Skip to main content

Showing 1–5 of 5 results for author: Hammond, G D

Searching in archive physics. Search in all archives.
.
  1. arXiv:2111.09119  [pdf

    astro-ph.IM physics.ins-det

    Proposed large scale monolithic fused silica mirror suspension for 3rd generation gravitational wave detectors

    Authors: A. V. Cumming, R. Jones, G. D. Hammond, J. Hough, I. W. Martin, S. Rowan

    Abstract: Thermal noise from the suspension fibres used in the mirror pendulums in current gravitational wave detectors is a critical noise source. Future detectors will require improved suspension performance with the specific ability to suspend much heavier masses to reduce radiation pressure noise, whilst retaining good thermal noise performance. In this letter, we propose and experimentally demonstrate… ▽ More

    Submitted 17 November, 2021; originally announced November 2021.

    Comments: 7 pages, 5 figures

  2. arXiv:2109.13715  [pdf, other

    physics.ins-det physics.app-ph physics.geo-ph

    A Nineteen Day Earth Tide Measurement with a MEMS Gravimeter

    Authors: A. Prasad, R. P. Middlemiss, K. Anastasiou, S. G. Bramsiepe, A. Noack, D. J. Paul, K. Toland, P. R. Utting, G. D. Hammond

    Abstract: The measurement of tiny variations in local gravity enables the observation of subterranean features. Gravimeters have historically been extremely expensive instruments, but usable gravity measurements have recently been conducted using MEMS (microelectromechanical systems) sensors. Such sensors are cheap to produce, since they rely on the same fabrication techniques used to produce mobile phone a… ▽ More

    Submitted 28 September, 2021; originally announced September 2021.

    Comments: 25 pages, 5 figures

  3. arXiv:2102.05528  [pdf, other

    physics.app-ph

    A MEMS gravimeter with multi-axis gravitational sensitivity

    Authors: Richard P. Middlemiss, Paul Campsie, William Cunningham, Rebecca Douglas, Victoria McIvor, James Hough, Sheila Rowan, Douglas J. Paul, Abhinav Prasad, G. D. Hammond

    Abstract: A single-axis Microelectromechanical system gravimeter has recently been developed at the University of Glasgow. The sensitivity and stability of this device was demonstrated by measuring the Earth tides. The success of this device was enabled in part by its extremely low resonant frequency. This low frequency was achieved with a geometric anti-spring design, fabricated using well-established phot… ▽ More

    Submitted 10 February, 2021; originally announced February 2021.

  4. A High Stability Optical Shadow Sensor with Applications for Precision Accelerometers

    Authors: Steven G Bramsiepe, David Loomes, Richard P Middlemiss, Douglas J Paul, Giles D Hammond

    Abstract: Gravimeters are devices which measure changes in the value of the gravitational acceleration, \textit{g}. This information is used to infer changes in density under the ground allowing the detection of subsurface voids; mineral, oil and gas reserves; and even the detection of the precursors of volcanic eruptions. A micro-electro mechanical system (MEMS) gravimeter has been fabricated completely in… ▽ More

    Submitted 3 November, 2017; originally announced November 2017.

    Comments: 8 Pages, 12 figures, 5 equations, currently submitted and under review at IEEE Sensors SIEL

  5. arXiv:1405.2783  [pdf, ps, other

    gr-qc physics.optics quant-ph

    Design of a speed meter interferometer proof-of-principle experiment

    Authors: C. Gräf, B. W. Barr, A. S. Bell, F. Campbell, A. V. Cumming, S. L. Danilishin, N. A. Gordon, G. D. Hammond, J. Hennig, E. A. Houston, S. H. Huttner, R. A. Jones, S. S. Leavey, H. Lück, J. Macarthur, M. Marwick, S. Rigby, R. Schilling, B. Sorazu, A. Spencer, S. Steinlechner, K. A. Strain, S. Hild

    Abstract: The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of develo… ▽ More

    Submitted 11 September, 2014; v1 submitted 12 May, 2014; originally announced May 2014.

    Comments: Revised version: 16 pages, 6 figures

    Journal ref: Class. Quantum Grav. 31 215009 (2014)