Forward Instrumentation for ILC Detectors
Authors:
Halina Abramowicz,
Angel Abusleme,
Konstantin Afanaciev,
Jonathan Aguilar,
Prasoon Ambalathankandy,
Philip Bambade,
Matthias Bergholz,
Ivanka Bozovic-Jelisavcic,
Elena Castro,
Georgy Chelkov,
Cornelia Coca,
Witold Daniluk,
Angelo Dragone,
Laurentiu Dumitru,
Konrad Elsener,
Igor Emeliantchik,
Tomasz Fiutowski,
Mikhail Gostkin,
Christian Grah,
Grzegorz Grzelak,
Gunter Haller,
Hans Henschel,
Alexandr Ignatenko,
Marek Idzik,
Kazutoshi Ito
, et al. (33 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions wil…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions will allow a fast luminosity estimate and the determination of beam parameters. The sensors of this calorimeter must be radiation hard. Both devices will improve the hermeticity of the detector in the search for new particles. Finely segmented and very compact calorimeters will match the requirements. Due to the high occupancy fast front-end electronics is needed. The design of the calorimeters developed and optimised with Monte Carlo simulations is presented. Sensors and readout electronics ASICs have been designed and prototypes are available. Results on the performance of these major components are summarised.
△ Less
Submitted 3 November, 2010; v1 submitted 13 September, 2010;
originally announced September 2010.
-
Test Beam Results of Geometry Optimized Hybrid Pixel Detectors
Authors:
K. -H. Becks,
P. Gerlach,
C. Grah,
P. Maettig,
T. Rohe
Abstract:
The Multi-Chip-Module-Deposited (MCM-D) technique has been used to build hybrid pixel detector assemblies. This paper summarises the results of an analysis of data obtained in a test beam campaign at CERN. Here, single chip hybrids made of ATLAS pixel prototype read-out electronics and special sensor tiles were used. They were prepared by the Fraunhofer Institut fuer Zuverlaessigkeit und Mikroin…
▽ More
The Multi-Chip-Module-Deposited (MCM-D) technique has been used to build hybrid pixel detector assemblies. This paper summarises the results of an analysis of data obtained in a test beam campaign at CERN. Here, single chip hybrids made of ATLAS pixel prototype read-out electronics and special sensor tiles were used. They were prepared by the Fraunhofer Institut fuer Zuverlaessigkeit und Mikrointegration, IZM, Berlin, Germany. The sensors feature an optimized sensor geometry called equal sized bricked. This design enhances the spatial resolution for double hits in the long direction of the sensor cells.
△ Less
Submitted 7 November, 2005;
originally announced November 2005.
-
Beam Calorimeter Technologies
Authors:
R. Dollan,
Ch. Grah,
E. Kuznetsova,
W. Lange,
W. Lohmann,
A. Stahl,
K. Afanaciev,
V. Drugakov,
I. Emeliantchik
Abstract:
Two different technologies are considered for the Beam Calorimeters of the ILC detector. Simulation studies of the performance have been done for a diamond-tungsten sandwich calorimeter and for a homogeneous heavy element crystal calorimeter with optical fiber readout. Studies of the stability and the linearity of a polycrystalline diamond were done for the diamond-tungsten option. For the heavy…
▽ More
Two different technologies are considered for the Beam Calorimeters of the ILC detector. Simulation studies of the performance have been done for a diamond-tungsten sandwich calorimeter and for a homogeneous heavy element crystal calorimeter with optical fiber readout. Studies of the stability and the linearity of a polycrystalline diamond were done for the diamond-tungsten option. For the heavy crystal option the light yield reduction due to the wavelength shifting fiber readout was studied.
△ Less
Submitted 25 July, 2005; v1 submitted 1 July, 2005;