-
Ultrasonic Actuation of a Fine-Needle Improves Biopsy Yield
Authors:
Emanuele Perra,
Eetu Lampsijärvi,
Gonçalo Barreto,
Muhammad Arif,
Tuomas Puranen,
Edward Hæggström,
Kenneth P. H. Pritzker,
Heikki J. Nieminen
Abstract:
Despite the ubiquitous use over the past 150 years, the functions of the current medical needle are facilitated only by mechanical shear and cutting by the needle tip,i.e.the lancet. In this study, we demonstrate how nonlinear ultrasonics (NLU) extends the functionality of the medical needle far beyond its present capability. The NLU actions were found to be localized to the proximity of the needl…
▽ More
Despite the ubiquitous use over the past 150 years, the functions of the current medical needle are facilitated only by mechanical shear and cutting by the needle tip,i.e.the lancet. In this study, we demonstrate how nonlinear ultrasonics (NLU) extends the functionality of the medical needle far beyond its present capability. The NLU actions were found to be localized to the proximity of the needle tip, the SonoLancet, but the effects extend several millimeters from the physical needle boundary. The observed nonlinear phenomena, transient cavitation, fluid streams, translation of micro- and nanoparticles and atomization, were quantitatively characterized. In the fine-needle biopsy application, the SonoLancet contributed to obtaining tissue cores with increase in tissue yield by 3-6x in different tissue types compared to conventional needle biopsy technique using the same 21G needle. In conclusion, the SonoLancet could be of interest to several other medical applications, including drug or gene delivery, cell modulation, and minimally invasive surgical procedures.
△ Less
Submitted 9 March, 2021; v1 submitted 30 June, 2020;
originally announced June 2020.
-
Radiation Monitor RADMON aboard Aalto-1 CubeSat: First results
Authors:
Jan Gieseler,
Philipp Oleynik,
Heli Hietala,
Rami Vainio,
Hannu-Pekka Hedman,
Juhani Peltonen,
Arttu Punkkinen,
Risto Punkkinen,
Tero Säntti,
Edward Hæggström,
Jaan Praks,
Petri Niemelä,
Bagus Riwanto,
Nemanja Jovanovic,
M. Rizwan Mughal
Abstract:
The Radiation Monitor (RADMON) on-board Aalto-1 CubeSat is an energetic particle detector that fulfills the requirements of small size, low power consumption and low budget. Aalto-1 was launched on 23 June 2017 to a sun-synchronous polar orbit with 97.4° inclination and an average altitude of somewhat above 500 km. RADMON has been measuring integral particle intensities from October 2017 to May 20…
▽ More
The Radiation Monitor (RADMON) on-board Aalto-1 CubeSat is an energetic particle detector that fulfills the requirements of small size, low power consumption and low budget. Aalto-1 was launched on 23 June 2017 to a sun-synchronous polar orbit with 97.4° inclination and an average altitude of somewhat above 500 km. RADMON has been measuring integral particle intensities from October 2017 to May 2018 with electron energies starting at low-MeV and protons from 10 MeV upwards. In this paper, we present first electron and proton intensity maps obtained over the mission period. In addition, the response of RADMON measurements to magnetospheric dynamics are analyzed, and the electron observations are compared with corresponding measurements by the PROBA-V/EPT mission. Finally, the we describe the RADMON data set, which is made publicly available.
△ Less
Submitted 18 November, 2019;
originally announced November 2019.
-
Calibration of RADMON Radiation Monitor Onboard Aalto-1 CubeSat
Authors:
Philipp Oleynik,
Rami Vainio,
Arttu Punkkinen,
Oleksiy Dudnik,
Jan Gieseler,
Hannu-Pekka Hedman,
Heli Hietala,
Edward Hæggström,
Petri Niemelä,
Juhani Peltonen,
Jaan Praks,
Risto Punkkinen,
Tero Säntti,
Eino Valtonen
Abstract:
RADMON is a small radiation monitor designed and assembled by students of the University of Turku and the University of Helsinki. It is flown on-board Aalto-1, a 3-unit CubeSat in low Earth orbit at about 500 km altitude. The detector unit of the instrument consists of two detectors, a Si solid-state detector and a CsI(Tl) scintillator, and utilizes the \textDelta{E}-E technique to determine the t…
▽ More
RADMON is a small radiation monitor designed and assembled by students of the University of Turku and the University of Helsinki. It is flown on-board Aalto-1, a 3-unit CubeSat in low Earth orbit at about 500 km altitude. The detector unit of the instrument consists of two detectors, a Si solid-state detector and a CsI(Tl) scintillator, and utilizes the \textDelta{E}-E technique to determine the total energy and species of each particle hitting the detector. We present the results of the on-ground and in-flight calibration campaigns of the instrument, as well as the characterization of its response through extensive simulations within the Geant4 framework. The overall energy calibration margin achieved is about 5\%. The full instrument response to protons and electrons is presented and the issue of proton contamination of the electron channels is quantified and discussed.
△ Less
Submitted 18 November, 2019;
originally announced November 2019.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
E-sail test payload of ESTCube-1 nanosatellite
Authors:
Jouni Envall,
Pekka Janhunen,
Petri Toivanen,
Mihkel Pajusalu,
Erik Ilbis,
Jaanus Kalde,
Matis Averin,
Henri Kuuste,
Kaspars Laizans,
Viljo Allik,
Timo Rauhala,
Henri Seppänen,
Sergiy Kiprich,
Jukka Ukkonen,
Edward Haeggström,
Taneli Kalvas,
Olli Tarvainen,
Janne Kauppinen,
Antti Nuottajärvi,
Hannu Koivisto
Abstract:
The scientific mission of ESTCube-1, launched in May 2013, is to measure the Electric solar wind sail (E-sail) force in orbit. The experiment is planned to push forward the development of E-sail, a propulsion method recently invented at the Finnish Meteorological Institute. E-sail is based on extracting momentum from the solar wind plasma flow by using long thin electrically charged tethers. ESTCu…
▽ More
The scientific mission of ESTCube-1, launched in May 2013, is to measure the Electric solar wind sail (E-sail) force in orbit. The experiment is planned to push forward the development of E-sail, a propulsion method recently invented at the Finnish Meteorological Institute. E-sail is based on extracting momentum from the solar wind plasma flow by using long thin electrically charged tethers. ESTCube-1 is equipped with one such tether, together with hardware capable of deploying and charging it. At the orbital altitude of ESTCube-1 (660--680~km) there is no solar wind present. Instead, ESTCube-1 shall observe the interaction between the charged tether and the ionospheric plasma. The ESTCube-1 payload uses a 10-meter, partly two-filament E-sail tether and a motorized reel on which it is stored. The tether shall be deployed from a spinning satellite with the help of centrifugal force. An additional mass is added at the tip of the tether to assist with the deployment. During E-sail experiment the tether shall be charged to 500~V potential. Both positive and negative voltages shall be experimented with. The voltage is provided by a dedicated high voltage source and delivered to the tether through a slip ring contact. When the negative voltage is applied to the tether, the satellite body is expected to attract electron flow capable of compensating for the ion flow, which runs to the tether from the surrounding plasma. With the positive voltage applied, onboard cold cathode electron guns are used to remove excess electrons to maintain the positive voltage of the tether. In this paper we present the design and structure of the tether payload of ESTCube-1.
△ Less
Submitted 28 April, 2014;
originally announced April 2014.