-
Investigating Neutron Scattering in a Spherical Proportional Counter: A Tabletop Experiment
Authors:
N. Panchal,
L. Balogh,
J. -F. Caron,
G. Giroux,
P. Gros
Abstract:
In this paper, we report on a tabletop experiment studying neutron scattering in a Spherical Proportional Counter using an Am-Be source. Systematic studies were carried out to investigate the effect of gas mixture, pressure, operating voltage, and sphere size on the drift time-rise time relationship of the signal in a spherical proportional counter. Our experimental results showed good agreement w…
▽ More
In this paper, we report on a tabletop experiment studying neutron scattering in a Spherical Proportional Counter using an Am-Be source. Systematic studies were carried out to investigate the effect of gas mixture, pressure, operating voltage, and sphere size on the drift time-rise time relationship of the signal in a spherical proportional counter. Our experimental results showed good agreement with MagBoltz simulations. These findings are a crucial step towards measuring the quenching factor in gases using a neutron beam for the New Experiments With Spheres-Gas (NEWS-G) experiment and has important implications for the development of neutron detection techniques and their potential applications in nuclear and particle physics.
△ Less
Submitted 13 February, 2024;
originally announced February 2024.
-
A novel technique for the measurement of the avalanche fluctuations of a GEM stack using a gating foil
Authors:
M. Kobayashi,
K. Yumino,
T. Ogawa,
A. Shoji,
Y. Aoki,
K. Ikematsu,
P. Gros,
T. Kawaguchi,
D. Arai,
M. Iwamura,
K. Katsuki,
A. Koto,
M. Yoshikai,
K. Fujii,
T. Fusayasu,
Y. Kato,
S. Kawada,
T. Matsuda,
T. Mizuno,
J. Nakajima,
S. Narita,
K. Negishi,
H. Qi,
R. D. Settles,
A. Sugiyama
, et al. (4 additional authors not shown)
Abstract:
We have developed a novel technique for the measurement of the size of avalanche fluctuations of gaseous detectors using a gating device (gating foil) prepared for the time projection chamber in the international linear collider experiment (ILD-TPC). In addition to the gating function, the gating foil is capable of controlling the average fraction of drift electrons detected after gas amplificatio…
▽ More
We have developed a novel technique for the measurement of the size of avalanche fluctuations of gaseous detectors using a gating device (gating foil) prepared for the time projection chamber in the international linear collider experiment (ILD-TPC). In addition to the gating function, the gating foil is capable of controlling the average fraction of drift electrons detected after gas amplification. The signal charge width and shape (skewness) for electron-ion pairs created by a pulsed UV laser as a function of the transmission rate of the gating foil can be used to determine the relative variance of gas gain for single electrons. We present the measurement principle and the result obtained using a stack of gas electron multipliers (GEMs) operated in a gas mixture of Ar-CF$_4$(3%)-isobutane(2%) at atmospheric pressure. Also discussed is the influence of the avalanche fluctuations on the spatial resolution of the ILD-TPC.
△ Less
Submitted 2 July, 2022;
originally announced July 2022.
-
The NEWS-G detector at SNOLAB
Authors:
L. Balogh,
C. Beaufort,
A. Brossard,
J. F. Caron,
M. Chapellier,
J. M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi-Fard,
Y. Deng,
K. Dering,
D. Durnford,
C. Garrah,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly,
P. Knights,
L. Kwon
, et al. (16 additional authors not shown)
Abstract:
The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve $\mathrm{sub-GeV/c^{2}}$ Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionization with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in C…
▽ More
The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve $\mathrm{sub-GeV/c^{2}}$ Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionization with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in Canada in 2021. This article details the different processes involved in the fabrication of the NEWS-G experiment. Also outlined in this paper are the mitigation strategies, measurements of radioactivity of the different components, and estimations of induced background event rates that were used to quantify and address detector backgrounds.
△ Less
Submitted 4 January, 2023; v1 submitted 30 May, 2022;
originally announced May 2022.
-
Double-hit separation and dE/dx resolution of a time projection chamber with GEM readout
Authors:
Yumi Aoki,
David Attié,
Ties Behnke,
Alain Bellerive,
Oleg Bezshyyko,
Deb Bhattacharya Sankar,
Purba Bhattacharya,
Sudeb Bhattacharya,
Yue Chang,
Paul Colas,
Gilles De Lentdecker,
Klaus Dehmelt,
Klaus Desch,
Ralf Diener,
Madhu Dixit,
Ulrich Einhaus,
Oleksiy Fedorchuk,
Ivor Fleck,
Keisuke Fujii,
Takahiro Fusayasu,
Serguei Ganjour,
Philippe Gros,
Peter Hayman,
Katsumasa Ikematsu,
Leif Jönsson
, et al. (46 additional authors not shown)
Abstract:
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC equipped with a triple gas electron multiplier (GEM) readout has been built and operated in an electron test beam. The TPC was placed in a 1 T solenoidal field…
▽ More
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC equipped with a triple gas electron multiplier (GEM) readout has been built and operated in an electron test beam. The TPC was placed in a 1 T solenoidal field at the DESY II Test Beam Facility, which provides an electron beam up to 6 GeV/c. The performance of the readout modules, in particular the spatial point resolution, is determined and compared to earlier tests. New studies are presented with first results on the separation of close-by tracks and the capability of the system to measure the specific energy loss dE/dx. This is complemented by a simulation study on the optimization of the readout granularity to improve particle identification by dE/dx.
△ Less
Submitted 25 November, 2022; v1 submitted 24 May, 2022;
originally announced May 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Measurements of the ionization efficiency of protons in methane
Authors:
NEWS-G Collaboration,
:,
L. Balogh,
C. Beaufort,
A. Brossard,
J. -F. Caron,
M. Chapellier,
J. -M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi-Fard,
Y. Deng,
K. Dering,
D. Durnford,
C. Garrah,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly
, et al. (19 additional authors not shown)
Abstract:
The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below…
▽ More
The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below $50~\mathrm{keV}$), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately 1 GeV, with kinetic energies in between $2~\mathrm{keV}$ and $13~\mathrm{keV}$ in $100~\mathrm{mbar}$ of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume, and a NEWS-G SPC to measure the deposited energy. The Comimac electrons are used as reference to calibrate the detector with 7 energy points. A detailed study of systematic effects led to the final results well fitted by $\mathrm{IQF}~(E_K)= E_K^α~/~(β+ E_K^α)$ with $α=0.70\pm0.08$ and $β= 1.32\pm0.17$. In agreement with some previous works in other gas mixtures, we measured less ionization energy than predicted from SRIM simulations, the difference reaching $33\%$ at $2~\mathrm{keV}$
△ Less
Submitted 25 June, 2022; v1 submitted 24 January, 2022;
originally announced January 2022.
-
Quenching factor measurements of neon nuclei in neon gas
Authors:
L. Balogh,
C. Beaufort,
A. Brossard,
J. -F. Caron,
M. Chapellier,
J. -M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi Fard,
Y. Deng,
K. Dering,
D. Durnford,
C. Garrah,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly,
P. Knights,
L. Kwon
, et al. (25 additional authors not shown)
Abstract:
The NEWS-G collaboration uses Spherical Proportional Counters (SPCs) to search for weakly interacting massive particles (WIMPs). In this paper, we report the first measurements of the nuclear quenching factor in neon gas at \SI{2}{bar} using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modelled using a simple power law: $α$E…
▽ More
The NEWS-G collaboration uses Spherical Proportional Counters (SPCs) to search for weakly interacting massive particles (WIMPs). In this paper, we report the first measurements of the nuclear quenching factor in neon gas at \SI{2}{bar} using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modelled using a simple power law: $α$E$_{nr}^β$; we determine its parameters by simultaneously fitting the data collected with the detector over a range of energies. We measured the following parameters in Ne:CH$_{4}$ at \SI{2}{bar}: $α$ = 0.2801 $\pm$ 0.0050 (fit) $\pm$ 0.0045 (sys) and $β$ = 0.0867 $\pm$ 0.020 (fit) $\pm$ 0.006(sys). Our measurements do not agree with expected values from SRIM or Lindhard theory. We demonstrated the feasibility of performing quenching factor measurements at sub-keV energies in gases using SPCs and a neutron beam.
△ Less
Submitted 3 December, 2021; v1 submitted 2 September, 2021;
originally announced September 2021.
-
Copper electroplating for background suppression in the NEWS-G experiment
Authors:
NEWS-G Collaboration,
:,
L. Balogh,
C. Beaufort,
A. Brossard,
R. Bunker,
J. -F. Caron,
M. Chapellier,
J. -M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi Fard,
Y. Deng,
K. Dering,
D. Durnford,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly
, et al. (26 additional authors not shown)
Abstract:
New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper.…
▽ More
New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper. Such copper is widely used in rare-event searches because it is readily available, there are no long-lived Cu radioisotopes, and levels of non-Cu radiocontaminants are generally low. However, measurements performed with a dedicated 210Po alpha counting method using an XIA detector confirmed a problematic concentration of 210Pb in bulk of the copper. To shield the proportional counter's active volume, a low-background electroforming method was adapted to the hemispherical shape to grow a 500-$μ$m thick layer of ultra-radiopure copper to the detector's inner surface. In this paper the process is described, which was prototyped at Pacific Northwest National Laboratory (PNNL), USA, and then conducted at full scale in the Laboratoire Souterrain de Modane in France. The radiopurity of the electroplated copper was assessed through Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Measurements of samples from the first (second) hemisphere give 68% confidence upper limits of <0.58 $μ$Bq/kg (<0.24 $μ$Bq/kg) and <0.26 $μ$Bq/kg (<0.11 $μ$Bq/kg) on the 232Th and 238U contamination levels, respectively. These results are comparable to previously reported measurements of electroformed copper produced for other rare-event searches, which were also found to have low concentration of 210Pb consistent with the background goals of the NEWS-G experiment.
△ Less
Submitted 13 December, 2020; v1 submitted 7 August, 2020;
originally announced August 2020.
-
Impact of the fac/mer isomerism on the excited states dynamics of pyridyl-carbene Fe(II) complexes
Authors:
Kevin Magra,
Edoardo Domenichini,
Antonio Francés-Monerris,
Cristina Cebrian,
Marc Beley,
Mohamed Darari,
Mariachiara Pastore,
Antonio Monari,
Xavier Assfeld,
Stefan Haacke,
Philippe C. Gros
Abstract:
The control of photophysical properties of iron complexes and especially of their excited states decay is a great challenge in the search for sustainable alternatives to noble metals in photochemical applications. Herein we report the synthesis and investigations of the photophysics of mer and fac iron complexes bearing bidentate pyridyl-NHC ligands, coordinating the Fe with three ligand-field enh…
▽ More
The control of photophysical properties of iron complexes and especially of their excited states decay is a great challenge in the search for sustainable alternatives to noble metals in photochemical applications. Herein we report the synthesis and investigations of the photophysics of mer and fac iron complexes bearing bidentate pyridyl-NHC ligands, coordinating the Fe with three ligand-field enhancing carbene bonds. Ultrafast transient absorption spectroscopy reveals two distinct excited state populations for both mer and fac forms, ascribed to the populations of the T1 and the T2 states, respectively, which decay to the ground state via parallel pathways. We find 3-4 ps and 15-20 ps excited state lifetimes, with respective amplitudes depending on the isomer. The longer lifetime exceeds the one reported for iron complexes with tridentate ligands analogues involving four iron-carbene bonds. By combining experimental and computational results, a mechanism based on the differential trap** of the triplet states in spin-crossover regions is proposed for the first time to explain the impact of the fac/mer isomerism on the overall excited-state lifetimes. Our results clearly highlight the impact of bidentate Pyridyl-NHC ligands on the photophysics of iron complexes, especially the paramount role of fac/mer isomerism in modulating the overall decay process, which can be potentially exploited in the design of new Fe(II)-based photoactive compound.
△ Less
Submitted 21 May, 2019;
originally announced May 2019.
-
Measurement of the electron transmission rate of the gating foil for the TPC of the ILC experiment
Authors:
M. Kobayashi,
T. Ogawa,
A. Shoji,
Y. Aoki,
K. Ikematsu,
P. Gros,
T. Kawaguchi,
D. Arai,
M. Iwamura,
K. Katsuki,
A. Koto,
M. Yoshikai,
K. Fujii,
T. Fusayasu,
Y. Kato,
S. Kawada,
T. Matsuda,
S. Narita,
K. Negishi,
H. Qi,
R. D. Settles,
A. Sugiyama,
T. Takahashi,
J. Tian,
T. Watanabe
, et al. (1 additional authors not shown)
Abstract:
We have developed a gating foil for the time projection chamber envisaged as a central tracker for the international linear collider experiment. It has a structure similar to the Gas Electron Multiplier (GEM) with a higher optical aperture ratio and functions as an ion gate without gas amplification. The transmission rate for electrons was measured in a counting mode for a wide range of the voltag…
▽ More
We have developed a gating foil for the time projection chamber envisaged as a central tracker for the international linear collider experiment. It has a structure similar to the Gas Electron Multiplier (GEM) with a higher optical aperture ratio and functions as an ion gate without gas amplification. The transmission rate for electrons was measured in a counting mode for a wide range of the voltages applied across the foil using an $^{55}$Fe source and a laser in the absence of a magnetic field. The blocking power of the foil against positive ions was estimated from the electron transmissions.
△ Less
Submitted 1 May, 2019; v1 submitted 5 March, 2019;
originally announced March 2019.
-
Precision laser-based measurements of the single electron response of SPCs for the NEWS-G light dark matter search experiment
Authors:
NEWS-G Collaboration,
:,
Q. Arnaud,
J. -P. Bard,
A. Brossard,
M. Chapellier,
M. Clark,
S. Crawford,
E. C. Corcoran,
A. Dastgheibi-Fard,
K. Dering,
P. Di Stefano,
D. Durnford,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
A. Kamaha,
I. Katsioulas,
D. G. Kelly,
P. Knights
, et al. (15 additional authors not shown)
Abstract:
Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and ana…
▽ More
Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and analysis methodology are presented along with various direct applications for the upcoming next phase of the experiment at SNOLAB. These include the continuous monitoring of the detector response and electron drift properties during dark matter search runs, as well as the experimental measurement of the trigger threshold efficiency. We measure a mean ionization energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$ for 2.8 keV X-rays, and demonstrate the feasibility of performing similar precision measurements at sub-keV energies for future gas mixtures to be used for dark matter searches at SNOLAB.
△ Less
Submitted 24 February, 2019;
originally announced February 2019.
-
Performance measurement of HARPO: a Time Projection Chamber as a gamma-ray telescope and polarimeter
Authors:
P. Gros,
S. Amano,
D. Attié,
P. Baron,
D. Baudin,
D. Bernard,
P. Bruel,
D. Calvet,
P. Colas,
S. Daté,
A. Delbart,
M. Frotin,
Y. Geerebaert,
B. Giebels,
D. Götz,
S. Hashimoto,
D. Horan,
T. Kotaka,
M. Louzir,
F. Magniette,
Y. Minamiyama,
S. Miyamoto,
H. Ohkuma,
P. Poilleux,
I. Semeniouk
, et al. (5 additional authors not shown)
Abstract:
We analyse the performance of a gas time projection chamber (TPC) as a high-performance gamma-ray telescope and polarimeter in the e$^+$e$^-$ pair creation regime. We use data collected at a gamma-ray beam of known polarisation. The TPC provides two orthogonal projections $(x,z)$ and $(y,z)$ of the tracks induced by each conversion in the gas volume. We use a simple vertex finder in which vertices…
▽ More
We analyse the performance of a gas time projection chamber (TPC) as a high-performance gamma-ray telescope and polarimeter in the e$^+$e$^-$ pair creation regime. We use data collected at a gamma-ray beam of known polarisation. The TPC provides two orthogonal projections $(x,z)$ and $(y,z)$ of the tracks induced by each conversion in the gas volume. We use a simple vertex finder in which vertices and pseudo-tracks exiting from them are identified.
We study the various contributions to the single-photon angular resolution using Monte Carlo simulations and compare them with the experimental data and find that they are in excellent agreement. The distribution of the azimutal angle of pair conversions shows a bias due to the non-cylindrical-symmetric structure of the detector. This bias would average out for a long duration exposure on a space mission, but for this pencil-beam characterisation we have ensured its accurate simulation by a double systematics control scheme, data taking with the detector rotated at several angles with respect to the beam polarisation direction and systematics control with a non-polarised beam.
We measure, for the first time, the polarisation asymmetry of a linearly polarised gamma-ray beam in the low energy pair creation regime. This sub-GeV energy range is critical for cosmic sources as their spectra are power laws which fall quickly as a function of increasing energy.
This work could pave the way to extending polarised gamma-ray astronomy beyond the MeV energy regime.
△ Less
Submitted 30 August, 2017; v1 submitted 20 June, 2017;
originally announced June 2017.
-
gamma-ray telescopes using conversions to electron-positron pairs: event generators, angular resolution and polarimetry
Authors:
Philippe Gros,
Denis Bernard
Abstract:
We benchmark various available event generators in Geant4 and EGS5 in the light of ongoing projects for high angular-resolution pair-conversion telescopes. We compare the distributions of key kinematic variables extracted from the geometry of the three final state particles. We validate and use as reference an exact generator using the full 5D differential cross-section of the conversion process.…
▽ More
We benchmark various available event generators in Geant4 and EGS5 in the light of ongoing projects for high angular-resolution pair-conversion telescopes. We compare the distributions of key kinematic variables extracted from the geometry of the three final state particles. We validate and use as reference an exact generator using the full 5D differential cross-section of the conversion process. We focus in particular on the effect of the unmeasured recoiling nucleus on the angular resolution. We show that for high resolution trackers, the choice of the generator affects the estimated resolution of the telescope. We also show that the current available generator are unable to describe accurately a linearly polarised photon source.
△ Less
Submitted 19 January, 2017; v1 submitted 19 December, 2016;
originally announced December 2016.
-
$γ$-ray polarimetry with conversions to $e^+e^-$ pairs: polarization asymmetry and the way to measure it
Authors:
Philippe Gros,
Denis Bernard
Abstract:
We revisit the measurement of the polarization fraction, $P$, and the measurement of the polarization angle of partially linearly-polarized gamma rays using their conversion to $e^+e^-$ pairs in the field of a nucleus. We show that an inappropriate definition of the azimuthal angle, $\varphi$, used to reference the orientation of the final state degrades the precision of the measurement of $P$, by…
▽ More
We revisit the measurement of the polarization fraction, $P$, and the measurement of the polarization angle of partially linearly-polarized gamma rays using their conversion to $e^+e^-$ pairs in the field of a nucleus. We show that an inappropriate definition of the azimuthal angle, $\varphi$, used to reference the orientation of the final state degrades the precision of the measurement of $P$, by comparison to the optimal case where the bisector angle of the electron and of the positron momenta is used. We then focus on the lowest part of the energy spectrum, below $\approx 10\,$MeV, where a large part of the statistics lie for a cosmic source. We obtain the value of the polarization asymmetry, $A$, of pair conversion at threshold and we show that in the case where the correct expression is used for $\varphi$, the measured value of $A$ tends to the limit.
△ Less
Submitted 20 December, 2016; v1 submitted 16 November, 2016;
originally announced November 2016.
-
First measurement of polarisation asymmetry of a gamma-ray beam between 1.74 to 74 MeV with the HARPO TPC
Authors:
Philippe Gros,
Sho Amano,
David Attié,
Denis Bernard,
Philippe Bruel,
Denis Calvet,
Paul Colas,
Schin Daté,
Alain Delbart,
Mickael Frotin,
Yannick Geerebaert,
Berrie Giebels,
Diego Götz,
S. Hashimoto,
Deirdr Horan,
T. Kotaka,
Marc Louzir,
Y. Minamiyama,
Shuji Miyamoto,
H. Ohkuma,
Patrick Poilleux,
Igor Semeniouk,
Patrick Sizun,
A. Takemoto,
M. Yamaguchi
, et al. (1 additional authors not shown)
Abstract:
Current $γ$-ray telescopes suffer from a gap in sensitivity in the energy range between 100keV and 100MeV, and no polarisation measurement has ever been done on cosmic sources above 1MeV. Past and present e$^+$e$^-$ pair telescopes are limited at lower energies by the multiple scattering of electrons in passive tungsten converter plates. This results in low angular resolution, and, consequently, a…
▽ More
Current $γ$-ray telescopes suffer from a gap in sensitivity in the energy range between 100keV and 100MeV, and no polarisation measurement has ever been done on cosmic sources above 1MeV. Past and present e$^+$e$^-$ pair telescopes are limited at lower energies by the multiple scattering of electrons in passive tungsten converter plates. This results in low angular resolution, and, consequently, a drop in sensitivity to point sources below 1GeV. The polarisation information, which is carried by the azimuthal angle of the conversion plane, is lost for the same reasons.
HARPO (Hermetic ARgon POlarimeter) is an R\&D program to characterise the operation of a gaseous detector (a Time Projection Chamber or TPC) as a high angular-resolution and sensitivity telescope and polarimeter for $γ$ rays from cosmic sources. It represents a first step towards a future space instrument in the MeV-GeV range.
We built and characterised a 30cm cubic demonstrator [SPIE 91441M], and put it in a polarised $γ$-ray beam at the NewSUBARU accelerator in Japan. Data were taken at photon energies from 1.74MeV to 74MeV, and with different polarisation configurations.
We describe the experimental setup in beam. We then describe the software we developed to reconstruct the photon conversion events, with special focus on low energies. We also describe the thorough simulation of the detector used to compare results. Finally we will present the performance of the detector as extracted from this analysis and preliminary measurements of the polarisation asymmetry.
This beam-test qualification of a gas TPC prototype in a $γ$-ray beam could open the way to high-performance $γ$-ray astronomy and polarimetry in the MeV-GeV energy range in the near future.
△ Less
Submitted 30 June, 2016;
originally announced June 2016.
-
A Time Projection Chamber with GEM-Based Readout
Authors:
The LCTPC Collaboration,
David Attié,
Ties Behnke,
Alain Bellerive,
Oleg Bezshyyko,
Deb Sankar Bhattacharya,
Purba Bhattacharya,
Sudeb Bhattacharya,
Stefano Caiazza,
Paul Colas,
Gilles De Lentdecker,
Klaus Dehmelt,
Klaus Desch,
Ralf Diener,
Madhu Dixit,
Ivor Fleck,
Keisuke Fujii,
Takahiro Fusayasu,
Serguei Ganjour,
Yuanning Gao,
Philippe Gros,
Peter Hayman,
Vincent Hedberg,
Katsumasa Ikematsu,
Leif Jönsson
, et al. (45 additional authors not shown)
Abstract:
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a…
▽ More
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a 6 GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.
△ Less
Submitted 4 April, 2016;
originally announced April 2016.
-
Measurement of 1.7 to 74 MeV polarised gamma rays with the HARPO TPC
Authors:
Y. Geerebaert,
Ph. Gros,
S. Amano,
D. Attié,
D. Bernard,
P. Bruel,
D. Calvet,
P. Colas,
S. Daté,
A. Delbart,
M. Frotin,
B. Giebels,
D. Götz,
S. Hashimoto,
D. Horan,
T. Kotaka,
M. Louzir,
Y. Minamiyama,
S. Miyamoto,
H. Ohkuma,
P. Poilleux,
I. Semeniouk,
P. Sizun,
A. Takemoto,
M. Yamaguchi
, et al. (1 additional authors not shown)
Abstract:
Current γ-ray telescopes based on photon conversions to electron-positron pairs, such as Fermi, use tungsten converters. They suffer of limited angular resolution at low energies, and their sensitivity drops below 1 GeV. The low multiple scattering in a gaseous detector gives access to higher angular resolution in the MeV-GeV range, and to the linear polarisation of the photons through the azimuth…
▽ More
Current γ-ray telescopes based on photon conversions to electron-positron pairs, such as Fermi, use tungsten converters. They suffer of limited angular resolution at low energies, and their sensitivity drops below 1 GeV. The low multiple scattering in a gaseous detector gives access to higher angular resolution in the MeV-GeV range, and to the linear polarisation of the photons through the azimuthal angle of the electron-positron pair.
HARPO is an R&D program to characterise the operation of a TPC (Time Projection Chamber) as a high angular-resolution and sensitivity telescope and polarimeter for γ rays from cosmic sources. It represents a first step towards a future space instrument. A 30 cm cubic TPC demonstrator was built, and filled with 2 bar argon-based gas. It was put in a polarised γ-ray beam at the NewSUBARU accelerator in Japan in November 2014. Data were taken at different photon energies from 1.7 MeV to 74 MeV, and with different polarisation configurations. The electronics setup is described, with an emphasis on the trigger system. The event reconstruction algorithm is quickly described, and preliminary measurements of the polarisation of 11 MeVphotons are shown.
△ Less
Submitted 22 March, 2016;
originally announced March 2016.
-
Sealed operation, and circulation and purification of gas in the HARPO TPC
Authors:
M. Frotin,
P. Gros,
D. Attié,
D. Bernard,
V. Dauvois,
A. Delbart,
D. Durand,
Y. Geerebaert,
S. Legand,
P. Magnier,
P. Poilleux,
I. Semeniouk
Abstract:
HARPO is a time projection chamber (TPC) demonstrator of a gamma-ray telescope and polarimeter in the MeV-GeV range, for a future space mission. We present the evolution of the TPC performance over a five month sealed-mode operation, by the analysis of cosmic-ray data, followed by the fast and complete recovery of the initial gas properties using a lightweight gas circulation and purification syst…
▽ More
HARPO is a time projection chamber (TPC) demonstrator of a gamma-ray telescope and polarimeter in the MeV-GeV range, for a future space mission. We present the evolution of the TPC performance over a five month sealed-mode operation, by the analysis of cosmic-ray data, followed by the fast and complete recovery of the initial gas properties using a lightweight gas circulation and purification system.
△ Less
Submitted 10 December, 2015;
originally announced December 2015.
-
HARPO: beam characterization of a TPC for gamma-ray polarimetry and high angular-resolution astronomy in the MeV-GeV range
Authors:
Shaobo Wang,
Denis Bernard,
Philippe Bruel,
Mickael Frotin,
Yannick Geerebaert,
Berrie Giebels,
Philippe Gros,
Deirdre Horan,
Marc Louzir,
Patrick Poilleux,
Igor Semeniouk,
David Attié,
Denis Calvet,
Paul Colas,
Alain Delbart,
Patrick Sizun,
Diego Götz,
Sho Amano,
Takuya Kotaka,
Satoshi Hashimoto,
Yasuhito Minamiyama,
Akinori Takemoto,
Masashi Yamaguchi,
Shuji Miyamoto,
Schin Daté
, et al. (1 additional authors not shown)
Abstract:
A time projection chamber (TPC) can be used to measure the polarization of gamma rays with excellent angular precision and sensitivity in the MeV-GeV energy range through the conversion of photons to e+e- pairs. The Hermetic ARgon POlarimeter (HARPO) prototype was built to demonstrate this concept. It was recently tested in the polarized photon beam at the NewSUBARU facility in Japan. We present t…
▽ More
A time projection chamber (TPC) can be used to measure the polarization of gamma rays with excellent angular precision and sensitivity in the MeV-GeV energy range through the conversion of photons to e+e- pairs. The Hermetic ARgon POlarimeter (HARPO) prototype was built to demonstrate this concept. It was recently tested in the polarized photon beam at the NewSUBARU facility in Japan. We present this data-taking run, which demonstrated the excellent performance of the HARPO TPC.
△ Less
Submitted 12 March, 2015;
originally announced March 2015.
-
HARPO: a TPC as a gamma-ray telescope and polarimeter
Authors:
Denis Bernard,
Philippe Bruel,
Mickael Frotin,
Yannick Geerebaert,
Berrie Giebels,
Philippe Gros,
Deirdre Horan,
Marc Louzir,
Patrick Poilleux,
Igor Semeniouk,
Shaobo Wang,
Shebli Anvar,
David Attié,
Paul Colas,
Alain Delbart,
Patrick Sizun,
Diego Götz
Abstract:
A gas Time Projection Chamber can be used for gamma-ray astronomy with excellent angular-precision and sensitivity to faint sources, and for polarimetry, through the measurement of photon conversion to $e^+e^-$ pairs. We present the expected performance in simulations and the recent development of a demonstrator for tests in a polarized photon beam.
A gas Time Projection Chamber can be used for gamma-ray astronomy with excellent angular-precision and sensitivity to faint sources, and for polarimetry, through the measurement of photon conversion to $e^+e^-$ pairs. We present the expected performance in simulations and the recent development of a demonstrator for tests in a polarized photon beam.
△ Less
Submitted 28 July, 2014; v1 submitted 18 June, 2014;
originally announced June 2014.
-
Activity report of ILD-TPC Asia group
Authors:
Y. Kato,
R. Yonamine,
P. Gros,
J. Tian,
S. Kawada,
K. Fujii,
T. Matsuda,
A. Sugiyama,
O. Nitoh,
T. Watanabe,
T. Fusayasu,
T. Takahashi,
M. Kobayashi
Abstract:
The purpose of ILD-TPC Asia group is realization of high precision Time Projection Chamber (TPC) with Gas Electron Multiplier (GEM) as a central tracker in International Linear Collider (ILC). We have been studying the many R&D items to build the real detector as a member of LCTPC collaboration. This paper describes the our efforts for realization of the ILD-TPC, the result of test beam using larg…
▽ More
The purpose of ILD-TPC Asia group is realization of high precision Time Projection Chamber (TPC) with Gas Electron Multiplier (GEM) as a central tracker in International Linear Collider (ILC). We have been studying the many R&D items to build the real detector as a member of LCTPC collaboration. This paper describes the our efforts for realization of the ILD-TPC, the result of test beam using large prototype TPC, local field distortion, positive ion effects and gate devices, and cooling electronics which are key items to build ILD-TPC.
△ Less
Submitted 30 March, 2014;
originally announced March 2014.
-
AGATA - Advanced Gamma Tracking Array
Authors:
S. Akkoyun,
A. Algora,
B. Alikhani,
F. Ameil,
G. de Angelis,
L. Arnold,
A. Astier,
A. Ataç,
Y. Aubert,
C. Aufranc,
A. Austin,
S. Aydin,
F. Azaiez,
S. Badoer,
D. L. Balabanski,
D. Barrientos,
G. Baulieu,
R. Baumann,
D. Bazzacco,
F. A. Beck,
T. Beck,
P. Bednarczyk,
M. Bellato,
M. A. Bentley,
G. Benzoni
, et al. (329 additional authors not shown)
Abstract:
The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation gamma-ray spectrometer. AGATA is based on the technique of gamma-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a gamma ray deposits its energy within the…
▽ More
The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation gamma-ray spectrometer. AGATA is based on the technique of gamma-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a gamma ray deposits its energy within the detector volume. Reconstruction of the full interaction path results in a detector with very high efficiency and excellent spectral response. The realization of gamma-ray tracking and AGATA is a result of many technical advances. These include the development of encapsulated highly-segmented germanium detectors assembled in a triple cluster detector cryostat, an electronics system with fast digital sampling and a data acquisition system to process the data at a high rate. The full characterization of the crystals was measured and compared with detector-response simulations. This enabled pulse-shape analysis algorithms, to extract energy, time and position, to be employed. In addition, tracking algorithms for event reconstruction were developed. The first phase of AGATA is now complete and operational in its first physics campaign. In the future AGATA will be moved between laboratories in Europe and operated in a series of campaigns to take advantage of the different beams and facilities available to maximize its science output. The paper reviews all the achievements made in the AGATA project including all the necessary infrastructure to operate and support the spectrometer.
△ Less
Submitted 17 September, 2012; v1 submitted 24 November, 2011;
originally announced November 2011.
-
The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events
Authors:
J. Alme,
Y. Andres,
H. Appelshauser,
S. Bablok,
N. Bialas,
R. Bolgen,
U. Bonnes,
R. Bramm,
P. Braun-Munzinger,
R. Campagnolo,
P. Christiansen,
A. Dobrin,
C. Engster,
D. Fehlker,
P. Foka,
U. Frankenfeld,
J. J. Gaardhoje,
C. Garabatos,
P. Glassel,
C. Gonzalez Gutierrez,
P. Gros,
H. -A. Gustafsson,
H. Helstrup,
M. Hoch,
M. Ivanov
, et al. (51 additional authors not shown)
Abstract:
The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we des…
▽ More
The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb--Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate results close to those specified in the TPC Technical Design Report.
△ Less
Submitted 12 January, 2010;
originally announced January 2010.
-
Design of the Ess RFQs and Chop** Line
Authors:
R. Duperrier,
R. Ferdinand,
P. Gros,
J-M. Lagniel,
N. Pichoff,
D. Uriot,
CEA-Saclay,
DSM-DAPNIA-SEA
Abstract:
The chop** line is a critical part of the ESS linac in term of technical realisation of the choppers and preservation of the beam qualities. A new optimised design of the ESS RFQs and chop** lines is reported. The beam dynamics has been optimised with H- beam currents up to 100-mA to have safety margin with respect to the ESS goals. The first RFQ transmits almost 99.7% of the beam up to 2 Me…
▽ More
The chop** line is a critical part of the ESS linac in term of technical realisation of the choppers and preservation of the beam qualities. A new optimised design of the ESS RFQs and chop** lines is reported. The beam dynamics has been optimised with H- beam currents up to 100-mA to have safety margin with respect to the ESS goals. The first RFQ transmits almost 99.7% of the beam up to 2 MeV. The line with two choppers allows a perfect chop** between 2 bunches. The second RFQ accelerates the particles up to 5 MeV with a transmission close to 100%.
△ Less
Submitted 18 August, 2000;
originally announced August 2000.