-
Batch VUV4 Characterization for the SBC-LAr10 scintillating bubble chamber
Authors:
H. Hawley-Herrera,
E. Alfonso-Pita,
E. Behnke,
M. Bressler,
B. Broerman,
K. Clark,
J. Corbett,
C. E. Dahl,
K. Dering,
A. de St. Croix,
D. Durnford,
P. Giampa,
J. Hall,
O. Harris,
N. Lamb,
M. Laurin,
I. Levine,
W. H. Lippincott,
X. Liu,
N. Moss,
R. Neilson,
M. -C. Piro,
D. Pyda,
Z. Sheng,
G. Sweeney
, et al. (6 additional authors not shown)
Abstract:
The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10~kg of liquid argon. The VUV4 SiPMs, or Quads, underwent a characterization at two temperatures which measured the breakdown voltage ($V_{\text{BD}}$), the SiPM gain ($g_{\text{SiPM}}$), the rate of change of $g_{\text{SiPM}}$ with re…
▽ More
The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10~kg of liquid argon. The VUV4 SiPMs, or Quads, underwent a characterization at two temperatures which measured the breakdown voltage ($V_{\text{BD}}$), the SiPM gain ($g_{\text{SiPM}}$), the rate of change of $g_{\text{SiPM}}$ with respect to voltage ($m$), the dark count rate (DCR), and the probability of a correlated avalanche (P$_{\text{CA}}$) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to $233.15\pm0.2$~K and $255.15\pm0.2$~K with average stability of $\pm20$~mK. A mostly assumption-free analysis was derived to estimate $V_{\text{BD}}$ to tens of mV precision and DCR close to Poissonian error. The temperature dependence of $V_{\text{BD}}$ was found to be $56\pm2$~mV~K$^{-1}$, and $m$ on average across all Quads was found to be $(459\pm3(\rm{stat.})\pm23(\rm{sys.}))\times 10^{3}~e^-$~PE$^{-1}$~V$^{-1}$. The average DCR temperature coefficient was estimated to be $0.099\pm0.008$~K$^{-1}$ corresponding to a reduction factor of 7 for every 20~K drop in temperature. The average temperature dependence of P$_{\text{CA}}$ was estimated to be $4000\pm1000$~ppm~K$^{-1}$. P$_{\text{CA}}$ estimated from the average across all SiPMs is a better estimator than the P$_{\text{CA}}$ calculated from individual SiPMs, whereas all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
SBC-SNOLAB scintillation system and SiPM implementation for dark matter searches
Authors:
H. Hawley-Herrera
Abstract:
The Scintillating Bubble Chamber (SBC) collaboration is constructing a 10~kg liquid argon (LAr) bubble chamber at SNOLAB called SBC-SNOLAB having the main objective of detecting dark matter. One of the most novel aspects of SBC-SNOLAB is the scintillation system, consisting of LAr doped with on the order of 10~ppm Xe, 48 FBK VUV silicon photomultipliers (SiPMs), the SiPM electronics, two quartz ja…
▽ More
The Scintillating Bubble Chamber (SBC) collaboration is constructing a 10~kg liquid argon (LAr) bubble chamber at SNOLAB called SBC-SNOLAB having the main objective of detecting dark matter. One of the most novel aspects of SBC-SNOLAB is the scintillation system, consisting of LAr doped with on the order of 10~ppm Xe, 48 FBK VUV silicon photomultipliers (SiPMs), the SiPM electronics, two quartz jars, and liquid CF$_4$ used as an hydraulic fluid and additional source of scintillation photons. In contrast with traditional single or dual phase scintillation experiments, the collected LAr scitillation light is used to veto signals which involve the detection of at least a single photoelectron. These proceedings will describe in detail the current SBC-SNOLAB scintillation system which includes the unique design considerations for SBC-SNOLAB that limit the light collection efficiency and the electronics.
△ Less
Submitted 2 December, 2023; v1 submitted 30 September, 2023;
originally announced October 2023.
-
Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$ν$NS Detection
Authors:
E. Alfonso-Pita,
M. Baker,
E. Behnke,
A. Brandon,
M. Bressler,
B. Broerman,
K. Clark,
R. Coppejans,
J. Corbett,
C. Cripe,
M. Crisler,
C. E. Dahl,
K. Dering,
A. de St. Croix,
D. Durnford,
K. Foy,
P. Giampa,
J. Gresl,
J. Hall,
O. Harris,
H. Hawley-Herrera,
C. M. Jackson,
M. Khatri,
Y. Ko,
N. Lamb
, et al. (20 additional authors not shown)
Abstract:
The Scintillating Bubble Chamber (SBC) Collaboration is develo** liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This dev…
▽ More
The Scintillating Bubble Chamber (SBC) Collaboration is develo** liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This device will calibrate the background discrimination power and sensitivity of superheated argon to nuclear recoils at energies down to 100 eV. A second functionally-identical detector with a focus on radiopure construction is being built for SBC's first dark matter search at SNOLAB. The projected spin-independent sensitivity of this search is approximately $10^{-43}$ cm$^2$ at 1 GeV$/c^2$ dark matter particle mass. The scalability and background discrimination power of the liquid-noble bubble chamber make this technique a compelling candidate for future dark matter searches to the solar neutrino fog at 1 GeV$/c^2$ particle mass (requiring a $\sim$ton-year exposure with non-neutrino backgrounds sub-dominant to the solar CE$ν$NS signal) and for high-statistics CE$ν$NS studies at nuclear reactors.
△ Less
Submitted 29 September, 2022; v1 submitted 21 July, 2022;
originally announced July 2022.