-
Shower Separation in Five Dimensions for Highly Granular Calorimeters using Machine Learning
Authors:
S. Lai,
J. Utehs,
A. Wilhahn,
M. C. Fouz,
O. Bach,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
D. Heuchel,
A. Irles,
K. Krüger,
J. Kvasnicka,
S. Lu,
C. Neubüser,
A. Provenza,
M. Reinecke,
F. Sefkow,
S. Schuwalow,
M. De Silva,
Y. Sudo,
H. L. Tran,
L. Liu,
R. Masuda
, et al. (26 additional authors not shown)
Abstract:
To achieve state-of-the-art jet energy resolution for Particle Flow, sophisticated energy clustering algorithms must be developed that can fully exploit available information to separate energy deposits from charged and neutral particles. Three published neural network-based shower separation models were applied to simulation and experimental data to measure the performance of the highly granular…
▽ More
To achieve state-of-the-art jet energy resolution for Particle Flow, sophisticated energy clustering algorithms must be developed that can fully exploit available information to separate energy deposits from charged and neutral particles. Three published neural network-based shower separation models were applied to simulation and experimental data to measure the performance of the highly granular CALICE Analogue Hadronic Calorimeter (AHCAL) technological prototype in distinguishing the energy deposited by a single charged and single neutral hadron for Particle Flow. The performance of models trained using only standard spatial and energy and charged track position information from an event was compared to models trained using timing information available from AHCAL, which is expected to improve sensitivity to shower development and, therefore, aid in clustering. Both simulation and experimental data were used to train and test the models and their performances were compared. The best-performing neural network achieved significantly superior event reconstruction when timing information was utilised in training for the case where the charged hadron had more energy than the neutral one, motivating temporally sensitive calorimeters. All models under test were observed to tend to allocate energy deposited by the more energetic of the two showers to the less energetic one. Similar shower reconstruction performance was observed for a model trained on simulation and applied to data and a model trained and applied to data.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
Enhanced and Robust Contrast in CEST MRI: Saturation Pulse Shape Design via Optimal Control
Authors:
Clemens Stilianu,
Christina Graf,
Markus Huemer,
Clemens Diwoky,
Martin Soellradl,
Armin Rund,
Moritz Zaiss,
Rudolf Stollberger
Abstract:
Purpose: To employ optimal control for the numerical design of CEST saturation pulses to maximize contrast and stability against $B_0$ inhomogeneities.
Theory and Methods: We applied an optimal control framework for the design pulse shapes for CEST saturation pulse trains. The cost functional minimized both the pulse energy and the discrepancy between the corresponding CEST spectrum and the targ…
▽ More
Purpose: To employ optimal control for the numerical design of CEST saturation pulses to maximize contrast and stability against $B_0$ inhomogeneities.
Theory and Methods: We applied an optimal control framework for the design pulse shapes for CEST saturation pulse trains. The cost functional minimized both the pulse energy and the discrepancy between the corresponding CEST spectrum and the target spectrum based on a continuous RF pulse. The optimization is subject to hardware limitations. In measurements on a 7 T preclinical scanner, the optimal control pulses were compared to continuous-wave and Gaussian saturation methods. We conducted a comparison of the optimal control pulses were compared to with Gaussian, block pulse trains, and adiabatic spin-lock pulses.
Results: The optimal control pulse train demonstrated saturation levels comparable to continuous-wave saturation and surpassed Gaussian saturation by up to 50 \% in phantom measurements. In phantom measurements at 3 T the optimized pulses not only showcased the highest CEST contrast, but also the highest stability against field inhomogeneities. In contrast, block pulse saturation resulted in severe artifacts. Dynamic Bloch-McConnell simulations were employed to identify the source of these artifacts, and underscore the $B_0$ robustness of the optimized pulses.
Conclusion: In this work, it was shown that a substantial improvement in pulsed saturation CEST imaging can be achieved by using Optimal Control design principles. It is possible to overcome the sensitivity of saturation to B0 inhomogeneities while achieving CEST contrast close to continuous wave saturation.
△ Less
Submitted 29 April, 2024;
originally announced April 2024.
-
Software Compensation for Highly Granular Calorimeters using Machine Learning
Authors:
S. Lai,
J. Utehs,
A. Wilhahn,
O. Bach,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
D. Heuchel,
A. Irles,
K. Krüger,
J. Kvasnicka,
S. Lu,
C. Neubüser,
A. Provenza,
M. Reinecke,
F. Sefkow,
S. Schuwalow,
M. De Silva,
Y. Sudo,
H. L. Tran,
E. Buhmann,
E. Garutti,
S. Huck
, et al. (39 additional authors not shown)
Abstract:
A neural network for software compensation was developed for the highly granular CALICE Analogue Hadronic Calorimeter (AHCAL). The neural network uses spatial and temporal event information from the AHCAL and energy information, which is expected to improve sensitivity to shower development and the neutron fraction of the hadron shower. The neural network method produced a depth-dependent energy w…
▽ More
A neural network for software compensation was developed for the highly granular CALICE Analogue Hadronic Calorimeter (AHCAL). The neural network uses spatial and temporal event information from the AHCAL and energy information, which is expected to improve sensitivity to shower development and the neutron fraction of the hadron shower. The neural network method produced a depth-dependent energy weighting and a time-dependent threshold for enhancing energy deposits consistent with the timescale of evaporation neutrons. Additionally, it was observed to learn an energy-weighting indicative of longitudinal leakage correction. In addition, the method produced a linear detector response and outperformed a published control method regarding resolution for every particle energy studied.
△ Less
Submitted 7 March, 2024;
originally announced March 2024.
-
Rational Approximation of Golden Angles: Accelerated Reconstructions with Simple and Numerically Reproducible Radial Sampling
Authors:
Nick Scholand,
Philip Schaten,
Christina Graf,
Daniel Mackner,
H. Christian M. Holme,
Moritz Blumenthal,
Andrew Mao,
Jakob Assländer,
Martin Uecker
Abstract:
Purpose: To develop a generic radial sampling scheme that combines the advantages of golden ratio sampling with simplicity of equidistant angular patterns. The irrational angle between consecutive spokes in golden ratio based sampling schemes enables a flexible retrospective choice of temporal resolution, while preserving good coverage of k-space for each individual bin. Nevertheless, irrational i…
▽ More
Purpose: To develop a generic radial sampling scheme that combines the advantages of golden ratio sampling with simplicity of equidistant angular patterns. The irrational angle between consecutive spokes in golden ratio based sampling schemes enables a flexible retrospective choice of temporal resolution, while preserving good coverage of k-space for each individual bin. Nevertheless, irrational increments prohibit precomputation of the point-spread function (PSF), can lead to numerical problems, and require more complex processing steps. To avoid these problems, a new sampling scheme based on a rational approximation of golden angles (RAGA) is developed.
Methods: The theoretical properties of RAGA sampling are mathematically derived. Sidelobe-to-peak ratios (SPR) are numerically computed and compared to the corresponding golden ratio sampling schemes. The sampling scheme is implemented in the BART toolbox and in a radial gradient-echo sequence. Feasibility is shown for quantitative imaging in a phantom and a cardiac scan of a healthy volunteer.
Results: RAGA sampling can accurately approximate golden ratio sampling and has almost identical PSF and SPR. In contrast to golden ratio sampling, each frame can be reconstructed with the same equidistant trajectory using different sampling masks, and the angle of each acquired spoke can be encoded as a small index, which simplifies processing of the acquired data.
Conclusion: RAGA sampling provides the advantages of golden ratio sampling while simplifying data processing, rendering it a valuable tool for dynamic and quantitative MRI.
△ Less
Submitted 30 May, 2024; v1 submitted 5 January, 2024;
originally announced January 2024.
-
Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
J. P. Figueiredo de sa Sousa de Almeida,
P. G. Dias de Almeida,
A. Alpana,
M. Alyari,
I. Andreev,
U. Aras,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Banerjee,
P. DeBarbaro,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (435 additional authors not shown)
Abstract:
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing med…
▽ More
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.
△ Less
Submitted 27 May, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Description and stability of a RPC-based calorimeter in electromagnetic and hadronic shower environments
Authors:
D. Boumediene,
V. Francais,
J. Apostolakis,
G. Folger,
A. Ribon,
E. Sicking,
K. Goto,
K. Kawagoe,
M. Kuhara,
T. Suehara,
T. Yoshioka,
A. **ault,
M. Tytgat,
G. Garillot,
G. Grenier,
T. Kurca,
I. Laktineh,
B. Liu,
B. Li,
L. Mirabito,
E. Calvo Alamillo,
C. Carrillo,
M. C. Fouz,
H. Garcia Cabrera,
J. Marin
, et al. (14 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadron Calorimeter technological prototype completed in 2011 is a sampling calorimeter using Glass Resistive Plate Chamber (GRPC) detectors as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed in 2015 to beams of muons, electron…
▽ More
The CALICE Semi-Digital Hadron Calorimeter technological prototype completed in 2011 is a sampling calorimeter using Glass Resistive Plate Chamber (GRPC) detectors as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed in 2015 to beams of muons, electrons, and pions of different energies at the CERN Super Proton Synchrotron. The use of this technology for future experiments requires a reliable simulation of its response that can predict its performance. GEANT4 combined with a digitization algorithm was used to simulate the prototype. It describes the full path of the signal: showering, gas avalanches, charge induction, and hit triggering. The simulation was tuned using muon tracks and electromagnetic showers for accounting for detector inhomogeneity and tested on hadronic showers collected in the test beam. This publication describes developments of the digitization algorithm. It is used to predict the stability of the detector performance against various changes in the data-taking conditions, including temperature, pressure, magnetic field, GRPC width variations, and gas mixture variations. These predictions are confronted with test beam data and provide an attempt to explain the detector properties. The data-taking conditions such as temperature and potential detector inhomogeneities affect energy density measurements but have a small impact on detector efficiency.
△ Less
Submitted 21 March, 2023; v1 submitted 13 July, 2022;
originally announced July 2022.
-
Time-assisted energy reconstruction in a highly-granular hadronic calorimeter
Authors:
Christian Graf,
Frank Simon
Abstract:
The software compensation algorithms developed for the CALICE Analog Hadron Calorimeter are extended to incorporate time information on the cell level, and the performance is studied in GEANT4 simulations with a detector model of a highly-granular SiPM-on-tile calorimeter. The addition of nanosecond-level time resolution is found to result in significant improvement of the energy resolution by app…
▽ More
The software compensation algorithms developed for the CALICE Analog Hadron Calorimeter are extended to incorporate time information on the cell level, and the performance is studied in GEANT4 simulations with a detector model of a highly-granular SiPM-on-tile calorimeter. The addition of nanosecond-level time resolution is found to result in significant improvement of the energy resolution by approximately 3% to 4% for local software compensation compared to the software compensation based on local energy density alone, with further improvement possible with better timing resolution. The high correlation of energy density and time variables show that both provide sensitivity to correlated underlying shower features, which limits the potential of timing information when used as a global rather than a local variable.
△ Less
Submitted 28 August, 2022; v1 submitted 2 March, 2022;
originally announced March 2022.
-
Energy reconstruction of hadronic showers at the CERN PS and SPS using the Semi-Digital Hadronic Calorimeter
Authors:
I. Laktineh,
B. Liu,
D. Boumediene,
Y. W. Baek,
D-W. Kim,
S. C. Lee,
B. G. Min,
S. W. Park,
Y. Deguchi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
L. Caponetto,
C. Combaret,
G. Garillot,
G. Grenier,
J-C. Ianigro,
T. Kurca,
I. Laktineh,
B. Liu,
B. Li,
N. Lumb
, et al. (53 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL is a sampling calorimeter using stainless steel for absorber and Glass Resistive Plate Chambers (GRPC) as a sensitive medium. The GRPC are read out by 1~cm…
▽ More
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL is a sampling calorimeter using stainless steel for absorber and Glass Resistive Plate Chambers (GRPC) as a sensitive medium. The GRPC are read out by 1~cm $\times$ 1~cm pickup pads combined to a multi-threshold electronics. The prototype was exposed to hadron beams in both the CERN PS and the SPS beamlines in 2015 allowing the test of the SDHCAL in a large energy range from 3~GeV to 80~GeV. After introducing the method used to select the hadrons of our data and reject the muon and electron contamination, we present the energy reconstruction approach that we apply to the data collected from both beamlines and we discuss the response linearity and the energy resolution of the SDHCAL. The results obtained in the two beamlines confirm the excellent SDHCAL performance observed with the data collected with the same prototype in the SPS beamline in 2012. They also show the stability of the SDHCAL in different beam conditions and different time periods.
△ Less
Submitted 19 February, 2022;
originally announced February 2022.
-
Few-femtosecond resolved imaging of laser-driven nanoplasma expansion
Authors:
C. Peltz,
J. A. Powell,
P. Rupp,
A Summers,
T. Gorkhover,
M. Gallei,
I. Halfpap,
E. Antonsson,
B. Langer,
C. Trallero-Herrero,
C. Graf,
D. Ray,
Q. Liu,
T. Osipov,
M. Bucher,
K. Ferguson,
S. Möller,
S. Zherebtsov,
D. Rolles,
E. Rühl,
G. Coslovich,
R. N. Coffee,
C. Bostedt,
A. Rudenko,
M. F. Kling
, et al. (1 additional authors not shown)
Abstract:
The free expansion of a planar plasma surface is a fundamental non-equilibrium process relevant for various fields but as-yet experimentally still difficult to capture. The significance of the associated spatiotemporal plasma motion ranges from astrophysics and controlled fusion to laser machining, surface high-harmonic generation, plasma mirrors, and laser-particle acceleration. Here, we show tha…
▽ More
The free expansion of a planar plasma surface is a fundamental non-equilibrium process relevant for various fields but as-yet experimentally still difficult to capture. The significance of the associated spatiotemporal plasma motion ranges from astrophysics and controlled fusion to laser machining, surface high-harmonic generation, plasma mirrors, and laser-particle acceleration. Here, we show that x-ray coherent diffractive imaging can surpass existing approaches and enables the quantitative real-time analysis of the sudden free expansion of nanoplasmas. For laser-ionized SiO$_2$ nanospheres, we resolve the formation of the emerging nearly self-similar plasma profile evolution and expose the so far inaccessible shell-wise expansion dynamics including the associated startup delay and rarefaction front velocity. Our results establish time-resolved diffractive imaging as an accurate quantitative diagnostic platform for tracing and characterizing plasma expansion and indicate the possibility to resolve various laser-driven processes including shock formation and wave-breaking phenomena with unprecedented resolution.
△ Less
Submitted 15 March, 2022; v1 submitted 20 September, 2021;
originally announced September 2021.
-
Particle Identification Using Boosted Decision Trees in the Semi-Digital Hadronic Calorimeter Prototype
Authors:
D. Boumediene,
A. **ault,
M. Tytgat,
B. Bilki,
D. Northacker,
Y. Onel,
G. Cho,
D-W. Kim,
S. C. Lee,
W. Park,
S. Vallecorsa,
Y. Deguchi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
L. Caponetto,
C. Combaret,
R. Ete G. Garillot,
G. Grenier,
J-C. Ianigro,
T. Kurca,
I. Laktineh
, et al. (65 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines…
▽ More
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines between 2012 and 2018. We present here a new method of particle identification within the SDHCAL using the Boosted Decision Trees (BDT) method applied to the data collected in 2015. The performance of the method is tested first with Geant4-based simulated events and then on the data collected by the SDHCAL in the energy range between 10 and 80~GeV with 10~GeV energy steps. The BDT method is then used to reject the electrons and muons that contaminate the SPS hadron beams.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
Detector Technologies for CLIC
Authors:
A. C. Abusleme Hoffman,
G. Parès,
T. Fritzsch,
M. Rothermund,
H. Jansen,
K. Krüger,
F. Sefkow,
A. Velyka,
J. Schwandt,
I. Perić,
L. Emberger,
C. Graf,
A. Macchiolo,
F. Simon,
M. Szalay,
N. van der Kolk,
H. Abramowicz,
Y. Benhammou,
O. Borysov,
M. Borysova,
A. Joffe,
S. Kananov,
A. Levy,
I. Levy,
G. Eigen
, et al. (107 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Stan…
▽ More
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.
△ Less
Submitted 7 May, 2019;
originally announced May 2019.
-
Characterisation of different stages of hadronic showers using the CALICE Si-W ECAL physics prototype
Authors:
CALICE Collaboration,
G. Eigen,
T. Price,
N. K. Watson,
A. Winter,
Y. Do,
A. Khan,
D. Kim,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
J. Apostolakis,
J. Giraud,
D. Grondin,
J. -Y. Hostachy,
O. Bach,
V. Bocharnikov,
E. Brianne
, et al. (81 additional authors not shown)
Abstract:
A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorith…
▽ More
A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorithm that reconstructs tracks within hadronic showers in a calorimeter in the absence of a magnetic field. The principle of carrying out detector monitoring and calibration using secondary tracks is also demonstrated.
△ Less
Submitted 18 September, 2019; v1 submitted 16 February, 2019;
originally announced February 2019.
-
Analysis of Testbeam Data of the Highly Granular RPC-Steel CALICE Digital Hadron Calorimeter and Validation of Geant4 Monte Carlo Models
Authors:
CALICE Collaboration,
M. Chefdeville,
J. Repond,
J. Schlereth,
J. R. Smith,
D. Trojand,
L. Xia,
Q. Zhang,
J. Apostolakis,
C. Grefe,
V. Ivantchenko,
G. Folger,
A. Ribon,
V. Uzhinskiy,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
O. Bach,
V. Bocharnikov,
E. Brianne,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
D. Heuchel
, et al. (71 additional authors not shown)
Abstract:
We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of…
▽ More
We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of $1\,\times\,1\,$cm$^{2}$ and a longitudinal segmentation of 38 layers, the calorimeter counted 350,208 readout channels, each read out with single-bit resolution (digital readout). The data were recorded in the Fermilab test beam in 2010-11. The analysis includes measurements of the calorimeter response and the energy resolution to positrons and muons, as well as detailed studies of various shower shape quantities. The results are compared to simulations based on Geant4, which utilise different electromagnetic and hadronic physics lists.
△ Less
Submitted 25 January, 2019;
originally announced January 2019.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Hadronic Energy Resolution of a Combined High Granularity Scintillator Calorimeter System
Authors:
CALICE Collaboration,
J. Repond,
L. Xia,
J. Apostolakis,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
D. Boumediene,
V. Francais,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
O. Bach,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Gttlicher,
O. Hartbrich F. Krivan,
K. Krüger,
J. Kvasnicka,
S. Lu,
C. Neubüser,
A. Provenza
, et al. (84 additional authors not shown)
Abstract:
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles.…
▽ More
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles. The results of a software compensation technique based on weighting according to hit energy are compared to those of a standard linear energy reconstruction. The results are compared to predictions of the GEANT4 physics lists QGSP_BERT_HP and FTFP_BERT_HP.
△ Less
Submitted 12 September, 2018; v1 submitted 11 September, 2018;
originally announced September 2018.
-
Performance of a Highly Granular Scintillator-SiPM Based Hadron Calorimeter Prototype in Strong Magnetic Fields
Authors:
Christian Graf
Abstract:
Within the CALICE collaboration, several concepts for the hadronic calorimeter of a future linear collider detector are studied. After having demonstrated the capabilities of the measurement methods in "physics prototypes", the focus now lies on improving their implementation in "engineering prototypes", that are scalable to the full linear collider detector. The Analog Hadron Calorimeter (AHCAL)…
▽ More
Within the CALICE collaboration, several concepts for the hadronic calorimeter of a future linear collider detector are studied. After having demonstrated the capabilities of the measurement methods in "physics prototypes", the focus now lies on improving their implementation in "engineering prototypes", that are scalable to the full linear collider detector. The Analog Hadron Calorimeter (AHCAL) concept is a sampling calorimeter of tungsten or steel absorber plates and plastic scintillator tiles read out by silicon photomultipliers (SiPMs) as active material. The front-end chips are integrated into the active layers of the calorimeter and are designed for minimizing power consumption by rapidly cycling the power according to the beam structure of a linear accelerator. The versatile electronics allows the prototype to be equipped with different types of scintillator tiles and SiPMs. A prototype with ~2200 channels, equipped with several types of scintillator tiles and SiPMs, was tested with muons and electrons in a 1.5 T magnet at the CERN SPS in May 2017 to establish the operational stability with power pulsing and the overall detector performance in a magnetic field.
△ Less
Submitted 10 November, 2017;
originally announced November 2017.
-
Demonstration of a switchable dam** system to allow low-noise operation of high-Q low-mass suspension systems
Authors:
Jan-Simon Hennig,
Bryan W. Barr,
Angus S. Bell,
William Cunningham,
Stefan L. Danilishin,
Peter Dupej,
Christian Graef,
Sabina H. Huttner,
Russell Jones,
Sean S. Leavey,
Daniela Pascucci,
Martin Sinclair,
Borja Sorazu,
Andrew Spencer,
Sebastian Steinlechner,
Kenneth A. Strain,
Jennifer Wright,
Teng Zhang,
Stefan Hild
Abstract:
Low mass suspension systems with high-Q pendulum stages are used to enable quantum radiation pressure noise limited experiments. Utilising multiple pendulum stages with vertical blade springs and materials with high quality factors provides attenuation of seismic and thermal noise, however dam** of these high-Q pendulum systems in multiple degrees of freedom is essential for practical implementa…
▽ More
Low mass suspension systems with high-Q pendulum stages are used to enable quantum radiation pressure noise limited experiments. Utilising multiple pendulum stages with vertical blade springs and materials with high quality factors provides attenuation of seismic and thermal noise, however dam** of these high-Q pendulum systems in multiple degrees of freedom is essential for practical implementation. Viscous dam** such as eddy-current dam** can be employed but introduces displacement noise from force noise due to thermal fluctuations in the dam** system. In this paper we demonstrate a passive dam** system with adjustable dam** strength as a solution for this problem that can be used for low mass suspension systems without adding additional displacement noise in science mode. We show a reduction of the dam** factor by a factor of 8 on a test suspension and provide a general optimisation for this system.
△ Less
Submitted 25 October, 2017; v1 submitted 24 October, 2017;
originally announced October 2017.
-
Construction and Response of a Highly Granular Scintillator-based Electromagnetic Calorimeter
Authors:
CALICE collaboration,
J. Repond,
L. Xia,
G. Eigen,
T. Price,
N. K. Watson,
A. Winter,
M. A. Thomson,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
F. Krivan,
K. Krüger,
S. Lu,
B. Lutz,
M. Reinecke,
F. Sefkow,
Y. Sudo,
H. L. Tran,
A. Kaplan,
H. -Ch. Schultz-Coulon
, et al. (57 additional authors not shown)
Abstract:
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab…
▽ More
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1\%, and the intrinsic energy resolution was determined to be $(12.5 \pm 0.1 (\mathrm{stat.}) \pm0.4 (\mathrm{syst.}))\%/\sqrt{E[\mathrm{GeV}]}\oplus (1.2 \pm 0.1(\mathrm{stat.})^{+0.6}_{-0.7}(\mathrm{syst.}))\%$, where the uncertainties correspond to statistical and systematic sources, respectively.
△ Less
Submitted 28 February, 2018; v1 submitted 22 July, 2017;
originally announced July 2017.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
GEO 600 and the GEO-HF upgrade program: successes and challenges
Authors:
K. L. Dooley,
J. R. Leong,
T. Adams,
C. Affeldt,
A. Bisht,
C. Bogan,
J. Degallaix,
C. Gräf,
S. Hild,
J. Hough,
A. Khalaidovski,
N. Lastzka,
J. Lough,
H. Lück,
D. Macleod,
L. Nuttall,
M. Prijatelj,
R. Schnabel,
E. Schreiber,
J. Slutsky,
B. Sorazu,
K. A. Strain,
H. Vahlbruch,
M. Was,
B. Willke
, et al. (3 additional authors not shown)
Abstract:
The German-British laser-interferometric gravitational wave detector GEO 600 is in its 14th year of operation since its first lock in 2001. After GEO 600 participated in science runs with other first-generation detectors, a program known as GEO-HF began in 2009. The goal was to improve the detector sensitivity at high frequencies, around 1 kHz and above, with technologically advanced yet minimally…
▽ More
The German-British laser-interferometric gravitational wave detector GEO 600 is in its 14th year of operation since its first lock in 2001. After GEO 600 participated in science runs with other first-generation detectors, a program known as GEO-HF began in 2009. The goal was to improve the detector sensitivity at high frequencies, around 1 kHz and above, with technologically advanced yet minimally invasive upgrades. Simultaneously, the detector would record science quality data in between commissioning activities. As of early 2014, all of the planned upgrades have been carried out and sensitivity improvements of up to a factor of four at the high-frequency end of the observation band have been achieved. Besides science data collection, an experimental program is ongoing with the goal to further improve the sensitivity and evaluate future detector technologies. We summarize the results of the GEO-HF program to date and discuss its successes and challenges.
△ Less
Submitted 19 January, 2016; v1 submitted 1 October, 2015;
originally announced October 2015.
-
Local-Oscillator Noise Coupling in Balanced Homodyne Readout for Advanced Gravitational Wave Detectors
Authors:
Sebastian Steinlechner,
Bryan W Barr,
Angus S Bell,
Stefan L Danilishin,
Andreas Gläfke,
Christian Gräf,
Jan-Simon Hennig,
E Alasdair Houston,
Sabina H Huttner,
Sean S Leavey,
Daniela Pascucci,
Borja Sorazu,
Andrew Spencer,
Kenneth A Strain,
Jennifer Wright,
Stefan Hild
Abstract:
The second generation of interferometric gravitational wave detectors are quickly approaching their design sensitivity. For the first time these detectors will become limited by quantum back-action noise. Several back-action evasion techniques have been proposed to further increase the detector sensitivity. Since most proposals rely on a flexible readout of the full amplitude- and phase-quadrature…
▽ More
The second generation of interferometric gravitational wave detectors are quickly approaching their design sensitivity. For the first time these detectors will become limited by quantum back-action noise. Several back-action evasion techniques have been proposed to further increase the detector sensitivity. Since most proposals rely on a flexible readout of the full amplitude- and phase-quadrature space of the output light field, balanced homodyne detection is generally expected to replace the currently used DC readout. Up to now, little investigation has been undertaken into how balanced homodyne detection can be successfully transferred from its ubiquitous application in table-top quantum optics experiments to large-scale interferometers with suspended optics. Here we derive implementation requirements with respect to local oscillator noise couplings and highlight potential issues with the example of the Glasgow Sagnac Speed Meter experiment, as well as for a future upgrade to the Advanced LIGO detectors.
△ Less
Submitted 24 June, 2015;
originally announced June 2015.
-
Upper Limit to the Transverse to Longitudinal Motion Coupling of a Waveguide Mirror
Authors:
S. Leavey,
B. W. Barr,
A. S. Bell,
E-B. Kley,
N. Gordon,
C. Gräf,
S. Hild,
S. H. Huttner,
S. Kroker,
J. Macarthur,
C. Messenger,
M. Pitkin,
B. Sorazu,
K. Strain,
A. Tünnermann
Abstract:
Waveguide mirrors possess nano-structured surfaces which can potentially provide a significant reduction in thermal noise over conventional dielectric mirrors. To avoid introducing additional phase noise from motion of the mirror transverse to the reflected light, however, they must possess a mechanism to suppress the phase effects associated with the incident light translating across the nano-str…
▽ More
Waveguide mirrors possess nano-structured surfaces which can potentially provide a significant reduction in thermal noise over conventional dielectric mirrors. To avoid introducing additional phase noise from motion of the mirror transverse to the reflected light, however, they must possess a mechanism to suppress the phase effects associated with the incident light translating across the nano-structured surface. It has been shown that with carefully chosen parameters this additional phase noise can be suppressed. We present an experimental measurement of the coupling of transverse to longitudinal displacements in such a waveguide mirror designed for 1064 nm light. We place an upper limit on the level of measured transverse to longitudinal coupling of one part in seventeen thousand with 95% confidence, representing a significant improvement over a previously measured grating mirror.
△ Less
Submitted 10 August, 2015; v1 submitted 6 October, 2014;
originally announced October 2014.
-
Design of a speed meter interferometer proof-of-principle experiment
Authors:
C. Gräf,
B. W. Barr,
A. S. Bell,
F. Campbell,
A. V. Cumming,
S. L. Danilishin,
N. A. Gordon,
G. D. Hammond,
J. Hennig,
E. A. Houston,
S. H. Huttner,
R. A. Jones,
S. S. Leavey,
H. Lück,
J. Macarthur,
M. Marwick,
S. Rigby,
R. Schilling,
B. Sorazu,
A. Spencer,
S. Steinlechner,
K. A. Strain,
S. Hild
Abstract:
The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of develo…
▽ More
The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of development are being pursued to reach this goal, focusing both on modifications of the well-established Michelson detector configuration and development of different detector topologies. In this paper, we present the design of the world's first Sagnac speed meter interferometer which is currently being constructed at the University of Glasgow. With this proof-of-principle experiment we aim to demonstrate the theoretically predicted lower quantum noise in a Sagnac interferometer compared to an equivalent Michelson interferometer, to qualify Sagnac speed meters for further research towards an implementation in a future generation large scale gravitational wave detector, such as the planned Einstein Telescope observatory.
△ Less
Submitted 11 September, 2014; v1 submitted 12 May, 2014;
originally announced May 2014.
-
Length sensing and control of a Michelson interferometer with Power Recycling and Twin Signal Recycling cavities
Authors:
Christian Gräf,
André Thüring,
Henning Vahlbruch,
Karsten Danzmann,
Roman Schnabel
Abstract:
The techniques of power recycling and signal recycling have proven as key concepts to increase the sensitivity of large-scale gravitational wave detectors by independent resonant enhancement of light power and signal sidebands within the interferometer. Develo** the latter concept further, twin signal recycling was proposed as an alternative to conventional detuned signal recycling. Twin signal…
▽ More
The techniques of power recycling and signal recycling have proven as key concepts to increase the sensitivity of large-scale gravitational wave detectors by independent resonant enhancement of light power and signal sidebands within the interferometer. Develo** the latter concept further, twin signal recycling was proposed as an alternative to conventional detuned signal recycling. Twin signal recycling features the narrow-band sensitivity gain of conventional detuned signal recycling but furthermore facilitates the injection of squeezed states of light, increases the detector sensitivity over a wide frequency band and requires a less complex detection scheme for optimal signal readout. These benefits come at the expense of an additional recycling mirror, thus increasing the number of degrees of freedom in the interferometer which need to be controlled.
In this article we describe the development of a length sensing and control scheme and its successful application to a tabletop-scale power recycled Michelson interferometer with twin signal recycling. We were able to lock the interferometer in all relevant longitudinal degrees of freedom, enabling the long-term stable operation of the experiment. We thus laid the foundation for further investigations of this interferometer topology to evaluate its viability for the application in gravitational wave detectors.
△ Less
Submitted 29 November, 2012;
originally announced November 2012.
-
Optical layout for a 10m Fabry-Pérot Michelson interferometer with tunable stability
Authors:
Christian Gräf,
Stefan Hild,
Harald Lück,
Benno Willke,
Kenneth A. Strain,
Stefan Goßler,
Karsten Danzmann
Abstract:
The sensitivity of high-precision interferometric measurements can be limited by Brownian noise within dielectric mirror coatings. This occurs, for instance, in the optical resonators of gravitational wave detectors where the noise can be reduced by increasing the laser beam size. However, the stability of the resonator and its optical performance often impose a limit on the maximally feasible bea…
▽ More
The sensitivity of high-precision interferometric measurements can be limited by Brownian noise within dielectric mirror coatings. This occurs, for instance, in the optical resonators of gravitational wave detectors where the noise can be reduced by increasing the laser beam size. However, the stability of the resonator and its optical performance often impose a limit on the maximally feasible beam size. In this article we describe the optical design of a 10\,m Fabry-Pérot Michelson interferometer with tunable stability. Our design will allow us to carry out initial commissioning with arm cavities of high stability, while afterwards the arm cavity length can be increased stepwise towards the final, marginally stable configuration. Requiring only minimal hardware changes, with respect to a comparable "static" layout, the proposed technique will not only enable us to explore the stability limits of an optical resonator with realistic mirrors exhibiting inevitable surface imperfections, but also the opportunity to measure coating Brownian noise at frequencies as low as a few hundred Hertz. A detailed optical design of the tunable interferometer is presented and requirements for the optical elements are derived from robustness evaluations.
△ Less
Submitted 8 December, 2011;
originally announced December 2011.
-
Status of the GEO 600 squeezed-light laser
Authors:
Alexander Khalaidovski,
Henning Vahlbruch,
Nico Lastzka,
Christian Graef,
Harald Lueck,
Karsten Danzmann,
Hartmut Grote,
Roman Schnabel
Abstract:
In the course of the high-frequency upgrade of GEO 600, its optical configuration was extended by a squeezed-light laser [1]. Recently, a non-classically enhanced measurement sensitivity of GEO 600 was reported [2]. In this paper, a characterization of the squeezed-light laser is presented. Thereupon, the status of the integration into GEO 600 is reviewed, focussing on the sources of optical loss…
▽ More
In the course of the high-frequency upgrade of GEO 600, its optical configuration was extended by a squeezed-light laser [1]. Recently, a non-classically enhanced measurement sensitivity of GEO 600 was reported [2]. In this paper, a characterization of the squeezed-light laser is presented. Thereupon, the status of the integration into GEO 600 is reviewed, focussing on the sources of optical loss limiting the shot noise reduction by squeezing at the moment. Finally, the possibilities for a future loss reduction are discussed.
△ Less
Submitted 1 December, 2011;
originally announced December 2011.
-
The 10m AEI prototype facility A brief overview
Authors:
Tobias Westphal,
Gerald Bergmann,
Alessandro Bertolini,
Michael Born,
Yanbei Chen,
Alan V Cumming,
Liam Cunningham,
Katrin Dahl,
Christian Graef,
Giles Hammond,
Gerhard Heinzel,
Stefan Hild,
Sabina Huttner,
Russel Jones,
Fumiko Kawazoe,
Sina Koehlenbeck,
Gerrit Kuehn,
Harald Lueck,
Kasem Mossavi,
Jan H Poeld,
Kentaro Somiya,
Marielle van Veggel,
Alexander Wanner,
Benno Willke,
Ken A Strain
, et al. (2 additional authors not shown)
Abstract:
The AEI 10 m prototype interferometer facility is currently being constructed at the Albert Einstein Institute in Hannover, Germany. It aims to perform experiments for future gravitational wave detectors using advanced techniques. Seismically isolated benches are planned to be interferometrically interconnected and stabilized, forming a low-noise testbed inside a 100 m^3 ultra-high vacuum system.…
▽ More
The AEI 10 m prototype interferometer facility is currently being constructed at the Albert Einstein Institute in Hannover, Germany. It aims to perform experiments for future gravitational wave detectors using advanced techniques. Seismically isolated benches are planned to be interferometrically interconnected and stabilized, forming a low-noise testbed inside a 100 m^3 ultra-high vacuum system. A well-stabilized high power laser will perform differential position readout of 100 g test masses in a 10 m suspended arm-cavity enhanced Michelson interferometer at the crossover of measurement (shot) noise and backaction (quantum radiation pressure) noise, the so-called Standard Quantum Limit (SQL). Such a sensitivity enables experiments in the highly topical field of macroscopic quantum mechanics. In this article we introduce the experimental facility and describe the methods employed, technical details of subsystems will be covered in future papers.
△ Less
Submitted 28 December, 2011; v1 submitted 30 November, 2011;
originally announced November 2011.