-
Search for fractionally charged particles with CUORE
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (95 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using th…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using the first tonne-year of CUORE's exposure, we perform a search for hypothesized fractionally charged particles (FCPs), which are well-motivated by various Standard Model extensions and would have suppressed interactions with matter. No excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges between $e/24-e/5$ at 90\% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale sub-Kelvin detectors to diverse signatures of new physics.
△ Less
Submitted 18 June, 2024;
originally announced June 2024.
-
Data-driven background model for the CUORE experiment
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (93 additional authors not shown)
Abstract:
We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth explo…
▽ More
We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth exploration of both spatial and time dependence of backgrounds. We achieve high sensitivity to both bulk and surface activities of the materials of the setup, detecting levels as low as 10 nBq kg$^{-1}$ and 0.1 nBq cm$^{-2}$, respectively. We compare the contamination levels we extract from the background model with prior radio-assay data, which informs future background risk mitigation strategies. The results of this background model play a crucial role in constructing the background budget for the CUPID experiment as it will exploit the same CUORE infrastructure.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
DoubleTES detectors to investigate the CRESST low energy background: results from above-ground prototypes
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (33 additional authors not shown)
Abstract:
In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known as the low energy excess (LEE). The CRESST experiment utilises advanced cryogenic detectors constructed with different types of crystals equipped with Transition Edge Sensors (TESs) to measure signals of nuclear recoils i…
▽ More
In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known as the low energy excess (LEE). The CRESST experiment utilises advanced cryogenic detectors constructed with different types of crystals equipped with Transition Edge Sensors (TESs) to measure signals of nuclear recoils induced by the scattering of dark matter particles in the detector. In CRESST, this low energy background manifests itself as a steeply rising population of events below 200 eV. A novel detector design named doubleTES using two identical TESs on the target crystal was studied to investigate the hypothesis that the events are sensor-related. We present the first results from two such modules, demonstrating their ability to differentiate between events originating from the crystal's bulk and those occurring in the sensor or in its close proximity.
△ Less
Submitted 3 April, 2024;
originally announced April 2024.
-
LUCE: A milli-Kelvin calorimeter experiment to study the electron capture of 176Lu
Authors:
Shihong Fu,
Giovanni Benato,
Carlo Bucci,
Paolo Gorla,
Pedro V. Guillaumon,
Jiang Li,
Serge Nagorny,
Francesco Nozzoli,
Lorenzo Pagnanini,
Andrei Puiu,
Matthew Stukel
Abstract:
The LUCE (LUtetium sCintillation Experiment) project will search for the 176Lu electron capture based on a milli-Kelvin calorimetric approach. This decay is of special interest in the field of nuclear structure, with implications for the s-process and for a better comprehension of the nuclear matrix elements of neutrinoless double beta decay (0ν\b{eta}\b{eta}) and two-neutrino double beta decay (2…
▽ More
The LUCE (LUtetium sCintillation Experiment) project will search for the 176Lu electron capture based on a milli-Kelvin calorimetric approach. This decay is of special interest in the field of nuclear structure, with implications for the s-process and for a better comprehension of the nuclear matrix elements of neutrinoless double beta decay (0ν\b{eta}\b{eta}) and two-neutrino double beta decay (2ν\b{eta}\b{eta}). Possible impacts also include the development of a new class of coherent elastic neutrino-nucleus scattering (CEνNS) and spin-dependent (independent) dark matter detectors. We report on the current status and design of a novel detector cryogenic-module for the measurement of the electron capture and detail a future measurement plan.
△ Less
Submitted 8 November, 2023;
originally announced January 2024.
-
Optimal operation of cryogenic calorimeters through deep reinforcement learning
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an…
▽ More
Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an expert. In our work, we automated the procedure with reinforcement learning in two settings. First, we trained on a simulation of the response of three CRESST detectors used as a virtual reinforcement learning environment. Second, we trained live on the same detectors operated in the CRESST underground setup. In both cases, we were able to optimize a standard detector as fast and with comparable results as human experts. Our method enables the tuning of large-scale cryogenic detector setups with minimal manual interventions.
△ Less
Submitted 25 November, 2023;
originally announced November 2023.
-
Detector development for the CRESST experiment
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (33 additional authors not shown)
Abstract:
Recently low-mass dark matter direct searches have been hindered by a low energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment, this signal is characterised by a significant increase of events below 200 eV. As the origin of this background is still unknown, it became necessary to develop new detector designs to reach a better understanding of t…
▽ More
Recently low-mass dark matter direct searches have been hindered by a low energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment, this signal is characterised by a significant increase of events below 200 eV. As the origin of this background is still unknown, it became necessary to develop new detector designs to reach a better understanding of the observations. Within the CRESST collaboration, three new different detector layouts have been developed and they are presented in this contribution.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
Light Dark Matter Search Using a Diamond Cryogenic Detector
Authors:
CRESST Collaboration,
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum
, et al. (34 additional authors not shown)
Abstract:
Diamond operated as a cryogenic calorimeter is an excellent target for direct detection of low-mass dark matter candidates. Following the realization of the first low-threshold cryogenic detector that uses diamond as absorber for astroparticle physics applications, we now present the resulting exclusion limits on the elastic spin-independent interaction cross-section of dark matter with diamond. W…
▽ More
Diamond operated as a cryogenic calorimeter is an excellent target for direct detection of low-mass dark matter candidates. Following the realization of the first low-threshold cryogenic detector that uses diamond as absorber for astroparticle physics applications, we now present the resulting exclusion limits on the elastic spin-independent interaction cross-section of dark matter with diamond. We measured two 0.175 g CVD (Chemical Vapor Deposition) diamond samples, each instrumented with a W-TES. Thanks to the energy threshold of just 16.8 eV of one of the two detectors, we set exclusion limits on the elastic spin-independent interaction of dark matter particles with carbon nuclei down to dark matter masses as low as 0.122 GeV/c2. This work shows the scientific potential of cryogenic detectors made from diamond and lays the foundation for the use of this material as target for direct detection dark matter experiments.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
High-Dimensional Bayesian Likelihood Normalisation for CRESST's Background Model
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Jeskovsky,
J. Jochum,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, base…
▽ More
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, based on Geant4 simulations, are normalised via a Bayesian likelihood fit to experimental background data. Contrary to our previous work, no assumption of partial secular equilibrium is required, which results in a more robust and versatile applicability. Furthermore, considering the correlation between all background components allows us to explain 82.7% of the experimental background within [1 keV, 40 keV], an improvement of 18.6% compared to our previous method.
△ Less
Submitted 19 July, 2023;
originally announced July 2023.
-
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
Authors:
CUPID collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Campani,
C. Capelli
, et al. (154 additional authors not shown)
Abstract:
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of…
▽ More
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a $^{133}$Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to $γ$ detectors of any technology in this energy range.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments
Authors:
CUPID,
CROSS collaborations,
:,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci
, et al. (160 additional authors not shown)
Abstract:
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied…
▽ More
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, $μ$Bq/kg, level of the LMO crystals radioactive contamination by $^{228}$Th and $^{226}$Ra.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Observation of a low energy nuclear recoil peak in the neutron calibration data of the CRESST-III Experiment
Authors:
CRESST Collaboration,
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
S. Gerster,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff
, et al. (36 additional authors not shown)
Abstract:
New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Re…
▽ More
New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Recently, a new calibration method based on the radiative neutron capture on $^{182}$W with subsequent de-excitation via single $γ$-emission leading to a nuclear recoil peak at 112 eV was proposed. The CRESST-III dark matter search operated several CaWO$_{4}$-based detector modules with detection thresholds below 100 eV in the past years. We report the observation of a peak around the expected energy of 112 eV in the data of three different detector modules recorded while irradiated with neutrons from different AmBe calibration sources. We compare the properties of the observed peaks with Geant-4 simulations and assess the prospects of using this for the energy calibration of CRESST-III detectors.
△ Less
Submitted 25 July, 2023; v1 submitted 27 March, 2023;
originally announced March 2023.
-
Towards an automated data cleaning with deep learning in CRESST
Authors:
G. Angloher,
S. Banik,
D. Bartolot,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
S. Gerster,
P. Gorla,
P. V. Guillaumon,
S. Gupta
, et al. (40 additional authors not shown)
Abstract:
The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a careful cleaning process to avoid wrongly reconstructed recoil energies caused by pile-up and read-out artefacts. We frame this process as a time series classification task and propose to automate it with neural networks. Wit…
▽ More
The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a careful cleaning process to avoid wrongly reconstructed recoil energies caused by pile-up and read-out artefacts. We frame this process as a time series classification task and propose to automate it with neural networks. With a data set of over one million labeled records from 68 detectors, recorded between 2013 and 2019 by CRESST, we test the capability of four commonly used neural network architectures to learn the data cleaning task. Our best performing model achieves a balanced accuracy of 0.932 on our test set. We show on an exemplary detector that about half of the wrongly predicted events are in fact wrongly labeled events, and a large share of the remaining ones have a context-dependent ground truth. We furthermore evaluate the recall and selectivity of our classifiers with simulated data. The results confirm that the trained classifiers are well suited for the data cleaning task.
△ Less
Submitted 7 January, 2023; v1 submitted 1 November, 2022;
originally announced November 2022.
-
Characterization of a kg-scale archaeological lead-based cryogenic detectors for the RES-NOVA experiment
Authors:
J. W. Beeman,
G. Benato,
C. Bucci,
L. Canonica,
P. Carniti,
E. Celi,
M. Clemenza,
A. D'Addabbo,
F. A. Danevich,
S. Di Domizio,
S. Di Lorenzo,
O. M. Dubovik,
N. Ferreiro Iachellini,
F. Ferroni,
E. Fiorini,
S. Fu,
A. Garai,
S. Ghislandi,
L. Gironi,
P. Gorla,
C. Gotti,
P. V. Guillaumon,
D. L. Helis,
G. P. Kovtun,
M. Mancuso
, et al. (19 additional authors not shown)
Abstract:
One of the most energetic events in the Universe are core-collapse Supernovae (SNe), where almost all the star's binding energy is released as neutrinos. These particles are direct probes of the processes occurring in the stellar core and provide unique insights into the gravitational collapse. RES-NOVA will revolutionize how we detect neutrinos from astrophysical sources, by deploying the first t…
▽ More
One of the most energetic events in the Universe are core-collapse Supernovae (SNe), where almost all the star's binding energy is released as neutrinos. These particles are direct probes of the processes occurring in the stellar core and provide unique insights into the gravitational collapse. RES-NOVA will revolutionize how we detect neutrinos from astrophysical sources, by deploying the first ton-scale array of cryogenic detectors made from archaeological lead. Pb offers the highest neutrino interaction cross-section via coherent elastic neutrino-nucleus scattering (CE$ν$NS). Such process will enable RES-NOVA to be equally sensitive to all neutrino flavors. For the first time, we propose to use archaeological Pb as sensitive target material in order to achieve an ultra-low background level in the region of interest (\textit{O}(1keV)). All these features make possible the deployment of the first cm-scale neutrino telescope for the investigation of astrophysical sources. In this contribution, we will characterize the radiopurity level and the performance of a small-scale proof-of-principle detector of RES-NOVA, consisting in a PbWO$_4$ crystal made from archaeological-Pb operated as cryogenic detector.
△ Less
Submitted 14 November, 2022; v1 submitted 29 May, 2022;
originally announced June 2022.
-
Radiopurity of a kg-scale PbWO$_4$ cryogenic detector produced from archaeological Pb for the RES-NOVA experiment
Authors:
J. W. Beeman,
G. Benato,
C. Bucci,
L. Canonica,
P. Carniti,
E. Celi,
M. Clemenza,
A. D'Addabbo,
F. A. Danevich,
S. Di Domizio,
S. Di Lorenzo,
O. M. Dubovik,
N. Ferreiro Iachellini,
F. Ferroni,
E. Fiorini,
S. Fu,
A. Garai,
S. Ghislandi,
L. Gironi,
P. Gorla,
C. Gotti,
P. V. Guillaumon,
D. L. Helis,
G. P. Kovtun,
M. Mancuso
, et al. (19 additional authors not shown)
Abstract:
RES-NOVA is a newly proposed experiment for the detection of neutrinos from astrophysical sources, mainly Supernovae, using an array of cryogenic detectors made of PbWO$_4$ crystals produced from archaeological Pb. This unconventional material, characterized by intrinsic high radiopurity, enables to achieve low-background levels in the region of interest for the neutrino detection via Coherent Ela…
▽ More
RES-NOVA is a newly proposed experiment for the detection of neutrinos from astrophysical sources, mainly Supernovae, using an array of cryogenic detectors made of PbWO$_4$ crystals produced from archaeological Pb. This unconventional material, characterized by intrinsic high radiopurity, enables to achieve low-background levels in the region of interest for the neutrino detection via Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS). This signal lies at the detector energy threshold, O(1 keV), and it is expected to be hidden by naturally occurring radioactive contaminants of the crystal absorber. Here, we present the results of a radiopurity assay on a 0.84 kg PbWO$_4$ crystal produced from archaeological Pb operated as a cryogenic detector. The crystal internal radioactive contaminations are: $^{232}$Th $<$40 $μ$Bq/kg, $^{238}$U $<$30 $μ$Bq/kg, $^{226}$Ra 1.3 mBq/kg and $^{210}$Pb 22.5 mBq/kg. We present also a background projection for the final experiment and possible mitigation strategies for further background suppression. The achieved results demonstrate the feasibility of realizing this new class of detectors.
△ Less
Submitted 28 March, 2022; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Optimization of the first CUPID detector module
Authors:
CUPID collaboration,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli
, et al. (153 additional authors not shown)
Abstract:
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the…
▽ More
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.
△ Less
Submitted 13 February, 2022;
originally announced February 2022.