-
Extended T2 times of shallow implanted NV in chemically mechanically polished diamond
Authors:
S. Tyler,
J. Newland,
P. Hepworth,
A. Wijesekara,
I. R. Gullick,
M. L. Markham,
M. E. Newton,
B. L. Green
Abstract:
Mechanical polishing of diamond is known to be detrimental to the spin lifetime and strain environment of near-surface defects. By utilising a chemical mechanical polishing (CMP) process, we demonstrate that we can achieve 13C-limited spin lifetimes of shallow implanted (<34 nm) NV centres in an industrially scalable process. We compare spin lifetimes (T2) of three diamonds processed with CMP with…
▽ More
Mechanical polishing of diamond is known to be detrimental to the spin lifetime and strain environment of near-surface defects. By utilising a chemical mechanical polishing (CMP) process, we demonstrate that we can achieve 13C-limited spin lifetimes of shallow implanted (<34 nm) NV centres in an industrially scalable process. We compare spin lifetimes (T2) of three diamonds processed with CMP with one processed by inductively-coupled plasma reactive ion etching (ICP-RIE), and observe an increased median T2 of 355 microseconds in the CMP-processed samples for 15NV centres implanted and annealed under identical conditions.
△ Less
Submitted 17 May, 2024;
originally announced May 2024.
-
The ATLAS Readout System for LHC Runs 2 and 3
Authors:
A. Borga,
R. Blair,
G. J. Crone,
B. Green,
A. Kugel,
M. Joos,
J. Love,
J. G. Panduro Vazquez,
J. Schumacher,
P. Teixeira-Dias,
L. Tremblet,
W. Vandelli,
J. C. Vermeulen,
O. Rifki,
P. Werner,
F. J. Wickens
Abstract:
The ReadOut System (ROS) is a central part of the data acquisition (DAQ) system of the ATLAS Experiment at the CERN Large Hadron Collider (LHC). The system is responsible for receiving and buffering event data from all detector subsystems and serving these to the High Level Trigger (HLT) system via a 10 GbE network, discarding or transporting data onward once the trigger has completed its selectio…
▽ More
The ReadOut System (ROS) is a central part of the data acquisition (DAQ) system of the ATLAS Experiment at the CERN Large Hadron Collider (LHC). The system is responsible for receiving and buffering event data from all detector subsystems and serving these to the High Level Trigger (HLT) system via a 10 GbE network, discarding or transporting data onward once the trigger has completed its selection process. The ATLAS ROS was completely replaced during the 2013-2014 experimental shutdown in order to meet the demanding conditions expected during LHC Run 2 and Run 3 (2015-2025). The ROS consists of roughly one hundred Linux-based 2U-high rack-mounted servers equipped with PCIe I/O cards and 10 GbE interfaces. This paper documents the system requirements for LHC Runs 2 and 3 and the design choices taken to meet them. The results of performance measurements and the re-use of ROS technology for the development of data sources, test platforms for other systems, and another ATLAS DAQ system component, namely the Region of Interest Builder (RoIB), are also discussed. Finally performance results for Run 2 operations are presented before looking at the upgrade for Run 3.
△ Less
Submitted 21 July, 2023;
originally announced July 2023.
-
Long Spin Coherence Times of Nitrogen Vacancy Centres in Milled Nanodiamonds
Authors:
B. D. Wood,
G. A. Stimpson,
J. E. March,
Y. N. D. Lekhai,
C. J. Stephen,
B. L. Green,
A. C. Frangeskou,
L. Ginés,
S. Mandal,
O. A. Williams,
G. W. Morley
Abstract:
Nanodiamonds containing negatively charged nitrogen vacancy centres (${\text{NV}}^{-}$) have applications as localized sensors in biological material and have been proposed as a platform to probe the macroscopic limits of spatial superposition and the quantum nature of gravity. A key requirement for these applications is to obtain nanodiamonds containing ${\text{NV}}^{-}$ with long spin coherence…
▽ More
Nanodiamonds containing negatively charged nitrogen vacancy centres (${\text{NV}}^{-}$) have applications as localized sensors in biological material and have been proposed as a platform to probe the macroscopic limits of spatial superposition and the quantum nature of gravity. A key requirement for these applications is to obtain nanodiamonds containing ${\text{NV}}^{-}$ with long spin coherence times. Using milling to fabricate nanodiamonds processes the full 3D volume of the bulk material at once, unlike etching, but has, up to now, limited ${\text{NV}}^{-}$ spin coherence times. Here, we use natural isotopic abundance nanodiamonds produced by ${\text{Si}}_{3}{\text{N}}_{4}$ ball milling of bulk diamond grown by chemical vapour deposition with an average single substitutional nitrogen concentration of $121 ~\text{ppb}$. We show that the electron spin coherence times of ${\text{NV}}^{-}$ centres in these nanodiamonds can exceed $400 ~μ\text{s}$ at room temperature with dynamical decoupling. Scanning electron microscopy provides images of the specific nanodiamonds containing ${\text{NV}}^{-}$ for which a spin coherence time was measured.
△ Less
Submitted 3 May, 2022; v1 submitted 3 December, 2021;
originally announced December 2021.
-
Imaging damage in steel using a diamond magnetometer
Authors:
L. Q. Zhou,
R. L. Patel,
A. C. Frangeskou,
A. Nikitin,
B. L. Green,
B. G. Breeze,
S. Onoda,
J. Isoya,
G. W. Morley
Abstract:
We demonstrate a simple, robust and contactless method for non-destructive testing of magnetic materials such as steel. This uses a fiber-coupled magnetic sensor based on nitrogen vacancy centers (NVC) in diamond without magnetic shielding. Previous NVC magnetometry has sought a homogeneous bias magnetic field, but in our design we deliberately applied an inhomogeneous magnetic field. As a consequ…
▽ More
We demonstrate a simple, robust and contactless method for non-destructive testing of magnetic materials such as steel. This uses a fiber-coupled magnetic sensor based on nitrogen vacancy centers (NVC) in diamond without magnetic shielding. Previous NVC magnetometry has sought a homogeneous bias magnetic field, but in our design we deliberately applied an inhomogeneous magnetic field. As a consequence of our experimental set-up we achieve a high spatial resolution: 1~mm in the plane parallel and 0.1~mm in the plane perpendicular to the surface of the steel. Structural damage in the steel distorts this inhomogeneous magnetic field and by detecting this distortion we reconstruct the damage profile through quantifying the shifts in the NVC Zeeman splitting. This works even when the steel is covered by a non-magnetic material. The lift-off distance of our sensor head from the surface of 316 stainless steel is up to 3~mm.
△ Less
Submitted 4 November, 2020;
originally announced November 2020.
-
Sub-nanotesla magnetometry with a fibre-coupled diamond sensor
Authors:
R. L. Patel,
L. Q. Zhou,
A. C. Frangeskou,
G. A. Stimpson,
B. G. Breeze,
A. Nikitin,
M. W. Dale,
E. C. Nichols,
W. Thornley,
B. L. Green,
M. E. Newton,
A. M. Edmonds,
M. L. Markham,
D. J. Twitchen,
G. W. Morley
Abstract:
Sensing small magnetic fields is relevant for many applications ranging from geology to medical diagnosis. We present a fiber-coupled diamond magnetometer with a sensitivity of (310 $\pm$ 20) pT$/\sqrt{\text{Hz}}$ in the frequency range of 10-150 Hz. This is based on optically detected magnetic resonance of an ensemble of nitrogen vacancy centers in diamond at room temperature. Fiber coupling mean…
▽ More
Sensing small magnetic fields is relevant for many applications ranging from geology to medical diagnosis. We present a fiber-coupled diamond magnetometer with a sensitivity of (310 $\pm$ 20) pT$/\sqrt{\text{Hz}}$ in the frequency range of 10-150 Hz. This is based on optically detected magnetic resonance of an ensemble of nitrogen vacancy centers in diamond at room temperature. Fiber coupling means the sensor can be conveniently brought within 2 mm of the object under study.
△ Less
Submitted 19 February, 2020;
originally announced February 2020.
-
An open-source high-frequency lock-in amplifier
Authors:
G. A. Stimpson,
M. S. Skilbeck,
R. L. Patel,
B. L. Green,
G. W. Morley
Abstract:
We present characterization of a lock-in amplifier based on a field programmable gate array capable of demodulation at up to 50 MHz. The system exhibits 90 nV/sqrt(Hz) of input noise at an optimum demodulation frequency of 500 kHz.The passband has a full-width half-maximum of 2.6 kHz for modulation frequencies above 100 kHz. Our code is opensource and operates on a commercially available platform.
We present characterization of a lock-in amplifier based on a field programmable gate array capable of demodulation at up to 50 MHz. The system exhibits 90 nV/sqrt(Hz) of input noise at an optimum demodulation frequency of 500 kHz.The passband has a full-width half-maximum of 2.6 kHz for modulation frequencies above 100 kHz. Our code is opensource and operates on a commercially available platform.
△ Less
Submitted 12 September, 2019; v1 submitted 26 November, 2018;
originally announced November 2018.
-
Distribution of volume, microvoid percolation, and packing density in globular proteins
Authors:
Jenny Farmer,
Sheridan B. Green,
Donald J. Jacobs
Abstract:
A fast and accurate grid-based method with low memory requirement is presented to calculate volume characteristics in molecular systems. The distribution of volume and packing density is characterized in globular proteins, where void space is decomposed into microvoid volume and cavities based on a spherical test probe with variable radius. A scan over test probe radius is mapped onto a site perco…
▽ More
A fast and accurate grid-based method with low memory requirement is presented to calculate volume characteristics in molecular systems. The distribution of volume and packing density is characterized in globular proteins, where void space is decomposed into microvoid volume and cavities based on a spherical test probe with variable radius. A scan over test probe radius is mapped onto a site percolation problem for microvoid volume. Finite-size scaling is applied to determine critical exponents, which are found to be consistent with connectivity percolation exponents in three dimensions. Disparate results in the literature regarding packing density in the core of a protein compared to on its surface, and with respect to protein size, is elucidated in terms of microvoid volume within a unified implicit-solvent model. By parameterizing the model to match the results of explicit-solvent models that agree with experimental data, we verify that packing density within globular proteins is spatially uniform and independent of protein size.
△ Less
Submitted 19 October, 2018;
originally announced October 2018.
-
Three-dimensional solid-state qubit arrays with long-lived spin coherence
Authors:
C. J. Stephen,
B. L. Green,
Y. N. D. Lekhai,
L. Weng,
P. Hill,
S. Johnson,
A. C. Frangeskou,
P. L. Diggle,
M. J. Strain,
E. Gu,
M. E. Newton,
J. M. Smith,
P. S. Salter,
G. W. Morley
Abstract:
Three-dimensional arrays of silicon transistors increase the density of bits. Solid-state qubits are much larger so could benefit even more from using the third dimension given that useful fault-tolerant quantum computing will require at least 100,000 physical qubits and perhaps one billion. Here we use laser writing to create 3D arrays of nitrogen-vacancy centre (NVC) qubits in diamond. This woul…
▽ More
Three-dimensional arrays of silicon transistors increase the density of bits. Solid-state qubits are much larger so could benefit even more from using the third dimension given that useful fault-tolerant quantum computing will require at least 100,000 physical qubits and perhaps one billion. Here we use laser writing to create 3D arrays of nitrogen-vacancy centre (NVC) qubits in diamond. This would allow 5 million qubits inside a commercially available 4.5x4.5x0.5 mm diamond based on five nuclear qubits per NVC and allowing $(10 μm)^3$ per NVC to leave room for our laser-written electrical control. The spin coherence times we measure are an order of magnitude longer than previous laser-written qubits and at least as long as non-laser-written NVC. As well as NVC quantum computing, quantum communication and nanoscale sensing could benefit from the same platform. Our approach could also be extended to other qubits in diamond and silicon carbide.
△ Less
Submitted 10 July, 2018;
originally announced July 2018.
-
Optical properties of Xe color centers in diamond
Authors:
Russell Sandstrom,
Li Ke,
Aiden Martin,
Ziyu Wang,
Mehran Kianinia,
Ben Green,
Weibo Gao,
Igor Aharonovich
Abstract:
Optical properties of color centers in diamond have been the subject of intense research due to their promising applications in quantum photonics. In this work we study the optical properties of Xe related color centers implanted into nitrogen rich (type IIA) and an ultrapure, electronic grade diamond. The Xe defect has two zero phonon lines at ~ 794 and 811 nm, which can be effectively excited us…
▽ More
Optical properties of color centers in diamond have been the subject of intense research due to their promising applications in quantum photonics. In this work we study the optical properties of Xe related color centers implanted into nitrogen rich (type IIA) and an ultrapure, electronic grade diamond. The Xe defect has two zero phonon lines at ~ 794 and 811 nm, which can be effectively excited using both green and red excitation, however, its emission in the nitrogen rich diamond is brighter. Near resonant excitation is performed at cryogenic temperatures and luminescence is probed under strong magnetic field. Our results are important towards the understanding of the Xe related defect and other near infrared color centers in diamond.
△ Less
Submitted 30 March, 2017;
originally announced April 2017.
-
Laser writing of coherent colour centres in diamond
Authors:
Yu-Chen Chen,
Patrick S. Salter,
Sebastian Knauer,
Laiyi Weng,
Angelo C. Frangeskou,
Colin J. Stephen,
Philip R. Dolan,
Sam Johnson,
Ben L. Green,
Gavin W. Morley,
Mark E. Newton,
John G. Rarity,
Martin J. Booth,
Jason M. Smith
Abstract:
Optically active point defects in crystals have gained widespread attention as photonic systems that can find use in quantum information technologies. However challenges remain in the placing of individual defects at desired locations, an essential element of device fabrication. Here we report the controlled generation of single nitrogen-vacancy (NV) centres in diamond using laser writing. The use…
▽ More
Optically active point defects in crystals have gained widespread attention as photonic systems that can find use in quantum information technologies. However challenges remain in the placing of individual defects at desired locations, an essential element of device fabrication. Here we report the controlled generation of single nitrogen-vacancy (NV) centres in diamond using laser writing. The use of aberration correction in the writing optics allows precise positioning of vacancies within the diamond crystal, and subsequent annealing produces single NV centres with up to 45% success probability, within about 200 nm of the desired position. Selected NV centres fabricated by this method display stable, coherent optical transitions at cryogenic temperatures, a pre-requisite for the creation of distributed quantum networks of solid-state qubits. The results illustrate the potential of laser writing as a new tool for defect engineering in quantum technologies.
△ Less
Submitted 16 June, 2016;
originally announced June 2016.
-
Optical nanoscopy of transient states in condensed matter
Authors:
Frederik Kuschewski,
Susanne C. Kehr,
Bert Green,
Christian Bauer,
Michael Gensch,
Lukas M. Eng
Abstract:
Recently, the fundamental and nanoscale understanding of complex phenomena in materials research and the life sciences, witnessed considerable progress. However, elucidating the underlying mechanisms, governed by entangled degrees of freedom such as lattice, spin, orbit, and charge for solids or conformation, electric potentials, and ligands for proteins, has remained challenging. Techniques that…
▽ More
Recently, the fundamental and nanoscale understanding of complex phenomena in materials research and the life sciences, witnessed considerable progress. However, elucidating the underlying mechanisms, governed by entangled degrees of freedom such as lattice, spin, orbit, and charge for solids or conformation, electric potentials, and ligands for proteins, has remained challenging. Techniques that allow for distinguishing between different contributions to these processes are hence urgently required. In this paper we demonstrate the application of scattering-type scanning near-field optical microscopy (s-SNOM) as a novel type of nano-probe for tracking transient states of matter. We introduce a sideband-demodulation technique that allows for probing exclusively the stimuli-induced change of near-field optical properties. We exemplify this development by inspecting the decay of an electron-hole plasma generated in SiGe thin films through near-infrared laser pulses. Our approach can universally be applied to optically track ultrafast/-slow processes over the whole spectral range from UV to THz frequencies.
△ Less
Submitted 3 August, 2015;
originally announced August 2015.
-
Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
J. Schlereth,
L. Xia,
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
G. Eigen,
Y. Mikami,
T. Price,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
C. Cârloganu,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh
, et al. (127 additional authors not shown)
Abstract:
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable ove…
▽ More
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.
△ Less
Submitted 8 May, 2015; v1 submitted 26 November, 2014;
originally announced November 2014.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
Development of a modular and scalable data acquisition system for calorimeters at a linear collider
Authors:
M. J. Goodrick,
L. B. A. Hommels,
R. Shaw,
D. R. Ward,
D. S. Bailey,
M. Kelly,
V. Boisvert,
B. Green,
M. G. Green,
A. Misiejuk,
T. Wu,
V. Bartsch,
M. Postranecky,
M. Warren,
M. Wing
Abstract:
A data acquisition (DAQ) system has been developed which will read out and control calorimeters serving as prototype systems for a future detector at an electron-positron linear collider. This is a modular, flexible and scalable DAQ system in which the hardware and signals are standards-based, using FPGAs and serial links. The idea of a backplaneless system was also pursued with a commercial devel…
▽ More
A data acquisition (DAQ) system has been developed which will read out and control calorimeters serving as prototype systems for a future detector at an electron-positron linear collider. This is a modular, flexible and scalable DAQ system in which the hardware and signals are standards-based, using FPGAs and serial links. The idea of a backplaneless system was also pursued with a commercial development board housed in a PC and a chain of concentrator cards between it and the detector forming the basis of the system. As well as describing the concept and performance of the system, its merits and disadvantages are discussed.
△ Less
Submitted 4 October, 2011; v1 submitted 29 June, 2011;
originally announced June 2011.