High-resolution MHz time- and angle-resolved photoemission spectroscopy based on a tunable vacuum ultraviolet source
Authors:
Lukas Hellbrück,
Michele Puppin,
Fei Guo,
Daniel D. Hickstein,
Siham Benhabib,
Marco Grioni,
J. Hugo Dil,
Thomas LaGrange,
Henrik M. Rønnow,
Fabrizio Carbone
Abstract:
Time and angle-resolved photoemission spectroscopy (trARPES) allows direct map** of the electronic band structure and its dynamic response on femtosecond timescales. Here, we present a new ARPES system, powered by a new fiber-based femtosecond light source in the vacuum ultraviolet (VUV) range, accessing the complete first Brillouin zone for most materials. We present trARPES data on Au(111), po…
▽ More
Time and angle-resolved photoemission spectroscopy (trARPES) allows direct map** of the electronic band structure and its dynamic response on femtosecond timescales. Here, we present a new ARPES system, powered by a new fiber-based femtosecond light source in the vacuum ultraviolet (VUV) range, accessing the complete first Brillouin zone for most materials. We present trARPES data on Au(111), polycrystalline Au, Bi2Se3 and TaTe2, demonstrating an energy resolution of 21 meV with a time resolution of <360 fs, at a high repetition rate of 1 MHz. The system is integrated with an extreme ultraviolet (EUV) high harmonic generation (HHG) beamline, enabling excellent tunability of the time-bandwidth resolution.
△ Less
Submitted 25 March, 2024; v1 submitted 1 February, 2024;
originally announced February 2024.
High-resolution soft-X-ray beamline ADRESS at Swiss Light Source for resonant inelastic X-ray scattering and angle-resolved photoelectron spectroscopies
Authors:
V. N. Strocov,
T. Schmitt,
U. Flechsig,
T. Schmidt,
A. Imhof,
Q. Chen,
J. Raabe,
R. Betemps,
D. Zimoch,
J. Krempasky,
A. Piazzalunga,
X. Wang,
M. Grioni,
L. Patthey
Abstract:
We describe the concepts and technical realization of the high-resolution soft-X-ray beamline ADRESS operating in the energy range from 300 to 1600 eV and intended for Resonant Inelastic X-ray Scattering (RIXS) and Angle-Resolved Photoelectron Spectroscopy (ARPES). The photon source is an undulator of novel fixed-gap design where longitudinal movement of permanent magnetic arrays controls not on…
▽ More
We describe the concepts and technical realization of the high-resolution soft-X-ray beamline ADRESS operating in the energy range from 300 to 1600 eV and intended for Resonant Inelastic X-ray Scattering (RIXS) and Angle-Resolved Photoelectron Spectroscopy (ARPES). The photon source is an undulator of novel fixed-gap design where longitudinal movement of permanent magnetic arrays controls not only the light polarization (including circular and 0-180 deg rotatable linear polarizations) but also the energy without changing the gap. The beamline optics is based on the well-established scheme of plane grating monochromator (PGM) operating in collimated light. The ultimate resolving power E/dE is above 33000 at 1 keV photon energy. The choice of blazed vs lamellar gratings and optimization of their profile parameters is described. Due to glancing angles on the mirrors as well as optimized groove densities and profiles of the gratings, high photon flux is achieved up to 1.0e13 photons/s/0.01%BW at 1 keV. Ellipsoidal refocusing optics used for the RIXS endstation demagnifies the vertical spot size down to 4 um, which allows slitless operation and thus maximal transmission of the high-resolution RIXS spectrometer delivering E/dE better than 11000 at 1 keV photon energy. Apart from the beamline optics, we give an overview of the control system, describe diagnostics and software tools, and discuss strategies used for the optical alignment. An introduction to the concepts and instrumental realization of the ARPES and RIXS endstations is given.
△ Less
Submitted 13 November, 2009;
originally announced November 2009.