Characterization of the Clinically Approved MRI Tracer Resotran for Magnetic Particle Imaging in a Comparison Study
Authors:
Fabian Mohn,
Konrad Scheffler,
Justin Ackers,
Agnes Weimer,
Franz Wegner,
Florian Thieben,
Mandy Ahlborg,
Patrick Vogel,
Matthias Graeser,
Tobias Knopp
Abstract:
Objective. The availability of magnetic nanoparticles with medical approval for human intervention is fundamental to the clinical translation of magnetic particle imaging (MPI). In this work, we thoroughly evaluate and compare the magnetic properties of an magnetic resonance imaging (MRI) approved tracer to validate its performance for MPI in future human trials. Approach. We analyze whether the r…
▽ More
Objective. The availability of magnetic nanoparticles with medical approval for human intervention is fundamental to the clinical translation of magnetic particle imaging (MPI). In this work, we thoroughly evaluate and compare the magnetic properties of an magnetic resonance imaging (MRI) approved tracer to validate its performance for MPI in future human trials. Approach. We analyze whether the recently approved MRI tracer Resotran is suitable for MPI. In addition, we compare Resotran with the previously approved and extensively studied tracer Resovist, with Ferrotran, which is currently in a clinical phase III study, and with the tailored MPI tracer Perimag. Main results. Initial magnetic particle spectroscopy measurements indicate that Resotran exhibits performance characteristics akin to Resovist, but below Perimag. We provide data on four different tracers using dynamic light scattering, transmission electron microscopy, vibrating sample magnetometry measurements, magnetic particle spectroscopy to derive hysteresis, point spread functions, and a serial dilution, as well as system matrix based MPI measurements on a preclinical scanner (Bruker 25/20 FF), including reconstructed images. Significance. Numerous approved magnetic nanoparticles used as tracers in MRI lack the necessary magnetic properties essential for robust signal generation in MPI. The process of obtaining medical approval for dedicated MPI tracers optimized for signal performance is an arduous and costly endeavor, often only justifiable for companies with a well-defined clinical business case. Resotran is an approved tracer that has become available in Europe for MRI. In this work, we study the eligibility of Resotran for MPI in an effort to pave the way for human MPI trials.
△ Less
Submitted 9 February, 2024;
originally announced February 2024.
-
Resonant Inductive Coupling Network for Human-Sized Magnetic Particle Imaging
Authors:
Fabian Mohn,
Fynn Förger,
Florian Thieben,
Martin Möddel,
Ingo Schmale,
Tobias Knopp,
Matthias Graeser
Abstract:
In Magnetic Particle Imaging, a field-free region is maneuvered throughout the field of view using a time-varying magnetic field known as the drive-field. Human-sized systems operate the drive-field in the kHz range and generate it by utilizing strong currents that can rise to the kA range within a coil called the drive field generator. Matching and tuning between a power amplifier, a band-pass fi…
▽ More
In Magnetic Particle Imaging, a field-free region is maneuvered throughout the field of view using a time-varying magnetic field known as the drive-field. Human-sized systems operate the drive-field in the kHz range and generate it by utilizing strong currents that can rise to the kA range within a coil called the drive field generator. Matching and tuning between a power amplifier, a band-pass filter and the drive-field generator is required. Here, for reasons of safety in future human scanners, a symmetrical topology and a transformer, called inductive coupling network is used. Our primary objectives are to achieve floating potentials to ensure patient safety, attaining high linearity and high gain for the resonant transformer. We present a novel systematic approach to the design of a loss-optimized resonant toroid with a D-shaped cross section, employing segmentation to adjust the inductance-to-resistance ratio while maintaining a constant quality factor. Simultaneously, we derive a specific matching condition of a symmetric transmit-receive circuit for magnetic particle imaging. The chosen setup filters the fundamental frequency and allows simultaneous signal transmission and reception. In addition, the decoupling of multiple drive field channels is discussed and the primary side of the transformer is evaluated for maximum coupling and minimum stray field. Two prototypes were constructed, measured, decoupled, and compared to the derived theory and to method-of-moment based simulations.
△ Less
Submitted 18 March, 2024; v1 submitted 23 December, 2023;
originally announced December 2023.
-
System Characterization of a Human-Sized 3D Real-Time Magnetic Particle Imaging Scanner for Cerebral Applications
Authors:
Florian Thieben,
Fynn Foerger,
Fabian Mohn,
Niklas Hackelberg,
Marija Boberg,
Jan-Philipp Scheel,
Martin Möddel,
Matthias Graeser,
Tobias Knopp
Abstract:
Since the initial patent in 2001, the Magnetic Particle Imaging (MPI) community has been striving to develop an MPI scanner suitable for human applications. Numerous contributions from different research fields, regarding tracer development, reconstruction methods, hardware engineering, and sequence design have been employed in pursuit of this objective. In this work, we introduce and thoroughly c…
▽ More
Since the initial patent in 2001, the Magnetic Particle Imaging (MPI) community has been striving to develop an MPI scanner suitable for human applications. Numerous contributions from different research fields, regarding tracer development, reconstruction methods, hardware engineering, and sequence design have been employed in pursuit of this objective. In this work, we introduce and thoroughly characterize an improved head-sized MPI scanner with an emphasis on human safety. The scanner is operated by open-source software that enables scanning, monitoring, analysis, and reconstruction, designed to be handled by end users. Our primary focus is to present all technical components of the scanner, with the ultimate objective to investigate brain perfusion imaging in phantom experiments. We have successfully achieved full 3D single- and multi-contrast imaging capabilities at a frame rate of 4 Hz with sufficient sensitivity and resolution for brain applications. To assess system characterization, we devised sensitivity, resolution, perfusion, and multi-contrast experiments, as well as field measurements and sequence analysis. The acquired images were captured using a clinically approved tracer and suitable magnetic field strengths, while adhering to the established human peripheral nerve stimulation thresholds. This advanced scanner holds potential as a tomographic imager for diagnosing conditions such as ischemic stroke or intracranial hemorrhage in environments lacking electromagnetic shielding. Furthermore, due to its low power consumption it may have the potential to facilitate long-term monitoring within intensive care units for various applications.
△ Less
Submitted 23 October, 2023;
originally announced October 2023.
-
Integrable Magnetic Fluid Hyperthermia Systems for 3D Magnetic Particle Imaging
Authors:
André Behrends,
Huimin Wei,
Alexander Neumann,
Thomas Friedrich,
Anna C. Bakenecker,
Matthias Graeser,
Thorsten M. Buzug
Abstract:
Background: Combining magnetic particle imaging (MPI) and magnetic fluid hyperthermia (MFH) offers the ability to perform localized hyperthermia and magnetic particle imaging-assisted ther-mometry of hyperthermia treatment. This allows precise regional selective heating inside the body without invasive interventions. In current MPI-MFH platforms, separate systems are used, which require object tra…
▽ More
Background: Combining magnetic particle imaging (MPI) and magnetic fluid hyperthermia (MFH) offers the ability to perform localized hyperthermia and magnetic particle imaging-assisted ther-mometry of hyperthermia treatment. This allows precise regional selective heating inside the body without invasive interventions. In current MPI-MFH platforms, separate systems are used, which require object transfer from one system to another. Here, we present the design, development and evaluation process for integrable MFH platforms, which extends a commercial MPI scanner with the functionality of MFH. Methods: The biggest issue of integrating magnetic fluid hyperthermia platforms into a magnetic par-ticle imaging system is the magnetic coupling of the devices, which induces high voltage in the imaging system, and is harming its components. In this paper we use a self-compensation approach derived from heuristic algorithms to protect the magnetic particle imaging scanner. The integrable platforms are evaluated regarding electrical and magnetic characteristics, cooling capability, field strength, the magnetic coupling to a replica of the magnetic particle imaging system's main solenoid and particle heating. Results: The MFH platforms generate suitable magnetic fields for magnetic heating of particles and are compatible with a commercial magnetic particle imaging scanner. In combination with the imaging system, selective heating with a gradient field and steerable heating positioning using the MPI focus fields are possible. Conclusion: The proposed MFH platforms serve as a therapeutic tool to unlock MFH functionality of a commercial magnetic particle imaging scanner, enabling its use in future preclinical trials of MPI-guided, spatially selective magnetic hyperthermia therapy.
△ Less
Submitted 21 September, 2023;
originally announced September 2023.
-
In situ theranostic platform uniting highly localized magnetic fluid hyperthermia, magnetic particle imaging, and thermometry in 3D
Authors:
Oliver Buchholz,
Kulthisa Sajjamark,
Jochen Franke,
Huimin Wei,
André Behrends,
Christian Münkel,
Cordula Grüttner,
Pierre Levan,
Dominik von Elverfeldt,
Matthias Gräser,
Thorsten Buzug,
Sébastien Bär,
Ulrich G. Hofmann
Abstract:
In all of medical profession a broad field of research is dedicated to seek less invasive and low-risk forms of therapy with the ultimate goal of non-invasive therapy, particularly in neoplasmic diseases. Theranostic platforms, combining diagnostic and therapeutic approaches within one system, have thus garnered interest to augment invasive surgical, chemical, and ionizing interventions. Magnetic…
▽ More
In all of medical profession a broad field of research is dedicated to seek less invasive and low-risk forms of therapy with the ultimate goal of non-invasive therapy, particularly in neoplasmic diseases. Theranostic platforms, combining diagnostic and therapeutic approaches within one system, have thus garnered interest to augment invasive surgical, chemical, and ionizing interventions. Magnetic particle imaging (MPI) offers, with its versatile tracer material (superparamagnetic iron oxide nanoparticles, SPIOs), a quite recent alternative to established radiation based diagnostic modalities. In addition, MPI lends a bimodal theranostic frame allowing to combine tomographic imaging with therapy techniques using the very same SPIOs. In this work, we show for the first time the interleaved combination of MPI-based imaging, therapy (highly localized magnetic fluid hyperthermia) and therapy safety control (MPI-based thermometry) within one theranostic platform in all three spatial dimensions.
△ Less
Submitted 17 April, 2023; v1 submitted 13 April, 2023;
originally announced April 2023.
-
Saline bolus for negative contrast perfusion imaging in magnetic particle imaging
Authors:
Fabian Mohn,
Miriam Exner,
Patryk Szwargulski,
Martin Möddel,
Tobias Knopp,
Matthias Graeser
Abstract:
Objective. Magnetic Particle Imaging (MPI) is capable of high temporal resolution measurements of the spatial distribution of magnetic nanoparticles and therefore well suited for perfusion imaging, which is an important tool in medical diagnosis. Perfusion imaging in MPI usually requires a fresh bolus of tracer material to capture the key signal dynamics. Here, we propose a method to decouple the…
▽ More
Objective. Magnetic Particle Imaging (MPI) is capable of high temporal resolution measurements of the spatial distribution of magnetic nanoparticles and therefore well suited for perfusion imaging, which is an important tool in medical diagnosis. Perfusion imaging in MPI usually requires a fresh bolus of tracer material to capture the key signal dynamics. Here, we propose a method to decouple the imaging sequence from the injection of additional tracer material, without further increasing the administered iron dose in the body with each image. Approach. A bolus of physiological saline solution without any particles (negative contrast) diminishes the steady-state concentration of a long-circulating tracer during passage. This depression in the measured concentration contributes to the required contrast dynamics. The presence of a long-circulating tracer is therefore a prerequisite to obtain the negative contrast. As a quantitative tracer based imaging method, the signal is linear in the tracer concentration for any location that contains nanoparticles and zero in the surrounding tissue which does not provide any intrinsic signal. After tracer injection, the concentration over time (positive contrast) can be utilized to calculate dynamic diagnostic parameters like perfusion parameters in vessels and organs. Every acquired perfusion image thus requires a new bolus of tracer with a sufficiently large iron dose to be visible above the background. Main results. Perfusion parameters are calculated based on the time response of the proposed negative bolus and compared to a positive bolus. Results from phantom experiments show that normalized signals from positive and negative boli are concurrent and deviations of calculated perfusion maps are low. Significance. Our method opens up the possibility to increase the total monitoring time, while minimizing the iron dose per acquired image.
△ Less
Submitted 9 August, 2023; v1 submitted 9 March, 2023;
originally announced March 2023.
-
System Matrix based Reconstruction for Pulsed Sequences in Magnetic Particle Imaging
Authors:
Fabian Mohn,
Tobias Knopp,
Marija Boberg,
Florian Thieben,
Patryk Szwargulski,
Matthias Graeser
Abstract:
Improving resolution and sensitivity will widen possible medical applications of magnetic particle imaging. Pulsed excitation promises such benefits, at the cost of more complex hardware solutions and restrictions on drive field amplitude and frequency. State-of-the-art systems utilize a sinusoidal excitation to drive superparamagnetic nanoparticles into the non-linear part of their magnetization…
▽ More
Improving resolution and sensitivity will widen possible medical applications of magnetic particle imaging. Pulsed excitation promises such benefits, at the cost of more complex hardware solutions and restrictions on drive field amplitude and frequency. State-of-the-art systems utilize a sinusoidal excitation to drive superparamagnetic nanoparticles into the non-linear part of their magnetization curve, which creates a spectrum with a clear separation of direct feed-through and higher harmonics caused by the particles response. One challenge for rectangular excitation is the discrimination of particle and excitation signals, both broad-band. Another is the drive-field sequence itself, as particles that are not placed at the same spatial position, may react simultaneously and are not separable by their signal phase or shape. To overcome this potential loss of information in spatial encoding for high amplitudes, a superposition of shifting fields and drive-field rotations is proposed in this work. Upon close view, a system matrix approach is capable to maintain resolution, independent of the sequence, if the response to pulsed sequences still encodes information within the phase. Data from an Arbitrary Waveform Magnetic Particle Spectrometer with offsets in two spatial dimensions is measured and calibrated to guarantee device independence. Multiple sequence types and waveforms are compared, based on frequency space image reconstruction from emulated signals, that are derived from measured particle responses. A resolution of 1.0 mT (0.8 mm for a gradient of (-1.25,\,-1.25,\,2.5) T/m) in x- and y-direction was achieved and a superior sensitivity for pulsed sequences was detected on the basis of reference phantoms.
△ Less
Submitted 28 January, 2022; v1 submitted 23 August, 2021;
originally announced August 2021.
-
Efficient Joint Estimation of Tracer Distribution and Background Signals in Magnetic Particle Imaging using a Dictionary Approach
Authors:
Tobias Knopp,
Mirco Grosser,
Matthias Graeser,
Timo Gerkmann,
Martin Möddel
Abstract:
Background signals are a primary source of artifacts in magnetic particle imaging and limit the sensitivity of the method since background signals are often not precisely known and vary over time. The state-of-the art method for handling background signals uses one or several background calibration measurements with an empty scanner bore and subtracts a linear combination of these background measu…
▽ More
Background signals are a primary source of artifacts in magnetic particle imaging and limit the sensitivity of the method since background signals are often not precisely known and vary over time. The state-of-the art method for handling background signals uses one or several background calibration measurements with an empty scanner bore and subtracts a linear combination of these background measurements from the actual particle measurement. This approach yields satisfying results in case that the background measurements are taken in close proximity to the particle measurement and when the background signal drifts linearly. In this work, we propose a joint estimation of particle distribution and background signal based on a dictionary that is capable of representing typical background signals and allows for precise estimation of the background even when the latter is drifting non-linearly over time. Using a singular-value decomposition, the dictionary is derived from a large number of background calibration scans that do not need to be recorded in close proximity to the particle measurement. The dictionary is sufficiently expressive and represented by its principle components. The proposed joint estimation of particle distribution and background signal is expressed as a linear Tikhonov-regularized least squares problem, which can be efficiently solved. In phantom experiments it is shown that the method strongly suppresses background artifacts and even allows to estimate and remove the direct feed-through of the excitation field.
△ Less
Submitted 17 June, 2021; v1 submitted 10 June, 2020;
originally announced June 2020.
-
Design of a Head Coil for High Resolution Mouse Brain Perfusion Imaging using Magnetic Particle Imaging
Authors:
Matthias Graeser,
Peter Ludewig,
Patryk Szwargulski,
Fynn Foerger,
Tom Liebing,
Nils D. Forkert,
Florian Thieben,
Tim Magnus,
Tobias Knopp
Abstract:
Magnetic Particle Imaging (MPI) is a novel and versatile imaging modality develo** towards human application. When up-scaling to human size, the sensitivity of the systems naturally drops as the coil sensitivity depends on the bore diameter. Thus, new methods to push the sensitivity limit further have to be investigated to cope for this loss. In this paper a dedicated surface coil for mice is de…
▽ More
Magnetic Particle Imaging (MPI) is a novel and versatile imaging modality develo** towards human application. When up-scaling to human size, the sensitivity of the systems naturally drops as the coil sensitivity depends on the bore diameter. Thus, new methods to push the sensitivity limit further have to be investigated to cope for this loss. In this paper a dedicated surface coil for mice is developed, improving the sensitivity in cerebral imaging applications. Similar to MRI the developed surface coil improves the sensitivity due to the closer vicinity to the region of interest. With the developed surface coil presented in this work, it is possible to image tracer samples containing only 896 pg Fe and detect even small vessels and anatomical structures within a wild type mouse model. As current sensitivity measures require a tracer system a new method for determining a sensitivity measure without this requirement is presented and verified to enable comparison between MPI receiver systems.
△ Less
Submitted 25 May, 2022; v1 submitted 24 April, 2020;
originally announced April 2020.
-
In-Vitro MPI-Guided IVOCT Catheter Tracking in Real Time for Motion Artifact Compensation
Authors:
Florian Griese,
Sarah Latus,
Matthias Schlüter,
Matthias Graeser,
Matthias Lutz,
Alexander Schlaefer,
Tobias Knopp
Abstract:
Purpose: Using 4D magnetic particle imaging (MPI), intravascular optical coherence tomography (IVOCT) catheters are tracked in real time in order to compensate for image artifacts related to relative motion. Our approach demonstrates the feasibility for bimodal IVOCT and MPI in-vitro experiments. Material and Methods: During IVOCT imaging of a stenosis phantom the catheter is tracked using MPI. A…
▽ More
Purpose: Using 4D magnetic particle imaging (MPI), intravascular optical coherence tomography (IVOCT) catheters are tracked in real time in order to compensate for image artifacts related to relative motion. Our approach demonstrates the feasibility for bimodal IVOCT and MPI in-vitro experiments. Material and Methods: During IVOCT imaging of a stenosis phantom the catheter is tracked using MPI. A 4D trajectory of the catheter tip is determined from the MPI data using center of mass sub-voxel strategies. A custom built IVOCT imaging adapter is used to perform different catheter motion profiles: no motion artifacts, motion artifacts due to catheter bending, and heart beat motion artifacts. Two IVOCT volume reconstruction methods are compared qualitatively and quantitatively using the DICE metric and the known stenosis length. Results: The MPI-tracked trajectory of the IVOCT catheter is validated in multiple repeated measurements calculating the absolute mean error and standard deviation. Both volume reconstruction methods are compared and analyzed whether they are capable of compensating the motion artifacts. The novel approach of MPI-guided catheter tracking corrects motion artifacts leading to a DICE coefficient with a minimum of 86% in comparison to 58% for a standard reconstruction approach. Conclusions: IVOCT catheter tracking with MPI in real time is an auspicious method for radiation free MPI-guided IVOCT interventions. The combination of MPI and IVOCT can help to reduce motion artifacts due to catheter bending and heart beat for optimized IVOCT volume reconstructions.
△ Less
Submitted 27 November, 2019;
originally announced November 2019.
-
Bimodal intravascular volumetric imaging combining OCT and MPI
Authors:
Sarah Latus,
Florian Griese,
Matthias Schlüter,
Christoph Otte,
Martin Möddel,
Matthias Graeser,
Thore Saathoff,
Tobias Knopp,
Alexander Schlaefer
Abstract:
Intravascular optical coherence tomography (IVOCT) is a catheter based image modality allowing for high resolution imaging of vessels. It is based on a fast sequential acquisition of A-scans with an axial spatial resolution in the range of 5 to 10 μm, i.e., one order of magnitude higher than in conventional methods like intravascular ultrasound or computed tomography angiography. However, position…
▽ More
Intravascular optical coherence tomography (IVOCT) is a catheter based image modality allowing for high resolution imaging of vessels. It is based on a fast sequential acquisition of A-scans with an axial spatial resolution in the range of 5 to 10 μm, i.e., one order of magnitude higher than in conventional methods like intravascular ultrasound or computed tomography angiography. However, position and orientation of the catheter in patient coordinates cannot be obtained from the IVOCT measurements alone. Hence, the pose of the catheter needs to be established to correctly reconstruct the three-dimensional vessel shape. Magnetic particle imaging (MPI) is a three-dimensional tomographic, tracer-based and radiation-free image modality providing high temporal resolution with unlimited penetration depth. Volumetric MPI images are angiographic and hence suitable to complement IVOCT as a co-modality. We study simultaneous bimodal IVOCT MPI imaging with the goal of estimating the IVOCT pullback path based on the 3D MPI data. We present a setup to study and evaluate simultaneous IVOCT and MPI image acquisition of differently shaped vessel phantoms. First, the infuence of the MPI tracer concentration on the optical properties required for IVOCT is analyzed. Second, using a concentration allowing for simultaneous imaging, IVOCT and MPI image data is acquired sequentially and simultaneously. Third, the luminal centerline is established from the MPI image volumes and used to estimate the catheter pullback trajectory for IVOCT image reconstruction. The image volumes are compared to the known shape of the phantoms. We were able to identify a suitable MPI tracer concentration of 2.5 mmol/L with negligible influence on the IVOCT signal. The pullback trajectory estimated from MPI agrees well with the centerline of the phantoms. (...)
△ Less
Submitted 21 November, 2019;
originally announced November 2019.
-
Moving Table Magnetic Particle Imaging: A stepwise approach preserving high spatio-temporal resolution
Authors:
Patryk Szwargulski,
Nadine Gdaniec,
Matthias Graeser,
Martin Möddel,
Florian Griese,
Kannan M. Krishnan,
Thorsten M. Buzug,
Tobias Knopp
Abstract:
Magnetic Particle Imaging (MPI) is a highly sensitive imaging method that enables the visualization of magnetic tracer materials with a temporal resolution of more than 46 volumes per second. In MPI the size of the field of view scales with the strengths of the applied magnetic fields. In clinical applications those strengths are limited by peripheral nerve stimulation, specific absorption rates,…
▽ More
Magnetic Particle Imaging (MPI) is a highly sensitive imaging method that enables the visualization of magnetic tracer materials with a temporal resolution of more than 46 volumes per second. In MPI the size of the field of view scales with the strengths of the applied magnetic fields. In clinical applications those strengths are limited by peripheral nerve stimulation, specific absorption rates, and the requirement to acquire images of high spatial resolution. Therefore, the size of the field of view is usually a few cubic centimeters. To bypass this limitation, additional focus fields and/or external object movements can be applied. In this work, the latter approach is investigated. An object is moved through the scanner bore one step at a time, while the MPI scanner continuously acquires data from its static field of view. Using a 3D phantom and dynamic 3D in vivo data it is shown that the data from such a moving table experiment can be jointly reconstructed after reordering the data with respect to the stepwise object shifts and heart beat phases.
△ Less
Submitted 10 December, 2018;
originally announced December 2018.
-
Human-sized Magnetic Particle Imaging for Brain Applications
Authors:
M. Gräser,
F. Thieben,
P. Szwargulski,
F. Werner,
N. Gdaniec,
M. Boberg,
F. Griese,
M. Möddel,
P. Ludewig,
D. van de Ven,
O. M. Weber,
O. Woywode,
B. Gleich,
T. Knopp
Abstract:
Determining the brain perfusion is an important task for the diagnosis and treatment of vascular diseases such as occlusions and intracerebral haemorrhage. Even after successful diagnosis and treatment, there is a high risk of restenosis or rebleeding such that patients need intense and frequent attention in the days after treatment. Within this work, we will present a diagnostic tomographic image…
▽ More
Determining the brain perfusion is an important task for the diagnosis and treatment of vascular diseases such as occlusions and intracerebral haemorrhage. Even after successful diagnosis and treatment, there is a high risk of restenosis or rebleeding such that patients need intense and frequent attention in the days after treatment. Within this work, we will present a diagnostic tomographic imager that allows access to brain perfusion information quantitatively in short intervals. The imager is the first functional magnetic particle imaging device for brain imaging on a human-scale. It is highly sensitive and allows the detection of an iron concentration of 14.7 ng /ml (263 pmol\ml), which is the lowest iron concentration imaged by MPI so far. The imager is self-shielded and can be used in unshielded environments such as intensive care units. In combination with the low technical requirements this opens up a whole variety of possible medical applications and would allow monitoring possibilities on the stroke and intensive care units.
△ Less
Submitted 18 October, 2018;
originally announced October 2018.
-
Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil
Authors:
Matthias Gräser,
Tobias Knopp,
Patryk Szwargulski,
Thomas Friedrich,
Anselm von Gladiss,
Michael Kaul,
Kannan M Krishnan,
Harald Ittrich,
Gerhard Adam,
Thorsten M. Buzug
Abstract:
Superparamagnetic iron-oxide nanoparticles can be used in a variety of medical applications like vascular or targeted imaging. Magnetic particle imaging (MPI) is a promising tomographic imaging technique that allows visualizing the 3D nanoparticle distribution concentration in a non-invasive manner. The two main strengths of MPI are high temporal resolution and high sensitivity. While the first ha…
▽ More
Superparamagnetic iron-oxide nanoparticles can be used in a variety of medical applications like vascular or targeted imaging. Magnetic particle imaging (MPI) is a promising tomographic imaging technique that allows visualizing the 3D nanoparticle distribution concentration in a non-invasive manner. The two main strengths of MPI are high temporal resolution and high sensitivity. While the first has been proven in the assessment of dynamic processes like cardiac imaging, it is unknown how far the detection limit of MPI can be lowered. Within this work, we will present a highly sensitive gradiometric receive-coil unit combined with a noise-matching network tailored for the measurement of mice. The setup is capable of detecting 5 ng of iron in vitro at 2.14 sec acquisition time. In terms of iron concentration we are able to detect 156 μg/L marking the lowest value that has been reported for an MPI scanner so far. In vivo MPI mouse images of a 512 ng bolus at 21.5 ms acquisition time allow for capturing the flow of an intravenously injected tracer through the heart of a mouse. Since it has been rather difficult to compare detection limits across MPI publications we propose guidelines improving the comparability of future MPI studies.
△ Less
Submitted 5 May, 2017; v1 submitted 6 April, 2017;
originally announced April 2017.