-
Proposed large scale monolithic fused silica mirror suspension for 3rd generation gravitational wave detectors
Authors:
A. V. Cumming,
R. Jones,
G. D. Hammond,
J. Hough,
I. W. Martin,
S. Rowan
Abstract:
Thermal noise from the suspension fibres used in the mirror pendulums in current gravitational wave detectors is a critical noise source. Future detectors will require improved suspension performance with the specific ability to suspend much heavier masses to reduce radiation pressure noise, whilst retaining good thermal noise performance. In this letter, we propose and experimentally demonstrate…
▽ More
Thermal noise from the suspension fibres used in the mirror pendulums in current gravitational wave detectors is a critical noise source. Future detectors will require improved suspension performance with the specific ability to suspend much heavier masses to reduce radiation pressure noise, whilst retaining good thermal noise performance. In this letter, we propose and experimentally demonstrate a design for a large-scale fused silica suspension, demonstrating its suitability for holding an increased mass of 160 kg. We demonstrate the concepts for improving thermal noise via longer suspension fibres supporting a higher static stress. We present a full thermal noise analysis of our prototype, meeting requirements for conceptual 3rd generation detector designs such as the high frequency interferometer of the Einstein Telescope (ET-HF), and closely approaching that required for Cosmic Explorer (CE).
△ Less
Submitted 17 November, 2021;
originally announced November 2021.
-
A Nineteen Day Earth Tide Measurement with a MEMS Gravimeter
Authors:
A. Prasad,
R. P. Middlemiss,
K. Anastasiou,
S. G. Bramsiepe,
A. Noack,
D. J. Paul,
K. Toland,
P. R. Utting,
G. D. Hammond
Abstract:
The measurement of tiny variations in local gravity enables the observation of subterranean features. Gravimeters have historically been extremely expensive instruments, but usable gravity measurements have recently been conducted using MEMS (microelectromechanical systems) sensors. Such sensors are cheap to produce, since they rely on the same fabrication techniques used to produce mobile phone a…
▽ More
The measurement of tiny variations in local gravity enables the observation of subterranean features. Gravimeters have historically been extremely expensive instruments, but usable gravity measurements have recently been conducted using MEMS (microelectromechanical systems) sensors. Such sensors are cheap to produce, since they rely on the same fabrication techniques used to produce mobile phone accelerometers. A significant challenge in the development of MEMS gravimeters is maintaining stability over long time periods, which is essential for long term monitoring applications. A standard way to demonstrate gravimeter stability and sensitivity is to measure the periodic elastic distortion of the Earth due to tidal forces - the Earth tides. Here we present a nineteen day measurement of the Earth tides, with a correlation coefficient to the theoretical signal of 0.979. The estimated bias instability of the proposed gravimeter is 8.18 microGal for an averaging time of ~400 s when considering the raw, uncompensated data. The bias instability extracted from the sensor electronic noise sits just under 2 mircoGal for an averaging time of ~200 s. After removing the long-term temperature and control electronics effects from the raw data, a linear drift of 268 microGal/day is observed in the data, which is among one of the best reported for a MEMS device. These results demonstrate that this MEMS gravimeter is capable of conducting long-therm time-lapse gravimetry, a functionality essential for applications such as volcanology.
△ Less
Submitted 28 September, 2021;
originally announced September 2021.
-
A MEMS gravimeter with multi-axis gravitational sensitivity
Authors:
Richard P. Middlemiss,
Paul Campsie,
William Cunningham,
Rebecca Douglas,
Victoria McIvor,
James Hough,
Sheila Rowan,
Douglas J. Paul,
Abhinav Prasad,
G. D. Hammond
Abstract:
A single-axis Microelectromechanical system gravimeter has recently been developed at the University of Glasgow. The sensitivity and stability of this device was demonstrated by measuring the Earth tides. The success of this device was enabled in part by its extremely low resonant frequency. This low frequency was achieved with a geometric anti-spring design, fabricated using well-established phot…
▽ More
A single-axis Microelectromechanical system gravimeter has recently been developed at the University of Glasgow. The sensitivity and stability of this device was demonstrated by measuring the Earth tides. The success of this device was enabled in part by its extremely low resonant frequency. This low frequency was achieved with a geometric anti-spring design, fabricated using well-established photolithography and dry etch techniques. Analytical models can be used to calculate the results of these non-linear oscillating systems, but the power of finite element analysis has not been fully utilised to explore the parameter space before now. In this article, the results of previous analytical solutions are replicated using finite element models, before applying the same techniques to optimise the design of the gravimeter. These computer models provide the ability to investigate the effect of the fabrication material of the device: anisotropic <100> crystalline silicon. This is a parameter that is difficult to investigate analytically, but finite element modelling is demonstrated here to provide accurate predictions of real gravimeter behaviour by taking anisotropy into account. The finite element models are then used to demonstrate the design of a three-axis gravimeter enabling the gravity tensor to be measured - a significantly more powerful surveying tool than the original single-axis device.
△ Less
Submitted 10 February, 2021;
originally announced February 2021.
-
A High Stability Optical Shadow Sensor with Applications for Precision Accelerometers
Authors:
Steven G Bramsiepe,
David Loomes,
Richard P Middlemiss,
Douglas J Paul,
Giles D Hammond
Abstract:
Gravimeters are devices which measure changes in the value of the gravitational acceleration, \textit{g}. This information is used to infer changes in density under the ground allowing the detection of subsurface voids; mineral, oil and gas reserves; and even the detection of the precursors of volcanic eruptions. A micro-electro mechanical system (MEMS) gravimeter has been fabricated completely in…
▽ More
Gravimeters are devices which measure changes in the value of the gravitational acceleration, \textit{g}. This information is used to infer changes in density under the ground allowing the detection of subsurface voids; mineral, oil and gas reserves; and even the detection of the precursors of volcanic eruptions. A micro-electro mechanical system (MEMS) gravimeter has been fabricated completely in silicon allowing the possibility of cost e-effective, lightweight and small gravimeters. To obtain a measurement of gravity, a highly stable displacement measurement of the MEMS is required. This requires the development of a portable electronics system that has a displacement sensitivity of $\leq 2.5$ nm over a period of a day or more. The portable electronics system presented here has a displacement sensitivity $\leq 10$ nm$/\sqrt{\textrm{Hz}}$ ($\leq 0.6$ nm at $1000$ s). The battery power system used a modulated LED for measurements and required temperature control of the system to $\pm$ 2 mK, monitoring of the tilt to $\pm$ 2 $μ$radians, the storage of measured data and the transmission of the data to an external server.
△ Less
Submitted 3 November, 2017;
originally announced November 2017.
-
Design of a speed meter interferometer proof-of-principle experiment
Authors:
C. Gräf,
B. W. Barr,
A. S. Bell,
F. Campbell,
A. V. Cumming,
S. L. Danilishin,
N. A. Gordon,
G. D. Hammond,
J. Hennig,
E. A. Houston,
S. H. Huttner,
R. A. Jones,
S. S. Leavey,
H. Lück,
J. Macarthur,
M. Marwick,
S. Rigby,
R. Schilling,
B. Sorazu,
A. Spencer,
S. Steinlechner,
K. A. Strain,
S. Hild
Abstract:
The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of develo…
▽ More
The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of development are being pursued to reach this goal, focusing both on modifications of the well-established Michelson detector configuration and development of different detector topologies. In this paper, we present the design of the world's first Sagnac speed meter interferometer which is currently being constructed at the University of Glasgow. With this proof-of-principle experiment we aim to demonstrate the theoretically predicted lower quantum noise in a Sagnac interferometer compared to an equivalent Michelson interferometer, to qualify Sagnac speed meters for further research towards an implementation in a future generation large scale gravitational wave detector, such as the planned Einstein Telescope observatory.
△ Less
Submitted 11 September, 2014; v1 submitted 12 May, 2014;
originally announced May 2014.