TEMPUS, a Timepix4-based system for event-based X-rays detection
Authors:
Jonathan Correa,
Alexandr Ignatenko,
David Pennicard,
Sabine Lange,
Sergei Fridman,
Sebastian Karl,
Leon Lohse,
Bjoern Senfftleen,
Ilya Sergeev,
Sven Velten,
Deepak Prajapat,
Lars Bocklage,
Hubertus Bromberger,
Andrey Samartsev,
Aleksandr Chumakov,
Rudolf Rueffer,
Joachim von Zanthier,
Ralf Roehlsberger,
Heinz Graafsma
Abstract:
A readout system based on the Timepix4 ASIC, is being developed for photon science. The TEMPUS detector can be operated in two distinct modes: a photon counting mode, which allows for conventional full-frame readout at rates up to 40 kfps; and an event-driven time-stam** mode, which allows excellent time resolution in the nanosecond regime in measurements with moderate X-ray flux. In this paper,…
▽ More
A readout system based on the Timepix4 ASIC, is being developed for photon science. The TEMPUS detector can be operated in two distinct modes: a photon counting mode, which allows for conventional full-frame readout at rates up to 40 kfps; and an event-driven time-stam** mode, which allows excellent time resolution in the nanosecond regime in measurements with moderate X-ray flux. In this paper, we introduce the initial prototype, a single-chip system, and present the first results obtained at PETRA III and ESRF.
△ Less
Submitted 10 April, 2024;
originally announced April 2024.
-
Megapixels @ Megahertz -- The AGIPD High-Speed Cameras for the European XFEL
Authors:
Ulrich Trunk,
Aschkan Allahgholi,
Julian Becker,
Annette Delfs,
Roberto Dinapoli,
Peter Göttlicher,
Heinz Graafsma,
Dominic Greiffenberg,
Helmut Hirsemann,
Stefanie Jack,
Alexander Klyuev,
Hans Krüger,
Manuela Kuhn,
Torsten Laurus,
Alessandro Marras,
Davide Mezza,
Aldo Mozzanica,
Jennifer Poehlsen,
Ofir Shefer Shalev,
Igor Sheviakov,
Bernd Schmitt,
Jörn Schwandt,
Xintian Shi,
Sergej Smoljanin,
Jiaguo Zhang
, et al. (1 additional authors not shown)
Abstract:
The European XFEL is an extremely brilliant Free Electron Laser Source with a very demanding pulse structure: trains of 2700 X-Ray pulses are repeated at 10 Hz. The pulses inside the train are spaced by 220 ns and each one contains up to $10^{12}$ photons of 12.4 keV, while being $\le 100$ fs in length. AGIPD, the Adaptive Gain Integrating Pixel Detector, is a hybrid pixel detector developed by DE…
▽ More
The European XFEL is an extremely brilliant Free Electron Laser Source with a very demanding pulse structure: trains of 2700 X-Ray pulses are repeated at 10 Hz. The pulses inside the train are spaced by 220 ns and each one contains up to $10^{12}$ photons of 12.4 keV, while being $\le 100$ fs in length. AGIPD, the Adaptive Gain Integrating Pixel Detector, is a hybrid pixel detector developed by DESY, PSI, and the Universities of Bonn and Hamburg to cope with these properties. It is a fast, low noise integrating detector, with single photon sensitivity (for $\text{E}_γ \ge 6$ keV) and a large dynamic range, up to $10^4$ photons at 12.4 keV. This is achieved with a charge sensitive amplifier with 3 adaptively selected gains per pixel. 352 images can be recorded at up to 6.5 MHz and stored in the in-pixel analogue memory and read out between pulse trains. The core component of this detector is the AGIPD ASIC, which consists of $64 \times 64$ pixels of $200 μ\text{m} \times 200 μ\text{m}$. Control of the ASIC's image acquisition and analogue readout is via a command based interface. FPGA based electronic boards, controlling ASIC operation, image digitisation and 10 GE data transmission interface AGIPD detectors to DAQ and control systems. An AGIPD 1 Mpixel detector has been installed at the SPB experimental station in August 2017, while a second one is currently commissioned for the MID endstation. A larger (4 Mpixel) AGIPD detector and one to employ Hi-Z sensor material to efficiently register photons up to $\text{E}_γ \approx 25$ keV are currently under construction.
△ Less
Submitted 6 August, 2019;
originally announced August 2019.
-
First demonstration of 3D optical readout of a TPC using a single photon sensitive Timepix3 based camera
Authors:
A. Roberts,
P. Svihra,
A. Al-Refaie,
H. Graafsma,
J. Küpper,
K. Majumdar,
K. Mavrokoridis,
A. Nomerotski,
D. Pennicard,
B. Philippou,
S. Trippel,
C. Touramanis,
J. Vann
Abstract:
The ARIADNE project is develo** innovative optical readout technologies for two-phase liquid Argon time projection chambers (LArTPCs). Optical readout presents an exciting alternative to the current paradigm of charge readout. Optical readout is simple, scalable and cost effective. This paper presents first demonstration of 3D optical readout of TPC, using CF4 gas as a proof of principle. Both c…
▽ More
The ARIADNE project is develo** innovative optical readout technologies for two-phase liquid Argon time projection chambers (LArTPCs). Optical readout presents an exciting alternative to the current paradigm of charge readout. Optical readout is simple, scalable and cost effective. This paper presents first demonstration of 3D optical readout of TPC, using CF4 gas as a proof of principle. Both cosmic rays and an Americium-241 alpha source have been imaged in 100 mbar CF4. A single-photon sensitive camera was developed by combining a Timepix3 (TPX3) based camera with an image intensifier. When a pixel of TPX3 is hit, a packet containing all information about the hit is produced. This packet contains the x,y coordinates of the pixel, time of arrival (ToA) and time over threshold (ToT) information. The z position of the hit in the TPC is determined by combining drift velocity with ToA information. 3D event reconstruction is performed by combining the pixels x,y location with this calculated z position. Calorimetry is performed using time over threshold, a measure of the intensity of the hit.
△ Less
Submitted 25 May, 2019; v1 submitted 23 October, 2018;
originally announced October 2018.
-
The Adaptive Gain Integrating Pixel Detector at the European XFEL
Authors:
Aschkan Allahgholi,
Julian Becker,
Annette Delfs,
Roberto Dinapoli,
Peter Goettlicher,
Dominic Greiffenberg,
Beat Henrich,
Helmut Hirsemann,
Manuela Kuhn,
Robert Klanner,
Alexander Klyuev,
Hans Krueger,
Sabine Lange,
Torsten Laurus,
Alessandro Marras,
Davide Mezza,
Aldo Mozzanica,
Magdalena Niemann,
Jennifer Poehlsen,
Joern Schwandt,
Igor Sheviakov,
Xintian Shi,
Sergej Smoljanin,
Lothar Steffen,
Jolanta Sztuk-Dambietz
, et al. (7 additional authors not shown)
Abstract:
The Adaptive Gain Integrating Pixel Detector (AGIPD) is an x-ray imager, custom designed for the European x-ray Free-Electron Laser (XFEL). It is a fast, low noise integrating detector, with an adaptive gain amplifier per pixel. This has an equivalent noise of less than 1 keV when detecting single photons and, when switched into another gain state, a dynamic range of more than 10$^4$ photons of 12…
▽ More
The Adaptive Gain Integrating Pixel Detector (AGIPD) is an x-ray imager, custom designed for the European x-ray Free-Electron Laser (XFEL). It is a fast, low noise integrating detector, with an adaptive gain amplifier per pixel. This has an equivalent noise of less than 1 keV when detecting single photons and, when switched into another gain state, a dynamic range of more than 10$^4$ photons of 12 keV. In burst mode the system is able to store 352 images while running at up to 6.5 MHz, which is compatible with the 4.5 MHz frame rate at the European XFEL. The AGIPD system was installed and commissioned in August 2017, and successfully used for the first experiments at the Single Particles, Clusters and Biomolecules (SPB) experimental station at the European XFEL since September 2017. This paper describes the principal components and performance parameters of the system.
△ Less
Submitted 2 October, 2018; v1 submitted 1 August, 2018;
originally announced August 2018.
-
Optimization of radiation hardness and charge collection of edgeless silicon pixel sensors for photon science
Authors:
Jiaguo Zhang,
Damaris Tartarotti Maimone,
David Pennicard,
Milija Sarajlic,
Heinz Graafsma
Abstract:
Recent progress in active-edge technology of silicon sensors enables the development of large-area tiled silicon pixel detectors with small dead space between modules by utilizing edgeless sensors. Such technology has been proven in successful productions of ATLAS and Medipix-based silicon pixel sensors by a few foundries. However, the drawbacks of edgeless sensors are poor radiation hardness for…
▽ More
Recent progress in active-edge technology of silicon sensors enables the development of large-area tiled silicon pixel detectors with small dead space between modules by utilizing edgeless sensors. Such technology has been proven in successful productions of ATLAS and Medipix-based silicon pixel sensors by a few foundries. However, the drawbacks of edgeless sensors are poor radiation hardness for ionizing radiation and non-uniform charge collection by edge pixels. In this work, the radiation hardness of edgeless sensors with different polarities has been investigated using Synopsys TCAD with X-ray radiation-damage parameters implemented. Results show that if no conventional guard ring is present, none of the current designs are able to achieve a high breakdown voltage (typically < 30 V) after irradiation to a dose of ~10 MGy. In addition, a charge-collection model has been developed and was used to calculate the charges collected by the edge pixels of edgeless sensors when illuminated with X-rays. The model takes into account the electric field distribution inside the pixel sensor, the absorption of X-rays, drift and diffusion of electrons and holes, charge sharing effect, and threshold settings in ASICs. It is found that the non-uniform charge collection of edge pixels is caused by the strong bending of electric field and the non-uniformity depends on bias voltage, sensor thickness and distance from active edge to the last pixel ("edge space"). In particular, the last few pixels close to the active edge of the sensor are not sensitive to low-energy X-rays (< 10 keV) especially for sensors with thicker Si and smaller edge space. The results from the model calculation have been compared to measurements and good agreement was obtained. The model has been used to optimize the edge design.
△ Less
Submitted 3 October, 2014;
originally announced October 2014.
-
Intensity interferometry of single x-ray pulses from a synchrotron storage ring
Authors:
A. Singer,
U. Lorenz,
A. Marras,
A. Klyuev,
J. Becker,
K. Schlage,
P. Skopintsev,
O. Gorobtsov,
A. Shabalin,
H. -C. Wille,
H. Franz,
H. Graafsma,
I. A. Vartanyants
Abstract:
We report on measurements of second-order intensity correlations at the high brilliance storage ring PETRA III using a prototype of the newly developed Adaptive Gain Integrating Pixel Detector (AGIPD). The detector recorded individual synchrotron radiation pulses with an x-ray photon energy of 14.4 keV and repetition rate of about 5 MHz. The second-order intensity correlation function was measured…
▽ More
We report on measurements of second-order intensity correlations at the high brilliance storage ring PETRA III using a prototype of the newly developed Adaptive Gain Integrating Pixel Detector (AGIPD). The detector recorded individual synchrotron radiation pulses with an x-ray photon energy of 14.4 keV and repetition rate of about 5 MHz. The second-order intensity correlation function was measured simultaneously at different spatial separations that allowed to determine the transverse coherence length at these x-ray energies. The measured values are in a good agreement with theoretical simulations based on the Gaussian Schell-model.
△ Less
Submitted 13 February, 2014;
originally announced February 2014.
-
Study of X-ray radiation damage in the AGIPD sensor for the European XFEL
Authors:
Jiaguo Zhang,
Eckhart Fretwurst,
Heinz Graafsma,
Robert Klanner,
Ioannis Kopsalis,
Joern Schwandt
Abstract:
The European X-ray Free Electron Laser (XFEL), currently being constructed in Hamburg and planning to be operational in 2017 for users, will deliver 27,000 fully coherent, high brilliance X-ray pulses per second with duration less than 100 fs. The unique features of the X-ray beam pose major challenges for detectors used at the European XFEL for imaging experiments, in particular a radiation toler…
▽ More
The European X-ray Free Electron Laser (XFEL), currently being constructed in Hamburg and planning to be operational in 2017 for users, will deliver 27,000 fully coherent, high brilliance X-ray pulses per second with duration less than 100 fs. The unique features of the X-ray beam pose major challenges for detectors used at the European XFEL for imaging experiments, in particular a radiation tolerance of silicon sensors for doses up to 1 GGy for 3 years of operation at an operating voltage above 500 V. One of the detectors under development at the European XFEL is the Adaptive Gain Integrating Pixel Detector (AGIPD), which is a hybrid detector system with ASICs bump-bonded to p+n silicon pixel sensors. We have designed the silicon sensors for the AGIPD, which have been fabricated by SINTEF and delivered in the beginning of February of 2013. To demonstrate the performance of the AGIPD sensor with regard to radiation hardness, mini-sensors with the same pixel and guard-ring designs as the AGIPD together with test structures have been irradiated at the beamline P11 of PETRA III with 8 keV and 12 keV monoenergetic X-rays to dose values up to 10 MGy. The radiation hardness of the AGIPD sensor has been proven and all electrical properties are within specification before and after irradiation. In addition, the oxide-charge density and surface-current density from test structures have been characterized as function of the X-ray dose and compared to previous measurements for test structures produced by four vendors.
△ Less
Submitted 13 December, 2013;
originally announced December 2013.
-
Challenges for the Adaptive Gain Integrating Pixel Detector (AGIPD) design due to the high intensity photon radiation environment at the European XFEL
Authors:
J. Becker,
L. Bianco,
P. Göttlicher,
H. Graafsma,
H. Hirsemann,
S. Jack,
A. Klyuev,
S. Lange A. Marras,
U. Trunk,
R. Klanner,
J. Schwandt,
J. Zhang,
R. Dinapoli,
D. Greiffenberg,
B. Henrich,
A. Mozzanica,
B. Schmitt,
X. Shi,
M. Gronewald,
H. Krüger
Abstract:
The European X-ray Free Electron Laser (XFEL) is a new research facility currently under construction in Hamburg, Germany. With a pulse length of less than 100 fs and an extremely high luminosity of 27000 flashes per second the European XFEL will have a unique time structure that demands the development of new detectors tailored to the requirements imposed by the experiments while complying with t…
▽ More
The European X-ray Free Electron Laser (XFEL) is a new research facility currently under construction in Hamburg, Germany. With a pulse length of less than 100 fs and an extremely high luminosity of 27000 flashes per second the European XFEL will have a unique time structure that demands the development of new detectors tailored to the requirements imposed by the experiments while complying with the machine specific operation parameters. The Adaptive Gain Integrating Pixel Detector (AGIPD) is one response to the need for large 2D detectors, able to cope with the 4.5 MHz frame rate, as well as with the high dynamic range needed by XFEL experiments ranging from single photons to more than 10$^4$ 12 keV photons per pixel per pulse. In addition it has to withstand doses of up to 1 GGy over three years.
△ Less
Submitted 11 March, 2013;
originally announced March 2013.
-
Performance tests of an AGIPD 0.4 assembly at the beamline P10 of PETRA III
Authors:
J. Becker,
A. Marras,
A. Klyuev,
F. Westermeier,
U. Trunk,
H. Graafsma
Abstract:
The Adaptive Gain Integrating Pixel Detector (AGIPD) is a novel detector system, currently under development by a collaboration of DESY, the Paul Scherrer Institute in Switzerland, the University of Hamburg and the University of Bonn, and is primarily designed for use at the European XFEL. To verify key features of this detector, an AGIPD 0.4 test chip assembly was tested at the P10 beamline of th…
▽ More
The Adaptive Gain Integrating Pixel Detector (AGIPD) is a novel detector system, currently under development by a collaboration of DESY, the Paul Scherrer Institute in Switzerland, the University of Hamburg and the University of Bonn, and is primarily designed for use at the European XFEL. To verify key features of this detector, an AGIPD 0.4 test chip assembly was tested at the P10 beamline of the PETRA III synchrotron at DESY. The test chip successfully imaged both the direct synchrotron beam and single 7.05 keV photons at the same time, demonstrating the large dynamic range required for XFEL experiments. X-ray scattering measurements from a test sample agree with standard measurements and show the chip's capability of observing dynamics at the microsecond time scale.
△ Less
Submitted 14 May, 2013; v1 submitted 11 March, 2013;
originally announced March 2013.
-
R&D Paths of Pixel Detectors for Vertex Tracking and Radiation Imaging
Authors:
M. Battaglia,
C. Da Via,
D. Bortoletto,
R. Brenner,
M. Campbell,
P. Collins,
G. F. Dalla Betta,
P. Denes,
H. Graafsma,
I. M. Gregor,
A. Kluge,
V. Manzari,
C. Parkes,
V. Re,
P. Riedler,
G. Rizzo,
W. Snoeys,
M. Winter
Abstract:
This report reviews current trends in the R&D of semiconductor pixellated sensors for vertex tracking and radiation imaging. It identifies requirements of future HEP experiments at colliders, needed technological breakthroughs and highlights the relation to radiation detection and imaging applications in other fields of science.
This report reviews current trends in the R&D of semiconductor pixellated sensors for vertex tracking and radiation imaging. It identifies requirements of future HEP experiments at colliders, needed technological breakthroughs and highlights the relation to radiation detection and imaging applications in other fields of science.
△ Less
Submitted 1 August, 2012;
originally announced August 2012.
-
The single photon sensitivity of the Adaptive Gain Integrating Pixel Detector
Authors:
Julian Becker,
Dominic Greiffenberg,
Ulrich Trunk,
Xintian Shi,
Roberto Dinapoli,
Aldo Mozzanica,
Beat Henrich,
Bernd Schmitt,
Heinz Graafsma
Abstract:
Single photon sensitivity is an important property of certain detection systems. This work investigated the single photon sensitivity of the Adaptive Gain Integrating Pixel Detector (AGIPD) and its dependence on possible detector noise values. Due to special requirements at the European X-ray Free Electron Laser (XFEL) the AGIPD finds the number of photons absorbed in each pixel by integrating the…
▽ More
Single photon sensitivity is an important property of certain detection systems. This work investigated the single photon sensitivity of the Adaptive Gain Integrating Pixel Detector (AGIPD) and its dependence on possible detector noise values. Due to special requirements at the European X-ray Free Electron Laser (XFEL) the AGIPD finds the number of photons absorbed in each pixel by integrating the total signal. Photon counting is done off line on a thresholded data set.
It was shown that AGIPD will be sensitive to single photons of 8 keV energy or more (detection efficiency $\gg$ 50%, less than 1 count due to noise per 10$^6$ pixels). Should the final noise be at the lower end of the possible range (200 - 400 electrons) single photon sensitivity can also be achieved at 5 keV beam energy.
It was shown that charge summing schemes are beneficial when the noise is sufficiently low. The total detection rate of events is increased and the probability to count a single event multiple times in adjacent pixels is reduced by a factor of up to 40.
The entry window of AGIPD allows 3 keV photons to reach the sensitive volume with approximately 70% probability. Therefore the low energy performance of AGIPD was explored, finding a maximum noise floor below 0.035 hits/pixel/frame at 3 keV beam energy. Depending on the noise level and selected threshold this value can be reduced by a factor of approximately 10. Even though single photon sensitivity, as defined in this work, is not given, imaging at this energy is still possible, allowing Poisson noise limited performance for signals significantly above the noise floor.
△ Less
Submitted 23 July, 2012; v1 submitted 27 March, 2012;
originally announced March 2012.
-
Simulation study of the impact of AGIPD design choices on X-ray Photon Correlation Spectroscopy utilizing the intensity autocorrelation technique
Authors:
Julian Becker,
Christian Gutt,
Heinz Graafsma
Abstract:
The European XFEL, currently under construction, will produce a coherent X-ray pulse every 222 ns in pulse trains of up to 2700 pulses. In conjunction with the fast 2D area detectors currently under development, it will be possible to perform X-ray Photon Correlation Spectroscopy (XPCS) experiments on sub-microsecond timescales with non-ergodic systems.
A case study for the Adaptive Gain Integra…
▽ More
The European XFEL, currently under construction, will produce a coherent X-ray pulse every 222 ns in pulse trains of up to 2700 pulses. In conjunction with the fast 2D area detectors currently under development, it will be possible to perform X-ray Photon Correlation Spectroscopy (XPCS) experiments on sub-microsecond timescales with non-ergodic systems.
A case study for the Adaptive Gain Integrating Pixel Detector (AGIPD) at the European XFEL employing the intensity autocorrelation technique was performed using the detector simulation tool HORUS. As optimum results from XPCS experiments are obtained when the pixel size approximates the (small) speckle size, the presented study compares the AGIPD (pixel size of (200 $\upmu$m)$^2$) to a possible apertured version of the detector and to a hypothetical system with (100 $\upmu$m)$^2$ pixel size and investigates the influence of intensity fluctuations and incoherent noise on the quality of the acquired data.
The intuitive conclusion that aperturing is not beneficial as data is 'thrown away' was proven to be correct for low intensities. For intensities larger than approximately 1 photon per (100 $\upmu$m)$^2$ aperturing was found to be beneficial, as charge sharing effects were excluded by it.
It was shown that for the investigated case (100 $\upmu$m)$^2$ pixels produced significantly better results than (200 $\upmu$m)$^2$ pixels when the average intensity exceeded approximately 0.05 photons per (100 $\upmu$m)$^2$.
Although the systems were quite different in design they varied in the signal to noise ratio only by a factor of 2-3, and even less in the relative error of the extracted correlation constants. However the dependence on intensity showed distinctively different features for the different systems.
△ Less
Submitted 7 November, 2011; v1 submitted 15 August, 2011;
originally announced August 2011.