was reduced down to 20 ppb. Concentrations of alpha-ray emitters were successfully reduced by appropriate selection of resin. The present concentration of thorium series and 226Ra were $1.2 \pm1.4$ $μ$Bq/kg and $13\pm4$ $μ$Bq/kg, respectively. No significant excess in the concentration of $^{210}$Pb was obtained, and the upper limit was 5.7 $μ$Bq/kg at 90% C. L. The achieved level of radiopurity of NaI(Tl) crystals makes construction of a dark matter detector possible.
△ Less
Submitted 20 May, 2021; v1 submitted 3 January, 2021;
originally announced January 2021.
-
A study on energy resolution of CANDLES detector
Authors:
B. T. Khai,
S. Ajimura,
W. M. Chan,
K. Fushimi,
R. Hazama,
H. Hiraoka,
T. Iida,
K. Kanagawa,
H. Kino,
T. Kishimoto,
T. Maeda,
K. Nakajima,
M. Nomachi,
I. Ogawa,
T. Ohata,
K. Suzuki,
Y. Takemoto,
Y. Takihira,
Y. Tamagawa,
M. Tozawa,
M. Tsuzuki,
S. Umehara,
S. Yoshida
Abstract:
In a neutrinoless double-beta decay ($0νββ$) experiment, energy resolution is important to distinguish between $0νββ$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0νββ$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value…
▽ More
In a neutrinoless double-beta decay ($0νββ$) experiment, energy resolution is important to distinguish between $0νββ$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0νββ$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value of $^{48}$Ca, the current energy resolution (2.6%) exceeds the ideal statistical fluctuation of the number of photoelectrons (1.6%). Because of CaF$_2$'s long decay constant of 1000 ns, a signal integration within 4000 ns is used to calculate the energy. The baseline fluctuation ($σ_{baseline}$) is accumulated in the signal integration, thus degrading the energy resolution. This paper studies $σ_{baseline}$ in the CANDLES detector, which severely degrades the resolution by 1% at the Q-value of $^{48}$Ca. To avoid $σ_{\rm baseline}$, photon counting can be used to obtain the number of photoelectrons in each PMT; however, a significant photoelectron signal overlap** probability in each PMT causes missing photoelectrons in counting and reduces the energy resolution. "Partial photon counting" reduces $σ_{baseline}$ and minimizes photoelectron loss. We obtain improved energy resolutions of 4.5-4.0% at 1460.8 keV ($γ$-ray of $^{40}$K), and 3.3-2.9% at 2614.5 keV ($γ$-ray of $^{208}$Tl). The energy resolution at the Q-value is estimated to be improved from 2.6% to 2.2%, and the detector sensitivity for the $0νββ$ half-life of $^{48}$Ca can be improved by 1.09 times.
△ Less
Submitted 28 January, 2021; v1 submitted 24 September, 2020;
originally announced September 2020.
-
Low background measurement in CANDLES-III for studying the neutrino-less double beta decay of $^{48}$Ca
Authors:
S. Ajimura,
W. M. Chan,
K. Ichimura,
T. Ishikawa,
K. Kanagawa,
B. T. Khai,
T. Kishimoto,
H. Kino,
T. Maeda,
K. Matsuoka,
N. Nakatani,
M. Nomachi,
M. Saka,
K. Seki,
Y. Takemoto,
Y. Takihira,
D. Tanaka,
M. Tanaka,
K. Tetsuno,
V. T. T. Trang,
M. Tsuzuki,
S. Umehara,
K. Akutagawa,
T. Batpurev,
M. Doihara
, et al. (44 additional authors not shown)
Abstract:
We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal background…
▽ More
We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal backgrounds caused by the radioactive impurities within the CaF$_2$ crystals can be reduced effectively through analysis of the signal pulse shape. We analyzed the data obtained in the Kamioka underground for a live-time of 130.4\,days to evaluate the feasibility of the low background measurement with the CANDLES-III detector. Using Monte Carlo simulations, we estimated the background rate from the radioactive impurities in the CaF$_{2}$ crystals and the rate of high energy $γ$-rays caused by the (n, $γ$) reactions induced by environmental neutrons. The expected background rate was in a good agreement with the measured rate, i.e., approximately 10$^{-3}$ events/keV/yr/(kg of $^{\rm nat.}$Ca), in the 0$νββ$ window. In conclusion, the background candidates were estimated properly by comparing the measured energy spectrum with the background simulations. With this measurement method, we performed the first search for 0$νββ$ decay in a low background condition using a detector with a Ca isotope, in which the Ca present was not enriched, in a scale of hundreds of kg. The $^{48}$Ca isotope has a high potential for use in 0$νββ$ decay search, and is expected to be useful for the development of a next-generation detector for highly sensitive measurements.
△ Less
Submitted 19 April, 2021; v1 submitted 20 August, 2020;
originally announced August 2020.
-
The energy calibration system for CANDLES using (n, γ) reaction
Authors:
T. Iida,
K. Mizukoshi,
T. Ohata,
T. Uehara,
T. Batpurev,
W. M. Chan,
K. Fushimi,
R. Hazama,
M. Ishikawa,
H. Kakubata,
K. Kanagawa,
S. Katagiri,
B. T. Khai,
T. Kishimoto,
X. Li,
T. Maeda,
K. Matsuoka,
K. Morishita,
M. Moser,
K. Nakajima,
M. Nomachi,
I. Ogawa,
M. Shokati,
K. Suzuki,
Y. Takemoto
, et al. (6 additional authors not shown)
Abstract:
CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of…
▽ More
CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of a standard high-energy $γ$-ray source. Therefore, we have developed a novel calibration system based on $γ$-ray emission by neutron capture on $^{28}$Si, $^{56}$Fe and $^{58}$Ni nuclei. In the paper, we report the development of the new calibration system as well as the results of energy calibration in CANDLES up to 9 MeV.
△ Less
Submitted 26 March, 2020;
originally announced March 2020.
-
The search for neutron-antineutron oscillations at the Sudbury Neutrino Observatory
Authors:
SNO Collaboration,
B. Aharmim,
S. N. Ahmed,
A. E. Anthony,
N. Barros,
E. W. Beier,
A. Bellerive,
B. Beltran,
M. Bergevin,
S. D. Biller,
K. Boudjemline,
M. G. Boulay,
B. Cai,
Y. D. Chan,
D. Chauhan,
M. Chen,
B. T. Cleveland,
G. A. Cox,
X. Dai,
H. Deng,
J. A. Detwiler,
P. J. Doe,
G. Doucas,
P. -L. Drouin,
F. A. Duncan
, et al. (100 additional authors not shown)
Abstract:
Tests on $B-L$ symmetry breaking models are important probes to search for new physics. One proposed model with $Δ(B-L)=2$ involves the oscillations of a neutron to an antineutron. In this paper a new limit on this process is derived for the data acquired from all three operational phases of the Sudbury Neutrino Observatory experiment. The search was concentrated in oscillations occurring within t…
▽ More
Tests on $B-L$ symmetry breaking models are important probes to search for new physics. One proposed model with $Δ(B-L)=2$ involves the oscillations of a neutron to an antineutron. In this paper a new limit on this process is derived for the data acquired from all three operational phases of the Sudbury Neutrino Observatory experiment. The search was concentrated in oscillations occurring within the deuteron, and 23 events are observed against a background expectation of 30.5 events. These translate to a lower limit on the nuclear lifetime of $1.48\times 10^{31}$ years at 90% confidence level (CL) when no restriction is placed on the signal likelihood space (unbounded). Alternatively, a lower limit on the nuclear lifetime was found to be $1.18\times 10^{31}$ years at 90% CL when the signal was forced into a positive likelihood space (bounded). Values for the free oscillation time derived from various models are also provided in this article. This is the first search for neutron-antineutron oscillation with the deuteron as a target.
△ Less
Submitted 1 May, 2017;
originally announced May 2017.
-
Search for cosmic dark matter by means of ultra high purity NaI(Tl) scintillator
Authors:
K. Fushimi,
D. Chernyak,
H. Ejiri,
R. Hazama,
S. Hirata,
H. Ikeda,
K. Inoue,
K. Imagawa,
G. Kanzaki,
A. Kozlov,
R. Orito,
T. Shima,
Y. Takemoto,
Y. Teraoka,
S. Umehara,
S. Yoshida
Abstract:
The dark matter search project by means of ultra high purity NaI(Tl) scintillator is now underdevelopment. An array of large volume NaI(Tl) detectors whose volume is 12.7 cm$φ\times$12.7 cm is applied to search for dark matter signal. To remove radioactive impurities in NaI(Tl) crystal is one of the most important task to find small number of dark matter signals. We have developed high purity NaI(…
▽ More
The dark matter search project by means of ultra high purity NaI(Tl) scintillator is now underdevelopment. An array of large volume NaI(Tl) detectors whose volume is 12.7 cm$φ\times$12.7 cm is applied to search for dark matter signal. To remove radioactive impurities in NaI(Tl) crystal is one of the most important task to find small number of dark matter signals. We have developed high purity NaI(Tl) crystal which contains small amounts of radioactive impurities, $<4$ ppb of $^{nat}$K, 0.3 ppt of Th chain, 58 $μ$Bq/kg of $^{226}$Ra and 30 $μ$Bq/kg of $^{210}$Pb. Future prospects to search for dark matter by means of a large volume and high purity NaI(Tl) scintillator is discussed.
△ Less
Submitted 28 April, 2017;
originally announced May 2017.
-
High purity NaI(Tl) scintillator to search for dark matter
Authors:
Ken-Ichi Fushimi,
Hiroyasu Ejiri,
Ryuta Hazama,
Haruo Ikeda,
Kunio Inoue,
Kyoshiro Imagawa,
Gakuji Kanzaki,
Alexandre Kozlov,
Reiko Orito,
Tatsushi Shima,
Yasuhiro Takemoto,
Yuri Teraoka,
Saori Umehara,
Sei Yoshida
Abstract:
A high purity and large volume NaI(Tl) scintillator was developed to search for cosmic dark matter. The required densities of radioactive impurities (RIs) such as U-chain, Th-chain are less than a few ppt to establish high sensitivity to dark matter. The impurity of RIs were effectively reduced by selecting raw materials of crucible and by performing chemical reduction of lead ion in NaI raw powde…
▽ More
A high purity and large volume NaI(Tl) scintillator was developed to search for cosmic dark matter. The required densities of radioactive impurities (RIs) such as U-chain, Th-chain are less than a few ppt to establish high sensitivity to dark matter. The impurity of RIs were effectively reduced by selecting raw materials of crucible and by performing chemical reduction of lead ion in NaI raw powder. The impurity of $^{226}$Ra was reduced less than 100 $μ$Bq/kg in NaI(Tl) crystal. It should be remarked that the impurity of $^{210}$Pb, which is difficult to reduce, is effectively reduced by chemical processing of NaI raw powder down to less than 30 $μ$Bq/kg. The expected sensitivity to cosmic dark matter by using 250 kg of the high purity and large volume NaI(Tl) scintillator (PICO-LON; Pure Inorganic Crystal Observatory for LOw-background Neutr(al)ino) is 7$\times$10$^{-45}$ cm$^{2}$ for 50 GeV$/c^{2}$ WIMPs.
△ Less
Submitted 16 May, 2016;
originally announced May 2016.
-
Dark matter search project PICO-LON
Authors:
K. Fushimi,
H. Ejiri,
R. Hazama,
H. Ikeda,
K. Imagawa,
K. Inoue,
G. Kanzaki,
A. Kozlov,
R. Orito,
T. Shima,
Y. Takemoto,
Y. Teraoka,
S. Umehara,
K. Yasuda,
S. Yoshida
Abstract:
The PICO-LON project aims at search for cold dark matter by means of highly radio-pure and large volume NaI(Tl) scintillator. The NaI powder was purifed by chemical processing to remove lead isotopes and selecting a high purity graphite crucible. The concentrations of radioactive impurities of $^{226}$Ra and $^{228}$Th were effectively reduced to 58$\pm$4 $μ$Bq/kg and 1.5$\pm$1.9 $μ$Bq/kg, respect…
▽ More
The PICO-LON project aims at search for cold dark matter by means of highly radio-pure and large volume NaI(Tl) scintillator. The NaI powder was purifed by chemical processing to remove lead isotopes and selecting a high purity graphite crucible. The concentrations of radioactive impurities of $^{226}$Ra and $^{228}$Th were effectively reduced to 58$\pm$4 $μ$Bq/kg and 1.5$\pm$1.9 $μ$Bq/kg, respectively. It should be remarked that the concentration of $^{210}$Pb, which is crucial for the sensitivity to dark matter, was reduced to 24$\pm$2 $μ$Bq/kg. The total background rate at 10 keVee was as low as 8 keV$^{-1}$kg$^{-1}$day$^{-1}$, which was sufficiently low to search for dark matter. Further purification of NaI(Tl) ingot and future prospect of PICO-LON project is discussed.
△ Less
Submitted 14 December, 2015;
originally announced December 2015.
-
The Majorana Parts Tracking Database
Authors:
The Majorana Collaboration,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
V. Brudanin,
M. Busch,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. Esterline,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (67 additional authors not shown)
Abstract:
The Majorana Demonstrator is an ultra-low background physics experiment searching for the neutrinoless double beta decay of $^{76}$Ge. The Majorana Parts Tracking Database is used to record the history of components used in the construction of the Demonstrator. The tracking implementation takes a novel approach based on the schema-free database technology CouchDB. Transportation, storage, and proc…
▽ More
The Majorana Demonstrator is an ultra-low background physics experiment searching for the neutrinoless double beta decay of $^{76}$Ge. The Majorana Parts Tracking Database is used to record the history of components used in the construction of the Demonstrator. The tracking implementation takes a novel approach based on the schema-free database technology CouchDB. Transportation, storage, and processes undergone by parts such as machining or cleaning are linked to part records. Tracking parts provides a great logistics benefit and an important quality assurance reference during construction. In addition, the location history of parts provides an estimate of their exposure to cosmic radiation. A web application for data entry and a radiation exposure calculator have been developed as tools for achieving the extreme radio-purity required for this rare decay search.
△ Less
Submitted 5 February, 2015;
originally announced February 2015.
-
KamLAND-PICO project to search for cosmic dark matter
Authors:
K. Fushimi,
Y. Awatani,
H. Ejiri,
R. Hazama,
H. Ikeda,
K. Imagawa,
K. Inoue,
A. Kozlov,
R. Orito,
T. Shima,
R. Sugawaraand K. Yasuda
Abstract:
KamLAND-PICO project aims to search for WIMPs dark matter by means of NaI(Tl) scintillator. To investigate the WIMPs candidate whose cross section is as small as $10^{-9}$ pb, a pure NaI(Tl) crystal was developed by chemical processing and taking care of surroundings. The concentration of U and Th chain was reduced to $5.4\pm0.9$ ppt and $3.3\pm2.2$ ppt, respectively. It should be remarked that th…
▽ More
KamLAND-PICO project aims to search for WIMPs dark matter by means of NaI(Tl) scintillator. To investigate the WIMPs candidate whose cross section is as small as $10^{-9}$ pb, a pure NaI(Tl) crystal was developed by chemical processing and taking care of surroundings. The concentration of U and Th chain was reduced to $5.4\pm0.9$ ppt and $3.3\pm2.2$ ppt, respectively. It should be remarked that the concentration of $^{210}$Pb which was difficult to reduce reached to the high purity as $58\pm26$ $μ$Bq/kg.
△ Less
Submitted 14 July, 2014;
originally announced July 2014.
-
A Dark Matter Search with MALBEK
Authors:
G. K. Giovanetti,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (62 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76-Ge and perform a search for weakly interacting massive particles (WIMPs) with masses below 10 GeV. As part of the MAJORANA research and development efforts, we have deployed a modified, low-background broad energy germanium detector at the Kimb…
▽ More
The MAJORANA DEMONSTRATOR is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76-Ge and perform a search for weakly interacting massive particles (WIMPs) with masses below 10 GeV. As part of the MAJORANA research and development efforts, we have deployed a modified, low-background broad energy germanium detector at the Kimballton Underground Research Facility. With its sub-keV energy threshold, this detector is sensitive to potential non-Standard Model physics, including interactions with WIMPs. We discuss the backgrounds present in the WIMP region of interest and explore the impact of slow surface event contamination when searching for a WIMP signal.
△ Less
Submitted 8 July, 2014;
originally announced July 2014.
-
Background Model for the Majorana Demonstrator
Authors:
C. Cuesta,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (63 additional authors not shown)
Abstract:
The Majorana Collaboration is constructing a system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale in the inverted-hierarchy region. To realize this, a major goal of the Majorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in th…
▽ More
The Majorana Collaboration is constructing a system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale in the inverted-hierarchy region. To realize this, a major goal of the Majorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in the 4 keV region of interest around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials with analytical methods for background rejection, for example using powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using simulations of the different background components whose purity levels are constrained from radioassay measurements.
△ Less
Submitted 6 May, 2014;
originally announced May 2014.
-
Testing the Ge detectors for the MAJORANA DEMONSTRATOR
Authors:
W. Xu,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (62 additional authors not shown)
Abstract:
High purity germanium (HPGe) crystals will be used for the MAJORANA DEMONSTRATOR, where they serve as both the source and the detector for neutrinoless double beta decay. It is crucial for the experiment to understand the performance of the HPGe crystals. A variety of crystal properties are being investigated, including basic properties such as energy resolution, efficiency, uniformity, capacitanc…
▽ More
High purity germanium (HPGe) crystals will be used for the MAJORANA DEMONSTRATOR, where they serve as both the source and the detector for neutrinoless double beta decay. It is crucial for the experiment to understand the performance of the HPGe crystals. A variety of crystal properties are being investigated, including basic properties such as energy resolution, efficiency, uniformity, capacitance, leakage current and crystal axis orientation, as well as more sophisticated properties, e.g. pulse shapes and dead layer and transition layer distributions. In this paper, we will present our measurements that characterize the HPGe crystals. We will also discuss our simulation package for the detector characterization setup, and show that additional information can be extracted from data-simulation comparisons.
△ Less
Submitted 29 April, 2014;
originally announced April 2014.
-
Status of the MAJORANA DEMONSTRATOR experiment
Authors:
MAJORANA Collaboration,
R. D. Martin,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. Esterline,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (60 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR neutrinoless double beta-decay experiment is currently under construction at the Sanford Underground Research Facility in South Dakota, USA. An overview and status of the experiment are given.
The MAJORANA DEMONSTRATOR neutrinoless double beta-decay experiment is currently under construction at the Sanford Underground Research Facility in South Dakota, USA. An overview and status of the experiment are given.
△ Less
Submitted 13 November, 2013;
originally announced November 2013.
-
The {\sc Majorana Demonstrator} Neutrinoless Double-Beta Decay Experiment
Authors:
Majorana Collaboration,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. Esterline,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri,
G. K. Giovanetti
, et al. (60 additional authors not shown)
Abstract:
The {\sc Majorana Demonstrator will search for the neutrinoless double-beta decay of the isotope Ge-76 with a mixed array of enriched and natural germanium detectors. The observation of this rare decay would indicate the neutrino is its own antiparticle, demonstrate that lepton number is not conserved, and provide information on the absolute mass scale of the neutrino. The {\sc Demonstrator} is be…
▽ More
The {\sc Majorana Demonstrator will search for the neutrinoless double-beta decay of the isotope Ge-76 with a mixed array of enriched and natural germanium detectors. The observation of this rare decay would indicate the neutrino is its own antiparticle, demonstrate that lepton number is not conserved, and provide information on the absolute mass scale of the neutrino. The {\sc Demonstrator} is being assembled at the 4850-foot level of the Sanford Underground Research Facility in Lead, South Dakota. The array will be situated in a low-background environment and surrounded by passive and active shielding. Here we describe the science goals of the {\sc Demonstrator} and the details of its design.
△ Less
Submitted 7 August, 2013;
originally announced August 2013.
-
The MAJORANA DEMONSTRATOR: A Search for Neutrinoless Double-beta Decay of Germanium-76
Authors:
MAJORANA Collaboration,
S. R. Elliott,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
J. Esterline,
J. E. Fast,
P. Finnerty,
F. M. Fraenkleo,
A. Galindo-Uribarri,
G. K. Giovanetti
, et al. (58 additional authors not shown)
Abstract:
The {\sc Majorana} collaboration is searching for neutrinoless double beta decay using $^{76}$Ge, which has been shown to have a number of advantages in terms of sensitivities and backgrounds. The observation of neutrinoless double-beta decay would show that lepton number is violated and that neutrinos are Majorana particles and would simultaneously provide information on neutrino mass. Attaining…
▽ More
The {\sc Majorana} collaboration is searching for neutrinoless double beta decay using $^{76}$Ge, which has been shown to have a number of advantages in terms of sensitivities and backgrounds. The observation of neutrinoless double-beta decay would show that lepton number is violated and that neutrinos are Majorana particles and would simultaneously provide information on neutrino mass. Attaining sensitivities for neutrino masses in the inverted hierarchy region, $15 - 50$ meV, will require large, tonne-scale detectors with extremely low backgrounds, at the level of $\sim$1 count/t-y or lower in the region of the signal. The {\sc Majorana} collaboration, with funding support from DOE Office of Nuclear Physics and NSF Particle Astrophysics, is constructing the {\sc Demonstrator}, an array consisting of 40 kg of p-type point-contact high-purity germanium (HPGe) detectors, of which $\sim$30 kg will be enriched to 87% in $^{76}$Ge. The {\sc Demonstrator} is being constructed in a clean room laboratory facility at the 4850' level (4300 m.w.e.) of the Sanford Underground Research Facility (SURF) in Lead, SD. It utilizes a compact graded shield approach with the inner portion consisting of ultra-clean Cu that is being electroformed and machined underground. The primary aim of the {\sc Demonstrator} is to show the feasibility of a future tonne-scale measurement in terms of backgrounds and scalability.
△ Less
Submitted 29 July, 2013;
originally announced July 2013.
-
Characteristics of Signals Originating Near the Lithium-Diffused N+ Contact of High Purity Germanium P-Type Point Contact Detectors
Authors:
The MAJORANA Collaboration,
E. Aguayo,
M. Amman,
F. T. Avignone III,
A. S. Barabash,
P. J. Barton,
J. R. Beene,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
Y-D. Chan,
C. D. Christofferson,
J. I. Collar,
D. C. Combs,
R. J. Cooper,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. Esterline,
J. E. Fast,
N. Fields
, et al. (61 additional authors not shown)
Abstract:
A study of signals originating near the lithium-diffused n+ contact of p-type point contact (PPC) high purity germanium detectors (HPGe) is presented. The transition region between the active germanium and the fully dead layer of the n+ contact is examined. Energy depositions in this transition region are shown to result in partial charge collection. This provides a mechanism for events with a wel…
▽ More
A study of signals originating near the lithium-diffused n+ contact of p-type point contact (PPC) high purity germanium detectors (HPGe) is presented. The transition region between the active germanium and the fully dead layer of the n+ contact is examined. Energy depositions in this transition region are shown to result in partial charge collection. This provides a mechanism for events with a well defined energy to contribute to the continuum of the energy spectrum at lower energies. A novel technique to quantify the contribution from this source of background is introduced. Experiments that operate germanium detectors with a very low energy threshold may benefit from the methods presented herein.
△ Less
Submitted 28 July, 2012;
originally announced July 2012.
-
The Performance of the Thin NaI(Tl) Detector Pico-Lon for Dark Matter Search
Authors:
K. Harada,
K. Fushimi,
S. Nakayama,
R. Orito,
S. Iida,
S. Ito,
H. Ejiri,
T. Shima,
R. Hazama,
E. Matsumoto,
H. Ito,
K. Imagawa
Abstract:
Thin and large area NaI(Tl) scintillator to search for WIMPs dark matter was developed. The performance of thin and wide area NaI(Tl) showed good enough to search for dark matter. The energy threshold was as low as 2keV and the energy resolution was about 24% in FWHM at 60keV.
Thin and large area NaI(Tl) scintillator to search for WIMPs dark matter was developed. The performance of thin and wide area NaI(Tl) showed good enough to search for dark matter. The energy threshold was as low as 2keV and the energy resolution was about 24% in FWHM at 60keV.
△ Less
Submitted 5 June, 2014; v1 submitted 21 March, 2012;
originally announced March 2012.
-
The Majorana experiment: an ultra-low background search for neutrinoless double-beta decay
Authors:
D. G. Phillips II,
E. Aguayo,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
M. Bergevin,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
Y. -D. Chan,
C. D. Christofferson,
J. I. Collar,
D. C. Combs,
R. J. Cooper,
J. A. Detwiler,
P. J. Doe,
Y. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. Esterline,
J. E. Fast,
N. Fields,
P. Finnerty
, et al. (64 additional authors not shown)
Abstract:
The observation of neutrinoless double-beta decay would resolve the Majorana nature of the neutrino and could provide information on the absolute scale of the neutrino mass. The initial phase of the Majorana experiment, known as the Demonstrator, will house 40 kg of Ge in an ultra-low background shielded environment at the 4850' level of the Sanford Underground Laboratory in Lead, SD. The objectiv…
▽ More
The observation of neutrinoless double-beta decay would resolve the Majorana nature of the neutrino and could provide information on the absolute scale of the neutrino mass. The initial phase of the Majorana experiment, known as the Demonstrator, will house 40 kg of Ge in an ultra-low background shielded environment at the 4850' level of the Sanford Underground Laboratory in Lead, SD. The objective of the Demonstrator is to determine whether a future 1-tonne experiment can achieve a background goal of one count per tonne-year in a narrow region of interest around the 76Ge neutrinoless double-beta decay peak.
△ Less
Submitted 23 November, 2011;
originally announced November 2011.
-
Solubility, Light Output and Energy Resolution Studies of Molybdenum-Loaded Liquid Scintillators
Authors:
V. M. Gehman,
P. J. Doe,
R. G. H. Robertson,
D. I. Will,
H. Ejiri,
R. Hazama
Abstract:
The search for neutrinoless double-beta decay is an important part of the global neutrino physics program. One double-beta decay isotope currently under investigation is 100Mo. In this article, we discuss the results of a feasibility study investigating the use of molybdenum-loaded liquid scintillator. A large, molybdenum-loaded liquid scintillator detector is one potential design for a low-backgr…
▽ More
The search for neutrinoless double-beta decay is an important part of the global neutrino physics program. One double-beta decay isotope currently under investigation is 100Mo. In this article, we discuss the results of a feasibility study investigating the use of molybdenum-loaded liquid scintillator. A large, molybdenum-loaded liquid scintillator detector is one potential design for a low-background, internal-source neutrinoless double-beta decay search with 100Mo. The program outlined in this article included the selection of a solute containing molybdenum, a scintillating solvent and the evaluation of the mixture's performance as a radiation detector.
△ Less
Submitted 3 September, 2010; v1 submitted 11 November, 2009;
originally announced November 2009.