-
Novel method for in-situ drift velocity measurement in large volume TPCs: the Geometry Reference Chamber of the NA61/SHINE experiment at CERN
Authors:
Andras Laszlo,
Adam Gera,
Gergo Hamar,
Botond Palfi,
Piotr Podlaski,
Brant Rumberger,
Dezso Varga
Abstract:
This paper presents a novel method for low maintenance, low ambiguity in-situ drift velocity monitoring in large volume Time Projection Chambers (TPCs). The method was developed and deployed for the 40m^3 TPC tracker system of the NA61/SHINE experiment at CERN, which has a one meter of drift length. The method relies on a low-cost multi-wire proportional chamber (MWPC) placed downstream of the TPC…
▽ More
This paper presents a novel method for low maintenance, low ambiguity in-situ drift velocity monitoring in large volume Time Projection Chambers (TPCs). The method was developed and deployed for the 40m^3 TPC tracker system of the NA61/SHINE experiment at CERN, which has a one meter of drift length. The method relies on a low-cost multi-wire proportional chamber (MWPC) placed downstream of the TPCs to be monitored. The drift velocity is then determined by matching the reconstructed tracks in the TPC to the hits of the pertinent monitoring chamber, called Geometry Reference Chamber (GRC), which is then used as a differential length scale. An important design requirement on the GRC was minimal added complexity to the existing system, in particular, compatibility with Front-End Electronics (FEE) cards already used to read out the TPCs. Moreover, the GRC system was designed to operate both in large and small particle flux. The system is capable of monitoring the evolution of the in-situ drift velocity down to a one permil precision, with a few minutes of time sampling.
△ Less
Submitted 2 May, 2024;
originally announced May 2024.
-
Characterisation of plastic scintillator paddles and lightweight MWPCs for the MID subsystem of ALICE 3
Authors:
Ruben Alfaro,
Mauricio Alvarado Hernández,
Gyula Bencédi,
Juan Carlos Cabanillas Noris,
Marco Antonio Díaz Maldonado,
Carlos Duarte Galvan,
Arturo Fernández Téllez,
Gergely Gábor Barnaföldi,
Ádám Gera,
Varlen Grabsky,
Gergő Hamar,
Gerardo Herrera Corral,
Ildefonso León Monzón,
Josué Martínez García,
Mario Iván Martínez Hernandez,
Jesús Eduardo Muñoz Méndez,
Richárd Nagy,
Rafael Ángel Narcio Laveaga,
Antonio Ortiz,
Mario Rodríguez Cahuantzi,
Solangel Rojas Torres,
Timea Szollosova,
Miguel Enrique Patiño Salazar,
Jared Pazarán García,
Hector David Regules Medel
, et al. (7 additional authors not shown)
Abstract:
The ALICE collaboration is proposing a completely new detector, ALICE 3, for operation during the LHC Runs 5 and 6. One of the ALICE~3 subsystems is the Muon IDentifier detector (MID), which has to be optimised to be efficient for the reconstruction of $J/ψ$ at rest (muons down to $p_{\rm T}\approx1.5$ GeV/$c$) for $|η|<1.3$. Given the modest particle flux expected in the MID of a few Hz/cm$^2$, t…
▽ More
The ALICE collaboration is proposing a completely new detector, ALICE 3, for operation during the LHC Runs 5 and 6. One of the ALICE~3 subsystems is the Muon IDentifier detector (MID), which has to be optimised to be efficient for the reconstruction of $J/ψ$ at rest (muons down to $p_{\rm T}\approx1.5$ GeV/$c$) for $|η|<1.3$. Given the modest particle flux expected in the MID of a few Hz/cm$^2$, technologies like plastic scintillator bars ($\approx1$ m length) equipped with wavelength-shifting fibers and silicon photomultiplier readout, and lightweight Multi-Wire Proportional Chambers (MWPCs) are under investigation. To this end, different plastic scintillator paddles and MWPCs were studied at the CERN T10 test beam facility. This paper reports on the performance of the scintillator prototypes tested at different beam momenta (from 0.5 GeV/$c$ up to 6 GeV/$c$) and positions (horizontal, vertical, and angular scans). The MWPCs were tested at different momenta (from 0.5 GeV/$c$ to 10 GeV/$c$) and beam intensities, their efficiency and position resolutions were verified beyond the particle rates expected with the MID in ALICE 3.
△ Less
Submitted 16 February, 2024; v1 submitted 9 January, 2024;
originally announced January 2024.
-
3D Muographic Inversion in the Exploration of Cavities and Low-density Fractured Zones
Authors:
László Balázs,
Gábor Nyitrai,
Gergely Surányi,
Gergő Hamar,
Gergely Gábor Barnaföldi,
Dezső Varga
Abstract:
Muography is an imaging tool based on the attenuation of cosmic muons to observe the density distribution of large objects, such as underground caves or fractured zones. Tomography based on muography measurements -- that is, three dimensional reconstruction of density distribution from two dimensional muon flux maps -- brings up special challenges. The detector field of view covering must be as ba…
▽ More
Muography is an imaging tool based on the attenuation of cosmic muons to observe the density distribution of large objects, such as underground caves or fractured zones. Tomography based on muography measurements -- that is, three dimensional reconstruction of density distribution from two dimensional muon flux maps -- brings up special challenges. The detector field of view covering must be as balanced as possible, considering the muon flux drop at higher zenith angles and the detector placement possibilities. The inversion from directional muon fluxes to 3D density map is usually underdetermined (more voxels than measurements) which can be unstable due to partial coverage. This can be solved by geologically relevant Bayesian constraints. The Bayesian principle results in parameter bias and artifacts. In this work, the linearized (density-length based) inversion is applied, the methodology is explained, formulating the constraints associated with inversion to ensure the stability of parameter fitting. After testing the procedure on synthetic examples, an actual high quality muography measurement data set from 7 positions is used as input for the inversion. The result demonstrates the tomographic imaging of a complex karstic crack zone and provides details on the complicated internal structures. The existence of low density zones in the imaged space was verified by samples from core drills, which consist altered dolomite powder within the intact high density dolomite.
△ Less
Submitted 21 September, 2023;
originally announced September 2023.
-
Towards low gas consumption of muographic tracking detectors in field applications
Authors:
Gábor Nyitrai,
Gergő Hamar,
Dezső Varga
Abstract:
Gaseous detectors are widely used in high energy physics, and are attractive choices in tracking systems for cosmic muon imaging, also called muography. Such detectors offer high resolution and high efficiency at reasonable cost for large sizes, however, one of the drawbacks is that the gaseous detection medium must be prevented from contamination by outside air or internal outgassing. Standard sy…
▽ More
Gaseous detectors are widely used in high energy physics, and are attractive choices in tracking systems for cosmic muon imaging, also called muography. Such detectors offer high resolution and high efficiency at reasonable cost for large sizes, however, one of the drawbacks is that the gaseous detection medium must be prevented from contamination by outside air or internal outgassing. Standard systems work with a constant gas flow, leading to regular maintenance in the form of gas cylinder changes, which can be an issue for remote field applications. In this paper we discuss the practical possibilities to reduce gas consumption of an outdoor gaseous tracker, where particularly the gas density change from daily temperature cycling limits the input flow. Such "breathing" effect can be circumvented by well designed buffer volume, which must prevent external air contamination. A realistic MWPC tracking test system with 0.9 square meter area, total volume of 160 l, has been operated for 36 days with a flow of 3 l/day, confirming that the buffer volume, in this case a 50 m long and 10 l volume low diffusion tube, ensures sufficient gas quality. The key effects governing the gas flow dynamics, including diffusion and gas volume change, has been studied quantitatively, leading to practical design prescriptions.
△ Less
Submitted 20 May, 2021;
originally announced May 2021.
-
The upgrade of the ALICE TPC with GEMs and continuous readout
Authors:
J. Adolfsson,
M. Ahmed,
S. Aiola,
J. Alme,
T. Alt,
W. Amend,
F. Anastasopoulos,
C. Andrei,
M. Angelsmark,
V. Anguelov,
A. Anjam,
H. Appelshäuser,
V. Aprodu,
O. Arnold,
M. Arslandok,
D. Baitinger,
M. Ball,
G. G. Barnaföldi,
E. Bartsch,
P. Becht,
R. Bellwied,
A. Berdnikova,
M. Berger,
N. Bialas,
P. Bialas
, et al. (210 additional authors not shown)
Abstract:
The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous re…
▽ More
The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous readout electronics based on the SAMPA chip, an ALICE development, are replacing the previous elements. The construction of these new elements, together with their associated quality control procedures, is explained in detail. Finally, the readout chamber and front-end electronics cards replacement, together with the commissioning of the detector prior to installation in the experimental cavern, are presented. After a nine-year period of R&D, construction, and assembly, the upgrade of the TPC was completed in 2020.
△ Less
Submitted 25 March, 2021; v1 submitted 17 December, 2020;
originally announced December 2020.
-
A GEM based TPC for beam monitoring
Authors:
Gábor Galgóczi,
Gergő Hamar,
Péter Pázmándi,
Dezső Varga
Abstract:
In recent years Gas Electron Multipliers have proven to be reliable amplification stages at high beam rates, and can be used also in Time Projection Chambers. Our group developed a 1 dm$^3$ active volume double-GEM TPC, with spatial resolution of 50 $μm$ and 280 $μ$m. Custom designed FPGA data acquisition system enables rate capability for about 100 kHz$\cdot$mm$^{-2}$, providing excellent track-b…
▽ More
In recent years Gas Electron Multipliers have proven to be reliable amplification stages at high beam rates, and can be used also in Time Projection Chambers. Our group developed a 1 dm$^3$ active volume double-GEM TPC, with spatial resolution of 50 $μm$ and 280 $μ$m. Custom designed FPGA data acquisition system enables rate capability for about 100 kHz$\cdot$mm$^{-2}$, providing excellent track-by-track position and angular information, better than 0.1 mm and 1 mrad respectively. The wide dynamic range of the system enables identification from $^{4}$He up to $^{86}$Kr using ionization measurement. Two of these TPCs are planned to operate in tandem mode to filter off-time particles and to achieve a superior angular resolution.
△ Less
Submitted 4 September, 2020;
originally announced September 2020.
-
MPGD-based photon detectors for the upgrade of COMPASS RICH-1 and beyond
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
L. García Ordóñez,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri
, et al. (7 additional authors not shown)
Abstract:
COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly de…
▽ More
COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly developed MPGD-based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a Micromegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during the 2016 COMPASS data taking and stably operated during the 2017 run. In this paper design, construction, operation and performance aspects of the novel photon detectors for COMPASS RICH-1 are discussed.
△ Less
Submitted 18 June, 2020;
originally announced June 2020.
-
Imaging by muons and their induced secondary particles -- a novel technique
Authors:
G. Galgóczi,
D. Mrdja,
I. Bikit,
K. Bikit,
J. Slivka,
J. Hansman,
L. Oláh,
G. Hamar,
D. Varga
Abstract:
Muography is a well estabilished method to obtain 3D images of large objects (e.g. volcanoes and large buildings) without any additional particle source, taking advantage of the presence of cosmic muons. The underlying principle of muography is the measurement of individual muon tracks and the determination of their absorption or scattering. These processes depend on the material that they have tr…
▽ More
Muography is a well estabilished method to obtain 3D images of large objects (e.g. volcanoes and large buildings) without any additional particle source, taking advantage of the presence of cosmic muons. The underlying principle of muography is the measurement of individual muon tracks and the determination of their absorption or scattering. These processes depend on the material that they have travelled through. The novel method discussed is based on the measurement of the muon tracks and of the corresponding particles those were produced by the muons themselves in the investigated target. As muons pass through matter they interact with matter by ionization, bremsstrahlung, pair production and nuclear interactions. Our experimental setup is designed in a way to measure both the primary muons and the created secondaries (mostly electrons and gammas). The tracks of the muons are determined by a special kind of Multi-Wire Proportional Chambers (MWPC) called CCC (Close Cathode Chamber). The secondary particles produced in the target are measured by four plastic scintillators placed around the target. The CCC chambers and the scintillators are used in coincidence in order to gather data about muons those passed through the target. As cross sections of the described processes vary by the density and the atomic number of materials this technique could be used to investigate the material content of the target.
△ Less
Submitted 30 January, 2020;
originally announced January 2020.
-
Direct measurements of the properties of Thick-GEM reflective photocathodes
Authors:
G. Hamar,
M. Baruzzo,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. S. Dasgupta,
B. Gobbo,
M. Gregori,
S. Levorato,
G. Menon,
C. A. Santos,
F. Tessarotto,
P. Triloki,
D. Varga,
Y. X. Zhao
Abstract:
In the context of the development of novel Thick GEM based detectors of single photons, the high resolution optical system, nicknamed Leopard, providing a detailed surface scanning of the Thick GEM electron multipliers, has been used for a set of systematic measurements of key Thick GEM properties. These results are reported and discussed. They confirm by direct observation Thick GEM properties pr…
▽ More
In the context of the development of novel Thick GEM based detectors of single photons, the high resolution optical system, nicknamed Leopard, providing a detailed surface scanning of the Thick GEM electron multipliers, has been used for a set of systematic measurements of key Thick GEM properties. These results are reported and discussed. They confirm by direct observation Thick GEM properties previously inferred by indirect measurements and answer to relevant questions related to the use of Thick GEMs as photocathode substrates in novel gaseous photon detectors.
△ Less
Submitted 11 October, 2019;
originally announced October 2019.
-
A modular mini-pad photon detector prototype for RICH application at the Electron Ion Collider
Authors:
J. Agarwala,
C. D. R. Azevedo,
C. Chatterjee,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. DallaTorre,
S. Dasgupta,
M. Gregori,
G. Hamar,
S. Levorato,
G. Menon,
F. Tessarotto,
Y. X. Zhao
Abstract:
Experiments at the future Electron Ion Collider require excellent hadron identification in a broad momentum range, in harsh conditions. A RICH capable to fulfill the PID requirements of the EIC could use MPGD-based photon detectors with solid photocathodes for covering large surfaces at affordable cost, providing good efficiency, high resolution and compatibility with magnetic field. Photon detect…
▽ More
Experiments at the future Electron Ion Collider require excellent hadron identification in a broad momentum range, in harsh conditions. A RICH capable to fulfill the PID requirements of the EIC could use MPGD-based photon detectors with solid photocathodes for covering large surfaces at affordable cost, providing good efficiency, high resolution and compatibility with magnetic field. Photon detectors realized by coupling THGEMs and Micromegas have been successfully operated at the RICH-1 detector of the COMPASS Experiment at CERN since 2016. A similar technology could be envisaged for an EIC RICH, provided a large improvement in the photon position resolution is achieved. An R\&D effort in this direction is ongoing at INFN Trieste. Few prototypes with smaller pixel size (down to 3 mm x 3 mm) have been built and tested in the laboratory with X-Ray and UV LED light sources. A modular mini-pad detector prototype has also been tested at the CERN SPS H4 beamline. New data acquisition and analysis software called Raven DAQ and Raven Decoder have been developed and used with the APV-25 based Scalable Readout System (SRS), for the modular mini-pad prototype tests.
△ Less
Submitted 14 August, 2019;
originally announced August 2019.
-
The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
M. Chiosso,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai,
S. Schopferer,
M. Slunecka
, et al. (4 additional authors not shown)
Abstract:
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m…
▽ More
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. They are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also indicated.
△ Less
Submitted 20 July, 2019;
originally announced July 2019.
-
The high voltage system with pressure and temperature corrections for the novel MPGD-based photon detectors of COMPASS RICH-1
Authors:
J. Agarwala,
M. Bari,
F. Bradamante,
A. Bressan,
C. Chatterjee,
A. Cicuttin,
P. Ciliberti,
M. Crespo,
S. Dalla Torre,
S. Dasgupta,
B. Gobbo,
M. Gregori,
G. Hamar,
S. Levorato,
A. Martin,
G. Menon,
L. B. Rizzuto,
Triloki,
F. Tessarotto,
Y. X. Zhao
Abstract:
The novel MPGD-based photon detectors of COMPASS RICH-1 consist of large-size hybrid MPGDs with multi-layer architecture including two layers of Thick-GEMs and a bulk resistive MicroMegas. The top surface of the first THGEM is coated with a CsI film which also acts as photo-cathode. These detectors have been successfully in operation at COMPASS since 2016. Concerning bias-voltage supply, the Thick…
▽ More
The novel MPGD-based photon detectors of COMPASS RICH-1 consist of large-size hybrid MPGDs with multi-layer architecture including two layers of Thick-GEMs and a bulk resistive MicroMegas. The top surface of the first THGEM is coated with a CsI film which also acts as photo-cathode. These detectors have been successfully in operation at COMPASS since 2016. Concerning bias-voltage supply, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MicroMegas anode is segmented into pads individually biased with positive voltage while the micromesh is grounded. In total, there are about ten different electrode types and more than 20000 electrodes supplied by more than 100 HV channels, where appropriate correlations among the applied voltages are required for the correct operation of the detectors. Therefore, a robust control system is mandatory, implemented by a custom designed software package, while commercial power supply units are used. This sophisticated control system allows to protect the detectors against errors by the operator, to monitor and log voltages and currents at 1 Hz rate, and automatically react to detector misbehaviour. In addition, a voltage compensation system has been developed to automatically adjust the biasing voltage according to environmental pressure and temperature variations, to achieve constant gain over time. This development answers to a more general need. In fact, voltage compensation is always a requirement for the stability of gaseous detectors and its need is enhanced in multi-layer ones.
In this paper, the HV system and its performance are described in details, as well as the stability of the novel MPGD-based photon detectors during the physics data taking at COMPASS.
△ Less
Submitted 4 July, 2019;
originally announced July 2019.
-
The Hybrid MPGD-based photon detectors of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buechele,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai
, et al. (6 additional authors not shown)
Abstract:
Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution o…
▽ More
Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution of ~ 1.8 mrad and about 10 detected photons per ring at saturation. The main aspects of their construction and commissioning, their characterization and performance figures are presented.
△ Less
Submitted 17 December, 2018;
originally announced December 2018.
-
Long term measurements from the Mátra Gravitational and Geophysical Laboratory
Authors:
P. Ván,
G. G. Barnaföldi,
T. Bulik,
T. Biró,
S. Czellár,
M. Cieślar,
Cs. Czanik,
E. Dávid,
E. Debreceni,
M. Denys,
M. Dobróka,
E. Fenyvesi,
D. Gondek-Rosińska,
Z. Gráczer,
G. Hamar,
G. Huba,
B. Kacskovics,
Á. Kis,
I. Kovács,
R. Kovács,
I. Lemperger,
P. Lévai,
S. Lökös,
J. Mlynarczyk,
J. Molnár
, et al. (15 additional authors not shown)
Abstract:
Summary of the long term data taking, related to one of the proposed next generation ground-based gravitational detector's location is presented here. Results of seismic and infrasound noise, electromagnetic attenuation and cosmic muon radiation measurements are reported in the underground Matra Gravitational and Geophysical Laboratory near Gyöngyösoroszi, Hungary. The collected seismic data of mo…
▽ More
Summary of the long term data taking, related to one of the proposed next generation ground-based gravitational detector's location is presented here. Results of seismic and infrasound noise, electromagnetic attenuation and cosmic muon radiation measurements are reported in the underground Matra Gravitational and Geophysical Laboratory near Gyöngyösoroszi, Hungary. The collected seismic data of more than two years is evaluated from the point of view of the Einstein Telescope, a proposed third generation underground gravitational wave observatory. Applying our results for the site selection will significantly improve the signal to nose ratio of the multi-messenger astrophysics era, especially at the low frequency regime.
△ Less
Submitted 13 November, 2018;
originally announced November 2018.
-
Letter of Intent: A New QCD facility at the M2 beam line of the CERN SPS (COMPASS++/AMBER)
Authors:
B. Adams,
C. A. Aidala,
R. Akhunzyanov,
G. D. Alexeev,
M. G. Alexeev,
A. Amoroso,
V. Andrieux,
N. V. Anfimov,
V. Anosov,
A. Antoshkin,
K. Augsten,
W. Augustyniak,
C. D. R. Azevedo,
A. Azhibekov,
B. Badelek,
F. Balestra,
M. Ball,
J. Barth,
R. Beck,
Y. Bedfer,
J. Berenguer Antequera,
J. C. Bernauer,
J. Bernhard,
M. Bodlak,
P. Bordalo
, et al. (242 additional authors not shown)
Abstract:
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
△ Less
Submitted 25 January, 2019; v1 submitted 2 August, 2018;
originally announced August 2018.
-
The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1 and beyond
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
M. Chiosso,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai,
S. Schopferer,
M. Slunecka
, et al. (4 additional authors not shown)
Abstract:
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m…
▽ More
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. These detectors are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also presented.
△ Less
Submitted 2 July, 2018;
originally announced July 2018.
-
Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade
Authors:
M. M. Aggarwal,
Z. Ahammed,
S. Aiola,
J. Alme,
T. Alt,
W. Amend,
A. Andronic,
V. Anguelov,
H. Appelshäuser,
M. Arslandok,
R. Averbeck,
M. Ball,
G. G. Barnaföldi,
E. Bartsch,
R. Bellwied,
G. Bencedi,
M. Berger,
N. Bialas,
P. Bialas,
L. Bianchi,
S. Biswas,
L. Boldizsár,
L. Bratrud,
P. Braun-Munzinger,
M. Bregant
, et al. (155 additional authors not shown)
Abstract:
A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivit…
▽ More
A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivity to rare probes that are considered key observables to characterize the QCD matter created in such collisions. In order to make full use of this luminosity, the currently used gated Multi-Wire Proportional Chambers will be replaced. The upgrade relies on continuously operated readout detectors employing Gas Electron Multiplier technology to retain the performance in terms of particle identification via the measurement of the specific energy loss by ionization d$E$/d$x$. A full-size readout chamber prototype was assembled in 2014 featuring a stack of four GEM foils as an amplification stage. The performance of the prototype was evaluated in a test beam campaign at the CERN PS. The d$E$/d$x$ resolution complies with both the performance of the currently operated MWPC-based readout chambers and the challenging requirements of the ALICE TPC upgrade program. Detailed simulations of the readout system are able to reproduce the data.
△ Less
Submitted 17 June, 2018; v1 submitted 8 May, 2018;
originally announced May 2018.
-
The novel photon detectors based on MPGD technologies for the upgrade of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
R. Birsa,
F. Bradamante,
A. Bressan,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
B. Gobbo,
M. Gregori,
G. Hamar,
S. Levorato,
A. Maggiora,
A. Martin,
G. Menon,
J. Novy,
D. Panzieri
, et al. (10 additional authors not shown)
Abstract:
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination…
▽ More
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination of two THGEMs and a Micromegas stage; the first THGEM, coated with a CsI layer, acts as a reflective photocathode. The signals are extracted from the anode pads by capacitive coupling and read-out by analog front-end electronics based on the APV25 chip. The new COMPASS RICH-1 photon detectors are described in detail: the detector design, the engineering aspects, the mass production, and the quality assessment are discussed. The assembly of the MPGD components and the installation of the new detectors are illustrated together with the main aspects of the commissioning. Preliminary indication of performance results are also presented.
△ Less
Submitted 16 April, 2018;
originally announced April 2018.
-
The high voltage system for the novel MPGD-based photon detectors of COMPASS RICH-1
Authors:
J. Agarwala,
R. Birsa,
F. Bradamante,
A. Bressan,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
B. Gobbo,
M. Gregori,
G. Hamar,
S. Levorato,
A. Martin,
G. Menon,
F. Tessarotto,
Y. Zhao
Abstract:
The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk resistive MICROMEGAS. Concerning biasing voltage, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MICROMEGAS anode is segmented in pads individually biased at…
▽ More
The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk resistive MICROMEGAS. Concerning biasing voltage, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MICROMEGAS anode is segmented in pads individually biased at positive voltage, while the micromesh is grounded. In total, there are ten different electrode types and more than 20000 electrodes supplied by more than 100 HV channels. Commercial power supply units are used. The original elements of the power supply system are the architecture of the voltage distribution net, the compensation, by voltage adjustment, of the effects of pressure and temperature variation affecting the detector gain and a sophisticated control software, which allows to protect the detectors against errors by the operator, to monitor and log voltages and current at 1 Hz rate and to automatically react to detector misbehaviors. The HV system and its performance are described in detail as well as the electrical stability of the detector during the operation at COMPASS.
△ Less
Submitted 5 March, 2018;
originally announced March 2018.
-
Status of COMPASS RICH-1 Upgrade with MPGD-based Photon Detectors
Authors:
M. Alexeev,
R Birsa,
F. Bradamante,
A. Bressan,
M. Chiosso,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fishcher,
B. Gobbo,
M. Gregori,
G. Hamar,
F. Herrmann,
K. Koenigsmann,
S. Levorato,
A. Maggiora,
N. Makke,
A. Martin,
G. Menon,
J. Novy,
D. Panzieri,
F. A. Pereira
, et al. (10 additional authors not shown)
Abstract:
A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are describe…
▽ More
A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are described in detail.
△ Less
Submitted 25 October, 2017;
originally announced October 2017.
-
Novel MPGD based Detectors of Single Photons in COMPASS RICH-1
Authors:
J. Agarwala M. Alexeev,
C. D. R. Azevedo,
R. Birsa,
F. Bradamante,
A. Bressan,
M. Buchele,
C. Chatterjee,
M. Chiosso,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
H. Fischer,
B. Gobbo,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Maggiora,
N. Makke,
A. Martin,
G. Menon,
J. Novy
, et al. (12 additional authors not shown)
Abstract:
COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly dev…
▽ More
COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly developed MPGD based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a MicroMegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during 2016 COMPASS data taking and stably operated during 2017 run. In this paper all aspects of the novel photon detectors for COMPASS RICH-1 are discussed.
△ Less
Submitted 24 October, 2017;
originally announced October 2017.
-
First report of long term measurements of the {MGGL} laboratory in the {M}átra mountain range
Authors:
G. G. Barnaföldi,
T. Bulik,
M. Cieslar,
E. Dávid,
M. Dobróka,
E. Fenyvesi,
D. Gondek-Rosinska,
Z. Gráczer,
G. Hamar,
G. Huba,
Á. Kis,
R. Kovács,
I. Lemperger,
P. Lévai,
J. Molnár,
D. Nagy,
A. Novák,
L. Oláh,
P. Pázmándi,
D. Piri,
L. Somlai,
T. Starecki,
M. Suchenek,
G. Surányi,
S. Szalai
, et al. (6 additional authors not shown)
Abstract:
Matra Gravitational and Geophysical Laboratory (MGGL) has been established near Gyöngyösoroszi, Hungary in 2015, in the cavern system of an unused ore mine. The Laboratory is located at 88~m below the surface, with the aim to measure and analyse the advantages of the underground installation of third generation gravitational wave detectors. Specialized instruments have been installed to measure se…
▽ More
Matra Gravitational and Geophysical Laboratory (MGGL) has been established near Gyöngyösoroszi, Hungary in 2015, in the cavern system of an unused ore mine. The Laboratory is located at 88~m below the surface, with the aim to measure and analyse the advantages of the underground installation of third generation gravitational wave detectors. Specialized instruments have been installed to measure seismic, infrasound, electromagnetic noise, and the variation of the cosmic muon flux. In the preliminary (RUN-0) test period, March-August 2016, data collection has been accomplished. In this paper we describe the research potential of the MGGL, list the installed equipments and summarize the experimental results of RUN-0. Here we report RUN-0 data, that prepares systematic and synchronized data collection of the next run period.
△ Less
Submitted 3 May, 2017; v1 submitted 24 October, 2016;
originally announced October 2016.
-
High efficiency gaseous tracking detector for cosmic muon radiography
Authors:
Dezső Varga,
Gábor Nyitrai,
Gergő Hamar,
László Oláh
Abstract:
A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized for the application of muon radiography. The main features are high (>99.5%) and uniform detection efficiency, 9 mm FWHM position resolution, filling gas consu…
▽ More
A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized for the application of muon radiography. The main features are high (>99.5%) and uniform detection efficiency, 9 mm FWHM position resolution, filling gas consumption below 2 liters per hour for the non toxic, non flammable argon and carbon dioxide mixture. These parameters, along with the simplicity of the construction and the tolerance for mechanical effects, make the detectors to be a viable option for a large area muography observation system.
△ Less
Submitted 28 August, 2016; v1 submitted 28 July, 2016;
originally announced July 2016.
-
Single electron multiplication distribution in GEM avalanches
Authors:
Andras Laszlo,
Gergo Hamar,
Gabor Kiss,
Dezso Varga
Abstract:
In this paper, measurement results and experimental methodology are presented on the determination of multiplication distributions of avalanches initiated by single electron in GEM foils. The measurement relies on the amplification of photoelectrons by the GEM under study, which is subsequently amplified in an MWPC for signal enhancement and readout. The intrinsic detector resolution, namely the s…
▽ More
In this paper, measurement results and experimental methodology are presented on the determination of multiplication distributions of avalanches initiated by single electron in GEM foils. The measurement relies on the amplification of photoelectrons by the GEM under study, which is subsequently amplified in an MWPC for signal enhancement and readout. The intrinsic detector resolution, namely the sigma-over-mean ratio of the multiplication. distribution is also elaborated. Small gain dependence of the shape of the avalanche response distribution is observed in the range of net effective gain of 15 to 100. The distribution has an exponentially decaying tail at large amplitudes. At small amplitudes, the applied working gas is seen to have a well visible effect on the shape of the multiplication distribution. Equivalently, the working gas has an influence on the intrinsic detector resolution of GEMs via suppression of the low amplitude responses. A sigma-over-mean ratio of 0.75 was reached using a neon based mixture, whereas other gases provided an intrinsic detector resolution closer to 1, meaning a multiplication distribution closer to the low-field limit exponential case.
△ Less
Submitted 25 October, 2016; v1 submitted 23 May, 2016;
originally announced May 2016.
-
Cosmic Muon Detector Using Proportional Chambers
Authors:
Dezső Varga,
Zoltán Gál,
Gergő Hamar,
Janka Sára Molnár,
Éva Oláh,
Péter Pázmándi
Abstract:
A set of classical multi-wire proportional chambers were designed and constructed with the main purpose of efficient cosmic muon detection. These detectors are relatively simple to construct, and at the same time are low cost, making them ideal for educational purposes. The detector layers have efficiencies above 99% for minimum ionizing cosmic muons, and their position resolution is about 1 cm, t…
▽ More
A set of classical multi-wire proportional chambers were designed and constructed with the main purpose of efficient cosmic muon detection. These detectors are relatively simple to construct, and at the same time are low cost, making them ideal for educational purposes. The detector layers have efficiencies above 99% for minimum ionizing cosmic muons, and their position resolution is about 1 cm, that is, particle trajectories are clearly observable. Visualization of straight tracks is possible using an LED array, with the discriminated and latched signal driving the display. Due to the exceptional operating stability of the chambers, the design can also be used for cosmic muon telescopes.
△ Less
Submitted 28 July, 2015;
originally announced July 2015.
-
Pre-Excitation Studies for Rubidium-Plasma Generation
Authors:
M. Aladi,
J. S. Bakos,
I. F. Barna,
A. Czitrovszky,
G. P. Djotyan,
P. Dombi,
D. Dzsotjan,
I. B. Földes,
G. Hamar,
P. N. Ignácz,
M. Kedves,
A. Kerekes,
P. Lévai,
I. Márton,
A. Nagy,
D. Oszetzky,
M. A. Pócsai,
P. Rácz,
B. Ráczkevi,
J. Szigeti,
Zs. Sörlei,
R. Szipőcs,
D. Varga,
K. Varga-Umbrich,
S. Varró
, et al. (2 additional authors not shown)
Abstract:
The key element in the Proton-Driven-Plasma-Wake-Field-Accelerator (AWAKE) project is the generation of highly uniform plasma from Rubidium vapor. The standard way to achieve full ionization is to use high power laser which can assure the over-barrier-ionization (OBI) along the 10 meters long active region. The Wigner-team in Budapest is investigating an alternative way of uniform plasma generatio…
▽ More
The key element in the Proton-Driven-Plasma-Wake-Field-Accelerator (AWAKE) project is the generation of highly uniform plasma from Rubidium vapor. The standard way to achieve full ionization is to use high power laser which can assure the over-barrier-ionization (OBI) along the 10 meters long active region. The Wigner-team in Budapest is investigating an alternative way of uniform plasma generation. The proposed Resonance Enhanced Multi Photon Ionization (REMPI) scheme probably can be realized by much less laser power. In the following the resonant pre-excitations of the Rb atoms are investigated, theoretically and the status report about the preparatory work on the experiment are presented.
△ Less
Submitted 10 September, 2013;
originally announced September 2013.