A diffuse scattering model of ultracold neutrons on wavy surfaces
Authors:
S. Imajo,
H. Akatsuka,
K. Hatanaka,
T. Higuchi,
G. Ichikawa,
S. Kawasaki,
M. Kitaguchi,
R. Mammei,
R. Matsumiya,
K. Mishima,
R. Picker,
W. Schreyer,
H. M. Shimizu
Abstract:
Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness larger than 5 nm. We therefore d…
▽ More
Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness larger than 5 nm. We therefore developed a scattering model for UCN in which scattering from random surface waviness with a size larger than the UCN wavelength is described by a microfacet Bidirectional Reflectance Distribution Function model (mf-BRDF model), and scattering from smaller structures by the Lambert's cosine law (Lambert model). For the surface waviness, we used the statistical distribution of surface slope measured by an atomic force microscope on a sample piece of guide tube as input of the model. This model was used to describe UCN transmission experiments conducted at the pulsed UCN source at J-PARC. In these experiments, a UCN beam collimated to a divergence angle smaller than $\pm 6^{\circ}$ was directed into a guide tube with a mean-square roughness of 6.4 nm to 17 nm at an oblique angle, and the UCN transport performance and its time-of-flight distribution were measured while changing the angle of incidence. The mf-BRDF model combined with the Lambert model with scattering probability $p_{L} = 0.039\pm0.003$ reproduced the experimental results well. We have thus established a procedure to evaluate the characteristics of UCN guide tubes with a surface roughness of approximately 10 nm.
△ Less
Submitted 30 July, 2023; v1 submitted 27 March, 2023;
originally announced March 2023.
-
The Precision nEDM Measurement with UltraCold Neutrons at TRIUMF
Authors:
Ryohei Matsumiya,
Hiroaki Akatsuka,
Chris P. Bidinosti,
Charles A. Davis,
Beatrice Franke,
Derek Fujimoto,
Michael T. W. Gericke,
Pietro Giampa,
Robert Golub,
Sean Hansen-Romu,
Kichiji Hatanaka,
Tomohiro Hayamizu,
Takashi Higuchi,
Go Ichikawa,
Sohei Imajo,
Blair Jamieson,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Wolfgang Klassen,
Emma Klemets,
Akira Konaka,
Elie Korkmaz,
Ekaterina Korobkina,
Florian Kuchler,
Maedeh Lavvaf
, et al. (23 additional authors not shown)
Abstract:
The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of $10^{-27}\,e\cdot\mathrm{cm}$, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are develo** a new high-intensity ultracold neutron (UCN) source using su…
▽ More
The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of $10^{-27}\,e\cdot\mathrm{cm}$, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are develo** a new high-intensity ultracold neutron (UCN) source using super-thermal UCN production in superfluid helium (He-II) and a nEDM spectrometer. The current development status of them is reported in this article.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
Study of Thin Iron Films for Polarization Analysis of Ultracold Neutrons
Authors:
Hiroaki Akatsuka,
Takashi Higuchi,
Sean Hansen-Romu,
Kichiji Hatanaka,
Tomohiro Hayamizu,
Masahiro Hino,
Go Ichikawa,
Sohei Imajo,
Blair Jamieson,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Ryohei Matsumiya,
Kenji Mishima
Abstract:
The TUCAN (TRIUMF Ultra-Cold Advanced Neutron) collaboration aims to search for the neutron electric dipole moment (nEDM) with unprecedented precision. One of the essential elements for the nEDM measurement is a polarization analyzer of ultracold neutrons (UCNs), whose main component is a magnetized thin iron film. Several thin iron films were deposited on aluminum and silicon ubstrates and were c…
▽ More
The TUCAN (TRIUMF Ultra-Cold Advanced Neutron) collaboration aims to search for the neutron electric dipole moment (nEDM) with unprecedented precision. One of the essential elements for the nEDM measurement is a polarization analyzer of ultracold neutrons (UCNs), whose main component is a magnetized thin iron film. Several thin iron films were deposited on aluminum and silicon ubstrates and were characterized by vibrating sample magnetometry and cold-neutron reflectometry. A magnetic field required to saturate the iron film is $\sim$12 kA/m for those on the aluminum substrates and 6.4 kA/m for the silicon substrates. The magnetic potential of the iron films on the Si substrate was estimated to be 2 T by the neutron reflectometry, which is sufficient performance for an UCN polarization analyzer of the nEDM measurement.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
Giant enhancement of THz wave emission underdouble pulse excitation of thin water flow
Authors:
Hsin-Hui Huang,
Takeshi Nagashima,
Tetsu Yonezawa,
Yasutaka Matsuo,
Soon Hock Ng,
Saulius Juodkazis,
Koji Hatanaka
Abstract:
Simultaneous measurements of THz wave and hard X-ray emission from thin and flat water flow when irradiated by double femtosecond laser pulses (800 nm, 35 fs, transform-limited, 0.5 kHz, delay times up to 15 ns) were carried out at the transmission and the reflection sides of the flow with THz time-domain spectroscopy and Geiger counters. THz wave emission spectra show their dynamic peak-shifts to…
▽ More
Simultaneous measurements of THz wave and hard X-ray emission from thin and flat water flow when irradiated by double femtosecond laser pulses (800 nm, 35 fs, transform-limited, 0.5 kHz, delay times up to 15 ns) were carried out at the transmission and the reflection sides of the flow with THz time-domain spectroscopy and Geiger counters. THz wave emission spectra show their dynamic peak-shifts toward the low frequency with the highest intensity enhancements more than 1.5 x 10^3 times in |E|^2 at the delay time of 4.7 ns between the two pulses, while X-ray intensity enhancements are limited to about 20 times at 0 ns under the same experimental conditions. The mechanisms for the spectral changes and the intensity enhancements in THz wave emission are discussed from the viewpoint of laser ablation on the water flow induced by the pre-pulse irradiation.
△ Less
Submitted 31 January, 2020;
originally announced January 2020.
-
A fast-switching magnet serving a spallation-driven ultracold neutron source
Authors:
S. Ahmed,
E. Altiere,
T. Andalib,
M. J. Barnes,
B. Bell,
C. P. Bidinosti,
Y. Bylinsky,
J. Chak,
M. Das,
C. A. Davis,
F. Fischer,
B. Franke,
M. T. W. Gericke,
P. Giampa,
M. Hahn,
S. Hansen-Romu,
K. Hatanaka,
T. Hayamizu,
B. Jamieson,
D. Jones,
K. Katsika,
S. Kawasaki,
T. Kikawa,
W. Klassen,
A. Konaka
, et al. (25 additional authors not shown)
Abstract:
A fast-switching, high-repetition-rate magnet and power supply have been developed for and operated at TRIUMF, to deliver a proton beam to the new ultracold neutron (UCN) facility. The facility possesses unique operational requirements: a time-averaged beam current of 40~$μ$A with the ability to switch the beam on or off for several minutes. These requirements are in conflict with the typical oper…
▽ More
A fast-switching, high-repetition-rate magnet and power supply have been developed for and operated at TRIUMF, to deliver a proton beam to the new ultracold neutron (UCN) facility. The facility possesses unique operational requirements: a time-averaged beam current of 40~$μ$A with the ability to switch the beam on or off for several minutes. These requirements are in conflict with the typical operation mode of the TRIUMF cyclotron which delivers nearly continuous beam to multiple users. To enable the creation of the UCN facility, a beam-sharing arrangement with another facility was made. The beam sharing is accomplished by the fast-switching (kicker) magnet which is ramped in 50~$μ$s to a current of 193~A, held there for approximately 1~ms, then ramped down in the same short period of time. This achieves a 12~mrad deflection which is sufficient to switch the proton beam between the two facilities. The kicker magnet relies on a high-current, low-inductance coil connected to a fast-switching power supply that is based on insulated-gate bipolar transistors (IGBTs). The design and performance of the kicker magnet system and initial beam delivery results are reported.
△ Less
Submitted 11 August, 2019; v1 submitted 21 May, 2019;
originally announced May 2019.
-
Correlated emission of X-ray and sound from water film irradiated by femtosecond laser pulses
Authors:
Hsin-hui Huang,
Saulius Juodkazis,
Koji Hatanaka
Abstract:
Simultaneous measurements of hard X-ray by a Geiger counter and audible sound (10 Hz-20kHz) by a microphone from a thin water film in air were carried out under intense single and double pulse irradiations of femtosecond laser (35 fs, 800 nm, 1 kHz). Emission profiles of X-ray and sound under the single pulse irradiation by changing the water film position along the laser incident direction (Z-axi…
▽ More
Simultaneous measurements of hard X-ray by a Geiger counter and audible sound (10 Hz-20kHz) by a microphone from a thin water film in air were carried out under intense single and double pulse irradiations of femtosecond laser (35 fs, 800 nm, 1 kHz). Emission profiles of X-ray and sound under the single pulse irradiation by changing the water film position along the laser incident direction (Z-axis) show the same peak positions with a broader emission in sound (403μm at FWHM) than in X-ray (37μm). Under the double pulse irradiation condition with the time delay at 0 ps and 4.6 ns, it was clearly observed that the acoustic signal intensity is enhanced in associated with X-ray intensity enhancements. The enhancements can be assigned to laser ablation dynamics such as pre-plasma formation and transient surface roughness formation induced by the pre-pulse irradiation. For the acoustic signal under the double-pulse irradiation with the time delay, there was a weak dependence observed on the pre-pulse irradiation position at the laser focus. It is consistent with a long breakdown filament formation which makes the microphone-detection less position-sensitive.
△ Less
Submitted 12 February, 2019;
originally announced February 2019.
-
A beamline for fundamental neutron physics at TRIUMF
Authors:
S. Ahmed,
T. Andalib,
M. J. Barnes,
C. B. Bidinosti,
Y. Bylinsky,
J. Chak,
M. Das,
C. A. Davis,
B. Franke,
M. T. W. Gericke,
P. Giampa,
M. Hahn,
S. Hansen-Romu,
K. Hatanaka,
B. Jamieson,
D. Jones,
K. Katsika,
S. Kawasaki,
W. Klassen,
A. Konaka,
E. Korkmaz,
F. Kuchler,
L. Kurchaninov,
M. Lang,
L. Lee
, et al. (22 additional authors not shown)
Abstract:
This article describes the new primary proton beamline 1U at TRIUMF. The purpose of this beamline is to produce ultracold neutrons (UCN) for fundamental-physics experiments. It delivers up to 40 microA of 480 MeV protons from the TRIUMF cyclotron to a tungsten spallation target and uses a fast kicker to share the beam between the Center for Molecular and Materials Science and UCN. The beamline has…
▽ More
This article describes the new primary proton beamline 1U at TRIUMF. The purpose of this beamline is to produce ultracold neutrons (UCN) for fundamental-physics experiments. It delivers up to 40 microA of 480 MeV protons from the TRIUMF cyclotron to a tungsten spallation target and uses a fast kicker to share the beam between the Center for Molecular and Materials Science and UCN. The beamline has been successfully commissioned and operated with a beam current up to 10 microA, facilitating first large-scale UCN production in Canada.
△ Less
Submitted 26 December, 2018; v1 submitted 1 October, 2018;
originally announced October 2018.
-
First ultracold neutrons produced at TRIUMF
Authors:
S. Ahmed,
E. Altiere,
T. Andalib,
B. Bell,
C. P. Bidinosti,
E. Cudmore,
M. Das,
C. A. Davis,
B. Franke,
M. Gericke,
P. Giampa,
P. Gnyp,
S. Hansen-Romu,
K. Hatanaka,
T. Hayamizu,
B. Jamieson,
D. Jones,
S. Kawasaki,
T. Kikawa,
M. Kitaguchi,
W. Klassen,
A. Konaka,
E. Korkmaz,
F. Kuchler,
M. Lang
, et al. (28 additional authors not shown)
Abstract:
We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this so…
▽ More
We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this source. The corresponding ultracold-neutron density in the whole production and guide volume is 5.3$\,$cm$^{-3}$. The storage lifetime of ultracold neutrons in the source was initially 37$\,$s and dropped to 24$\,$s during the eighteen days of operation. During continuous irradiation of the spallation target, we were able to detect a sustained ultracold-neutron rate of up to 1500$\,$s$^{-1}$. Simulations of UCN production, UCN transport, temperature-dependent UCN yield, and temperature-dependent storage lifetime show excellent agreement with the experimental data and confirm that the ultracold-neutron-upscattering rate in superfluid helium is proportional to $T^7$.
△ Less
Submitted 16 December, 2018; v1 submitted 10 September, 2018;
originally announced September 2018.
-
MuSIC: delivering the world's most intense muon beam
Authors:
S. Cook,
R. D'Arcy,
A. Edmonds,
M. Fukuda,
K. Hatanaka,
Y. Hino,
Y. Kuno,
M. Lancaster,
Y. Mori,
T. Ogitsu,
H. Sakamoto,
A. Sato,
N. H. Tran,
N. M. Truong,
M. Wing,
A. Yamamoto,
M. Yoshida
Abstract:
A new muon beamline, muon science innovative channel (MuSIC), was set up at the Research Centre for Nuclear Physics (RCNP), Osaka University, in Osaka, Japan, using the 392 MeV proton beam im**ing on a target. The production of an intense muon beam relies on the efficient capture of pions, which subsequently decay to muons, using a novel superconducting solenoid magnet system. After the pion-cap…
▽ More
A new muon beamline, muon science innovative channel (MuSIC), was set up at the Research Centre for Nuclear Physics (RCNP), Osaka University, in Osaka, Japan, using the 392 MeV proton beam im**ing on a target. The production of an intense muon beam relies on the efficient capture of pions, which subsequently decay to muons, using a novel superconducting solenoid magnet system. After the pion-capture solenoid the first $36^\circ$ of the curved muon transport line was commissioned and the muon flux was measured. In order to detect muons, a target of either copper or magnesium was placed to stop muons at the end of the muon beamline. Two stations of plastic scintillators located upstream and downstream from the muon target were used to reconstruct the decay spectrum of muons. In a complementary method to detect negatively-charged muons, the X-ray spectrum yielded by muonic atoms in the target were measured in a germanium detector. Measurements, at a proton beam current of 6 pA, yielded $(10.4 \pm 2.7) \times 10^5$ muons per Watt of proton beam power ($μ^+$ and $μ^-$), far in excess of other facilities. At full beam power (400 W), this implies a rate of muons of $(4.2 \pm 1.1) \times 10^8$ muons s$^{-1}$, amongst the highest in the world. The number of $μ^-$ measured was about a factor of 10 lower, again by far the most efficient muon beam produced. The set up is a prototype for future experiments requiring a high-intensity muon beam, such as a muon collider or neutrino factory, or the search for rare muon decays which would be a signature for phenomena beyond the Standard Model of particle physics. Such a muon beam can also be used in other branches of physics, nuclear and condensed matter, as well as other areas of scientific research.
△ Less
Submitted 25 October, 2016;
originally announced October 2016.
-
Laser frequency locking with 46 GHz offset using an electro-optic modulator for magneto-optical trap** of francium atoms
Authors:
K. Harada,
T. Aoki,
S. Ezure,
K. Kato,
T. Hayamizu,
H. Kawamura,
T. Inoue,
H. Arikawa,
T. Ishikawa,
T. Aoki,
A. Uchiyama,
K. Sakamoto,
S. Ito,
M. Itoh,
S. Ando,
A. Hatakeyama,
K. Hatanaka,
K. Imai,
T. Murakami,
H. S. Nataraj,
Y. Shimizu,
T. Sato,
T. Wakasa,
H. P. Yoshida,
Y. Sakemi
Abstract:
We demonstrated a frequency offset locking between two laser sources using a waveguide-type electro-optic modulator (EOM) with 10th-order sidebands for magneto-optical trap** of Fr atoms. The frequency locking error signal was successfully obtained by performing delayed self-homodyne detection of the beat signal between the repum** frequency and the 10th-order sideband component of the trappin…
▽ More
We demonstrated a frequency offset locking between two laser sources using a waveguide-type electro-optic modulator (EOM) with 10th-order sidebands for magneto-optical trap** of Fr atoms. The frequency locking error signal was successfully obtained by performing delayed self-homodyne detection of the beat signal between the repum** frequency and the 10th-order sideband component of the trap** light. Swee** the trap**-light and repum**-light frequencies with kee** its frequency difference of 46 GHz was confirmed over 1 GHz by monitoring the Doppler absorption profile of I2. This technique enables us to search for a resonance frequency of magneto-optical trap** of Fr.
△ Less
Submitted 1 April, 2016;
originally announced April 2016.
-
Development of the Photomultiplier-Tube Readout System for the CTA Large Size Telescope
Authors:
H. Kubo,
R. Paoletti,
Y. Awane,
A. Bamba,
M. Barcelo,
J. A. Barrio,
O. Blanch,
J. Boix,
C. Delgado,
D. Fink,
D. Gascon,
S. Gunji,
R. Hagiwara,
Y. Hanabata,
K. Hatanaka,
M. Hayashida,
M. Ikeno,
S. Kabuki,
H. Katagiri,
J. Kataoka,
Y. Konno,
S. Koyama,
T. Kishimoto,
J. Kushida,
G. Martinez
, et al. (29 additional authors not shown)
Abstract:
We have developed a prototype of the photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two thousand PMTs along with their readout systems are arranged on the focal plane of each telescope, with one readout system per 7-PMT cluster. The Cherenkov light pulses generated by the air showers are detected by the PMTs and amplified in a compact,…
▽ More
We have developed a prototype of the photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two thousand PMTs along with their readout systems are arranged on the focal plane of each telescope, with one readout system per 7-PMT cluster. The Cherenkov light pulses generated by the air showers are detected by the PMTs and amplified in a compact, low noise and wide dynamic range gain block. The output of this block is then digitized at a sampling rate of the order of GHz using the Domino Ring Sampler DRS4, an analog memory ASIC developed at Paul Scherrer Institute. The sampler has 1,024 capacitors per channel and four channels are cascaded for increased depth. After a trigger is generated in the system, the charges stored in the capacitors are digitized by an external slow sampling ADC and then transmitted via Gigabit Ethernet. An onboard FPGA controls the DRS4, trigger threshold, and Ethernet transfer. In addition, the control and monitoring of the Cockcroft-Walton circuit that provides high voltage for the 7-PMT cluster are performed by the same FPGA. A prototype named Dragon has been developed that has successfully sampled PMT signals at a rate of 2 GHz, and generated single photoelectron spectra.
△ Less
Submitted 12 July, 2013;
originally announced July 2013.