-
Results and Limits of Time Division Multiplexing for the BICEP Array High Frequency Receivers
Authors:
S. Fatigoni,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
D. Beck,
J. J. Bock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. J. Cukierman,
E. V. Denison,
M. I. Dierickx,
L. Duband,
M. Eiben,
J. P. Filippini,
A. Fortes,
M. Gao,
C. Giannakopoulos,
N. Goeckner-Wald,
D. C. Goldfinger
, et al. (62 additional authors not shown)
Abstract:
Time-Division Multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high frequency receivers, observing at 150GHz and 220/270GHz, will have 7776 TES detectors tiled on the…
▽ More
Time-Division Multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high frequency receivers, observing at 150GHz and 220/270GHz, will have 7776 TES detectors tiled on the focal plane. The constraints set by these two receivers required a redesign of the warm readout electronics. The new version of the standard Multi Channel Electronics, developed and built at the University of British Columbia, is presented here for the first time. BICEP Array operates Time Division Multiplexing readout technology to the limits of its capabilities in terms of multiplexing rate, noise and crosstalk, and applies them in rigorously demanding scientific application requiring extreme noise performance and systematic error control. Future experiments like CMB-S4 plan to use TES bolometers with Time Division/SQUID-based readout for an even larger number of detectors.
△ Less
Submitted 24 October, 2023; v1 submitted 16 October, 2023;
originally announced October 2023.
-
Conceptual Design of the Modular Detector and Readout System for the CMB-S4 survey experiment
Authors:
D. R. Barron,
Z. Ahmed,
J. Aguilar,
A. J. Anderson,
C. F. Baker,
P. S. Barry,
J. A. Beall,
A. N. Bender,
B. A. Benson,
R. W. Besuner,
T. W. Cecil,
C. L. Chang,
S. C. Chapman,
G. E. Chesmore,
G. Derylo,
W. B. Doriese,
S. M. Duff,
T. Elleflot,
J. P. Filippini,
B. Flaugher,
J. G. Gomez,
P. K. Grimes,
R. Gualtieri,
I. Gullett,
G. Haller
, et al. (25 additional authors not shown)
Abstract:
We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental…
▽ More
We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over a wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4's science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 square meters of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
Receiver development for BICEP Array, a next-generation CMB polarimeter at the South Pole
Authors:
L. Moncelsi,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
J. J. Bock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. Cukierman,
E. V. Denison,
M. Dierickx,
L. Duband,
M. Eiben,
S. Fatigoni,
J. P. Filippini,
N. Goeckner-Wald,
D. C. Goldfinger,
J. Grayson,
P. Grimes,
G. Hall
, et al. (50 additional authors not shown)
Abstract:
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primordial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date…
▽ More
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primordial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date. BICEP Array (BA) is the Stage-3 instrument of the BK program and will comprise four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz with a combined 32,000+ detectors; such wide frequency coverage is necessary for control of the Galactic foregrounds, which also produce degree-scale $B$-mode signal. The 30/40 GHz receiver is designed to constrain the synchrotron foreground and has begun observing at the South Pole in early 2020. By the end of a 3-year observing campaign, the full BICEP Array instrument is projected to reach $σ_r$ between 0.002 and 0.004, depending on foreground complexity and degree of removal of $B$-modes due to gravitational lensing (delensing). This paper presents an overview of the design, measured on-sky performance and calibration of the first BA receiver. We also give a preview of the added complexity in the time-domain multiplexed readout of the 7,776-detector 150 GHz receiver.
△ Less
Submitted 7 December, 2020;
originally announced December 2020.
-
Waveguide-to-planar circuit transition for millimetre-wave detectors
Authors:
G. Yassin,
P. K. Grimes,
O. G. King,
C. E. North
Abstract:
We present a novel design of a waveguide to microstrip or coplanar waveguide transition using a unilateral finline taper. The transition from the unilateral finline mode to the TEM microstrip mode is done directly, avoiding the antipodal finline tapers that have commonly been employed. This results in significant simplification of the design and fabrication, and shortening of the chip length, th…
▽ More
We present a novel design of a waveguide to microstrip or coplanar waveguide transition using a unilateral finline taper. The transition from the unilateral finline mode to the TEM microstrip mode is done directly, avoiding the antipodal finline tapers that have commonly been employed. This results in significant simplification of the design and fabrication, and shortening of the chip length, thereby reducing insertion loss. In this paper we shall present designs at 90 GHz that can be employed in superconducting tunnel junction mixers or Transition Edge Sensor bolometers, and scale-model measurements at 15 GHz.
△ Less
Submitted 7 September, 2008; v1 submitted 2 June, 2008;
originally announced June 2008.
-
Design and Test of a Carbon-Tolerant Alkaline Fuel Cell
Authors:
Mirna Urquidi-Macdonald,
Ayusman Sen,
Patrick Grimes,
Ashutosh Tewari,
Varun Sambhy
Abstract:
This paper presents new results which may constitute a breakthrough in the effort to develop fuel cells truly suitable for use in cars and trucks. For decades, researchers have known that the alkaline fuel cell (AFC) is much cheaper to make, more efficient and more durable than the more popular PEM fuel cell; however, "carbon poisoning" (either from CO2 in air or from contaminants in reformed me…
▽ More
This paper presents new results which may constitute a breakthrough in the effort to develop fuel cells truly suitable for use in cars and trucks. For decades, researchers have known that the alkaline fuel cell (AFC) is much cheaper to make, more efficient and more durable than the more popular PEM fuel cell; however, "carbon poisoning" (either from CO2 in air or from contaminants in reformed methanol) causes big problems in the kind of oxygen-hydrogen AFC commonly used in space. This paper reports successful tests of a technique for coating the electrodes with polystyrene which, in conjunction with older common-sense techniques, appears to solve the problem. This kind of design is applicable to cars run on hydrogen fuel, on reformed methanol or even direct methanol. Develo** a test methodology was a major part of the work. A foreword by one of the sponsors at NSF discusses the larger importance of this work for energy security and the environment.
△ Less
Submitted 19 April, 2005;
originally announced April 2005.