-
Imaging of chemical kinetics at the water-water interface in a free-flowing liquid flat-jet
Authors:
H. Christian Schewe,
Bruno Credidio,
Aaron M. Ghrist,
Sebastian Malerz,
Christian Ozga,
André Knie,
Henrik Haak,
Gerard Meijer,
Bernd Winter,
Andreas Osterwalder
Abstract:
We present chemical kinetics measurements of the luminol oxydation chemiluminescence reaction at the interface between two aqueous solutions, using liquid jet technology. Free-flowing iquid microjets are a relatively recent development that has found its way into a growing number of applications in spectroscopy and dynamics. A variant thereof, called flat-jet, is obtained when two cylindrical jets…
▽ More
We present chemical kinetics measurements of the luminol oxydation chemiluminescence reaction at the interface between two aqueous solutions, using liquid jet technology. Free-flowing iquid microjets are a relatively recent development that has found its way into a growing number of applications in spectroscopy and dynamics. A variant thereof, called flat-jet, is obtained when two cylindrical jets of a liquid are crossed, leading to a chain of planar leaf-shaped structures of the flowing liquid. We here show that in the first leaf of this chain the fluids do not exhibit turbulent mixing, providing a clean interface between the liquids from the im**ing jets. We also show, using the example of the luminol chemiluminescence reaction, how this setup can be used to obtain kinetics information from friction-less flow and by circumventing the requirement for rapid mixing but by intentionally suppressing all turbulent mixing and instead relying on diffusion.
△ Less
Submitted 13 January, 2022;
originally announced January 2022.
-
A setup for studies of photoelectron circular dichroism from chiral molecules in aqueous solution
Authors:
Sebastian Malerz,
Henrik Haak,
Florian Trinter,
Anne B. Stephansen,
Claudia Kolbeck,
Marvin Pohl,
Uwe Hergenhahn,
Gerard Meijer,
Bernd Winter
Abstract:
We present a unique experimental design that enables the measurement of photoelectron circular dichroism (PECD) from chiral molecules in aqueous solution. The effect is revealed from the intensity difference of photoelectron emission into a backward-scattering angle relative to the photon propagation direction when ionizing with circularly polarized light of different helicity. This leads to asymm…
▽ More
We present a unique experimental design that enables the measurement of photoelectron circular dichroism (PECD) from chiral molecules in aqueous solution. The effect is revealed from the intensity difference of photoelectron emission into a backward-scattering angle relative to the photon propagation direction when ionizing with circularly polarized light of different helicity. This leads to asymmetries (normalized intensity differences) that depend on the handedness of the chiral sample and exceed the ones in conventional dichroic mechanisms by orders of magnitude. The asymmetry is largest for photon energies within several electron volts above the ionization threshold. A primary aim is to explore the effect of hydration on PECD. The modular and flexible design of our experimental setup EASI (Electronic structure from Aqueous Solutions and Interfaces) also allows for detection of more common photoelectron angular distributions (PADs), requiring distinctively different detection geometries, and typically using linearly polarized light. A microjet is used for liquid-sample delivery. We describe EASI's technical features and present two selected experimental results, one based on synchrotron-light measurements and the other performed in the laboratory, using monochromatized He-II $α$ radiation. The former demonstrates the principal effectiveness of PECD detection, illustrated for prototypic gas-phase fenchone. We also discuss the first data from liquid fenchone. In the second example we present valence photoelectron spectra from liquid water and NaI aqueous solution, here obtained from a planar-surface microjet (flatjet). This new development features a more favorable symmetry for angle-dependent photoelectron measurements.
△ Less
Submitted 13 December, 2021; v1 submitted 29 September, 2021;
originally announced September 2021.
-
A New Design for a Traveling-Wave Zeeman Decelerator: II. Experiment
Authors:
Tomislav Damjanovic,
Stefan Willitsch,
Nicolas Vanhaecke,
Henrik Haak,
Gerard Meijer,
JeanPaul Cromieres,
Dongdong Zhang
Abstract:
A novel traveling-wave Zeeman decelerator based on a double-helix coil geometry capable of decelerating paramagnetic molecules with high efficiency is presented. Moving magnetic traps are generated by applying time-dependent currents through the decelerator coils. Paramagnetic molecules in low-field-seeking Zeeman states are confined inside the moving traps which are decelerated to lower forward v…
▽ More
A novel traveling-wave Zeeman decelerator based on a double-helix coil geometry capable of decelerating paramagnetic molecules with high efficiency is presented. Moving magnetic traps are generated by applying time-dependent currents through the decelerator coils. Paramagnetic molecules in low-field-seeking Zeeman states are confined inside the moving traps which are decelerated to lower forward velocities. As a prototypical example, we demonstrate the deceleration of OH radicals from an initial velocity of 445 m/s down to various final velocities. The experimental results are analyzed and numerically reproduced with the help of trajectory simulations confirming the phase-space stability and efficiency of the deceleration of the molecules in the new device.
△ Less
Submitted 5 August, 2021;
originally announced August 2021.
-
A New Design for a Traveling-Wave Zeeman Decelerator: I. Theory
Authors:
Tomislav Damjanovic,
Stefan Willitsch,
Nicolas Vanhaecke,
Henrik Haak,
Gerard Meijer,
JeanPaul Cromieres,
Dongdong Zhang
Abstract:
The concept of a novel traveling wave Zeeman deccelerator based on a double-helix wire geometry capable of decelerating paramagnetic species with high efficiency is presented. A moving magnetic trap is created by running time-dependent currents through the decelerator coils. Paramagnetic species in low-field-seeking Zeeman states are confined in the moving traps and transported to the end of the d…
▽ More
The concept of a novel traveling wave Zeeman deccelerator based on a double-helix wire geometry capable of decelerating paramagnetic species with high efficiency is presented. A moving magnetic trap is created by running time-dependent currents through the decelerator coils. Paramagnetic species in low-field-seeking Zeeman states are confined in the moving traps and transported to the end of the decelerator with programmable velocities. Here, we present the theoretical foundations underlying the working principle of the traveling-trap decelerator. Using trajectory simulations, we characterise the performance of the new device and explore the conditions for phase-space stability of the transported molecules.
△ Less
Submitted 5 August, 2021;
originally announced August 2021.
-
A traveling wave decelerator for neutral polar molecules
Authors:
Samuel A. Meek,
Maxwell F. Parsons,
Georg Heyne,
Viktor Platschkowski,
Henrik Haak,
Gerard Meijer,
Andreas Osterwalder
Abstract:
Recently, a decelerator for neutral polar molecules has been presented that operates on the basis of macroscopic, three-dimensional, traveling electrostatic traps (Osterwalder et al., Phys. Rev. A 81, 051401 (2010)). In the present paper, a complete description of this decelerator is given, with emphasis on the electronics and the mechanical design. Experimental results showing the transverse velo…
▽ More
Recently, a decelerator for neutral polar molecules has been presented that operates on the basis of macroscopic, three-dimensional, traveling electrostatic traps (Osterwalder et al., Phys. Rev. A 81, 051401 (2010)). In the present paper, a complete description of this decelerator is given, with emphasis on the electronics and the mechanical design. Experimental results showing the transverse velocity distributions of guided molecules are shown and compared to trajectory simulations. An assessment of non-adiabatic losses is made by comparing the deceleration signals from 13-CO with those from 12-CO and with simulated signals.
△ Less
Submitted 27 July, 2011;
originally announced July 2011.
-
An electrostatic elliptical mirror for neutral polar molecules
Authors:
A. Isabel González Flórez,
Samuel A. Meek,
Henrik Haak,
Horst Conrad,
Gabriele Santambrogio,
Gerard Meijer
Abstract:
Focusing optics for neutral molecules finds application in sha** and steering molecular beams. Here we present an electrostatic elliptical mirror for polar molecules consisting of an array of microstructured gold electrodes deposited on a glass substrate. Alternating positive and negative voltages applied to the electrodes create a repulsive potential for molecules in low-field-seeking states. T…
▽ More
Focusing optics for neutral molecules finds application in sha** and steering molecular beams. Here we present an electrostatic elliptical mirror for polar molecules consisting of an array of microstructured gold electrodes deposited on a glass substrate. Alternating positive and negative voltages applied to the electrodes create a repulsive potential for molecules in low-field-seeking states. The equipotential lines are parallel to the substrate surface, which is bent in an elliptical shape. The mirror is characterized by focusing a beam of metastable CO molecules and the results are compared to the outcome of trajectory simulations.
△ Less
Submitted 29 March, 2011;
originally announced March 2011.
-
Rotational-state-specific guiding of large molecules
Authors:
Stephan Putzke,
Frank Filsinger,
Henrik Haak,
Jochen Küpper,
Gerard Meijer
Abstract:
A beam of polar molecules can be focused and transported through an ac electric quadrupole guide. At a given ac frequency, the transmission of the guide depends on the mass-to-dipole-moment (m/\textmu) ratio of the molecular quantum state. Here we present a detailed characterization of the m/\textmu selector, using a pulsed beam of benzonitrile (C$_6$H$_5$CN) molecules in combination with rotation…
▽ More
A beam of polar molecules can be focused and transported through an ac electric quadrupole guide. At a given ac frequency, the transmission of the guide depends on the mass-to-dipole-moment (m/\textmu) ratio of the molecular quantum state. Here we present a detailed characterization of the m/\textmu selector, using a pulsed beam of benzonitrile (C$_6$H$_5$CN) molecules in combination with rotational quantum state resolved detection. The arrival time distribution as well as the transverse velocity distribution of the molecules exiting the selector are measured as a function of ac frequency. The \textmu/$Δ$\textmu resolution of the selector can be controlled by the applied ac waveforms and a value of up to 20 can be obtained with the present setup. This is sufficient to exclusively transmit molecules in the absolute ground state of benzonitrile, or rather in quantum states that have the same m/\textmu value as the ground state. The operation characteristics of the m/\textmu selector are in quantitative agreement with the outcome of trajectory simulations.
△ Less
Submitted 25 March, 2011;
originally announced March 2011.
-
Slowing polar molecules using a wire Stark decelerator
Authors:
Adela Marian,
Henrik Haak,
Peter Geng,
Gerard Meijer
Abstract:
We have designed and implemented a new Stark decelerator based on wire electrodes, which is suitable for ultrahigh vacuum applications. The 100 deceleration stages are fashioned out of 0.6 mm diameter tantalum and the array's total length is 110 mm, approximately 10 times smaller than a conventional Stark decelerator with the same number of electrode pairs. Using the wire decelerator, we have remo…
▽ More
We have designed and implemented a new Stark decelerator based on wire electrodes, which is suitable for ultrahigh vacuum applications. The 100 deceleration stages are fashioned out of 0.6 mm diameter tantalum and the array's total length is 110 mm, approximately 10 times smaller than a conventional Stark decelerator with the same number of electrode pairs. Using the wire decelerator, we have removed more than 90% of the kinetic energy from metastable CO molecules in a beam.
△ Less
Submitted 27 September, 2010; v1 submitted 27 April, 2010;
originally announced April 2010.
-
Deceleration of neutral molecules in macroscopic traveling traps
Authors:
Andreas Osterwalder,
Samuel A. Meek,
Georg Hammer,
Henrik Haak,
Gerard Meijer
Abstract:
A new type of decelerator is presented where polar neutral molecules are guided and decelerated using the principle of traveling electric potential wells, such that molecules are confined in stable three-dimensional traps throughout. This new decelerator is superior to the best currently operational decelerator (Scharfenberg et al., Phys.Rev.A 79, 023410(2009)), providing a substantially larger…
▽ More
A new type of decelerator is presented where polar neutral molecules are guided and decelerated using the principle of traveling electric potential wells, such that molecules are confined in stable three-dimensional traps throughout. This new decelerator is superior to the best currently operational decelerator (Scharfenberg et al., Phys.Rev.A 79, 023410(2009)), providing a substantially larger acceptance even at higher accelerations. The mode of operation is described and experimentally demonstrated by guiding and decelerating CO molecules.
△ Less
Submitted 18 March, 2010; v1 submitted 17 November, 2009;
originally announced November 2009.
-
Operation of a Stark decelerator with optimum acceptance
Authors:
Ludwig Scharfenberg,
Henrik Haak,
Gerard Meijer,
Sebastiaan Y. T. van de Meerakker
Abstract:
With a Stark decelerator, beams of neutral polar molecules can be accelerated, guided at a constant velocity, or decelerated. The effectiveness of this process is determined by the 6D volume in phase space from which molecules are accepted by the Stark decelerator. Couplings between the longitudinal and transverse motion of the molecules in the decelerator can reduce this acceptance. These coupl…
▽ More
With a Stark decelerator, beams of neutral polar molecules can be accelerated, guided at a constant velocity, or decelerated. The effectiveness of this process is determined by the 6D volume in phase space from which molecules are accepted by the Stark decelerator. Couplings between the longitudinal and transverse motion of the molecules in the decelerator can reduce this acceptance. These couplings are nearly absent when the decelerator operates such that only every third electric field stage is used for deceleration, while extra transverse focusing is provided by the intermediate stages. For many applications, the acceptance of a Stark decelerator in this so-called $s=3$ mode significantly exceeds that of a decelerator in the conventionally used ($s=1$) mode. This has been experimentally verified by passing a beam of OH radicals through a 2.6 meter long Stark decelerator. The experiments are in quantitative agreement with the results of trajectory calculations, and can qualitatively be explained with a simple model for the 6D acceptance. These results imply that the 6D acceptance of a Stark decelerator in the $s=3$ mode of operation approaches the optimum value, i.e. the value that is obtained when any couplings are neglected.
△ Less
Submitted 25 July, 2008;
originally announced July 2008.
-
Alternating gradient focusing and deceleration of large molecules
Authors:
Kirstin Wohlfart,
Fabian Grätz,
Frank Filsinger,
Henrik Haak,
Gerard Meijer,
Jochen Küpper
Abstract:
We have focused and decelerated benzonitrile (C$_7$H$_5$N) molecules from a molecular beam, using an array of time-varying inhomogeneous electric fields in alternating gradient configuration. Benzonitrile is prototypical for large asymmetric top molecules that exhibit rich rotational structure and a high density of states. At the rotational temperature of 3.5 K in the pulsed molecular beam, many…
▽ More
We have focused and decelerated benzonitrile (C$_7$H$_5$N) molecules from a molecular beam, using an array of time-varying inhomogeneous electric fields in alternating gradient configuration. Benzonitrile is prototypical for large asymmetric top molecules that exhibit rich rotational structure and a high density of states. At the rotational temperature of 3.5 K in the pulsed molecular beam, many rotational states are populated. Benzonitrile molecules in their absolute ground state are decelerated from 320 m/s to 289 m/s, and similar changes in velocity are obtained for excited rotational states. All measurements agree well with the outcome of trajectory calculations. These experiments demonstrate that such large polyatomic molecules are amenable to the powerful method of Stark deceleration.
△ Less
Submitted 5 March, 2008;
originally announced March 2008.
-
Compact in-place gate valve for molecular beam experiments
Authors:
Jochen Küpper,
Henrik Haak,
Kirstin Wohlfart,
Gerard Meijer
Abstract:
A high vacuum gate valve for skimmed molecular beam experiments is described. It is designed with a very short extent of only 10 mm along the molecular beam axis to minimize the distance between the molecular beam source and the experiment to provide the maximum molecular flux to the experiment. At the same time it provides free space on both sides of the skimmer to not disturb the supersonic ex…
▽ More
A high vacuum gate valve for skimmed molecular beam experiments is described. It is designed with a very short extent of only 10 mm along the molecular beam axis to minimize the distance between the molecular beam source and the experiment to provide the maximum molecular flux to the experiment. At the same time it provides free space on both sides of the skimmer to not disturb the supersonic expansion in front of the skimmer, to give optical access to the full distance between beam source and skimmer, and to allow for placing electrostatic devices very close behind the skimmer. The gate valve allows to maintain high vacuum conditions (10^{-8} mbar) in the experimental chamber while the source chamber is brought up to atmospheric pressure for modifications or maintenance. The valve can be operated from outside the vacuum chamber while maintaining vacuum conditions in all chambers.
△ Less
Submitted 10 February, 2006;
originally announced February 2006.