Skip to main content

Showing 1–14 of 14 results for author: Hargrove, C

Searching in archive physics. Search in all archives.
.
  1. arXiv:2107.06007  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The EXO-200 detector, part II: Auxiliary Systems

    Authors: N. Ackerman, J. Albert, M. Auger, D. J. Auty, I. Badhrees, P. S. Barbeau, L. Bartoszek, E. Baussan, V. Belov, C. Benitez-Medina, T. Bhatta, M. Breidenbach, T. Brunner, G. F. Cao, W. R. Cen, C. Chambers, B. Cleveland, R. Conley, S. Cook, M. Coon, W. Craddock, A. Craycraft, W. Cree, T. Daniels, L. Darroch , et al. (135 additional authors not shown)

    Abstract: The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op… ▽ More

    Submitted 22 October, 2021; v1 submitted 13 July, 2021; originally announced July 2021.

    Comments: Manuscript updated in response to JINST reviewer comments

  2. arXiv:1306.6106  [pdf, other

    nucl-ex hep-ex physics.ins-det

    An improved measurement of the 2νββ half-life of Xe-136 with EXO-200

    Authors: J. B. Albert, M. Auger, D. J. Auty, P. S. Barbeau, E. Beauchamp, D. Beck, V. Belov, C. Benitez-Medina, J. Bonatt, M. Breidenbach, T. Brunner, A. Burenkov, G. F. Cao, C. Chambers, J. Chaves, B. Cleveland, S. Cook, T. Daniels, M. Danilov, S. J. Daugherty, C. G. Davis, J. Davis, S. Delaquis, R. DeVoe, A. Dobi , et al. (72 additional authors not shown)

    Abstract: We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those… ▽ More

    Submitted 29 January, 2014; v1 submitted 25 June, 2013; originally announced June 2013.

    Comments: 34 pages, 32 figures, Updated to published version

    Journal ref: Phys. Rev. C 89, 015502 (2014)

  3. arXiv:1202.2192  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The EXO-200 detector, part I: Detector design and construction

    Authors: M. Auger, D. J. Auty, P. S. Barbeau, L. Bartoszek, E. Baussan, E. Beauchamp, C. Benitez-Medina, M. Breidenbach, D. Chauhan, B. Cleveland, R. Conley, J. Cook, S. Cook, A. Coppens, W. Craddock, T. Daniels, C. G. Davis, J. Davis, R. deVoe, A. Dobi, M. J. Dolinski, M. Dunford, W. Fairbank Jr, J. Farine, P. Fierlinger , et al. (56 additional authors not shown)

    Abstract: EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most… ▽ More

    Submitted 23 May, 2012; v1 submitted 10 February, 2012; originally announced February 2012.

    Journal ref: JINST 7 (2012) P05010

  4. arXiv:1109.1046  [pdf, ps, other

    physics.ins-det nucl-ex

    Xenon purity analysis for EXO-200 via mass spectrometry

    Authors: A. Dobi, C. Hall, S. Slutsky, Y. -R. Yen, B. Aharmin, M. Auger, P. S. Barbeau, C. Benitez-Medina, M. Breidenbach, B. Cleveland, R. Conley, J. Cook, S. Cook, I. Counts, W. Craddock, T. Daniels, C. G. Davis, J. Davis, R. deVoe, M. Dixit, M. J. Dolinski, K. Donato, W. Fairbank Jr., J. Farine, P. Fierlinger , et al. (51 additional authors not shown)

    Abstract: We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We ha… ▽ More

    Submitted 5 September, 2011; originally announced September 2011.

    Comments: 19 pages, 6 figures

  5. arXiv:1108.4193  [pdf, ps, other

    nucl-ex hep-ex physics.ins-det

    Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200

    Authors: N. Ackerman, B. Aharmim, M. Auger, D. J. Auty, P. S. Barbeau, K. Barry, L. Bartoszek, E. Beauchamp, V. Belov, C. Benitez-Medina, M. Breidenbach, A. Burenkov, B. Cleveland, R. Conley, E. Conti, J. Cook, S. Cook, A. Coppens, I. Counts, W. Craddock, T. Daniels, M. V. Danilov, C. G. Davis, J. Davis, R. deVoe , et al. (78 additional authors not shown)

    Abstract: We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, th… ▽ More

    Submitted 22 November, 2011; v1 submitted 21 August, 2011; originally announced August 2011.

  6. A xenon gas purity monitor for EXO

    Authors: EXO Collaboration, A. Dobi, C. Hall, S. Herrin, A. Odian, C. Y. Prescott, P. C. Rowson, N. Ackerman, B. Aharmin, M. Auger, P. S. Barbeau, K. Barry, C. Benitez-Medina, M. Breidenbach, S. Cook, I. Counts, T. Daniels, R. DeVoe, M. J. Dolinski, K. Donato, W. Fairbank Jr., J. Farine, G. Giroux, R. Gornea, K. Graham , et al. (35 additional authors not shown)

    Abstract: We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tu… ▽ More

    Submitted 9 June, 2011; originally announced June 2011.

    Comments: 41 pages, 26 figures

  7. arXiv:1104.5041  [pdf, ps, other

    physics.ins-det nucl-ex

    A magnetically-driven piston pump for ultra-clean applications

    Authors: F. LePort, R. Neilson, P. S. Barbeau, K. Barry, L. Bartoszek, I. Counts, J. Davis, R. deVoe, M. J. Dolinski, G. Gratta, M. Green, M. Montero Díez, A. R. Müller, K. O'Sullivan, A. Rivas, K. Twelker, B. Aharmim, M. Auger, V. Belov, C. Benitez-Medina, M. Breidenbach, A. Burenkov, B. Cleveland, R. Conley, J. Cook , et al. (55 additional authors not shown)

    Abstract: A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pum** more than 16 standard liters per minute (SL… ▽ More

    Submitted 26 April, 2011; originally announced April 2011.

    Comments: 6 pages, 5 figures

  8. arXiv:1008.3422  [pdf, other

    physics.atom-ph nucl-ex physics.ins-det

    A simple radionuclide-driven single-ion source

    Authors: M. Montero Díez, K. Twelker, W. Fairbank Jr., G. Gratta, P. S. Barbeau, K. Barry, R. DeVoe, M. J. Dolinski, M. Green, F. LePort, A. R. Müller, R. Neilson, K. O'Sullivan, N. Ackerman, B. Aharmin, M. Auger, C. Benitez-Medina, M. Breidenbach, A. Burenkov, S. Cook, T. Daniels, K. Donato, J. Farine, G. Giroux, R. Gornea , et al. (32 additional authors not shown)

    Abstract: We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detect… ▽ More

    Submitted 19 August, 2010; originally announced August 2010.

    Journal ref: Rev.Sci.Instrum.81:113301,2010

  9. arXiv:0906.2499  [pdf, other

    physics.ins-det hep-ex

    Characterization of large area APDs for the EXO-200 detector

    Authors: R. Neilson, F. LePort, A. Pocar, K. Kumar, A. Odian, C. Y. Prescott, V. Tenev, N. Ackerman, D. Akimov, M. Auger, C. Benitez-Medina, M. Breidenbach, A. Burenkov, R. Conley, S. Cook, R. deVoe, M. J. Dolinski, W. Fairbank Jr., J. Farine, P. Fierlinger, B. Flatt, R. Gornea, G. Gratta, M. Green, C. Hall , et al. (27 additional authors not shown)

    Abstract: EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more tha… ▽ More

    Submitted 13 June, 2009; originally announced June 2009.

    Comments: 10 pages, 17 figures

    Journal ref: Nucl.Instrum.Meth.A608:68-75,2009

  10. arXiv:0807.2895  [pdf, ps, other

    physics.ins-det physics.optics

    Wavelength Shifters for Water Cherenkov Detectors

    Authors: Xiongxin Dai, Etienne Rollin, Alain Bellerive, Cliff Hargrove, David Sinclair, Cathy Mifflin, Feng Zhang

    Abstract: The light yield of a water-based Cherenkov detector can be significantly improved by adding a wavelength shifter. Wavelength shifter (WLS) molecules absorb ultraviolet photons and re-emit them at longer wavelengths where typical photomultiplier tubes are more sensitive. In this study, several wavelength shifter compounds are tested for possible deployment in the Sudbury Neutrino Observatory (SNO… ▽ More

    Submitted 17 July, 2008; originally announced July 2008.

    Comments: 13 pages, 3 figures

    Journal ref: Nucl.Instrum.Meth.589:290-295,2008; Nucl.Instrum.Meth.A589:290-295,2008

  11. arXiv:0709.4524  [pdf, ps, other

    physics.ins-det nucl-ex

    Systematic study of trace radioactive impurities in candidate construction materials for EXO-200

    Authors: D. S. Leonard, P. Grinberg, P. Weber, E. Baussan, Z. Djurcic, G. Keefer, A. Piepke, A. Pocar, J. -L. Vuilleumier, J. -M. Vuilleumier, D. Akimov, A. Bellerive, M. Bowcock, M. Breidenbach, A. Burenkov, R. Conley, W. Craddock, M. Danilov, R. DeVoe, M. Dixit, A. Dolgolenko, I. Ekchtout, W. Fairbank Jr., J. Farine, P. Fierlinger , et al. (32 additional authors not shown)

    Abstract: The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma… ▽ More

    Submitted 4 August, 2008; v1 submitted 28 September, 2007; originally announced September 2007.

    Comments: 32 pages, 6 figures. Expanded introduction, added missing table entry. Accepted for publication in Nucl. Instrum. Meth. A

    Journal ref: Nucl.Instrum.Meth.A591:490-509,2008

  12. A linear RFQ ion trap for the Enriched Xenon Observatory

    Authors: B. Flatt, M. Green, J. Wodin, R. DeVoe, P. Fierlinger, G. Gratta, F. LePort, M. Montero Diez, R. Neilson, K. OSullivan, A. Pocar, S. Waldman, E. Baussan, M. Breidenbach, R. Conley, W. Fairbank Jr., J. Farine, C. Hall, K. Hall, D. Hallman, C. Hargrove, M. Hauger, J. Hodgson, F. Juget, D. S. Leonard , et al. (17 additional authors not shown)

    Abstract: The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the neutrinoless double-beta decay of $^{136}$Xe to $^{136}$Ba. To suppress possible backgrounds EXO will complement the measurement of decay energy and, to some extent, topology of candidate events in a Xe filled detector… ▽ More

    Submitted 12 April, 2007; originally announced April 2007.

    Comments: 18 pages, pdflatex, submitted to NIM A

    Journal ref: Nucl.Instrum.Meth.A578:399-408,2007

  13. arXiv:physics/0702122  [pdf, ps, other

    physics.atom-ph nucl-ex

    Observation of single collisionally cooled trapped ions in a buffer gas

    Authors: M. Green, J. Wodin, R. DeVoe, P. Fierlinger, B. Flatt, G. Gratta, F. LePort, M. Montero Diez, R. Neilson, K. OSullivan, A. Pocar, S. Waldman, D. S. Leonard, A. Piepke, C. Hargrove, D. Sinclair, V. Strickland, W. Fairbank Jr., K. Hall, B. Mong, M. Moe, J. Farine, D. Hallman, C. Virtue, E. Baussan , et al. (15 additional authors not shown)

    Abstract: Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of… ▽ More

    Submitted 5 July, 2007; v1 submitted 14 February, 2007; originally announced February 2007.

    Comments: 5 pages, 4 figures, accepted for publication in Phys. Rev. A. Minor text and figure changes

  14. arXiv:physics/0611183  [pdf, ps, other

    physics.ins-det nucl-ex

    A liquid xenon ionization chamber in an all-fluoropolymer vessel

    Authors: EXO Collaboration, F. LePort, A. Pocar, L. Bartoszek, R. DeVoe, P. Fierlinger, B. Flatt, G. Gratta, M. Green, T. Koffas, M. Montero Diez, R. Neilson, K. O'Sullivan, S. Waldman, J. Wodin, D. Woisard, E. Baussan, M. Breidenbach, R. Conley, W. Fairbank Jr., J. Farine, C. Hall, K. Hall, D. Hallman, C. Hargrove , et al. (20 additional authors not shown)

    Abstract: A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.

    Submitted 19 November, 2006; originally announced November 2006.

    Comments: 12 pages, 9 figures

    Journal ref: Nucl.Instrum.Meth.A578:409-420,2007