-
Comprehensive and Clinically Accurate Head and Neck Organs at Risk Delineation via Stratified Deep Learning: A Large-scale Multi-Institutional Study
Authors:
Dazhou Guo,
Jia Ge,
Xianghua Ye,
Senxiang Yan,
Yi Xin,
Yuchen Song,
Bing-shen Huang,
Tsung-Min Hung,
Zhuotun Zhu,
Ling Peng,
Yan** Ren,
Rui Liu,
Gong Zhang,
Mengyuan Mao,
Xiaohua Chen,
Zhongjie Lu,
Wenxiang Li,
Yuzhen Chen,
Lingyun Huang,
**g Xiao,
Adam P. Harrison,
Le Lu,
Chien-Yu Lin,
Dakai **,
Tsung-Ying Ho
Abstract:
Accurate organ at risk (OAR) segmentation is critical to reduce the radiotherapy post-treatment complications. Consensus guidelines recommend a set of more than 40 OARs in the head and neck (H&N) region, however, due to the predictable prohibitive labor-cost of this task, most institutions choose a substantially simplified protocol by delineating a smaller subset of OARs and neglecting the dose di…
▽ More
Accurate organ at risk (OAR) segmentation is critical to reduce the radiotherapy post-treatment complications. Consensus guidelines recommend a set of more than 40 OARs in the head and neck (H&N) region, however, due to the predictable prohibitive labor-cost of this task, most institutions choose a substantially simplified protocol by delineating a smaller subset of OARs and neglecting the dose distributions associated with other OARs. In this work we propose a novel, automated and highly effective stratified OAR segmentation (SOARS) system using deep learning to precisely delineate a comprehensive set of 42 H&N OARs. SOARS stratifies 42 OARs into anchor, mid-level, and small & hard subcategories, with specifically derived neural network architectures for each category by neural architecture search (NAS) principles. We built SOARS models using 176 training patients in an internal institution and independently evaluated on 1327 external patients across six different institutions. It consistently outperformed other state-of-the-art methods by at least 3-5% in Dice score for each institutional evaluation (up to 36% relative error reduction in other metrics). More importantly, extensive multi-user studies evidently demonstrated that 98% of the SOARS predictions need only very minor or no revisions for direct clinical acceptance (saving 90% radiation oncologists workload), and their segmentation and dosimetric accuracy are within or smaller than the inter-user variation. These findings confirmed the strong clinical applicability of SOARS for the OAR delineation process in H&N cancer radiotherapy workflows, with improved efficiency, comprehensiveness, and quality.
△ Less
Submitted 1 November, 2021;
originally announced November 2021.
-
Accurate and Generalizable Quantitative Scoring of Liver Steatosis from Ultrasound Images via Scalable Deep Learning
Authors:
Bowen Li,
Dar-In Tai,
Ke Yan,
Yi-Cheng Chen,
Shiu-Feng Huang,
Tse-Hwa Hsu,
Wan-Ting Yu,
**g Xiao,
Le Lu,
Adam P. Harrison
Abstract:
Background & Aims: Hepatic steatosis is a major cause of chronic liver disease. 2D ultrasound is the most widely used non-invasive tool for screening and monitoring, but associated diagnoses are highly subjective. We developed a scalable deep learning (DL) algorithm for quantitative scoring of liver steatosis from 2D ultrasound images.
Approach & Results: Using retrospectively collected multi-vi…
▽ More
Background & Aims: Hepatic steatosis is a major cause of chronic liver disease. 2D ultrasound is the most widely used non-invasive tool for screening and monitoring, but associated diagnoses are highly subjective. We developed a scalable deep learning (DL) algorithm for quantitative scoring of liver steatosis from 2D ultrasound images.
Approach & Results: Using retrospectively collected multi-view ultrasound data from 3,310 patients, 19,513 studies, and 228,075 images, we trained a DL algorithm to diagnose steatosis stages (healthy, mild, moderate, or severe) from ultrasound diagnoses. Performance was validated on two multi-scanner unblinded and blinded (initially to DL developer) histology-proven cohorts (147 and 112 patients) with histopathology fatty cell percentage diagnoses, and a subset with FibroScan diagnoses. We also quantified reliability across scanners and viewpoints. Results were evaluated using Bland-Altman and receiver operating characteristic (ROC) analysis. The DL algorithm demonstrates repeatable measurements with a moderate number of images (3 for each viewpoint) and high agreement across 3 premium ultrasound scanners. High diagnostic performance was observed across all viewpoints: area under the curves of the ROC to classify >=mild, >=moderate, =severe steatosis grades were 0.85, 0.90, and 0.93, respectively. The DL algorithm outperformed or performed at least comparably to FibroScan with statistically significant improvements for all levels on the unblinded histology-proven cohort, and for =severe steatosis on the blinded histology-proven cohort.
Conclusions: The DL algorithm provides a reliable quantitative steatosis assessment across view and scanners on two multi-scanner cohorts. Diagnostic performance was high with comparable or better performance than FibroScan.
△ Less
Submitted 11 October, 2021;
originally announced October 2021.
-
A method for generating coherent spatially explicit maps of seasonal palaeoclimates from site-based reconstructions
Authors:
S. F. Cleator,
S. P. Harrison,
N. K. Nichols,
I. C. Prentice,
I. Roulstone
Abstract:
We describe a method for reconstructing spatially explicit maps of seasonal palaeoclimate variables from site-based reconstructions. Using a 3D-Variational technique, the method finds the best statistically unbiased, and spatially continuous, estimate of the palaeoclimate anomalies through combining the site-based reconstructions and a prior estimate of the palaeoclimate state. By assuming a set o…
▽ More
We describe a method for reconstructing spatially explicit maps of seasonal palaeoclimate variables from site-based reconstructions. Using a 3D-Variational technique, the method finds the best statistically unbiased, and spatially continuous, estimate of the palaeoclimate anomalies through combining the site-based reconstructions and a prior estimate of the palaeoclimate state. By assuming a set of correlations in the error of the prior, the resulting climate is smoothed both from month to month and from grid cell to grid cell. The amount of smoothing can be controlled through the choice of two length-scale values. The method is applied to a set of reconstructions of the climate of the Last Glacial Maximum (ca. 21,000 years ago, yr BP) for southern Europe derived from pollen data with a prior derived from results from the third phase of the Palaeoclimate Intercomparison Project (PMIP3). We demonstrate how to choose suitable values for the smoothing length scales from the datasets used in the reconstruction.
△ Less
Submitted 9 September, 2019; v1 submitted 13 February, 2019;
originally announced February 2019.
-
Laura++ : a Dalitz plot fitter
Authors:
John Back,
Tim Gershon,
Paul Harrison,
Thomas Latham,
Daniel O'Hanlon,
Wenbin Qian,
Pablo del Amo Sanchez,
Daniel Craik,
Jelena Ilic,
Juan Martin Otalora Goicochea,
Eugenia Puccio,
Rafael Silva Coutinho,
Mark Whitehead
Abstract:
The Dalitz plot analysis technique has become an increasingly important method in heavy flavour physics. The Laura++ fitter has been developed as a flexible tool that can be used for Dalitz plot analyses in different experimental environments. Explicitly designed for three-body decays of heavy-flavoured mesons to spinless final state particles, it is optimised in order to describe all possible res…
▽ More
The Dalitz plot analysis technique has become an increasingly important method in heavy flavour physics. The Laura++ fitter has been developed as a flexible tool that can be used for Dalitz plot analyses in different experimental environments. Explicitly designed for three-body decays of heavy-flavoured mesons to spinless final state particles, it is optimised in order to describe all possible resonant or nonresonant contributions, and to accommodate possible CP violation effects.
△ Less
Submitted 11 December, 2018; v1 submitted 27 November, 2017;
originally announced November 2017.
-
nuSTORM - Neutrinos from STORed Muons: Proposal to the Fermilab PAC
Authors:
D. Adey,
S. K. Agarwalla,
C. M. Ankenbrandt,
R. Asfandiyarov,
J. J. Back,
G. Barker,
E. Baussan,
R. Bayes,
S. Bhadra,
V. Blackmore,
A. Blondel,
S. A. Bogacz,
C. Booth,
S. B. Boyd,
A. Bravar,
S. J. Brice,
A. D. Bross,
F. Cadoux,
H. Cease,
A. Cervera,
J. Cobb,
D. Colling,
P. Coloma,
L. Coney,
A. Dobbs
, et al. (88 additional authors not shown)
Abstract:
The nuSTORM facility has been designed to deliver beams of electron neutrinos and muon neutrinos (and their anti-particles) from the decay of a stored muon beam with a central momentum of 3.8 GeV/c and a momentum acceptance of 10%. The facility is unique in that it will: 1. Allow searches for sterile neutrinos of exquisite sensitivity to be carried out; 2. Serve future long- and short-baseline neu…
▽ More
The nuSTORM facility has been designed to deliver beams of electron neutrinos and muon neutrinos (and their anti-particles) from the decay of a stored muon beam with a central momentum of 3.8 GeV/c and a momentum acceptance of 10%. The facility is unique in that it will: 1. Allow searches for sterile neutrinos of exquisite sensitivity to be carried out; 2. Serve future long- and short-baseline neutrino-oscillation programs by providing definitive measurements of electron neutrino and muon neutrino scattering cross sections off nuclei with percent-level precision; and 3. Constitutes the crucial first step in the development of muon accelerators as a powerful new technique for particle physics. The document describes the facility in detail and demonstrates its physics capabilities. This document was submitted to the Fermilab Physics Advisory Committee in consideration for Stage I approval.
△ Less
Submitted 31 July, 2013;
originally announced August 2013.
-
The Electromagnetic Calorimeter for the T2K Near Detector ND280
Authors:
D. Allan,
C. Andreopoulos,
C. Angelsen,
G. J. Barker,
G. Barr,
S. Bentham,
I. Bertram,
S. Boyd,
K. Briggs,
R. G. Calland,
J. Carroll,
S. L. Cartwright,
A. Carver,
C. Chavez,
G. Christodoulou,
J. Coleman,
P. Cooke,
G. Davies,
C. Densham,
F. Di Lodovico,
J. Dobson,
T. Duboyski,
T. Durkin,
D. L. Evans,
A. Finch
, et al. (84 additional authors not shown)
Abstract:
The T2K experiment studies oscillations of an off-axis muon neutrino beam between the J-PARC accelerator complex and the Super-Kamiokande detector. Special emphasis is placed on measuring the mixing angle theta_13 by observing electron neutrino appearance via the sub-dominant muon neutrino to electron neutrino oscillation, and searching for CP violation in the lepton sector. The experiment include…
▽ More
The T2K experiment studies oscillations of an off-axis muon neutrino beam between the J-PARC accelerator complex and the Super-Kamiokande detector. Special emphasis is placed on measuring the mixing angle theta_13 by observing electron neutrino appearance via the sub-dominant muon neutrino to electron neutrino oscillation, and searching for CP violation in the lepton sector. The experiment includes a sophisticated, off-axis, near detector, the ND280, situated 280 m downstream of the neutrino production target in order to measure the properties of the neutrino beam and to understand better neutrino interactions at the energy scale below a few GeV. The data collected with the ND280 are used to study charged- and neutral-current neutrino interaction rates and kinematics prior to oscillation, in order to reduce uncertainties in the oscillation measurements by the far detector. A key element of the near detector is the ND280 electromagnetic calorimeter (ECal), consisting of active scintillator bars sandwiched between lead sheets and read outwith multi-pixel photon counters (MPPCs). The ECal is vital to the reconstruction of neutral particles, and the identification of charged particle species. The ECal surrounds the Pi-0 detector (P0D) and the tracking region of the ND280, and is enclosed in the former UA1/NOMAD dipole magnet. This paper describes the design, construction and assembly of the ECal, as well as the materials from which it is composed. The electronic and data acquisition (DAQ) systems are discussed, and performance of the ECal modules, as deduced from measurements with particle beams, cosmic rays, the calibration system, and T2K data, is described.
△ Less
Submitted 18 September, 2013; v1 submitted 15 August, 2013;
originally announced August 2013.
-
Characterisation of the muon beams for the Muon Ionisation Cooling Experiment
Authors:
The MICE Collaboration,
D. Adams,
D. Adey,
A. Alekou,
M. Apollonio,
R. Asfandiyarov,
J. Back,
G. Barber,
P. Barclay,
A. de Bari,
R. Bayes,
V. Bayliss,
R. Bertoni,
V. J. Blackmore,
A. Blondel,
S. Blot,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
U. Bravar,
A. D. Bross,
M. Capponi
, et al. (119 additional authors not shown)
Abstract:
A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.5--2.3 πmm-rad horizontally and 0.6--1.0 πmm-rad vertically, a horizontal dispersion of 90--190 mm and momentum spreads o…
▽ More
A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.5--2.3 πmm-rad horizontally and 0.6--1.0 πmm-rad vertically, a horizontal dispersion of 90--190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE.
△ Less
Submitted 11 October, 2013; v1 submitted 6 June, 2013;
originally announced June 2013.
-
The EUROnu Project
Authors:
T. R. Edgecock,
O. Caretta,
T. Davenne,
C. Densham,
M. Fitton,
D. Kelliher,
P. Loveridge,
S. Machida,
C. Prior,
C. Rogers,
M. Rooney,
J. Thomason,
D. Wilcox,
E. Wildner,
I. Efthymiopoulos,
R. Garoby,
S. Gilardoni,
C. Hansen,
E. Benedetto,
E. Jensen,
A. Kosmicki,
M. Martini,
J. Osborne,
G. Prior,
T. Stora
, et al. (146 additional authors not shown)
Abstract:
The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the…
▽ More
The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fréjus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of μ+ and μ- beams in a storage ring. The far detector in this case is a 100 kt Magnetised Iron Neutrino Detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fréjus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the physics reach of each facility, in particular for the measurement of CP violation in the lepton sector, and estimated the cost of construction. These have demonstrated that the best facility to build is the Neutrino Factory. However, if a powerful proton driver is constructed for another purpose or if the MEMPHYS detector is built for astroparticle physics, the Super Beam also becomes very attractive.
△ Less
Submitted 17 May, 2013;
originally announced May 2013.
-
Neutrinos from Stored Muons nuSTORM: Expression of Interest
Authors:
D. Adey,
S. K. Agarwalla,
C. M. Ankenbrandt,
R. Asfandiyarov,
J. J. Back,
G. Barker,
E. Baussan,
R. Bayes,
S. Bhadra,
V. Blackmore,
A. Blondel,
S. A. Bogacz,
C. Booth,
S. B. Boyd,
A. Bravar,
S. J. Brice,
A. D. Bross,
F. Cadoux,
H. Cease,
A. Cervera,
J. Cobb,
D. Colling,
L. Coney,
A. Dobbs,
J. Dobson
, et al. (84 additional authors not shown)
Abstract:
The nuSTORM facility has been designed to deliver beams of electron and muon neutrinos from the decay of a stored muon beam with a central momentum of 3.8 GeV/c and a momentum spread of 10%. The facility is unique in that it will: serve the future long- and short-baseline neutrino-oscillation programmes by providing definitive measurements of electron-neutrino- and muon-neutrino-nucleus cross sect…
▽ More
The nuSTORM facility has been designed to deliver beams of electron and muon neutrinos from the decay of a stored muon beam with a central momentum of 3.8 GeV/c and a momentum spread of 10%. The facility is unique in that it will: serve the future long- and short-baseline neutrino-oscillation programmes by providing definitive measurements of electron-neutrino- and muon-neutrino-nucleus cross sections with percent-level precision; allow searches for sterile neutrinos of exquisite sensitivity to be carried out; and constitute the essential first step in the incremental development of muon accelerators as a powerful new technique for particle physics.
Of the world's proton-accelerator laboratories, only CERN and FNAL have the infrastructure required to mount nuSTORM. Since no siting decision has yet been taken, the purpose of this Expression of Interest (EoI) is to request the resources required to: investigate in detail how nuSTORM could be implemented at CERN; and develop options for decisive European contributions to the nuSTORM facility and experimental programme wherever the facility is sited.
The EoI defines a two-year programme culminating in the delivery of a Technical Design Report.
△ Less
Submitted 7 May, 2013;
originally announced May 2013.
-
Using the past to constrain the future: how the palaeorecord can improve estimates of global warming
Authors:
Tamsin L. Edwards,
Michel Crucifix,
Sandy P. Harrison
Abstract:
Climate sensitivity is defined as the change in global mean equilibrium temperature after a doubling of atmospheric CO2 concentration and provides a simple measure of global warming. An early estimate of climate sensitivity, 1.5-4.5°C, has changed little subsequently, including the latest assessment by the Intergovernmental Panel on Climate Change.
The persistence of such large uncertainties in…
▽ More
Climate sensitivity is defined as the change in global mean equilibrium temperature after a doubling of atmospheric CO2 concentration and provides a simple measure of global warming. An early estimate of climate sensitivity, 1.5-4.5°C, has changed little subsequently, including the latest assessment by the Intergovernmental Panel on Climate Change.
The persistence of such large uncertainties in this simple measure casts doubt on our understanding of the mechanisms of climate change and our ability to predict the response of the climate system to future perturbations. This has motivated continued attempts to constrain the range with climate data, alone or in conjunction with models. The majority of studies use data from the instrumental period (post-1850) but recent work has made use of information about the large climate changes experienced in the geological past.
In this review, we first outline approaches that estimate climate sensitivity using instrumental climate observations and then summarise attempts to use the record of climate change on geological timescales. We examine the limitations of these studies and suggest ways in which the power of the palaeoclimate record could be better used to reduce uncertainties in our predictions of climate sensitivity.
△ Less
Submitted 21 April, 2012;
originally announced April 2012.
-
Measurements of the T2K neutrino beam properties using the INGRID on-axis near detector
Authors:
K. Abe,
N. Abgrall,
Y. Ajima,
H. Aihara,
J. B. Albert,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
D. Autiero,
A. Badertscher,
M. Barbi,
G. J. Barker,
G. Barr,
M. Bass,
M. Batkiewicz,
F. Bay,
S. Bentham,
V. Berardi,
B. E. Berger
, et al. (407 additional authors not shown)
Abstract:
Precise measurement of neutrino beam direction and intensity was achieved based on a new concept with modularized neutrino detectors. INGRID (Interactive Neutrino GRID) is an on-axis near detector for the T2K long baseline neutrino oscillation experiment. INGRID consists of 16 identical modules arranged in horizontal and vertical arrays around the beam center. The module has a sandwich structure o…
▽ More
Precise measurement of neutrino beam direction and intensity was achieved based on a new concept with modularized neutrino detectors. INGRID (Interactive Neutrino GRID) is an on-axis near detector for the T2K long baseline neutrino oscillation experiment. INGRID consists of 16 identical modules arranged in horizontal and vertical arrays around the beam center. The module has a sandwich structure of iron target plates and scintillator trackers. INGRID directly monitors the muon neutrino beam profile center and intensity using the number of observed neutrino events in each module. The neutrino beam direction is measured with accuracy better than 0.4 mrad from the measured profile center. The normalized event rate is measured with 4% precision.
△ Less
Submitted 14 November, 2011;
originally announced November 2011.
-
Absolute luminosity measurements with the LHCb detector at the LHC
Authors:
The LHCb Collaboration,
R. Aaij,
B. Adeva,
M. Adinolfi,
C. Adrover,
A. Affolder,
Z. Ajaltouni,
J. Albrecht,
F. Alessio,
M. Alexander,
G. Alkhazov,
P. Alvarez Cartelle,
A. A. Alves Jr,
S. Amato,
Y. Amhis,
J. Anderson,
R. B. Appleby,
O. Aquines Gutierrez,
F. Archilli,
L. Arrabito,
A. Artamonov,
M. Artuso,
E. Aslanides,
G. Auriemma,
S. Bachmann
, et al. (549 additional authors not shown)
Abstract:
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-prot…
▽ More
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.
△ Less
Submitted 11 January, 2012; v1 submitted 13 October, 2011;
originally announced October 2011.
-
MICE: the Muon Ionization Cooling Experiment. Step I: First Measurement of Emittance with Particle Physics Detectors
Authors:
U. Bravar,
M. Bogomilov,
Y. Karadzhov,
D. Kolev,
I. Russinov,
R. Tsenov,
L. Wang,
F. Y. Xu,
S. X. Zheng,
R. Bertoni,
M. Bonesini,
R. Mazza,
V. Palladino,
G. Cecchet,
A. de Bari,
M. Capponi,
A. Iaciofano,
D. Orestano,
F. Pastore,
L. Tortora,
S. Ishimoto,
S. Suzuki,
K. Yoshimura,
Y. Mori,
Y. Kuno
, et al. (123 additional authors not shown)
Abstract:
The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with…
▽ More
The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with time-of-flight and Cherenkov detectors to ensure a pure muon beam. The emittance of the incoming beam will be measured in the upstream magnetic spectrometer with a scintillating fiber tracker. A cooling cell will then follow, alternating energy loss in Liquid Hydrogen (LH2) absorbers to RF cavity acceleration. A second spectrometer, identical to the first, and a second muon identification system will measure the outgoing emittance. In the 2010 run at RAL the muon beamline and most detectors were fully commissioned and a first measurement of the emittance of the muon beam with particle physics (time-of-flight) detectors was performed. The analysis of these data was recently completed and is discussed in this paper. Future steps for MICE, where beam emittance and emittance reduction (cooling) are to be measured with greater accuracy, are also presented.
△ Less
Submitted 30 July, 2013; v1 submitted 9 October, 2011;
originally announced October 2011.
-
The T2K Experiment
Authors:
T2K Collaboration,
K. Abe,
N. Abgrall,
H. Aihara,
Y. Ajima,
J. B. Albert,
D. Allan,
P. -A. Amaudruz,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
C. Angelsen,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
J. P. A. M. de André,
D. Autiero,
A. Badertscher,
O. Ballester,
M. Barbi,
G. J. Barker,
P. Baron
, et al. (499 additional authors not shown)
Abstract:
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross…
▽ More
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem.
△ Less
Submitted 8 June, 2011; v1 submitted 6 June, 2011;
originally announced June 2011.