-
Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. Alonso-González,
D. W. P. Amaral,
J. Anczarski,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
C. Bathurst,
R. Bhattacharyya,
A. J. Biffl,
P. L. Brink,
M. Buchanan,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
J. -H. Chen
, et al. (115 additional authors not shown)
Abstract:
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon k…
▽ More
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Low-dose, high-resolution CT of infant-sized lungs via propagation-based phase contrast
Authors:
James A. Pollock,
Kaye Morgan,
Linda C. P. Croton,
Emily J. Pryor,
Kelly J. Crossley,
Christopher J. Hall,
Daniel Hausermann,
Anton Maksimenko,
Stuart B. Hooper,
Marcus J. Kitchen
Abstract:
Many lung diseases and abnormalities require detailed visualisation of the lungs for accurate diagnosis and treatment. High-resolution computed tomography (CT) is the gold-standard technique for non-invasive lung disease detection, but it presents a risk to the patient through the relatively high ionising radiation dose required. Utilising the X-ray phase information may allow improvements in imag…
▽ More
Many lung diseases and abnormalities require detailed visualisation of the lungs for accurate diagnosis and treatment. High-resolution computed tomography (CT) is the gold-standard technique for non-invasive lung disease detection, but it presents a risk to the patient through the relatively high ionising radiation dose required. Utilising the X-ray phase information may allow improvements in image resolution at equal or lower radiation levels than current clinical imaging. Propagation-based phase-contrast imaging requires minimal adaption of existing medical systems, and is well suited to lung imaging due to the strong phase gradients introduced by the lung-air material interface. Herein, propagation-based phase contrast CT is demonstrated for large animals, namely lambs, as a model for paediatric patients, using monochromatic radiation and a photon-counting detector at the Imaging and Medical Beamline of the Australian Synchrotron. Image quality, normalised against radiation dose, was optimised as a function of the beam energy and propagation distance, with the optimal conditions used to test the available image quality at very low radiation dose. Noise-limited spatial resolution was measured using Fourier ring correlation, and dosimetry was performed through Monte Carlo simulation calibrated against air kerma. The resulting CT images demonstrate superior resolution to existing high-resolution CT systems, pushing dose to the quantum limit to comply with current Australian guidelines for infant chest CT exposure (<2.5 mSv effective dose). Constituent raw projections are shown to have significant proportions of pixels with zero photon counts that would create severe information loss in conventional CT, which was prevented through phase retrieval.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Tracking radiation damage of Euclid VIS detectors after 1 year in space
Authors:
Jesper Skottfelt,
Matt Wander,
Mark Cropper,
Ben Dryer,
David J. Hall,
Richard Hayes,
Bradley Kelman,
Tom Kitching,
Ralf Kohley,
David Lagattuta,
Zoe Lee-Payne,
Patricia Liebing,
Richard Massey,
Henry Joy McCracken,
Reiko Nakajima,
James Nightingale
Abstract:
Due to the space radiation environment at L2, ESA's Euclid mission will be subject to a large amount of highly energetic particles over its lifetime. These particles can cause damage to the detectors by creating defects in the silicon lattice. These defects degrade the returned image in several ways, one example being a degradation of the Charge Transfer Efficiency, which appears as readout trails…
▽ More
Due to the space radiation environment at L2, ESA's Euclid mission will be subject to a large amount of highly energetic particles over its lifetime. These particles can cause damage to the detectors by creating defects in the silicon lattice. These defects degrade the returned image in several ways, one example being a degradation of the Charge Transfer Efficiency, which appears as readout trails in the image data. This can be problematic for the Euclid VIS instrument, which aims to measure the shapes of galaxies to a very high degree of accuracy. Using a special clocking technique called trap pum**, the single defects in the CCDs can be detected and characterised. Being the first instrument in space with this capability, it will provide novel insights into the creation and evolution of radiation-induced defects and give input to the radiation damage correction of the scientific data. We present the status of the radiation damage of the Euclid VIS CCDs and how it has evolved over the first year in space.
△ Less
Submitted 1 July, 2024;
originally announced July 2024.
-
Bell vs Bell: a ding-dong battle over quantum incompleteness
Authors:
Michael J. W. Hall
Abstract:
Does determinism (or even the incompleteness of quantum mechanics) follow from locality and perfect correlations? In a 1964 paper John Bell gave the first demonstration that quantum mechanics is incompatible with local hidden variables. Since then a vigorous debate has rung out over whether he relied on an assumption of determinism or instead, as he later claimed in a 1981 paper, derived determini…
▽ More
Does determinism (or even the incompleteness of quantum mechanics) follow from locality and perfect correlations? In a 1964 paper John Bell gave the first demonstration that quantum mechanics is incompatible with local hidden variables. Since then a vigorous debate has rung out over whether he relied on an assumption of determinism or instead, as he later claimed in a 1981 paper, derived determinism from assumptions of locality and perfect correlation. This paper aims to bring clarity to the debate via simple examples and rigorous results. It is first recalled, via quantum and classical counterexamples, that the weakest statistical form of locality consistent with Bell's 1964 paper (parameter independence) is insufficient for the derivation of determinism. Attention is then turned to critically assess Bell's appealing to the Einstein-Rosen-Podolsky incompleteness argument to support his claim. It is shown this argument is itself incomplete, via counterexamples that expose two logical gaps. However, closing these gaps via a strong ``counterfactual'' reality criterion enables a rigorous derivation of each of quantum incompleteness, determinism and parameter independence, and in this sense justifies Bell's claim. Consequences for quantum interpretations are briefly discussed.
△ Less
Submitted 27 June, 2024;
originally announced June 2024.
-
Batch VUV4 Characterization for the SBC-LAr10 scintillating bubble chamber
Authors:
H. Hawley-Herrera,
E. Alfonso-Pita,
E. Behnke,
M. Bressler,
B. Broerman,
K. Clark,
J. Corbett,
C. E. Dahl,
K. Dering,
A. de St. Croix,
D. Durnford,
P. Giampa,
J. Hall,
O. Harris,
N. Lamb,
M. Laurin,
I. Levine,
W. H. Lippincott,
X. Liu,
N. Moss,
R. Neilson,
M. -C. Piro,
D. Pyda,
Z. Sheng,
G. Sweeney
, et al. (6 additional authors not shown)
Abstract:
The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10~kg of liquid argon. The VUV4 SiPMs, or Quads, underwent a characterization at two temperatures which measured the breakdown voltage ($V_{\text{BD}}$), the SiPM gain ($g_{\text{SiPM}}$), the rate of change of $g_{\text{SiPM}}$ with re…
▽ More
The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10~kg of liquid argon. The VUV4 SiPMs, or Quads, underwent a characterization at two temperatures which measured the breakdown voltage ($V_{\text{BD}}$), the SiPM gain ($g_{\text{SiPM}}$), the rate of change of $g_{\text{SiPM}}$ with respect to voltage ($m$), the dark count rate (DCR), and the probability of a correlated avalanche (P$_{\text{CA}}$) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to $233.15\pm0.2$~K and $255.15\pm0.2$~K with average stability of $\pm20$~mK. A mostly assumption-free analysis was derived to estimate $V_{\text{BD}}$ to tens of mV precision and DCR close to Poissonian error. The temperature dependence of $V_{\text{BD}}$ was found to be $56\pm2$~mV~K$^{-1}$, and $m$ on average across all Quads was found to be $(459\pm3(\rm{stat.})\pm23(\rm{sys.}))\times 10^{3}~e^-$~PE$^{-1}$~V$^{-1}$. The average DCR temperature coefficient was estimated to be $0.099\pm0.008$~K$^{-1}$ corresponding to a reduction factor of 7 for every 20~K drop in temperature. The average temperature dependence of P$_{\text{CA}}$ was estimated to be $4000\pm1000$~ppm~K$^{-1}$. P$_{\text{CA}}$ estimated from the average across all SiPMs is a better estimator than the P$_{\text{CA}}$ calculated from individual SiPMs, whereas all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
Synthetic FM triplet for AM-free precision laser stabilization and spectroscopy
Authors:
Dhruv Kedar,
Zhibin Yao,
Ivan Ryger,
John L. Hall,
Jun Ye
Abstract:
The Pound-Drever-Hall (PDH) cavity-locking scheme has found prevalent uses in precision optical interferometry and laser frequency stabilization. A form of frequency modulation spectroscopy, PDH enjoys superior signal-to-noise recovery, large acquisition dynamic range, wide servo bandwidth, and robust rejection of spurious effects. However, residual amplitude modulation at the signal frequency, wh…
▽ More
The Pound-Drever-Hall (PDH) cavity-locking scheme has found prevalent uses in precision optical interferometry and laser frequency stabilization. A form of frequency modulation spectroscopy, PDH enjoys superior signal-to-noise recovery, large acquisition dynamic range, wide servo bandwidth, and robust rejection of spurious effects. However, residual amplitude modulation at the signal frequency, while significantly suppressed, still presents an important concern for further advancing the state-of-the-art performances. Here we present a simplified and improved scheme for PDH using an acousto-optic modulator to generate digital phase reference sidebands instead of the traditionally used electro-optic modulator approach. We demonstrate four key advantages: (1) the carrier and two modulation tones are individually synthesized and easily reconfigured, (2) robust and orthogonal control of the modulated optical field is applied directly to the amplitude and phase quadratures, (3) modulation synthesis, demodulation, and feedback are implemented in a self-contained and easily reproducible electronic unit, and (4) superior active and passive control of residual amplitude modulation is achieved, especially when the carrier power is vanishingly low. These distinct merits stimulate new ideas on how we optimally enact PDH for a wide range of applications.
△ Less
Submitted 23 November, 2023;
originally announced November 2023.
-
CUTE: A Cryogenic Underground TEst Facility at SNOLAB
Authors:
Philippe Camus,
Jonathan Corbett,
Sean Crawford,
Koby Dering,
Eleanor Fascione,
Gilles Gerbier,
Richard Germond,
Muad Ghaith,
Jeter Hall,
Ziqing Hong,
Andrew Kubik,
Adam Mayer,
Serge Nagorny,
Payam Pakarha,
Wolfgang Rau,
Silvia Scorza,
Ryan Underwood
Abstract:
Low-temperature cryogenics open the door for a range of interesting technologies based on features like superconductivity and superfluidity, low-temperature phase transitions or the low heat capacity of non-metals in the milli-Kelvin range. Devices based on these technologies are often sensitive to small energy depositions as can be caused by environmental radiation. The Cryogenic Underground TEst…
▽ More
Low-temperature cryogenics open the door for a range of interesting technologies based on features like superconductivity and superfluidity, low-temperature phase transitions or the low heat capacity of non-metals in the milli-Kelvin range. Devices based on these technologies are often sensitive to small energy depositions as can be caused by environmental radiation. The Cryogenic Underground TEst facility (CUTE) at SNOLAB is a platform for testing and operating cryogenic devices in an environment with low levels of background. The large experimental chamber ($\mathcal{O}$(10) L) reaches a base temperature of $\sim$12 mK; it can hold a payload of up to $\sim$20 kg and provides a radiogenic background event rate as low as a few events/kg/keV/day in the energy range below about 100 keV, as well as a negligible muon rate ($\mathcal{O}$(1)/month). CUTE was designed and built in the context of the Super Cryogenic Dark Matter Search experiment (SuperCDMS) which uses cryogenic detectors to search for interactions of dark matter particles with ordinary matter. The facility has been used to test SuperCDMS detectors since its commissioning in 2019. In 2021, it was handed over to SNOLAB to become a SNOLAB user facility after the completion of the testing of detectors for SuperCDMS. The facility will be available for projects that benefit from these special conditions, based on proposals assessed for their scientific and technological merits. This article describes the main design features and operating parameters of CUTE.
△ Less
Submitted 30 January, 2024; v1 submitted 11 October, 2023;
originally announced October 2023.
-
Simulation of optoelectronic oscillator injection locking, pulling and spiking phenomena
Authors:
A. Banerjee,
T. J. Hall
Abstract:
Complex envelope and reduced phase simulation models describing the dynamical behavior of an optoelectronic oscillator (OEO) under injection by an external source are described. The models are built on the foundations of a previously reported delay integral differential equation (DDE) theory of injection locking of time delay oscillators (TDO) such as the OEO. The DDE formulation is particularly a…
▽ More
Complex envelope and reduced phase simulation models describing the dynamical behavior of an optoelectronic oscillator (OEO) under injection by an external source are described. The models are built on the foundations of a previously reported delay integral differential equation (DDE) theory of injection locking of time delay oscillators (TDO) such as the OEO. The DDE formulation is particularly amenable to high precision simulation using the Simulink block diagram environment. The correspondence between the blocks and the oscillator components offers intuition and considerable freedom to explore different circuit architectures and design variations with minimal coding effort. The simulations facilitate the study of the profound effect the multimode nature of a TDO has on its dynamical behavior. The reduced phase models that make use of the Leeson approximation are generally successful in reproducing the results of complex envelope models for established oscillations except for spiking phenomena for which the Leeson approximation fails. Simulation results demonstrating phenomena not captured by classical injection theory are presented, including multimode oscillation, the appearance of sidemodes in the RF and phase noise spectrum, and persistent spike trains redolent of recent experimental observations of 2pi phase pulse trains in a broadband OEO under injection.
△ Less
Submitted 24 September, 2023;
originally announced September 2023.
-
Evaluation of SNOLAB background mitigation procedures through the use of an ICP-MS based dust monitoring methodology
Authors:
M. L. di Vacri,
S. Scorza,
A. French,
N. D. Rocco,
T. D. Schlieder,
I. J. Arnquist,
E. W. Hoppe,
J. Hall
Abstract:
Dust particulate fallout on materials in use for rare-event searches is a concerning source of radioactive backgrounds due to the presence of naturally occurring radionuclides K-40, Th-232, U-238, and their progeny in dust. Much effort is dedicated to inform radioactive backgrounds from dust and evaluate the efficacy of mitigation procedures. A great portion of such effort relies on fallout models…
▽ More
Dust particulate fallout on materials in use for rare-event searches is a concerning source of radioactive backgrounds due to the presence of naturally occurring radionuclides K-40, Th-232, U-238, and their progeny in dust. Much effort is dedicated to inform radioactive backgrounds from dust and evaluate the efficacy of mitigation procedures. A great portion of such effort relies on fallout models and assumed dust composition. In this work, an ICP-MS based methodology was employed for a direct determination of fallout rates of radionuclides and stable isotopes of interest from dust particulate at the SNOLAB facility. Hosted in an active mine, the SNOLAB underground laboratory strives to maintain experimental areas at class 2000 cleanroom level. This work validates the mitigation procedures in place at SNOLAB, and informs dust backgrounds during laboratory activities. Fallout rates of major constituent of the local rock were measured two to three orders of magnitude lower in the clean experimental areas compared to non-clean transition areas from the mine to the laboratory. A ca. two order of magnitude increase in stable Pb fallout rate was determined in an experimental area during activities involving handling of Pb bricks. Increased K-40, Th-232, and U-238 fallout rates were measured in clean experimental areas during activities generating particulate.
△ Less
Submitted 23 August, 2023;
originally announced August 2023.
-
Environmental sustainability in basic research: a perspective from HECAP+
Authors:
Sustainable HECAP+ Initiative,
:,
Shankha Banerjee,
Thomas Y. Chen,
Claire David,
Michael Düren,
Harold Erbin,
Jacopo Ghiglieri,
Mandeep S. S. Gill,
L Glaser,
Christian Gütschow,
Jack Joseph Hall,
Johannes Hampp,
Patrick Koppenburg,
Matthias Koschnitzke,
Kristin Lohwasser,
Rakhi Mahbubani,
Viraf Mehta,
Peter Millington,
Ayan Paul,
Frauke Poblotzki,
Karolos Potamianos,
Nikolina Šarčević,
Rajeev Singh,
Hannah Wakeling
, et al. (3 additional authors not shown)
Abstract:
The climate crisis and the degradation of the world's ecosystems require humanity to take immediate action. The international scientific community has a responsibility to limit the negative environmental impacts of basic research. The HECAP+ communities (High Energy Physics, Cosmology, Astroparticle Physics, and Hadron and Nuclear Physics) make use of common and similar experimental infrastructure…
▽ More
The climate crisis and the degradation of the world's ecosystems require humanity to take immediate action. The international scientific community has a responsibility to limit the negative environmental impacts of basic research. The HECAP+ communities (High Energy Physics, Cosmology, Astroparticle Physics, and Hadron and Nuclear Physics) make use of common and similar experimental infrastructure, such as accelerators and observatories, and rely similarly on the processing of big data. Our communities therefore face similar challenges to improving the sustainability of our research. This document aims to reflect on the environmental impacts of our work practices and research infrastructure, to highlight best practice, to make recommendations for positive changes, and to identify the opportunities and challenges that such changes present for wider aspects of social responsibility.
△ Less
Submitted 18 August, 2023; v1 submitted 5 June, 2023;
originally announced June 2023.
-
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
P. An,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
P. S. Barbeau,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (115 additional authors not shown)
Abstract:
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for furthe…
▽ More
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.
△ Less
Submitted 3 March, 2023;
originally announced March 2023.
-
Optimizing the sensitivity of high repetition rate broadband transient optical spectroscopy with modified shot-to-shot detection
Authors:
Siedah J. Hall,
Peter J. Budden,
Anne Zats,
Matthew Y. Sfeir
Abstract:
A major limitation of transient optical spectroscopy is that relatively high laser fluences are required to enable broadband, multichannel detection with acceptable signal-to-noise levels. Under typical experimental conditions, many condensed phase and nanoscale materials exhibit fluence-dependent dynamics, including higher-order effects such as carrier-carrier annihilation. With the proliferation…
▽ More
A major limitation of transient optical spectroscopy is that relatively high laser fluences are required to enable broadband, multichannel detection with acceptable signal-to-noise levels. Under typical experimental conditions, many condensed phase and nanoscale materials exhibit fluence-dependent dynamics, including higher-order effects such as carrier-carrier annihilation. With the proliferation of commercial laser systems, offering both high repetition rates and high pulse energies, has come new opportunities for high sensitivity pump-probe measurements at low pump fluences. However, experimental considerations needed to fully leverage the statistical advantage of these laser systems has not been fully described. Here we demonstrate a high repetition rate, broadband transient spectrometer capable of multichannel shot-to-shot detection at 90 kHz. Importantly, we find that several high-speed cameras exhibit a time-domain fixed pattern noise resulting from interleaved analog-to-digital converters that is particularly detrimental to the conventional "ON/OFF" modulation scheme used in pump-probe spectroscopy. Using a modified modulation and data processing scheme, we achieve a noise level of $10^{-5}$ OD for an integration time of four seconds, an order of magnitude lower than for commercial 1 kHz transient spectrometers. We leverage the high sensitivity of this system to measure the differential transmission of monolayer graphene at low pump fluence. We show that signals on the order of $10^{-6}$ OD can be measured, enabling a new data acquisition regime for low-dimensional materials.
△ Less
Submitted 28 March, 2023; v1 submitted 20 January, 2023;
originally announced January 2023.
-
Snowmass 2021 Underground Facilities and Infrastructure Overview Topical Report
Authors:
L. Baudis,
J. Hall,
K. T. Lesko,
J. L. Orrell
Abstract:
The Underground Frontier (UF) was charged with assessing the anticipated needs and available space for well shielded underground space to conduct scientific research. The Frontier sought to understand the existing space, space that would become available in the coming decade, and potential for creating additional space to host these efforts. To this end UF created a survey which was sent to existi…
▽ More
The Underground Frontier (UF) was charged with assessing the anticipated needs and available space for well shielded underground space to conduct scientific research. The Frontier sought to understand the existing space, space that would become available in the coming decade, and potential for creating additional space to host these efforts. To this end UF created a survey which was sent to existing underground laboratories. This assessment was necessary for UF to develop a bold plan to foster and empower broad reaching underground research, maximize cost savings and synergistic research opportunities, and advance the HEP research program requiring underground space for the next two decades.
△ Less
Submitted 14 December, 2022;
originally announced December 2022.
-
Snowmass 2021 Underground Facilities & Infrastructure Frontier Report
Authors:
Laura Baudis,
Jeter Hall,
Kevin T. Lesko,
John L. Orrell
Abstract:
The decade since Snowmass 2013 has seen extraordinary progress of high energy physics research performed--or planned for--at underground facilities. Drs. T. Kajita and A.B. McDonald were awarded the 2015 Nobel Prize in Physics for the discovery of neutrino oscillation, which show that neutrinos have mass. The U.S. has embarked on the development of the world-class LBNF/DUNE science program to inve…
▽ More
The decade since Snowmass 2013 has seen extraordinary progress of high energy physics research performed--or planned for--at underground facilities. Drs. T. Kajita and A.B. McDonald were awarded the 2015 Nobel Prize in Physics for the discovery of neutrino oscillation, which show that neutrinos have mass. The U.S. has embarked on the development of the world-class LBNF/DUNE science program to investigate neutrino properties. The Generation 2 dark matter program is advancing to full data collection in the coming 5 years, a Dark Matter New Initiatives program has begun, and the U.S. dark matter community is looking toward a Generation 3 program of large-scale dark matter direct detection searches. The Sanford Underground Research Facility has become a focal point for U.S. underground facilities and infrastructure investment. The status since the 2013 Snowmass process as well as the outcome from the 2014 P5 program of recommendations is reviewed. These are then evaluated based on the activities and discussions of the Snowmass 2021 process resulting in conclusions looking forward to the coming decade of high energy physics research performed in underground facilities.
△ Less
Submitted 24 November, 2022;
originally announced November 2022.
-
Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
Authors:
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. Ch. Avetisov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
E. Berzin,
A. Bondar,
W. M. Bonivento,
E. Borisova,
B. Bottino
, et al. (274 additional authors not shown)
Abstract:
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These stu…
▽ More
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino floor for GeV-scale masses and significant sensitivity down to 10 MeV/c$^2$ considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector's sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies.
△ Less
Submitted 20 June, 2023; v1 submitted 2 September, 2022;
originally announced September 2022.
-
Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$ν$NS Detection
Authors:
E. Alfonso-Pita,
M. Baker,
E. Behnke,
A. Brandon,
M. Bressler,
B. Broerman,
K. Clark,
R. Coppejans,
J. Corbett,
C. Cripe,
M. Crisler,
C. E. Dahl,
K. Dering,
A. de St. Croix,
D. Durnford,
K. Foy,
P. Giampa,
J. Gresl,
J. Hall,
O. Harris,
H. Hawley-Herrera,
C. M. Jackson,
M. Khatri,
Y. Ko,
N. Lamb
, et al. (20 additional authors not shown)
Abstract:
The Scintillating Bubble Chamber (SBC) Collaboration is develo** liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This dev…
▽ More
The Scintillating Bubble Chamber (SBC) Collaboration is develo** liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This device will calibrate the background discrimination power and sensitivity of superheated argon to nuclear recoils at energies down to 100 eV. A second functionally-identical detector with a focus on radiopure construction is being built for SBC's first dark matter search at SNOLAB. The projected spin-independent sensitivity of this search is approximately $10^{-43}$ cm$^2$ at 1 GeV$/c^2$ dark matter particle mass. The scalability and background discrimination power of the liquid-noble bubble chamber make this technique a compelling candidate for future dark matter searches to the solar neutrino fog at 1 GeV$/c^2$ particle mass (requiring a $\sim$ton-year exposure with non-neutrino backgrounds sub-dominant to the solar CE$ν$NS signal) and for high-statistics CE$ν$NS studies at nuclear reactors.
△ Less
Submitted 29 September, 2022; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Simple precession calculation for Mercury: a linearization approach
Authors:
Michael J. W. Hall
Abstract:
The additional precession of Mercury due to general relativity can be calculated by a method that is no more difficult than solving for the Newtonian orbit. The method relies on linearizing the relativistic orbit equation, is simpler than standard textbook methods, and is closely related to Newton's theorem on revolving orbits. The main result is accurate to all orders in $\tfrac{1}{c}$ for near-c…
▽ More
The additional precession of Mercury due to general relativity can be calculated by a method that is no more difficult than solving for the Newtonian orbit. The method relies on linearizing the relativistic orbit equation, is simpler than standard textbook methods, and is closely related to Newton's theorem on revolving orbits. The main result is accurate to all orders in $\tfrac{1}{c}$ for near-circular orbits.
△ Less
Submitted 23 June, 2022;
originally announced June 2022.
-
The level-1 trigger for the SuperCDMS experiment at SNOLAB
Authors:
Jonathan S. Wilson,
Hanno Meyer zu Theenhausen,
Belina von Krosigk,
Elham Azadbakht,
Ray Bunker,
Jeter Hall,
Sten Hansen,
Bruce Hines,
Ben Loer,
Jamieson T. Olsen,
Scott M. Oser,
Richard Partridge,
Matthew Pyle,
Joel Sander,
Bruno Serfass,
David Toback,
Samuel L. Watkins,
Xuji Zhao
Abstract:
The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to O(1 eV). This imposes requirements on the resolution, signal efficiency, and noise rejection of the trigger system. To accomplish this, the SuperCDMS level-1 trigger system is implemented in an FPGA on a custom PCB. A time-domain optimal filter algorithm realized as a finite impulse response filte…
▽ More
The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to O(1 eV). This imposes requirements on the resolution, signal efficiency, and noise rejection of the trigger system. To accomplish this, the SuperCDMS level-1 trigger system is implemented in an FPGA on a custom PCB. A time-domain optimal filter algorithm realized as a finite impulse response filter provides a baseline resolution of 0.38 times the standard deviation of the noise, $σ_n$, and a 99.9% trigger efficiency for signal amplitudes of 1.1 $σ_n$ in typical noise conditions. Embedded in a modular architecture, flexible trigger logic enables reliable triggering and vetoing in a dead-time-free manner for a variety of purposes and run conditions. The trigger architecture and performance are detailed in this article.
△ Less
Submitted 23 May, 2022; v1 submitted 27 April, 2022;
originally announced April 2022.
-
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (104 additional authors not shown)
Abstract:
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS…
▽ More
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.
△ Less
Submitted 11 October, 2022; v1 submitted 17 April, 2022;
originally announced April 2022.
-
Minimum-Mass Limits for Streamlined Venus Atmospheric Probes
Authors:
Jacob S. Izraelevitz,
Jeffery L. Hall
Abstract:
Small, expendable drop probes are an attractive method for making measurements in the lower atmosphere of Venus, \,augmenting the capabilities of orbiters or aerial platforms that must remain in the benign temperature region above 50 km altitude. However, probe miniaturization is impeded by the need to provide thermal and pressure protection for conventional payloads. This paper determines the min…
▽ More
Small, expendable drop probes are an attractive method for making measurements in the lower atmosphere of Venus, \,augmenting the capabilities of orbiters or aerial platforms that must remain in the benign temperature region above 50 km altitude. However, probe miniaturization is impeded by the need to provide thermal and pressure protection for conventional payloads. This paper determines the minimum mass limits for an insulated pressure vessel probe that operates all the way to the Venusian surface. Scaling laws for the probe performance and mass of major system components are explicitly derived using a simple model that captures the relevant physics. Streamlining the probe is found to be a highly effective strategy for lowering the system mass, but it also reduces the time available for data collection and transmission. Tradeoffs, guidelines and design charts are presented for an array of miniaturized probes. Total system masses on the order of 5 kilograms are plausible with streamlined probes if the desired science measurements can be performed faster than a standard Venus descent timeline.
△ Less
Submitted 10 April, 2022;
originally announced April 2022.
-
Incorporating Gradient Similarity for Robust Time Delay Estimation in Ultrasound Elastography
Authors:
Md Ashikuzzaman,
Timothy J. Hall,
Hassan Rivaz
Abstract:
Energy-based ultrasound elastography techniques minimize a regularized cost function consisting of data and continuity terms to obtain local displacement estimates based on the local time-delay estimation (TDE) between radio-frequency (RF) frames. The data term associated with the existing techniques takes only the amplitude similarity into account and hence is not sufficiently robust to the outli…
▽ More
Energy-based ultrasound elastography techniques minimize a regularized cost function consisting of data and continuity terms to obtain local displacement estimates based on the local time-delay estimation (TDE) between radio-frequency (RF) frames. The data term associated with the existing techniques takes only the amplitude similarity into account and hence is not sufficiently robust to the outlier samples present in the RF frames under consideration. This drawback creates noticeable artifacts in the strain image. To resolve this issue, we propose to formulate the data function as a linear combination of the amplitude and gradient similarity constraints. We estimate the adaptive weight concerning each similarity term following an iterative scheme. Finally, we optimize the non-linear cost function in an efficient manner to convert the problem to a sparse system of linear equations which are solved for millions of variables. We call our technique rGLUE: robust data term in GLobal Ultrasound Elastography. rGLUE has been validated using simulation, phantom, in vivo liver, and breast datasets. In all of our experiments, rGLUE substantially outperforms the recent elastography methods both visually and quantitatively. For simulated, phantom, and in vivo datasets, respectively, rGLUE achieves 107%, 18%, and 23% improvements of signal-to-noise ratio (SNR) and 61%, 19%, and 25% improvements of contrast-to-noise ratio (CNR) over GLUE, a recently-published elastography algorithm.
△ Less
Submitted 30 March, 2022;
originally announced March 2022.
-
A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (103 additional authors not shown)
Abstract:
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-ba…
▽ More
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion.
The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.
△ Less
Submitted 1 April, 2023; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Optical Wavelength Meter with Machine Learning Enhanced Precision
Authors:
Gazi Mahamud Hasan,
Mehedi Hasan,
Peng Liu,
Mohammad Rad,
Eric Bernier,
Trevor James Hall
Abstract:
Diverse applications in photonics and microwave engineering require a means of measurement of the instantaneous frequency of a signal. A photonic implementation typically applies an interferometer equipped with three or more output ports to measure the frequency dependent phase shift provided by an optical delay line. The components constituting the interferometer are prone to impairments which re…
▽ More
Diverse applications in photonics and microwave engineering require a means of measurement of the instantaneous frequency of a signal. A photonic implementation typically applies an interferometer equipped with three or more output ports to measure the frequency dependent phase shift provided by an optical delay line. The components constituting the interferometer are prone to impairments which results in erroneous measurements. It is shown that the information to be retrieved is encoded by a three-component vector that lies on a circular cone within a three-dimensional Cartesian object space. The measured data belongs to the image of the object space under a linear map that describes the action of the interferometer. Assisted by a learning algorithm, an inverse map from the image space into the object space is constructed. The inverse map compensates for a variety of impairments while being robust to noise. Simulation results demonstrate that, to the extent the interferometer model captures all significant impairments, a precision limited only by the level of random noise is attainable. A wavelength meter architecture is fabricated on Si3N4 photonic integration platform to prove the method experimentally. Applied to the measured data, greater than an order of magnitude improvement in precision is achieved by the proposed method compared to the conventional method.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (104 additional authors not shown)
Abstract:
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yie…
▽ More
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 keV and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low-energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.
△ Less
Submitted 27 June, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
Injection Locking of Optoelectronic Oscillators with Large Delay
Authors:
Mehedi Hasan,
Abhijit Banerjee,
Trevor James Hall
Abstract:
The optoelectronic oscillator is a delay line oscillator that leverages optical fiber technology to realize the large delay required for low phase noise systems. Spurious sidemodes are an artifact of the delay line oscillator, yet treatments of injection locking of optoelectronic oscillators have relied on the application of classical injection locking theory valid only for single mode oscillators…
▽ More
The optoelectronic oscillator is a delay line oscillator that leverages optical fiber technology to realize the large delay required for low phase noise systems. Spurious sidemodes are an artifact of the delay line oscillator, yet treatments of injection locking of optoelectronic oscillators have relied on the application of classical injection locking theory valid only for single mode oscillators. The large delay contributed by the optical fiber delay line is accounted for by classical theory only in part through the quality factor Q that captures the round-trip group delay in a neighborhood of the oscillation frequency. This paper presents a new formulation of time delay oscillators subject to injection that describes all the essential features of their dynamics and phase noise. The common assumptions of a single mode oscillator and weak injection are removed. This is important to correctly predict the locking range, the suppression of sidemodes and the phase noise spectrum. The findings of the analysis are validated by experimental measurements provided by an optoelectronic oscillator under injection by an external source.
△ Less
Submitted 24 October, 2021;
originally announced October 2021.
-
A full gap above the Fermi level: the charge density wave of monolayer VS2
Authors:
Camiel van Efferen,
Jan Berges,
Joshua Hall,
Erik van Loon,
Stefan Kraus,
Arne Schobert,
Tobias Wekking,
Felix Huttmann,
Eline Plaar,
Nico Rothenbach,
Katharina Ollefs,
Lucas Machado Arruda,
Nick Brookes,
Gunnar Schoenhoff,
Kurt Kummer,
Heiko Wende,
Tim Wehling,
Thomas Michely
Abstract:
In the standard model of charge density wave (CDW) transitions, the displacement along a single phonon mode lowers the total electronic energy by creating a gap at the Fermi level, making the CDW a metal--insulator transition. Here, using scanning tunneling microscopy and spectroscopy and ab initio calculations, we show that VS$_2$ realizes a CDW which stands out of this standard model. There is a…
▽ More
In the standard model of charge density wave (CDW) transitions, the displacement along a single phonon mode lowers the total electronic energy by creating a gap at the Fermi level, making the CDW a metal--insulator transition. Here, using scanning tunneling microscopy and spectroscopy and ab initio calculations, we show that VS$_2$ realizes a CDW which stands out of this standard model. There is a full CDW gap residing in the unoccupied states of monolayer VS$_2$. At the Fermi level, the CDW induces a topological metal-metal (Lifshitz) transition. Non-linear coupling of transverse and longitudinal phonons is essential for the formation of the CDW and the full gap above the Fermi level. Additionally, x-ray magnetic circular dichroism reveals the absence of net magnetization in this phase, pointing to coexisting charge and spin density waves in the ground state.
△ Less
Submitted 8 September, 2021; v1 submitted 4 January, 2021;
originally announced January 2021.
-
Tracking solar wind flows from rapidly varying viewpoints by the Wide-field Imager for Parker Solar Probe
Authors:
A. Nindos,
S. Patsourakos,
A. Vourlidas,
P. C. Liewer,
P. Penteado,
J. R. Hall
Abstract:
Aims: Our goal is to develop methodologies to seamlessly track transient solar wind flows viewed by coronagraphs or heliospheric imagers from rapidly varying viewpoints.
Methods: We constructed maps of intensity versus time and elongation (J-maps) from Parker Solar Probe (PSP) Wide-field Imager (WISPR) observations during the fourth encounter of PSP. From the J-map, we built an intensity on impa…
▽ More
Aims: Our goal is to develop methodologies to seamlessly track transient solar wind flows viewed by coronagraphs or heliospheric imagers from rapidly varying viewpoints.
Methods: We constructed maps of intensity versus time and elongation (J-maps) from Parker Solar Probe (PSP) Wide-field Imager (WISPR) observations during the fourth encounter of PSP. From the J-map, we built an intensity on impact-radius-on-Thomson-surface map (R-map). Finally, we constructed a latitudinal intensity versus time map (Lat-map). Our methodology satisfactorily addresses the challenges associated with the construction of such maps from data taken from rapidly varying viewpoint observations.
Results: Our WISPR J-map exhibits several tracks, corresponding to transient solar wind flows ranging from a coronal mass ejection (CME) down to streamer blobs. The latter occurrence rate is about 4-5 per day, which is similar to the occurrence rate in a J-map made from $\sim1$ AU data obtained with the Heliospheric Imager-1 (HI-1) on board the Solar Terrestrial Relations Observatory Ahead spacecraft (STEREO-A). STEREO-A was radially aligned with PSP during the study period. The WISPR J-map tracks correspond to angular speeds of $2.28 \pm 0.7$$^{\circ}$/hour ($2.49 \pm 0.95$$^{\circ}$/hour), for linear (quadratic) time-elongation fittings, and radial speeds of about 150-300 km s$^{-1}$. The analysis of the Lat-map reveals a bifurcating streamer, which implies that PSP was flying through a slightly folded streamer during perihelion.
Conclusions: We developed a framework to systematically capture and characterize transient solar wind flows from space platforms with rapidly varying vantage points. The methodology can be applied to PSP WISPR observations as well as to upcoming observations from instruments on board the Solar Orbiter mission.
△ Less
Submitted 25 October, 2020;
originally announced October 2020.
-
Does locality plus perfect correlation imply determinism?
Authors:
Michael J. W. Hall
Abstract:
A 1964 paper by John Bell gave the first demonstration that quantum mechanics is incompatible with local hidden variables. There is an ongoing and vigorous debate on whether he relied on an assumption of determinism, or instead, as he later claimed, derived determinism from assumptions of locality and perfect correlation. This paper aims to bring clarity to the debate via simple examples and rigor…
▽ More
A 1964 paper by John Bell gave the first demonstration that quantum mechanics is incompatible with local hidden variables. There is an ongoing and vigorous debate on whether he relied on an assumption of determinism, or instead, as he later claimed, derived determinism from assumptions of locality and perfect correlation. This paper aims to bring clarity to the debate via simple examples and rigorous results. It is shown that the weak form of locality used in Bell's 1964 paper (parameter independence) is insufficient for such a derivation, whereas an independent form called outcome independence is sufficient even when weak locality does not hold. It further follows that outcome independence, by itself, implies that standard quantum mechanics is incomplete. It is also shown that an appeal by Bell to the Einstein-Rosen-Podolsky argument to support his claim fails, via examples that expose logical gaps in this argument. However, replacing the reality criterion underpinning the argument by a stronger criterion enables a rigorous derivation of both weak locality and determinism, as required for Bell's 1964 paper. Consequences for quantum interpretations, locality, and classical common causes are briefly discussed, with reference to an example of local classical indeterminism.
△ Less
Submitted 25 June, 2024; v1 submitted 29 September, 2020;
originally announced September 2020.
-
GINNs: Graph-Informed Neural Networks for Multiscale Physics
Authors:
Eric J. Hall,
Søren Taverniers,
Markos A. Katsoulakis,
Daniel M. Tartakovsky
Abstract:
We introduce the concept of a Graph-Informed Neural Network (GINN), a hybrid approach combining deep learning with probabilistic graphical models (PGMs) that acts as a surrogate for physics-based representations of multiscale and multiphysics systems. GINNs address the twin challenges of removing intrinsic computational bottlenecks in physics-based models and generating large data sets for estimat…
▽ More
We introduce the concept of a Graph-Informed Neural Network (GINN), a hybrid approach combining deep learning with probabilistic graphical models (PGMs) that acts as a surrogate for physics-based representations of multiscale and multiphysics systems. GINNs address the twin challenges of removing intrinsic computational bottlenecks in physics-based models and generating large data sets for estimating probability distributions of quantities of interest (QoIs) with a high degree of confidence. Both the selection of the complex physics learned by the NN and its supervised learning/prediction are informed by the PGM, which includes the formulation of structured priors for tunable control variables (CVs) to account for their mutual correlations and ensure physically sound CV and QoI distributions. GINNs accelerate the prediction of QoIs essential for simulation-based decision-making where generating sufficient sample data using physics-based models alone is often prohibitively expensive. Using a real-world application grounded in supercapacitor-based energy storage, we describe the construction of GINNs from a Bayesian network-embedded homogenized model for supercapacitor dynamics, and demonstrate their ability to produce kernel density estimates of relevant non-Gaussian, skewed QoIs with tight confidence intervals.
△ Less
Submitted 26 June, 2020;
originally announced June 2020.
-
Direct method for the quantitative analysis of surface contamination on ultra-low background materials from exposure to dust
Authors:
M. L. di Vacri,
I. J. Arnquist,
S. Scorza,
E. W. Hoppe,
Jeter Hall
Abstract:
In this work we present a method for the direct determination of contaminant fallout rates on material surfaces from exposure to dust. Naturally occurring radionuclides K-40, Th-232, U-238 and stable Pb were investigated. Until now, background contributions from dust particulate have largely been estimated from fallout models and assumed dust composition. Our method utilizes a variety of low backg…
▽ More
In this work we present a method for the direct determination of contaminant fallout rates on material surfaces from exposure to dust. Naturally occurring radionuclides K-40, Th-232, U-238 and stable Pb were investigated. Until now, background contributions from dust particulate have largely been estimated from fallout models and assumed dust composition. Our method utilizes a variety of low background collection media for exposure in locations of interest, followed by surface leaching and leachate analysis using inductively coupled plasma mass spectrometry (ICP-MS). The method was validated and applied in selected locations at Pacific Northwest National Laboratory (PNNL) and the SNOLAB underground facility.
△ Less
Submitted 23 June, 2020;
originally announced June 2020.
-
Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic
Authors:
C. Galbiati,
A. Abba,
P. Agnes,
P. Amaudruz,
M. Arba,
F. Ardellier-Desages,
C. Badia,
G. Batignani,
G. Bellani,
G. Bianchi,
D. Bishop,
V. Bocci,
W. Bonivento,
B. Bottino,
M. Bouchard,
S. Brice,
G. Buccino,
S. Bussino,
A. Caminata,
A. Capra,
M. Caravati,
M. Carlini,
L. Carrozzi,
J. M. Cela,
B. Celano
, et al. (123 additional authors not shown)
Abstract:
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equ…
▽ More
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.
△ Less
Submitted 10 April, 2020; v1 submitted 23 March, 2020;
originally announced March 2020.
-
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
S. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
R. Filgas
, et al. (54 additional authors not shown)
Abstract:
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by…
▽ More
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by a hot-spike as previously supposed. Using this semi-empirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c$^{-2}$.
△ Less
Submitted 25 November, 2020; v1 submitted 29 May, 2019;
originally announced May 2019.
-
Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas
, et al. (47 additional authors not shown)
Abstract:
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total backgr…
▽ More
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$ cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.
△ Less
Submitted 11 February, 2019;
originally announced February 2019.
-
Develo** a Bubble Chamber Particle Discriminator Using Semi-Supervised Learning
Authors:
B. Matusch,
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis
, et al. (48 additional authors not shown)
Abstract:
The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually develo** a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing…
▽ More
The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually develo** a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing formats and neural network architectures are applied to the task. First, they are optimized in a supervised learning context. Next, two novel semi-supervised learning algorithms are trained, and found to replicate the Acoustic Parameter (AP) discriminator previously used in PICO-60 with a mean of 97% accuracy.
△ Less
Submitted 27 November, 2018;
originally announced November 2018.
-
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
W. Baker,
D. Balakishiyeva,
S. Banik,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
H. Chagani,
Y. -Y. Chang,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman
, et al. (84 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absol…
▽ More
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.
△ Less
Submitted 27 July, 2018; v1 submitted 7 March, 2018;
originally announced March 2018.
-
Eigenstates in the Many Interacting Worlds approach: Ground states in 1D and 2D and excited states in 1D (long version)
Authors:
Hannes Herrmann,
Michael J. W. Hall,
Howard M. Wiseman,
Dirk - André Deckert
Abstract:
Recently the Many-Interacting-Worlds (MIW) approach to a quantum theory without wave functions was proposed. This approach leads quite naturally to numerical integrators of the Schrödinger equation. It has been suggested that such integrators may feature advantages over fixed-grid methods for higher numbers of degrees of freedom. However, as yet, little is known about concrete MIW models for more…
▽ More
Recently the Many-Interacting-Worlds (MIW) approach to a quantum theory without wave functions was proposed. This approach leads quite naturally to numerical integrators of the Schrödinger equation. It has been suggested that such integrators may feature advantages over fixed-grid methods for higher numbers of degrees of freedom. However, as yet, little is known about concrete MIW models for more than one spatial dimension and/or more than one particle. In this work we develop the MIW approach further to treat arbitrary degrees of freedom, and provide a systematic study of a corresponding numerical implementation for computing one-particle ground and excited states in one dimension, and ground states in two spatial dimensions. With this step towards the treatment of higher degrees of freedom we hope to stimulate their further study.
△ Less
Submitted 5 July, 2023; v1 submitted 5 December, 2017;
originally announced December 2017.
-
Biological Cell Resonators
Authors:
Jonathan M. M. Hall
Abstract:
This thesis develops the theory of whispering gallery modes, exploring under what conditions a micro or nanoscale device can sustain these resonances, and for which physical criteria the resonance conditions deteriorate. The study is then extended to consider the biological cell in which modes are definitively sustained without artificial assistance. The properties of resonators and their emitted…
▽ More
This thesis develops the theory of whispering gallery modes, exploring under what conditions a micro or nanoscale device can sustain these resonances, and for which physical criteria the resonance conditions deteriorate. The study is then extended to consider the biological cell in which modes are definitively sustained without artificial assistance. The properties of resonators and their emitted energy spectra are studied within the general framework of the Finite Difference Time Domain method, requiring supercomputing resources to probe the transient behaviour and interactions among the electromagnetic fields. The formal theory of Mie scattering is also extended to develop a cutting-edge, computationally efficient model for general, multilayer microspheres, which represents a valuable achievement for the scientific community in its own right. The model unifies the approaches in the field of mathematical modelling to express the energy spectrum in a single encompassing equation, which is then applied in a range of contexts. The gulf between modelling and biological resonators is bridged by an in-depth study of the physical characteristics of a range of biological cells, and the selection criteria for viable resonator candidates are developed through a number of detailed feasibility studies. The bovine embryo is consequently selected as the optimal choice for this investigation. Evidence is established for the ability of a bovine embryo to sustain whispering gallery modes. The ability of a cell to sustain modes on its own represents a conceptually elegant paradigm for new technologies involving on-site cell interrogation and reporting of the status and health of a biological cell in the future. The methodological and technological developments contained herein thus become a vital asset for the future realisation of autonomous biological cell sensors.
△ Less
Submitted 9 September, 2018; v1 submitted 8 September, 2017;
originally announced September 2017.
-
An ultrastable silicon cavity in a continuously operating closed-cycle cryostat at 4 K
Authors:
W. Zhang,
J. M. Robinson,
L. Sonderhouse,
E. Oelker,
C. Benko,
J. L. Hall,
T. Legero,
D. G. Matei,
F. Riehle,
U. Sterr,
J. Ye
Abstract:
We report on a laser locked to a silicon cavity operating continuously at 4 K with $1 \times 10^{-16}$ instability and a median linewidth of 17 mHz at 1542 nm. This is a ten-fold improvement in short-term instability, and a $10^4$ improvement in linewidth, over previous sub-10 K systems. Operating at low temperatures reduces the thermal noise floor, and thus is advantageous toward reaching an inst…
▽ More
We report on a laser locked to a silicon cavity operating continuously at 4 K with $1 \times 10^{-16}$ instability and a median linewidth of 17 mHz at 1542 nm. This is a ten-fold improvement in short-term instability, and a $10^4$ improvement in linewidth, over previous sub-10 K systems. Operating at low temperatures reduces the thermal noise floor, and thus is advantageous toward reaching an instability of $10^{-18}$, a long-sought goal of the optical clock community. The performance of this system demonstrates the technical readiness for the development of the next generation of ultrastable lasers that operate with ultranarrow linewidth and long-term stability without user intervention.
△ Less
Submitted 5 November, 2017; v1 submitted 17 August, 2017;
originally announced August 2017.
-
Low-Mass Dark Matter Search with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. Chang,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell
, et al. (83 additional authors not shown)
Abstract:
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is…
▽ More
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
△ Less
Submitted 18 January, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
P. Campion,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
G. Crowder,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas,
F. Girard
, et al. (37 additional authors not shown)
Abstract:
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less th…
▽ More
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than 1 event per month. A blind analysis of an efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 3.4 $\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one order of magnitude improvement from previous PICO results.
△ Less
Submitted 2 August, 2017; v1 submitted 24 February, 2017;
originally announced February 2017.
-
Synergistic Dynamic Theory of Complex Coevolutionary Systems: Disentangling Nonlinear Spatiotemporal Controls on Precipitation
Authors:
Rui A. P. Perdigão,
Carlos A. L. Pires,
Julia Hall
Abstract:
We formulate a nonlinear synergistic theory of coevolutionary systems, disentangling and explaining dynamic complexity in terms of fundamental processes for optimised data analysis and dynamic model design: Dynamic Source Analysis (DSA). DSA provides a nonlinear dynamical basis for spatiotemporal datasets or dynamical models, eliminating redundancies and expressing the system in terms of the small…
▽ More
We formulate a nonlinear synergistic theory of coevolutionary systems, disentangling and explaining dynamic complexity in terms of fundamental processes for optimised data analysis and dynamic model design: Dynamic Source Analysis (DSA). DSA provides a nonlinear dynamical basis for spatiotemporal datasets or dynamical models, eliminating redundancies and expressing the system in terms of the smallest number of fundamental processes and interactions without loss of information. This optimises model design in dynamical systems, expressing complex coevolution in simple synergistic terms, yielding physically meaningful spatial and temporal structures. These are extracted by spatiotemporal decomposition of nonlinearly interacting subspaces via the novel concept of a Spatiotemporal Coevolution Manifold. Physical consistency is ensured and mathematical ambiguities are avoided with fundamental principles on energy minimisation and entropy production. The relevance of DSA is illustrated by retrieving a non-redundant, synergistic set of nonlinear geophysical processes exerting control over precipitation in space and time over the Euro-Atlantic region. For that purpose, a nonlinear spatiotemporal basis is extracted from geopotential data fields, yielding two independent dynamic sources dominated respectively by meridional and zonal circulation gradients. These sources are decomposed into spatial and temporal structures corresponding to multiscale climate dynamics. The added value of nonlinear predictability is brought out in the geospatial evaluation and dynamic simulation of evolving precipitation distributions from the geophysical controls, using DSA-driven model building and implementation. The simulated precipitation is found to be in agreement with observational data, which they not only describe but also dynamically link and attribute in synergistic terms of the retrieved dynamic sources.
△ Less
Submitted 10 November, 2016;
originally announced November 2016.
-
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
I. Arnquist,
W. Baker,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty
, et al. (71 additional authors not shown)
Abstract:
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle…
▽ More
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.
△ Less
Submitted 30 September, 2016;
originally announced October 2016.
-
Improved dark matter search results from PICO-2L Run 2
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
M. Das,
F. Debris,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas,
M. Fines-Neuschild,
F. Girard,
G. Giroux
, et al. (33 additional authors not shown)
Abstract:
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nu…
▽ More
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nuclear-recoil event was observed in the data, consistent both with the predicted background rate from neutrons and with the observed rate of unambiguous multiple-bubble neutron scattering events. The chamber exhibits the same excellent electron-recoil and alpha decay rejection as was previously reported. These data provide the most stringent direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.
△ Less
Submitted 25 March, 2016; v1 submitted 14 January, 2016;
originally announced January 2016.
-
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Authors:
C. Amole,
M. Ardid,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
S. Daley,
M. Das,
F. Debris,
N. Dhungana,
J. Farine,
I. Felis,
R. Filgas,
F. Girard,
G. Giroux,
A. Grandison
, et al. (34 additional authors not shown)
Abstract:
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays…
▽ More
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. These behaviors allow for analysis cuts to remove all background events while retaining $48.2\%$ of the exposure. Stringent limits on weakly interacting massive particles interacting via spin-dependent proton and spin-independent processes are set, and most interpretations of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei are ruled out.
△ Less
Submitted 3 March, 2016; v1 submitted 26 October, 2015;
originally announced October 2015.
-
Innovative Science
Authors:
Donald W Braben,
John F Allen,
William Amos,
Richard Ball,
Hagan Bayley,
Tim Birkhead,
Peter Cameron,
Eleanor Campbell,
Richard Cogdell,
David Colquhoun,
Steve Davies,
Rod Dowler,
Peter Edwards,
Irene Engle,
Felipe Fernandez-Armesto,
Desmond Fitzgerald,
Jon Frampton,
Dame Anne Glover,
John Hall,
Pat Heslop-Harrison,
Dudley Herschbach,
Sui Huang,
H Jeff Kimble,
Sir Harry Kroto,
James Ladyman
, et al. (23 additional authors not shown)
Abstract:
Sir, We write as senior scientists about a problem vital to the scientific enterprise and prosperity. Nowadays, funding is a lengthy and complex business. First, universities themselves must approve all proposals for submission. Funding agencies then subject those that survive to peer review, a process by which a few researchers, usually acting anonymously, assess a proposal's chances that it will…
▽ More
Sir, We write as senior scientists about a problem vital to the scientific enterprise and prosperity. Nowadays, funding is a lengthy and complex business. First, universities themselves must approve all proposals for submission. Funding agencies then subject those that survive to peer review, a process by which a few researchers, usually acting anonymously, assess a proposal's chances that it will achieve its goals, is the best value for money, is relevant to a national priority and will impact on a socio-economic problem. Only 25% of proposals received by the funding agencies are funded. These protracted processes force researchers to exploit existing knowledge, severely discourage open-ended studies and are hugely time-consuming. They are also new: before 1970, few researchers wrote proposals. Now they are virtually mandatory.
△ Less
Submitted 23 September, 2015;
originally announced October 2015.
-
WIMP-Search Results from the Second CDMSlite Run
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aramaki,
M. Asai,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal
, et al. (65 additional authors not shown)
Abstract:
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization…
▽ More
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
△ Less
Submitted 9 March, 2016; v1 submitted 8 September, 2015;
originally announced September 2015.
-
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
S. Daley,
M. Das,
F. Debris,
N. Dhungana,
J. Farine,
I. Felis,
R. Filgas,
M. Fines-Neuschild,
F. Girard,
G. Giroux
, et al. (32 additional authors not shown)
Abstract:
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation o…
▽ More
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation of a dependence of acoustic signal on alpha energy. Twelve single nuclear recoil event candidates were observed during the run. The candidate events exhibit timing characteristics that are not consistent with the hypothesis of a uniform time distribution, and no evidence for a dark matter signal is claimed. These data provide the most sensitive direct detection constraints on WIMP-proton spin-dependent scattering to date, with significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon scattering.
△ Less
Submitted 29 June, 2015; v1 submitted 27 February, 2015;
originally announced March 2015.
-
Predicting the whispering gallery mode spectra of microresonators
Authors:
Jonathan M. M. Hall,
Shahraam Afshar V.,
Matthew R. Henderson,
Alexandre Francois,
Tess Reynolds,
Nicolas Riesen,
Tanya M. Monro
Abstract:
The whispering gallery modes (WGMs) of optical resonators have prompted intensive research efforts due to their usefulness in the field of biological sensing, and their employment in nonlinear optics. While much information is available in the literature on numerical modeling of WGMs in microspheres, it remains a challenging task to be able to predict the emitted spectra of spherical microresonato…
▽ More
The whispering gallery modes (WGMs) of optical resonators have prompted intensive research efforts due to their usefulness in the field of biological sensing, and their employment in nonlinear optics. While much information is available in the literature on numerical modeling of WGMs in microspheres, it remains a challenging task to be able to predict the emitted spectra of spherical microresonators. Here, we establish a customizable Finite- Difference Time-Domain (FDTD)-based approach to investigate the WGM spectrum of microspheres. The simulations are carried out in the vicinity of a dipole source rather than a typical plane-wave beam excitation, thus providing an effective analogue of the fluorescent dye or nanoparticle coatings used in experiment. The analysis of a single dipole source at different positions on the surface or inside a microsphere, serves to assess the relative efficiency of nearby radiating TE and TM modes, characterizing the profile of the spectrum. By varying the number, positions and alignments of the dipole sources, different excitation scenarios can be compared to analytic models, and to experimental results. The energy flux is collected via a nearby disk-shaped region. The resultant spectral profile shows a dependence on the configuration of the dipole sources. The power outcoupling can then be optimized for specific modes and wavelength regions. The development of such a computational tool can aid the preparation of optical sensors prior to fabrication, by preselecting desired the optical properties of the resonator.
△ Less
Submitted 11 March, 2015; v1 submitted 14 January, 2015;
originally announced January 2015.
-
Focal mechanism estimation by classification
Authors:
Ben G. Lasscock,
Brendon J. Hall,
Michael E. Glinsky
Abstract:
A classification technique for identifying focal mechanism type and fault plane orientation based on the polarity of P-wave "first motion" data is derived. A support vector machine is used to classify the polarity data in the space of spherical harmonic functions. The classification is non-parametric in the sense that there is no requirement to make a priori assumptions source mechanism. A metric…
▽ More
A classification technique for identifying focal mechanism type and fault plane orientation based on the polarity of P-wave "first motion" data is derived. A support vector machine is used to classify the polarity data in the space of spherical harmonic functions. The classification is non-parametric in the sense that there is no requirement to make a priori assumptions source mechanism. A metric of similarity potentially able to distinguish shear versus tensile dislocation without requiring estimation of the fault plane orientation is a natural consequence of this procedure. Going further, correlation functions between template source mechanism is derived, gives an estimate of fault plane orientation assuming a particular source mechanism.
△ Less
Submitted 31 October, 2014;
originally announced October 2014.