-
Large-scale detector testing for the GAPS Si(Li) Tracker
Authors:
Mengjiao Xiao,
Achim Stoessl,
Brandon Roach,
Cory Gerrity,
Ian Bouche,
Gabriel Bridges,
Philip von Doetinchem,
Charles J. Hailey,
Derik Kraych,
Anika Katt,
Michael Law,
Alexander Lowell,
Evan Martinez,
Kerstin Perez,
Maggie Reed,
Chelsea Rodriguez,
Nathan Saffold,
Ceaser Stringfield,
Hershel Weiner,
Kelsey Yee
Abstract:
Lithium-drifted silicon [Si(Li)] has been used for decades as an ionizing radiation detector in nuclear, particle, and astrophysical experiments, though such detectors have frequently been limited to small sizes (few cm$^2$) and cryogenic operating temperatures. The 10-cm-diameter Si(Li) detectors developed for the General Antiparticle Spectrometer (GAPS) balloon-borne dark matter experiment are n…
▽ More
Lithium-drifted silicon [Si(Li)] has been used for decades as an ionizing radiation detector in nuclear, particle, and astrophysical experiments, though such detectors have frequently been limited to small sizes (few cm$^2$) and cryogenic operating temperatures. The 10-cm-diameter Si(Li) detectors developed for the General Antiparticle Spectrometer (GAPS) balloon-borne dark matter experiment are novel particularly for their requirements of low cost, large sensitive area (~10 m$^2$ for the full 1440-detector array), high temperatures (near -40$\,^\circ$C), and energy resolution below 4 keV FWHM for 20--100-keV x-rays. Previous works have discussed the manufacturing, passivation, and small-scale testing of prototype GAPS Si(Li) detectors. Here we show for the first time the results from detailed characterization of over 1100 flight detectors, illustrating the consistent intrinsic low-noise performance of a large sample of GAPS detectors. This work demonstrates the feasibility of large-area and low-cost Si(Li) detector arrays for next-generation astrophysics and nuclear physics applications.
△ Less
Submitted 7 September, 2023; v1 submitted 29 April, 2023;
originally announced May 2023.
-
Sensitivity of the GAPS Experiment to Low-energy Cosmic-ray Antiprotons
Authors:
Field Rogers,
Tsuguo Aramaki,
Mirko Boezio,
Steven Boggs,
Valter Bonvicini,
Gabriel Bridges,
Donatella Campana,
William W. Craig,
Philip von Doetinchem,
Eric Everson,
Lorenzo Fabris,
Sydney Feldman,
Hideyuki Fuke,
Florian Gahbauer,
Cory Gerrity,
Charles J. Hailey,
Takeru Hayashi,
Akiko Kawachi,
Masayoshi Kozai,
Alex Lenni,
Alexander Lowell,
Massimo Manghisoni,
Nadir Marcelli,
Brent Mochizuki,
Isaac Mognet
, et al. (28 additional authors not shown)
Abstract:
The General Antiparticle Spectrometer (GAPS) is an upcoming balloon mission to measure low-energy cosmic-ray antinuclei during at least three ~35-day Antarctic flights. With its large geometric acceptance and novel exotic atom-based particle identification, GAPS will detect ~500 cosmic antiprotons per flight and produce a precision cosmic antiproton spectrum in the kinetic energy range of ~0.07-0.…
▽ More
The General Antiparticle Spectrometer (GAPS) is an upcoming balloon mission to measure low-energy cosmic-ray antinuclei during at least three ~35-day Antarctic flights. With its large geometric acceptance and novel exotic atom-based particle identification, GAPS will detect ~500 cosmic antiprotons per flight and produce a precision cosmic antiproton spectrum in the kinetic energy range of ~0.07-0.21 GeV/n at the top of the atmosphere. With these high statistics extending to lower energies than any previous experiment, and with complementary sources of experimental uncertainty compared to traditional magnetic spectrometers, the GAPS antiproton measurement will be sensitive to dark matter, primordial black holes, and cosmic ray propagation. The antiproton measurement will also validate the GAPS antinucleus identification technique for the antideuteron and antihelium rare-event searches. This analysis demonstrates the GAPS sensitivity to cosmic-ray antiprotons using a full instrument simulation and event reconstruction, and including solar and atmospheric effects.
△ Less
Submitted 5 November, 2022; v1 submitted 26 June, 2022;
originally announced June 2022.
-
Statistical investigation of the large-area Si(Li) detectors mass-produced for the GAPS experiment
Authors:
M. Kozai,
K. Tokunaga,
H. Fuke,
M. Yamada,
C. J. Hailey,
C. Kato,
D. Kraych,
M. Law,
E. Martinez,
K. Munakata,
K. Perez,
F. Rogers,
N. Saffold,
Y. Shimizu,
K. Tokuda,
M. Xiao
Abstract:
The lithium-drifted silicon (Si(Li)) detector developed for the General Antiparticle Spectrometer (GAPS) experiment features a thick (~2.2 mm) sensitive layer, large (10 cm) diameter, and excellent energy resolution (~4 keV for 20-100 keV X-rays) at a relatively high operating temperature (approximately -40C). Mass production of GAPS Si(Li) detectors has been performed to construct a large-volume…
▽ More
The lithium-drifted silicon (Si(Li)) detector developed for the General Antiparticle Spectrometer (GAPS) experiment features a thick (~2.2 mm) sensitive layer, large (10 cm) diameter, and excellent energy resolution (~4 keV for 20-100 keV X-rays) at a relatively high operating temperature (approximately -40C). Mass production of GAPS Si(Li) detectors has been performed to construct a large-volume silicon tracker for GAPS. We achieved the first success of the mass production of large-area Si(Li) detectors with a high (~90%) yield rate. Valuable datasets related to detector fabrication, such as detector performance and manufacturing parameters, were recorded and collected during the mass production. This study analyzes the datasets using statistical methods with the aim of comprehensively examining the mass production and to gain valuable insight into the fabrication method. Sufficient uniformities of the performance parameters (leakage current and capacitance) between detectors and strips are found, demonstrating high-quality and stable mass production. We also search for correlations between detector performance and manufacturing parameters by using data-mining techniques. Conventional multivariate analysis (multiple regression analysis) and machine-learning techniques (regression tree analysis) are complementarily used, and it is found that the Li-drift process makes a significant contribution to the performance parameters of the finished detectors. Detailed investigation of the drift process is performed using environmental data, and physical interpretations are presented. Our results provide valuable insight into the fabrication methods for this kind of large-area Si(Li) detector, and encourages future projects that require large-volume silicon trackers.
△ Less
Submitted 1 May, 2022; v1 submitted 11 November, 2021;
originally announced November 2021.
-
Passivation of Si(Li) detectors operated above cryogenic temperatures for space-based applications
Authors:
Nathan Saffold,
Field Rogers,
Mengjiao Xiao,
Radhika Bhatt,
Tyler Erjavec,
Hideyuki Fuke,
Charles J. Hailey,
Masayoshi Kozai,
Derik Kraych,
Evan Martinez,
Cianci Melo-Carrillo,
Kerstin Perez,
Chelsea Rodriguez,
Yuki Shimizu,
Brian Smallshaw
Abstract:
This work evaluates the viability of polyimide and parylene-C for passivation of lithium-drifted silicon (Si(Li)) detectors. The passivated Si(Li) detectors will form the particle tracker and X-ray detector of the General Antiparticle Spectrometer (GAPS) experiment, a balloon-borne experiment optimized to detect cosmic antideuterons produced in dark matter annihilations or decays. Successful passi…
▽ More
This work evaluates the viability of polyimide and parylene-C for passivation of lithium-drifted silicon (Si(Li)) detectors. The passivated Si(Li) detectors will form the particle tracker and X-ray detector of the General Antiparticle Spectrometer (GAPS) experiment, a balloon-borne experiment optimized to detect cosmic antideuterons produced in dark matter annihilations or decays. Successful passivation coatings were achieved by thermally curing polyimides, and the optimized coatings form an excellent barrier against humidity and organic contamination. The passivated Si(Li) detectors deliver $\lesssim\,4$ keV energy resolution (FWHM) for 20$-$100 keV X-rays while operating at temperatures of $-$35 to $-45\,^{\circ}$C. This is the first reported successful passivation of Si(Li)-based X-ray detectors operated above cryogenic temperatures.
△ Less
Submitted 11 February, 2021;
originally announced February 2021.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
Large-area Si(Li) Detectors for X-ray Spectrometry and Particle Tracking for the GAPS Experiment
Authors:
Field Rogers,
Mengjiao Xiao,
Kerstin Perez,
Steven Boggs,
Tyler Erjavec,
Lorenzo Fabris,
Hideyuki Fuke,
Charles J. Hailey,
Masayoshi Kozai,
Alex Lowell,
Norman Madden,
Massimo Manghisoni,
Steve McBride,
Valerio Re,
Elisa Riceputi,
Nathan Saffold,
Yuki Shimizu,
Gianluigi Zampa
Abstract:
Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150°C above liquid nitrogen temperature, have been developed for the General Antiparticle Spectrometer (GAPS) balloon mission and will form the first such system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip detectors have been verified in the lab to provide <4 keV FWHM energy resolution for X-rays as well as tra…
▽ More
Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150°C above liquid nitrogen temperature, have been developed for the General Antiparticle Spectrometer (GAPS) balloon mission and will form the first such system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip detectors have been verified in the lab to provide <4 keV FWHM energy resolution for X-rays as well as tracking capability for charged particles, while operating in conditions (~-40°C and ~1 Pa) achievable on a long-duration balloon mission with a large detector payload. These characteristics enable the GAPS silicon tracker system to identify cosmic antinuclei via a novel technique based on exotic atom formation, de-excitation, and annihilation. Production and large-scale calibration of ~1000 detectors has begun for the first GAPS flight, scheduled for late 2021. The detectors developed for GAPS may also have other applications, for example in heavy nuclei identification.
△ Less
Submitted 13 December, 2019;
originally announced December 2019.
-
GAPS: Searching for Dark Matter using Antinuclei in Cosmic Rays
Authors:
R. Bird,
T. Aramaki,
M. Boezio,
S. E. Boggs,
V. Bonvicini,
D. Campana,
W. W. Craig,
E. Everson,
L. Fabris,
H. Fuke,
F. Gahbauer,
I. Garcia,
C. Gerrity,
C. J. Hailey,
T. Hayashi,
C. Kato,
A. Kawachi,
M. Kondo,
M. Kozai,
A. Lowell,
M. Manghisoni,
N. Marcelli,
M. Martucci,
S. I. Mognet,
K. Munakata
, et al. (25 additional authors not shown)
Abstract:
The General Antiparticle Spectrometer (GAPS) will carry out a sensitive dark matter search by measuring low-energy ($\mathrm{E} < 0.25 \mathrm{GeV/nucleon}$) cosmic ray antinuclei. The primary targets are low-energy antideuterons produced in the annihilation or decay of dark matter. At these energies antideuterons from secondary/tertiary interactions are expected to have very low fluxes, significa…
▽ More
The General Antiparticle Spectrometer (GAPS) will carry out a sensitive dark matter search by measuring low-energy ($\mathrm{E} < 0.25 \mathrm{GeV/nucleon}$) cosmic ray antinuclei. The primary targets are low-energy antideuterons produced in the annihilation or decay of dark matter. At these energies antideuterons from secondary/tertiary interactions are expected to have very low fluxes, significantly below those predicted by well-motivated, beyond the standard model theories. GAPS will also conduct low-energy antiproton and antihelium searches. Combined, these observations will provide a powerful search for dark matter and provide the best observations to date on primordial black hole evaporation on Galactic length scales.
The GAPS instrument detects antinuclei using the novel exotic atom technique. It consists of a central tracker with a surrounding time-of-flight (TOF) system. The tracker is a one cubic meter volume containing 10 cm-diameter lithium-drifted silicon (Si(Li)) detectors. The TOF is a plastic scintillator system that will both trigger the Si(Li) tracker and enable better reconstruction of particle tracks. After coming to rest in the tracker, antinuclei will form an excited exotic atom. This will then de-excite via characteristic X-ray transitions before producing a pion/proton star when the antiparticle annihilates with the nucleus. This unique event topology will give GAPS the nearly background-free detection capability required for a rare-event search.
Here we present the scientific motivation for the GAPS experiment, its design and its current status as it prepares for flight in the austral summer of 2021-22.
△ Less
Submitted 8 August, 2019;
originally announced August 2019.
-
Develo** a mass-production model of large-area Si(Li) detectors with high operating temperatures
Authors:
M. Kozai,
H. Fuke,
M. Yamada,
K. Perez,
T. Erjavec,
C. J. Hailey,
N. Madden,
F. Rogers,
N. Saffold,
D. Seyler,
Y. Shimizu,
K. Tokuda,
Y. Shimizu,
K. Tokuda,
M. Xiao
Abstract:
This study presents a fabrication process for lithium-drifted silicon (Si(Li)) detectors that, compared to previous methods, allows for mass production at a higher yield, while providing a large sensitive area and low leakage currents at relatively high temperatures. This design, developed for the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment, has an overall diamet…
▽ More
This study presents a fabrication process for lithium-drifted silicon (Si(Li)) detectors that, compared to previous methods, allows for mass production at a higher yield, while providing a large sensitive area and low leakage currents at relatively high temperatures. This design, developed for the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment, has an overall diameter of 10 cm, with ~9 cm of active area segmented into 8 readout strips, and an overall thickness of 2.5 mm, with $\gtrsim$2.2 mm ($\gtrsim$90%) sensitive thickness. An energy resolution $\lesssim$4 keV full-width at half-maximum (FWHM) for 20-100 keV X-rays is required at the operating temperature ~-40C, which is far above the liquid nitrogen temperatures conventionally used to achieve fine energy resolution. High-yield production is also required for GAPS, which consists of $\gtrsim$1000 detectors. Our specially-developed Si crystal and custom methods of Li evaporation, diffusion and drifting allow for a thick, large-area and uniform sensitive layer. We find that retaining a thin undrifted layer on the p-side of the detector drastically reduces the leakage current, which is a dominant component of the energy resolution at these temperatures. A guard-ring structure and optimal etching of the detector surface are also confirmed to suppress the leakage current. We report on the mass production of these detectors that is ongoing now, and demonstrate it is capable of delivering a high yield of ~90%.
△ Less
Submitted 27 August, 2019; v1 submitted 13 June, 2019;
originally announced June 2019.
-
Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment
Authors:
Field Rogers,
Mengjiao Xiao,
Kerstin M. Perez,
Steven Boggs,
Tyler Erjavec,
Lorenzo Fabris,
Hideyuki Fuke,
Charles J. Hailey,
Masayoshi Kozai,
Alex Lowell,
Norman Madden,
Massimo Manghisoni,
Steve McBride,
Valerio Re,
Elisa Riceputi,
Nathan Saffold,
Yuki Shimizu
Abstract:
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, performance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high altitude. These 10 cm…
▽ More
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, performance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high altitude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors provide the active area, X-ray absorption efficiency, energy resolution, and particle tracking capability necessary for the GAPS exotic-atom particle identification technique. In this paper, the detector performance is validated on the bases of X-ray energy resolution and reconstruction of cosmic minimum ionizing particle (MIP) signals. We use the established noise model for semiconductor detectors to distinguish sources of noise due to the detector from those due to signal processing electronics. We demonstrate that detectors with either 4 strips or 8 strips can provide the required $\lesssim$4 keV (FWHM) X-ray energy resolution at flight temperatures of $-35$ to $-45^{\circ}$C, given the proper choice of signal processing electronics. Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic balloon flight, scheduled for late 2021.
△ Less
Submitted 8 November, 2019; v1 submitted 31 May, 2019;
originally announced June 2019.
-
Astro 2020 Science White Paper: Cosmic-ray Antinuclei as Messengers for Dark Matter
Authors:
Kerstin Perez,
Philip von Doetinchem,
Tsuguo Aramaki,
Mirko Boezio,
Steven E. Boggs,
William W. Craig,
Lorenzo Fabris,
Hideyuki Fuke,
Florian Gahbauer,
Charles J. Hailey,
Rene Ong
Abstract:
The origin of dark matter is a driving question of modern physics. Low-energy antideuterons provide a "smoking gun" signature of dark matter annihilation or decay, essentially free of astrophysical background. Low-energy antiprotons are a vital partner for this analysis, and low-energy antihelium could provide further discovery space for new physics. In the coming decade, AMS-02 will continue accu…
▽ More
The origin of dark matter is a driving question of modern physics. Low-energy antideuterons provide a "smoking gun" signature of dark matter annihilation or decay, essentially free of astrophysical background. Low-energy antiprotons are a vital partner for this analysis, and low-energy antihelium could provide further discovery space for new physics. In the coming decade, AMS-02 will continue accumulating the large statistics and systematic understanding necessary for it to probe rare antinuclei signatures, and GAPS, which is the first experiment optimized specifically for low-energy cosmic antinuclei, will begin several Antarctic balloon campaigns. The connection of cosmic-ray antinuclei and dark matter is reviewed and the outlook in light of experimental progress is presented.
△ Less
Submitted 14 July, 2021; v1 submitted 11 April, 2019;
originally announced April 2019.
-
Development of Large-area Lithium-drifted Silicon Detectors for the GAPS Experiment
Authors:
M. Kozai,
H. Fuke,
M. Yamada,
T. Erjavec,
C. J. Hailey,
C. Kato,
N. Madden,
K. Munakata,
K. Perez,
F. Rogers,
N. Saffold,
Y. Shimizu,
K. Tokuda,
M. Xiao
Abstract:
We have developed large-area lithium-drifted silicon (Si(Li)) detectors to meet the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment. GAPS is an Antarctic balloon-borne mission scheduled for the first flight in late 2020. The GAPS experiment aims to survey low-energy cosmic-ray antinuclei, particularly antideuterons, which are recognized as essentially background-free…
▽ More
We have developed large-area lithium-drifted silicon (Si(Li)) detectors to meet the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment. GAPS is an Antarctic balloon-borne mission scheduled for the first flight in late 2020. The GAPS experiment aims to survey low-energy cosmic-ray antinuclei, particularly antideuterons, which are recognized as essentially background-free signals from dark matter annihilation or decay. The GAPS Si(Li) detector design is a thickness of 2.5 mm, diameter of 10 cm and 8 readout strips. The energy resolution of <4 keV (FWHM) for 20 to 100 keV X-rays at temperature of -35 to -45 C, far above the liquid nitrogen temperatures frequently used to achieve fine energy resolution, is required. We developed a high-quality Si crystal and Li-evaporation, diffusion and drift methods to form a uniform Li-drifted layer. Guard ring structure and optimal etching of the surface are confirmed to suppress the leakage current, which is a main source of noise. We found a thin un-drifted layer retained on the p-side effectively suppresses the leakage current. By these developments, we succeeded in develo** the GAPS Si(Li) detector. As the ultimate GAPS instrument will require >1000 10-cm diameter Si(Li) detectors to achieve high sensitivity to rare antideuteron events, high-yield production is also a key factor for the success of the GAPS mission.
△ Less
Submitted 18 December, 2018;
originally announced December 2018.
-
GAPS, low-energy antimatter for indirect dark-matter search
Authors:
E. Vannuccini,
T. Aramaki,
R. Bird,
M. Boezio,
S. E. Boggs,
V. Bonvicini,
D. Campana,
W. W. Craig,
P. von Doetinchem,
E. Everson,
L. Fabris,
F. Gahbauer,
C. Gerrity,
H. Fuke,
C. J. Hailey,
T. Hayashi,
C. Kato,
A. Kawachi,
M. Kozai,
A. Lowell,
M. Martucci,
S. I. Mognet,
R. Munini,
K. Munakata,
S. Okazaki
, et al. (15 additional authors not shown)
Abstract:
The General Antiparticle Spectrometer (GAPS) is designed to carry out indirect dark matter search by measuring low-energy cosmic-ray antiparticles. Below a few GeVs the flux of antiparticles produced by cosmic-ray collisions with the interstellar medium is expected to be very low and several well-motivated beyond-standard models predict a sizable contribution to the antideuteron flux. GAPS is plan…
▽ More
The General Antiparticle Spectrometer (GAPS) is designed to carry out indirect dark matter search by measuring low-energy cosmic-ray antiparticles. Below a few GeVs the flux of antiparticles produced by cosmic-ray collisions with the interstellar medium is expected to be very low and several well-motivated beyond-standard models predict a sizable contribution to the antideuteron flux. GAPS is planned to fly on a long-duration balloon over Antarctica in the austral summer of 2020. The primary detector is a 1m3 central volume containing planes of Si(Li) detectors. This volume is surrounded by a time-of-flight system to both trigger the Si(Li) detector and reconstruct the particle tracks. The detection principle of the experiment relies on the identification of the antiparticle annihilation pattern. Low energy antiparticles slow down in the apparatus and they are captured in the medium to form exotic excited atoms, which de-excite by emitting characteristic X-rays. Afterwards they undergo nuclear annihilation, resulting in a star of pions and protons. The simultaneous measurement of the stop** depth and the dE/dx loss of the primary antiparticle, of the X-ray energies and of the star particle-multiplicity provides very high rejection power, that is critical in rare-event search. GAPS will be able to perform a precise measurement of the cosmic antiproton flux below 250 MeV, as well as a sensitive search for antideuterons.
△ Less
Submitted 17 December, 2018;
originally announced December 2018.
-
GAPS: A New Cosmic Ray Anti-matter Experiment
Authors:
S. Quinn,
T. Aramaki,
R. Bird,
M. Boezio,
S. E. Boggs,
V. Bonvicini,
D. Campana,
W. W. Craig,
P. von Doetinchem,
E. Everson,
L. Fabris,
F. Gahbauer,
C. Gerrity,
H. Fuke,
C. J. Hailey,
T. Hayashi,
C. Kato,
A. Kawachi,
M. Kozai,
A. Lowell,
M. Martucci,
S. I. Mognet,
R. Munini,
K. Munakata,
S. Okazaki
, et al. (15 additional authors not shown)
Abstract:
The General AntiParticle Spectrometer (GAPS) is a balloon-borne instrument designed to detect cosmic-ray antimatter using the novel exotic atom technique, obviating the strong magnetic fields required by experiments like AMS, PAMELA, or BESS. It will be sensitive to primary antideuterons with kinetic energies of $\approx0.05-0.2$ GeV/nucleon, providing some overlap with the previously mentioned ex…
▽ More
The General AntiParticle Spectrometer (GAPS) is a balloon-borne instrument designed to detect cosmic-ray antimatter using the novel exotic atom technique, obviating the strong magnetic fields required by experiments like AMS, PAMELA, or BESS. It will be sensitive to primary antideuterons with kinetic energies of $\approx0.05-0.2$ GeV/nucleon, providing some overlap with the previously mentioned experiments at the highest energies. For $3\times35$ day balloon flights, and standard classes of primary antideuteron propagation models, GAPS will be sensitive to $m_{\mathrm{DM}}\approx10-100$ GeV c$^{-2}$ WIMPs with a dark-matter flux to astrophysical flux ratio approaching 100. This clean primary channel is a key feature of GAPS and is crucial for a rare event search. Additionally, the antiproton spectrum will be extended with high statistics measurements to cover the $0.07 \leq E \leq 0.25 $ GeV domain. For $E>0.2$ GeV GAPS data will be complementary to existing experiments, while $E<0.2$ GeV explores a new regime. The first flight is scheduled for late 2020 in Antarctica. These proceedings will describe the astrophysical processes and backgrounds relevant to the dark matter search, a brief discussion of detector operation, and construction progress made to date.
△ Less
Submitted 25 September, 2018;
originally announced September 2018.
-
Improved Search for Solar Chameleons with a GridPix Detector at CAST
Authors:
V. Anastassopoulos,
S. Aune,
K. Barth,
A. Belov,
H. Bräuninger,
G. Cantatore,
J. M. Carmona,
J. F. Castel,
S. A. Cetin,
F. Christensen,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
H. Fischer,
W. Funk,
J. A. García,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis,
T. Geralis
, et al. (44 additional authors not shown)
Abstract:
We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling,…
▽ More
We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling, $β_γ< 5.7\times10^{10}$ for $1<β_\mathrm{m}<10^6$ at 95% C.L. improving our previous results by a factor two and for the first time reaching sensitivity below the solar luminosity bound for tachocline magnetic fields up to $12.5\,\mathrm{T}$.
△ Less
Submitted 8 November, 2018; v1 submitted 31 July, 2018;
originally announced August 2018.
-
Fabrication of low-cost, large-area prototype Si(Li) detectors for the GAPS experiment
Authors:
Kerstin Perez,
Tsuguo Aramaki,
Charles J. Hailey,
Rachel Carr,
Tyler Erjavec,
Hideyuki Fuke,
Amani Garvin,
Cassia Harper,
Glenn Kewley,
Norman Madden,
Sarah Mechbal,
Field Rogers,
Nathan Saffold,
Gordon Tajiri,
Katsuhiko Tokuda,
Jason Williams,
Minoru Yamada
Abstract:
A Si(Li) detector fabrication procedure has been developed with the aim of satisfying the unique requirements of the GAPS (General Antiparticle Spectrometer) experiment. Si(Li) detectors are particularly well-suited to the GAPS detection scheme, in which several planes of detectors act as the target to slow and capture an incoming antiparticle into an exotic atom, as well as the spectrometer and t…
▽ More
A Si(Li) detector fabrication procedure has been developed with the aim of satisfying the unique requirements of the GAPS (General Antiparticle Spectrometer) experiment. Si(Li) detectors are particularly well-suited to the GAPS detection scheme, in which several planes of detectors act as the target to slow and capture an incoming antiparticle into an exotic atom, as well as the spectrometer and tracker to measure the resulting decay X-rays and annihilation products. These detectors must provide the absorption depth, energy resolution, tracking efficiency, and active area necessary for this technique, all within the significant temperature, power, and cost constraints of an Antarctic long-duration balloon flight. We report here on the fabrication and performance of prototype 2"-diameter, 1-1.25 mm-thick, single-strip Si(Li) detectors that provide the necessary X-ray energy resolution of $\sim$4 keV for a cost per unit area that is far below that of previously-acquired commercial detectors. This fabrication procedure is currently being optimized for the 4"-diameter, 2.5 mm-thick, multi-strip geometry that will be used for the GAPS flight detectors.
△ Less
Submitted 20 July, 2018;
originally announced July 2018.
-
First NuSTAR Limits on Quiet Sun Hard X-Ray Transient Events
Authors:
Andrew J. Marsh,
David M. Smith,
Lindsay Glesener,
Iain G. Hannah,
Brian W. Grefenstette,
Amir Caspi,
Säm Krucker,
Hugh S. Hudson,
Kristin K. Madsen,
Stephen M. White,
Matej Kuhar,
Paul J. Wright,
Steven E. Boggs,
Finn E. Christensen,
William W. Craig,
Charles J. Hailey,
Fiona A. Harrison,
Daniel Stern,
William W. Zhang
Abstract:
We present the first results of a search for transient hard X-ray (HXR) emission in the quiet solar corona with the \textit{Nuclear Spectroscopic Telescope Array} (\textit{NuSTAR}) satellite. While \textit{NuSTAR} was designed as an astrophysics mission, it can observe the Sun above 2~keV with unprecedented sensitivity due to its pioneering use of focusing optics. \textit{NuSTAR} first observed qu…
▽ More
We present the first results of a search for transient hard X-ray (HXR) emission in the quiet solar corona with the \textit{Nuclear Spectroscopic Telescope Array} (\textit{NuSTAR}) satellite. While \textit{NuSTAR} was designed as an astrophysics mission, it can observe the Sun above 2~keV with unprecedented sensitivity due to its pioneering use of focusing optics. \textit{NuSTAR} first observed quiet Sun regions on 2014 November 1, although out-of-view active regions contributed a notable amount of background in the form of single-bounce (unfocused) X-rays. We conducted a search for quiet Sun transient brightenings on time scales of 100 s and set upper limits on emission in two energy bands. We set 2.5--4~keV limits on brightenings with time scales of 100 s, expressed as the temperature T and emission measure EM of a thermal plasma. We also set 10--20~keV limits on brightenings with time scales of 30, 60, and 100 s, expressed as model-independent photon fluxes. The limits in both bands are well below previous HXR microflare detections, though not low enough to detect events of equivalent T and EM as quiet Sun brightenings seen in soft X-ray observations. We expect future observations during solar minimum to increase the \textit{NuSTAR} sensitivity by over two orders of magnitude due to higher instrument livetime and reduced solar background.
△ Less
Submitted 14 November, 2017;
originally announced November 2017.
-
New CAST Limit on the Axion-Photon Interaction
Authors:
CAST collaboration,
V. Anastassopoulos,
S. Aune,
K. Barth,
A. Belov,
H. Brauninger,
G. Cantatore,
J. M. Carmona,
J. F. Castel,
S. A. Cetin,
F. Christensen,
J. I. Collar,
T. Dafni,
M. Davenport,
T. A. Decker,
A. Dermenev,
K. Desch,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
H. Fischer,
J. A. Garcia,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis
, et al. (42 additional authors not shown)
Abstract:
During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a worl…
▽ More
During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a world leading limit of $g_{aγ} < 0.66 \times 10^{-10} {\rm GeV}^{-1}$ (95% C.L.) on the axion-photon coupling strength for $m_a \lesssim 0.02$ eV. Compared with the first vacuum phase (2003--2004), the sensitivity was vastly increased with low-background x-ray detectors and a new x-ray telescope. These innovations also serve as pathfinders for a possible next-generation axion helioscope.
△ Less
Submitted 20 December, 2017; v1 submitted 5 May, 2017;
originally announced May 2017.
-
A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research
Authors:
F. Aznar,
J. Castel,
F. E. Christensen,
T. Dafni,
T. A. Decker,
E. Ferrer-Ribas,
J. A. Garcia,
I. Giomataris,
J. G. Gracia,
C. J. Hailey,
R. M. Hill,
F. J. Iguaz,
I. G. Irastorza,
A. C. Jakobsen,
G. Luzon,
H. Mirallas,
T. Papaevangelou,
M. J. Pivovaroff,
J. Ruz,
T. Vafeiadis,
J. K. Vogel
Abstract:
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed…
▽ More
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed (or "slumped") glass substrates deposited with multilayer coatings. The system has been conceived as a technological pathfinder for the future International Axion Observatory (IAXO), as it combines two of the techniques (optic and detector) proposed in the conceptual design of the project. It is innovative for two reasons: it is the first time an x-ray optic has been designed and fabricated specifically for axion research, and the first time a Micromegas detector has been operated with an x-ray optic. The line has been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and is currently looking for solar axions. The combination of the XRT and Micromegas detector provides the best signal-to-noise ratio obtained so far by any detection system of the CAST experiment with a background rate of 5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and signal spot area.
△ Less
Submitted 21 September, 2015;
originally announced September 2015.
-
GAPS - Dark matter search with low-energy cosmic-ray antideuterons and antiprotons
Authors:
P. von Doetinchem,
T. Aramaki,
S. Boggs,
H. Fuke,
C. J. Hailey,
S. I. Mognet,
R. A. Ong,
K. Perez,
J. Zweerink
Abstract:
The GAPS experiment is foreseen to carry out a dark matter search by measuring low-energy cosmic-ray antideuterons and antiprotons with a novel detection approach. It will provide a new avenue to access a wide range of different dark matter models and masses from about 10GeV to 1TeV. The theoretically predicted antideuteron flux resulting from secondary interactions of primary cosmic rays is very…
▽ More
The GAPS experiment is foreseen to carry out a dark matter search by measuring low-energy cosmic-ray antideuterons and antiprotons with a novel detection approach. It will provide a new avenue to access a wide range of different dark matter models and masses from about 10GeV to 1TeV. The theoretically predicted antideuteron flux resulting from secondary interactions of primary cosmic rays is very low. Well-motivated theories beyond the Standard Model contain viable dark matter candidates, which could lead to a significant enhancement of the antideuteron flux due to annihilation or decay of dark matter particles. This flux contribution is believed to be especially large at low energies, which leads to a high discovery potential for GAPS. The GAPS low-energy antiproton search will provide some of the most stringent constraints on ~30GeV dark matter, will provide the best limits on primordial black hole evaporation on galactic length scales, and explore new discovery space in cosmic-ray physics.
GAPS is designed to achieve its goals via long duration balloon flights at high altitude in Antarctica. The detector itself will consist of 10 planes of Si(Li) solid state detectors and a surrounding time-of-flight system. Antideuterons and antiprotons will be slowed down in the Si(Li) material, replace a shell electron and form an excited exotic atom. The atom will be deexcited by characteristic X-ray transitions and will end its life by the formation of an annihilation pion/proton star. This unique event structure will deliver a nearly background free detection possibility.
△ Less
Submitted 13 August, 2015; v1 submitted 9 July, 2015;
originally announced July 2015.
-
Conceptual Design of the International Axion Observatory (IAXO)
Authors:
E. Armengaud,
F. T. Avignone,
M. Betz,
P. Brax,
P. Brun,
G. Cantatore,
J. M. Carmona,
G. P. Carosi,
F. Caspers,
S. Caspi,
S. A. Cetin,
D. Chelouche,
F. E. Christensen,
A. Dael,
T. Dafni,
M. Davenport,
A. V. Derbin,
K. Desch,
A. Diago,
B. Döbrich,
I. Dratchnev,
A. Dudarev,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas
, et al. (63 additional authors not shown)
Abstract:
The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion heliosc…
▽ More
The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion helioscope, reaching sensitivity to axion-photon couplings down to a few $\times 10^{-12}$ GeV$^{-1}$ and thus probing a large fraction of the currently unexplored axion and ALP parameter space. IAXO will also be sensitive to solar axions produced by mechanisms mediated by the axion-electron coupling $g_{ae}$ with sensitivity $-$for the first time$-$ to values of $g_{ae}$ not previously excluded by astrophysics. With several other possible physics cases, IAXO has the potential to serve as a multi-purpose facility for generic axion and ALP research in the next decade. In this paper we present the conceptual design of IAXO, which follows the layout of an enhanced axion helioscope, based on a purpose-built 20m-long 8-coils toroidal superconducting magnet. All the eight 60cm-diameter magnet bores are equipped with focusing x-ray optics, able to focus the signal photons into $\sim 0.2$ cm$^2$ spots that are imaged by ultra-low-background Micromegas x-ray detectors. The magnet is built into a structure with elevation and azimuth drives that will allow for solar tracking for $\sim$12 h each day.
△ Less
Submitted 14 January, 2014;
originally announced January 2014.
-
A Measurement of Atomic X-ray Yields in Exotic Atoms and Implications for an Antideuteron-Based Dark Matter Search
Authors:
T. Aramaki,
S. K. Chan,
W. W. Craig,
L. Fabris,
F. Gahbauer,
C. J. Hailey,
J. E. Koglin,
N. Madden,
K. Mori,
H. T. Yu,
K. P. Ziock
Abstract:
The General AntiParticle Spectrometer (GAPS) is a novel approach for the indirect dark matter search that exploits cosmic antideuterons. GAPS utilizes a distinctive detection method using atomic X-rays and charged particles from the exotic atom as well as the timing, stop** range and dE/dX energy deposit of the incoming particle, which provides excellent antideuteron identification. In anticipat…
▽ More
The General AntiParticle Spectrometer (GAPS) is a novel approach for the indirect dark matter search that exploits cosmic antideuterons. GAPS utilizes a distinctive detection method using atomic X-rays and charged particles from the exotic atom as well as the timing, stop** range and dE/dX energy deposit of the incoming particle, which provides excellent antideuteron identification. In anticipation of a future balloon experiment, an accelerator test was conducted in 2004 and 2005 at KEK, Japan, in order to prove the concept and to precisely measure the X-ray yields of antiprotonic exotic atoms formed with different target materials [1]. The X-ray yields of the exotic atoms with Al and S targets were obtained as ~ 75%, which are higher than were previously assumed in [2]. A simple, but comprehensive cascade model has been developed not only to evaluate the measurement results but also to predict the X-ray yields of the exotic atoms formed with any materials in the GAPS instrument. The cascade model is extendable to any kind of exotic atom (any negatively charged cascading particles with any target materials), and it was compared and validated with other experimental data and cascade models for muonic and antiprotonic exotic atoms. The X-ray yields of the antideuteronic exotic atoms are predicted with a simple cascade model and the sensitivity for the GAPS antideuteron search was estimated for the proposed long duration balloon program [3], which suggests that GAPS has a strong potential to detect antideuterons as a dark matter signature. A GAPS prototype flight (pGAPS) was launched successfully from the JAXA/ISAS balloon facility in Hokkaido, Japan in summer 2012 [4, 5] and a proposed GAPS science flight is to fly from Antarctica in the austral summer of 2017-2018.
△ Less
Submitted 16 August, 2013; v1 submitted 15 March, 2013;
originally announced March 2013.
-
The Prototype GAPS (pGAPS) Experiment
Authors:
S. A. I. Mognet,
T. Aramaki,
N. Bando,
S. E. Boggs,
P. von Doetinchem,
H. Fuke,
F. H. Gahbauer,
C. J. Hailey,
J. E. Koglin,
N. Madden,
K. Mori,
S. Okazaki,
R. A. Ong,
K. M. Perez,
G. Tajiri,
T. Yoshida,
J. Zweerink
Abstract:
The General Antiparticle Spectrometer (GAPS) experiment is a novel approach for the detection of cosmic ray antiparticles. A prototype GAPS experiment (pGAPS) was successfully flown on a high-altitude balloon in June of 2012. The goals of the pGAPS experiment were: to test the operation of lithium drifted silicon (Si(Li)) detectors at balloon altitudes, to validate the thermal model and cooling co…
▽ More
The General Antiparticle Spectrometer (GAPS) experiment is a novel approach for the detection of cosmic ray antiparticles. A prototype GAPS experiment (pGAPS) was successfully flown on a high-altitude balloon in June of 2012. The goals of the pGAPS experiment were: to test the operation of lithium drifted silicon (Si(Li)) detectors at balloon altitudes, to validate the thermal model and cooling concept needed for engineering of a full-size GAPS instrument, and to characterize cosmic ray and X-ray backgrounds. The instrument was launched from the Japan Aerospace Exploration Agency's (JAXA) Taiki Aerospace Research Field in Hokkaido, Japan. The flight lasted a total of 6 hours, with over 3 hours at float altitude (~33 km). Over one million cosmic ray triggers were recorded and all flight goals were met or exceeded.
△ Less
Submitted 7 March, 2013;
originally announced March 2013.
-
The pGAPS experiment: an engineering balloon flight of prototype GAPS
Authors:
Hideyuki Fuke,
Rene A Ong,
Tsuguo Aramaki,
Nobutaka Bando,
Steven E Boggs,
Philip v Doetinchem,
Florian H Gahbauer,
Charles J Hailey,
Jason E Koglin,
Norm Madden,
Samuel Adam I Mognet,
Kaya Mori,
Shun Okazaki,
Kerstin M Perez,
Tetsuya Yoshida,
Jeffrey Zweerink
Abstract:
The General Anti-Particle Spectrometer (GAPS) project is being carried out to search for primary cosmic-ray antiparticles especially for antideuterons produced by cold dark matter. GAPS plans to realize the science observation by Antarctic long duration balloon flights in the late 2010s. In preparation for the Antarctic science flights, an engineering balloon flight using a prototype of the GAPS i…
▽ More
The General Anti-Particle Spectrometer (GAPS) project is being carried out to search for primary cosmic-ray antiparticles especially for antideuterons produced by cold dark matter. GAPS plans to realize the science observation by Antarctic long duration balloon flights in the late 2010s. In preparation for the Antarctic science flights, an engineering balloon flight using a prototype of the GAPS instrument, "pGAPS", was successfully carried out in June 2012 in Japan to verify the basic performance of each GAPS subsystem. The outline of the pGAPS flight campaign is briefly reported.
△ Less
Submitted 24 June, 2013; v1 submitted 2 March, 2013;
originally announced March 2013.
-
IAXO - The International Axion Observatory
Authors:
J. K. Vogel,
F. T. Avignone,
G. Cantatore,
J. M. Carmona,
S. Caspi,
S. A. Cetin,
F. E. Christensen,
A. Dael,
T. Dafni,
M. Davenport,
A. V. Derbin,
K. Desch,
A. Diago,
A. Dudarev,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
J. Galan,
J. A. Garcia,
J. G. Garza,
T. Geralis,
B. Gimeno,
I. Giomataris,
S. Gninenko,
H. Gomez
, et al. (39 additional authors not shown)
Abstract:
The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic f…
▽ More
The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic field volume together with the extensive use of x-ray focusing optics and low background detectors, innovations already successfully tested at CAST. Electron-coupled axions invoked to explain the white dwarf cooling, relic axions, and a large variety of more generic axion-like particles (ALPs) along with other novel excitations at the low-energy frontier of elementary particle physics could provide additional physics motivation for IAXO.
△ Less
Submitted 13 February, 2013;
originally announced February 2013.