-
New Concept for Electron Beam-Dump Experiment Utilizing Directional WIMP Detector
Authors:
D. P. Snowden-Ifft,
J. L. Harton,
N. Ma,
F. G. Schuckman II
Abstract:
Light dark matter in the context of dark sector theories is an attractive candidate for the dark matter thought to make up the bulk of the mass of our universe. We explore here the possibility of using a low-pressure, negative-ion, time projection chamber detector to search for light dark matter behind the beam dump of an electron accelerator. The sensitivity of a 10 m long detector is several ord…
▽ More
Light dark matter in the context of dark sector theories is an attractive candidate for the dark matter thought to make up the bulk of the mass of our universe. We explore here the possibility of using a low-pressure, negative-ion, time projection chamber detector to search for light dark matter behind the beam dump of an electron accelerator. The sensitivity of a 10 m long detector is several orders of magnitude better than existing limits. This sensitivity includes regions of parameter space where light dark matter is predicted to have a required relic density consistent with measured dark matter density. Backgrounds at shallow depth will need to be considered carefully. However, several signatures exist, including a powerful directional signature, which will allow a detection even in the presence of backgrounds.
△ Less
Submitted 6 January, 2019; v1 submitted 18 September, 2018;
originally announced September 2018.
-
Spectral Calibration of the Fluorescence Telescopes of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila,
A. M. Badescu,
A. Balaceanu,
F. Barbato,
R. J. Barreira Luz
, et al. (381 additional authors not shown)
Abstract:
We present a novel method to measure precisely the relative spectral response of the fluorescence telescopes of the Pierre Auger Observatory. We used a portable light source based on a xenon flasher and a monochromator to measure the relative spectral efficiencies of eight telescopes in steps of 5 nm from 280 nm to 440 nm. Each point in a scan had approximately 2 nm FWHM out of the monochromator.…
▽ More
We present a novel method to measure precisely the relative spectral response of the fluorescence telescopes of the Pierre Auger Observatory. We used a portable light source based on a xenon flasher and a monochromator to measure the relative spectral efficiencies of eight telescopes in steps of 5 nm from 280 nm to 440 nm. Each point in a scan had approximately 2 nm FWHM out of the monochromator. Different sets of telescopes in the observatory have different optical components, and the eight telescopes measured represent two each of the four combinations of components represented in the observatory. We made an end-to-end measurement of the response from different combinations of optical components, and the monochromator setup allowed for more precise and complete measurements than our previous multi-wavelength calibrations. We find an overall uncertainty in the calibration of the spectral response of most of the telescopes of 1.5% for all wavelengths; the six oldest telescopes have larger overall uncertainties of about 2.2%. We also report changes in physics measureables due to the change in calibration, which are generally small.
△ Less
Submitted 2 October, 2017; v1 submitted 5 September, 2017;
originally announced September 2017.
-
Measurement of directional range components of nuclear recoil tracks in a fiducialised dark matter detector
Authors:
J. B. R. Battat,
E. J. Daw,
A. C. Ezeribe,
J. -L. Gauvreau,
J. L. Harton,
R. Lafler,
E. R. Lee,
D. Loomba,
W. Lynch,
E. H. Miller,
F. Mouton,
S. Paling,
N. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. G. Schuckman II,
D. P. Snowden-Ifft,
N. J. C. Spooner
Abstract:
We present results from the first measurement of axial range components of fiducialized neutron induced nuclear recoil tracks using the DRIFT directional dark matter detector. Nuclear recoil events are fiducialized in the DRIFT experiment using temporal charge carrier separations between different species of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this measurement, neutron-i…
▽ More
We present results from the first measurement of axial range components of fiducialized neutron induced nuclear recoil tracks using the DRIFT directional dark matter detector. Nuclear recoil events are fiducialized in the DRIFT experiment using temporal charge carrier separations between different species of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this measurement, neutron-induced nuclear recoil tracks were generated by exposing the detector to $^{252}$Cf source from different directions. Using these events, the sensitivity of the detector to the expected axial directional signatures were investigated as the neutron source was moved from one detector axis to another. Results obtained from these measurements show clear sensitivity of the DRIFT detector to the axial directional signatures in this fiducialization gas mode.
△ Less
Submitted 28 July, 2017;
originally announced July 2017.
-
Muon Counting using Silicon Photomultipliers in the AMIGA detector of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila,
A. M. Badescu
, et al. (400 additional authors not shown)
Abstract:
AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is com…
▽ More
AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m$^2$ detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), is proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98 % efficiency for the highest tested overvoltage, combined with a low probability of accidental counting ($\sim$2 %), show a promising performance for this new system.
△ Less
Submitted 4 October, 2017; v1 submitted 17 March, 2017;
originally announced March 2017.
-
Low Threshold Results and Limits from the DRIFT Directional Dark Matter Detector
Authors:
J. B. R. Battat,
A. C. Ezeribe,
J. -L. Gauvreau,
J. L. Harton,
R. Lafler,
E. Law,
E. R. Lee,
D. Loomba,
A. Lumnah,
E. H. Miller,
A. Monte,
F. Mouton,
S. M. Paling,
N. S. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. G. Schuckman II,
D. P. Snowden-Ifft,
N. J. C. Spooner,
N. Waldram
Abstract:
We present results from a 54.7 live-day shielded run of the DRIFT-IId detector, the world's most sensitive, directional, dark matter detector. Several improvements were made relative to our previous work including a lower threshold for detection, a more robust analysis and a tenfold improvement in our gamma rejection factor. After analysis, no events remain in our fiducial region leading to an exc…
▽ More
We present results from a 54.7 live-day shielded run of the DRIFT-IId detector, the world's most sensitive, directional, dark matter detector. Several improvements were made relative to our previous work including a lower threshold for detection, a more robust analysis and a tenfold improvement in our gamma rejection factor. After analysis, no events remain in our fiducial region leading to an exclusion curve for spin-dependent WIMP-proton interactions which reaches 0.28 pb at 100 GeV/c^2 a fourfold improvement on our previous work. We also present results from a 45.4 live-day unshielded run of the DRIFT-IId detector during which 14 nuclear recoil-like events were observed. We demonstrate that the observed nuclear recoil rate of 0.31+/-0.08 events per day is consistent with detection of ambient, fast neutrons emanating from the walls of the Boulby Underground Science Facility.
△ Less
Submitted 27 March, 2017; v1 submitted 31 December, 2016;
originally announced January 2017.
-
First measurement of nuclear recoil head-tail sense in a fiducialised WIMP dark matter detector
Authors:
J. B. R. Battat,
E. Daw,
A. C. Ezeribe,
J. -L. Gauvreau,
J. L. Harton,
R. Lafler,
E. R. Lee,
D. Loomba,
A. Lumnah,
E. H. Miller,
F. Mouton,
A. StJ. Murphy,
S. M. Paling,
N. S. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. G. Schuckman II,
D. P. Snowden-Ifft,
N. J. C. Spooner
Abstract:
Recent computational results suggest that directional dark matter detectors have potential to probe for WIMP dark matter particles below the neutrino floor. The DRIFT-IId detector used in this work is a leading directional WIMP search time projection chamber detector. We report the first measurements of the detection of the directional nuclear recoils in a fully fiducialised low-pressure time proj…
▽ More
Recent computational results suggest that directional dark matter detectors have potential to probe for WIMP dark matter particles below the neutrino floor. The DRIFT-IId detector used in this work is a leading directional WIMP search time projection chamber detector. We report the first measurements of the detection of the directional nuclear recoils in a fully fiducialised low-pressure time projection chamber. In this new operational mode, the distance between each event vertex and the readout plane is determined by the measurement of minority carriers produced by adding a small amount of oxygen to the nominal CS$_{2}$ + CF$_{4}$ target gas mixture. The CS$_2$ + CF$_4$ + O$_2$ mixture has been shown to enable background-free operation at current sensitivities. Sulfur, fluorine, and carbon recoils were generated using neutrons emitted from a $^{252}$Cf source positioned at different locations around the detector. Measurement of the relative energy loss along the recoil tracks allowed the track vector sense, or the so-called head-tail asymmetry parameter, to be deduced. Results show that the previously reported observation of head-tail sensitivity in pure CS$_{2}$ is well retained after the addition of oxygen to the gas mixture.
△ Less
Submitted 24 November, 2016; v1 submitted 16 June, 2016;
originally announced June 2016.
-
Prototype muon detectors for the AMIGA component of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
R. Alves Batista,
M. Ambrosio,
A. Aminaei,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin
, et al. (429 additional authors not shown)
Abstract:
Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary…
▽ More
Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary Cell, are to identify and resolve all engineering issues as well as to understand the muon-number counting uncertainties related to the design of the detector. The mechanical design, fabrication and deployment processes of the muon counters of the Unitary Cell are described in this document. These muon counters modules comprise sealed PVC casings containing plastic scintillation bars, wavelength-shifter optical fibers, 64 pixel photomultiplier tubes, and acquisition electronics. The modules are buried approximately 2.25 m below ground level in order to minimize contamination from electromagnetic shower particles. The mechanical setup, which allows access to the electronics for maintenance, is also described in addition to tests of the modules' response and integrity. The completed Unitary Cell has measured a number of air showers of which a first analysis of a sample event is included here.
△ Less
Submitted 12 May, 2016; v1 submitted 5 May, 2016;
originally announced May 2016.
-
Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
R. Alves Batista,
M. Ambrosio,
A. Aminaei,
G. A. Anastasi,
L. Anchordoqui,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila
, et al. (426 additional authors not shown)
Abstract:
To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected…
▽ More
To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique to correct for the GPS drifts, and an independent method is used for cross-checks that indeed we reach nanosecond-scale timing accuracy by this correction. First, we operate a "beacon transmitter" which emits defined sine waves detected by AERA antennas recorded within the physics data. The relative phasing of these sine waves can be used to correct for GPS clock drifts. In addition to this, we observe radio pulses emitted by commercial airplanes, the position of which we determine in real time from Automatic Dependent Surveillance Broadcasts intercepted with a software-defined radio. From the known source location and the measured arrival times of the pulses we determine relative timing offsets between radio detector stations. We demonstrate with a combined analysis that the two methods give a consistent timing calibration with an accuracy of 2 ns or better. Consequently, the beacon method alone can be used in the future to continuously determine and correct for GPS clock drifts in each individual event measured by AERA.
△ Less
Submitted 15 February, 2016; v1 submitted 7 December, 2015;
originally announced December 2015.
-
First background-free limit from a directional dark matter experiment: results from a fully fiducialised DRIFT detector
Authors:
J. B. R. Battat,
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. -L. Gauvreau,
M. Gold,
J. L. Harton,
J. M. Landers,
E. Law,
E. R. Lee,
D. Loomba,
A. Lumnah,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
F. Mouton,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. Schuckman,
D. P. Snowden-Ifft
, et al. (6 additional authors not shown)
Abstract:
The addition of O2 to gas mixtures in time projection chambers containing CS2 has recently been shown to produce multiple negative ions that travel at slightly different velocities. This allows a measurement of the absolute position of ionising events in the z (drift) direction. In this work, we apply the z-fiducialisation technique to a directional dark matter search. In particular, we present re…
▽ More
The addition of O2 to gas mixtures in time projection chambers containing CS2 has recently been shown to produce multiple negative ions that travel at slightly different velocities. This allows a measurement of the absolute position of ionising events in the z (drift) direction. In this work, we apply the z-fiducialisation technique to a directional dark matter search. In particular, we present results from a 46.3 live-day source-free exposure of the DRIFT-IId detector run in this completely new mode. With full-volume fiducialisation, we have achieved the first background-free operation of a directional detector. The resulting exclusion curve for spin-dependent WIMP-proton interactions reaches 1.1 pb at 100 GeV/c2, a factor of 2 better than our previous work. We describe the automated analysis used here, and argue that detector upgrades, implemented after the acquisition of these data, will bring an additional factor of >3 improvement in the near future.
△ Less
Submitted 23 July, 2015; v1 submitted 28 October, 2014;
originally announced October 2014.
-
Radon in the DRIFT-II directional dark matter TPC: emanation, detection and mitigation
Authors:
J. B. R. Battat,
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. R. Fox,
J. -L. Gauvreau,
M. Gold,
L. J. Harmon,
J. L. Harton,
J. M. Landers,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Pipe,
M. Robinson,
S. W. Sadler,
A. Scarff,
D. P. Snowden-Ifft,
N. J. C. Spooner
, et al. (4 additional authors not shown)
Abstract:
Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils of radon daughter isotopes…
▽ More
Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils of radon daughter isotopes, which can mimic the signal expected from WIMP interactions. Presented here are results of measurements of radon emanation from detector materials in the 1 metre cubed DRIFT-II directional dark matter gas time projection chamber experiment. Construction and operation of a radon emanation facility for this work is described, along with an analysis to continuously monitor DRIFT data for the presence of internal 222Rn and 218Po. Applying this analysis to historical DRIFT data, we show how systematic substitution of detector materials for alternatives, selected by this device for low radon emanation, has resulted in a factor of ~10 reduction in internal radon rates. Levels are found to be consistent with the sum from separate radon emanation measurements of the internal materials and also with direct measurement using an attached alpha spectrometer. The current DRIFT detector, DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 μBq/l with current analysis efficiency, potentially opening up DRIFT technology as a new tool for sensitive radon assay of materials.
△ Less
Submitted 25 August, 2014; v1 submitted 15 July, 2014;
originally announced July 2014.
-
Absolute Calibration of a Large-diameter Light Source
Authors:
J. T. Brack,
R. Cope,
A. Dorofeev,
B. Gookin,
J. L. Harton,
Y. Petrov,
A. C. Rovero
Abstract:
A method of absolute calibration for large aperture optical systems is presented, using the example of the Pierre Auger Observatory fluorescence detectors. A 2.5 m diameter light source illuminated by an ultra--violet light emitting diode is calibrated with an overall uncertainty of 2.1 % at a wavelength of 365 nm.
A method of absolute calibration for large aperture optical systems is presented, using the example of the Pierre Auger Observatory fluorescence detectors. A 2.5 m diameter light source illuminated by an ultra--violet light emitting diode is calibrated with an overall uncertainty of 2.1 % at a wavelength of 365 nm.
△ Less
Submitted 6 May, 2013;
originally announced May 2013.
-
The DRIFT Dark Matter Experiments
Authors:
E. Daw,
A. Dorofeev,
J. R. Fox,
J. -L. Gauvreau,
C. Ghag,
L. J. Harmon,
J. L. Harton,
M. Gold,
E. R. Lee,
D. Loomba,
E. H. Miller,
A. St. J. Murphy,
S. M. Paling,
J. M. Landers,
N. Phan,
M. Pipe,
K. Pushkin,
M. Robinson,
S. W. Sadler,
D. P. Snowden-Ifft,
N. J. C. Spooner,
D. Walker,
D. Warner
Abstract:
The current status of the DRIFT (Directional Recoil Identification From Tracks) experiment at Boulby Mine is presented, including the latest limits on the WIMP spin-dependent cross-section from 1.5 kg days of running with a mixture of CS2 and CF4. Planned upgrades to DRIFT IId are detailed, along with ongoing work towards DRIFT III, which aims to be the world's first 10 m3-scale directional Dark M…
▽ More
The current status of the DRIFT (Directional Recoil Identification From Tracks) experiment at Boulby Mine is presented, including the latest limits on the WIMP spin-dependent cross-section from 1.5 kg days of running with a mixture of CS2 and CF4. Planned upgrades to DRIFT IId are detailed, along with ongoing work towards DRIFT III, which aims to be the world's first 10 m3-scale directional Dark Matter detector.
△ Less
Submitted 2 October, 2011;
originally announced October 2011.
-
The Pierre Auger Observatory V: Enhancements
Authors:
The Pierre Auger Collaboration,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. F. M. Albuquerque,
D. Allard,
I. Allekotte,
J. Allen,
P. Allison,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
A. Aminaei,
L. Anchordoqui,
S. Andringa,
T. Antičić,
A. Anzalone,
C. Aramo,
E. Arganda,
F. Arqueros,
H. Asorey,
P. Assis,
J. Aublin,
M. Ave,
M. Avenier
, et al. (471 additional authors not shown)
Abstract:
Ongoing and planned enhancements of the Pierre Auger Observatory
Ongoing and planned enhancements of the Pierre Auger Observatory
△ Less
Submitted 24 July, 2011;
originally announced July 2011.
-
The Pierre Auger Observatory IV: Operation and Monitoring
Authors:
The Pierre Auger Collaboration,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. F. M. Albuquerque,
D. Allard,
I. Allekotte,
J. Allen,
P. Allison,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
A. Aminaei,
L. Anchordoqui,
S. Andringa,
T. Antičić,
A. Anzalone,
C. Aramo,
E. Arganda,
F. Arqueros,
H. Asorey,
P. Assis,
J. Aublin,
M. Ave,
M. Avenier
, et al. (471 additional authors not shown)
Abstract:
Technical reports on operations and monitoring of the Pierre Auger Observatory
Technical reports on operations and monitoring of the Pierre Auger Observatory
△ Less
Submitted 24 July, 2011;
originally announced July 2011.