Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
A multilayer surface detector for ultracold neutrons
Authors:
Zhehui Wang,
M. A. Hoffbauer,
C. L. Morris,
N. B. Callahan,
E. R. Adamek,
J. D. Bacon,
M. Blatnik,
A. E. Brandt,
L. J. Broussard,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
J. Gao,
F. E. Gray,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
C. -Y. Liu,
M. Makela,
J. C. Ramsey,
R. W. Pattie, Jr.,
D. J. Salvat,
A. Saunders
, et al. (11 additional authors not shown)
Abstract:
A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is sufficient to detect the charged particles from the $^{10}$B(n,$α$)$^7$Li neutron-capture reaction, while thin enough so that ample light due to $α$ and $^7$Li escap…
▽ More
A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is sufficient to detect the charged particles from the $^{10}$B(n,$α$)$^7$Li neutron-capture reaction, while thin enough so that ample light due to $α$ and $^7$Li escapes for detection by photomultiplier tubes. One-hundred-nm thick $^{10}$B layer gives high UCN detection efficiency, as determined by the mean UCN kinetic energy, detector materials and others. Low background, including negligible sensitivity to ambient neutrons, has also been verified through pulse-shape analysis and comparisons with other existing $^3$He and $^{10}$B detectors. This type of detector has been configured in different ways for UCN flux monitoring, development of UCN guides and neutron lifetime research.
△ Less
Submitted 24 April, 2015; v1 submitted 11 March, 2015;
originally announced March 2015.
-
Measurement of the Formation Rate of Muonic Hydrogen Molecules
Authors:
MuCap Collaboration,
V. A. Andreev,
T. I. Banks,
R. M. Carey,
T. A. Case,
S. M. Clayton,
K. M. Crowe,
J. Deutsch,
J. Egger,
S. J. Freedman,
V. A. Ganzha,
T. Gorringe,
F. E. Gray,
D. W. Hertzog,
M. Hildebrandt,
P. Kammel,
B. Kiburg,
S. Knaack,
P. A. Kravtsov,
A. G. Krivshich,
B. Lauss,
K. R. Lynch,
E. M. Maev,
O. E. Maev,
F. Mulhauser
, et al. (11 additional authors not shown)
Abstract:
Background: The rate λ_ppμ characterizes the formation of ppμ molecules in collisions of muonic pμ atoms with hydrogen. In measurements of the basic weak muon capture reaction on the proton to determine the pseudoscalar coupling g_P, capture occurs from both atomic and molecular states. Thus knowledge of λ_ppμ is required for a correct interpretation of these experiments.
Purpose: Recently the M…
▽ More
Background: The rate λ_ppμ characterizes the formation of ppμ molecules in collisions of muonic pμ atoms with hydrogen. In measurements of the basic weak muon capture reaction on the proton to determine the pseudoscalar coupling g_P, capture occurs from both atomic and molecular states. Thus knowledge of λ_ppμ is required for a correct interpretation of these experiments.
Purpose: Recently the MuCap experiment has measured the capture rate Λ_S from the singlet pμ atom, employing a low density active target to suppress ppμ formation (PRL 110, 12504 (2013)). Nevertheless, given the unprecedented precision of this experiment, the existing experimental knowledge in λ_ppμ had to be improved.
Method: The MuCap experiment derived the weak capture rate from the muon disappearance rate in ultra-pure hydrogen. By do** the hydrogen with 20 ppm of argon, a competing process to ppμ formation was introduced, which allowed the extraction of λ_ppμ from the observed time distribution of decay electrons.
Results: The ppμ formation rate was measured as λ_ppμ= (2.01 +- 0.06(stat) +- 0.03(sys)) 10^6 s^-1. This result updates the λ_ppμ value used in the above mentioned MuCap publication.
Conclusions: The 2.5x higher precision compared to earlier experiments and the fact that the measurement was performed at nearly identical conditions to the main data taking, reduces the uncertainty induced by λ_ppμ to a minor contribution to the overall uncertainty of Λ_S and g_P, as determined in MuCap. Our final value for λ_ppμ shifts Λ_S and g_P by less than one tenth of their respective uncertainties compared to our results published earlier.
△ Less
Submitted 3 February, 2015;
originally announced February 2015.
-
A high-pressure hydrogen time projection chamber for the MuCap experiment
Authors:
J. Egger,
D. Fahrni,
M. Hildebrandt,
A. Hofer,
L. Meier,
C. Petitjean,
V. A. Andreev,
T. I. Banks,
S. M. Clayton,
V. A. Ganzha,
F. E. Gray,
P. Kammel,
B. Kiburg,
P. A. Kravtsov,
A. G. Krivshich,
B. Lauss,
E. M. Maev,
O. E. Maev,
G. Petrov,
G. G. Semenchuk,
A. A. Vasilyev,
A. A. Vorobyov,
M. E. Vznuzdaev,
P. Winter
Abstract:
The MuCap experiment at the Paul Scherrer Institute performed a high-precision measurement of the rate of the basic electroweak process of nuclear muon capture by the proton, $μ^- + p \rightarrow n + ν_μ$. The experimental approach was based on the use of a time projection chamber (TPC) that operated in pure hydrogen gas at a pressure of 10 bar and functioned as an active muon stop** target. The…
▽ More
The MuCap experiment at the Paul Scherrer Institute performed a high-precision measurement of the rate of the basic electroweak process of nuclear muon capture by the proton, $μ^- + p \rightarrow n + ν_μ$. The experimental approach was based on the use of a time projection chamber (TPC) that operated in pure hydrogen gas at a pressure of 10 bar and functioned as an active muon stop** target. The TPC detected the tracks of individual muon arrivals in three dimensions, while the trajectories of outgoing decay (Michel) electrons were measured by two surrounding wire chambers and a plastic scintillation hodoscope. The muon and electron detectors together enabled a precise measurement of the $μp$ atom's lifetime, from which the nuclear muon capture rate was deduced. The TPC was also used to monitor the purity of the hydrogen gas by detecting the nuclear recoils that follow muon capture by elemental impurities. This paper describes the TPC design and performance in detail.
△ Less
Submitted 19 May, 2014; v1 submitted 12 May, 2014;
originally announced May 2014.
-
Design and operation of a cryogenic charge-integrating preamplifier for the MuSun experiment
Authors:
R. A. Ryan,
F. Wauters,
F. E. Gray,
P. Kammel,
A. Nadtochy,
D. Peterson,
T. van Wechel,
E. Gross,
M. Gubanich,
L. Kochenda,
P. Kravtsov,
M. H. Murray,
D. Orozco,
R. Osofsky,
G. E. Petrov,
J. D. Phillips,
J. Stroud,
V. Trofimov,
A. Vasilyev,
M. Vznuzdaev
Abstract:
The central detector in the MuSun experiment is a pad-plane time projection ionization chamber that operates without gas amplification in deuterium at 31 K; it is used to measure the rate of the muon capture process $μ^- + d \rightarrow n + n + ν_μ$. A new charge-sensitive preamplifier, operated at 140 K, has been developed for this detector. It achieved a resolution of 4.5 keV(D$_2$) or 120…
▽ More
The central detector in the MuSun experiment is a pad-plane time projection ionization chamber that operates without gas amplification in deuterium at 31 K; it is used to measure the rate of the muon capture process $μ^- + d \rightarrow n + n + ν_μ$. A new charge-sensitive preamplifier, operated at 140 K, has been developed for this detector. It achieved a resolution of 4.5 keV(D$_2$) or 120 $e^-$ RMS with zero detector capacitance at 1.1 $μ$s integration time in laboratory tests. In the experimental environment, the electronic resolution is 10 keV(D$_2$) or 250 $e^-$ RMS at a 0.5 $μ$s integration time. The excellent energy resolution of this amplifier has enabled discrimination between signals from muon-catalyzed fusion and muon capture on chemical impurities, which will precisely determine systematic corrections due to these processes. It is also expected to improve the muon tracking and determination of the stop** location.
△ Less
Submitted 12 May, 2014; v1 submitted 11 April, 2014;
originally announced April 2014.
-
Detailed Report of the MuLan Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant
Authors:
V. Tishchenko,
S. Battu,
R. M. Carey,
D. B. Chitwood,
J. Crnkovic,
P. T. Debevec,
S. Dhamija,
W. Earle,
A. Gafarov,
K. Giovanetti,
T. P. Gorringe,
F. E. Gray,
Z. Hartwig,
D. W. Hertzog,
B. Johnson,
P. Kammel,
B. Kiburg,
S. Kizilgul,
J. Kunkle,
B. Lauss,
I. Logashenko,
K. R. Lynch,
R. McNabb,
J. P. Miller,
F. Mulhauser
, et al. (8 additional authors not shown)
Abstract:
We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target wi…
▽ More
We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target with a ~4 kG internal magnetic field and a crystal quartz target in a 130 G external magnetic field. Approximately 1.6 x 10^{12} positrons were accumulated and together the data yield a muon lifetime of tau_{mu}(MuLan) = 2196980.3(2.2) ps (1.0 ppm), thirty times more precise than previous generations of lifetime experiments. The lifetime measurement yields the most accurate value of the Fermi constant G_F (MuLan) = 1.1663787(6) x 10^{-5} GeV^{-2} (0.5 ppm). It also enables new precision studies of weak interactions via lifetime measurements of muonic atoms.
△ Less
Submitted 5 November, 2012;
originally announced November 2012.