-
Time-of-Flight Photoelectron Momentum Microscopy at 100-500 MHz Synchrotron Sources: Electron-Optical Chop** or Bandwidth Pre-Selection
Authors:
G. Schoenhense,
K. Medjanik,
O. Fedchenko,
A. Zymakova,
S. Chernov,
D. Vasilyev,
S. Babenkov,
H. J. Elmers,
P. Baumgärtel,
P. Goslawski,
G. Oehrwall,
M. Ellguth,
A. Oelsner
Abstract:
The small time gap of synchrotron radiation in conventional multi-bunch mode (100-500MHz) is prohibitive for time-of-flight (ToF) based electron spectroscopy. Even the new generation of delay-line detectors with improved time resolution (<100ps) yields only 20-100 resolved time slices within a 2-10ns gap. Here we present two techniques of implementing efficient ToF recording at sources with high r…
▽ More
The small time gap of synchrotron radiation in conventional multi-bunch mode (100-500MHz) is prohibitive for time-of-flight (ToF) based electron spectroscopy. Even the new generation of delay-line detectors with improved time resolution (<100ps) yields only 20-100 resolved time slices within a 2-10ns gap. Here we present two techniques of implementing efficient ToF recording at sources with high repetition rate. A fast electron-optical beam blanking unit with GHz bandwidth, integrated in a photoelectron momentum microscope, allows chop** the photon-pulse train to any desired repetition period. Aberration-free momentum distributions have been recorded at chopped pulse periods of 5MHz (at MAX II) and 1.25MHz (at BESSY II). The approach is benchmarked against the alternative way of implementing a dispersive element, e.g. a hemispherical analyzer, in the electron optics. Both approaches, chop** in the time domain as well as bandpass pre-selection in the energy domain, can enable efficient ToF spectroscopy, spectroscopic real-space imaging and momentum microscopy with few-meV resolution using 100-500MHz Synchrotron radiation, highly-repetitive lasers or cavity-enhanced high-harmonic sources. For comparison, we show results recorded at BESSY II with a parasitic 4-bunch island-orbit pulse train, coexisting with the 500MHz filling pattern on the main orbit.
△ Less
Submitted 1 May, 2021;
originally announced May 2021.
-
Transverse resonance island buckets for synchrotron-radiation based electron time-of-flight spectroscopy
Authors:
T. Arion,
W. Eberhardt,
J. Feikes,
A. Gottwald,
P. Goslawski,
A. Hoehl,
H. Kaser,
M. Kolbe,
J. Li,
C. Lupulescu,
M. Richter,
M. Ries,
F. Roth,
M. Ruprecht,
T. Tydecks,
G. Wüstefeld
Abstract:
At the Metrology Light Source (MLS), the compact electron storage ring of the Physikalisch-Technische Bundesanstalt (PTB) with a circumference of 48\,m, a specific operation mode with two stable closed orbits for stored electrons was realized by transverse resonance island buckets. One of these orbits is closing only after three turns. In combination with single-bunch operation, the new mode was a…
▽ More
At the Metrology Light Source (MLS), the compact electron storage ring of the Physikalisch-Technische Bundesanstalt (PTB) with a circumference of 48\,m, a specific operation mode with two stable closed orbits for stored electrons was realized by transverse resonance island buckets. One of these orbits is closing only after three turns. In combination with single-bunch operation, the new mode was applied for electron time-of-flight spectroscopy with an interval of the synchrotron radiation pulses which is three times the revolution period at the MLS of 160\,ns. The achievement is of significant importance for PTB's future programs of angular-resolved electron spectroscopy with synchrotron radiation and similar projects at other compact electron storage rings. Moreover, the applied scheme for orbit and source spot selection via optical imaging at the insertion device beamline of the MLS and may be relevant for the BESSY VSR project of the Helmholtz-Zentrum Berlin.
△ Less
Submitted 26 June, 2018;
originally announced June 2018.
-
Toward polarized antiprotons: Machine development for spin-filtering experiments
Authors:
C. Weidemann,
F. Rathmann,
H. J. Stein,
B. Lorentz,
Z. Bagdasarian,
L. Barion,
S. Barsov,
U. Bechstedt,
S. Bertelli,
D. Chiladze,
G. Ciullo,
M. Contalbrigo,
S. Dymov,
R. Engels,
M. Gaisser,
R. Gebel,
P. Goslawski,
K. Grigoriev,
G. Guidoboni,
A. Kacharava,
V. Kamerdzhiev,
A. Khoukaz,
A. Kulikov,
A. Lehrach,
P. Lenisa
, et al. (32 additional authors not shown)
Abstract:
The paper describes the commissioning of the experimental equipment and the machine studies required for the first spin-filtering experiment with protons at a beam kinetic energy of $49.3\,$MeV in COSY. The implementation of a low-$β$ insertion made it possible to achieve beam lifetimes of $τ_{\rm{b}}=8000\,$s in the presence of a dense polarized hydrogen storage-cell target of areal density…
▽ More
The paper describes the commissioning of the experimental equipment and the machine studies required for the first spin-filtering experiment with protons at a beam kinetic energy of $49.3\,$MeV in COSY. The implementation of a low-$β$ insertion made it possible to achieve beam lifetimes of $τ_{\rm{b}}=8000\,$s in the presence of a dense polarized hydrogen storage-cell target of areal density $d_{\rm t}=(5.5\pm 0.2)\times 10^{13}\,\mathrm{atoms/cm^{2}}$. The developed techniques can be directly applied to antiproton machines and allow for the determination of the spin-dependent $\bar{p}p$ cross sections via spin filtering.
△ Less
Submitted 9 March, 2015; v1 submitted 24 July, 2014;
originally announced July 2014.
-
High precision beam momentum determination in a synchrotron using a spin resonance method
Authors:
P. Goslawski,
A. Khoukaz,
R. Gebel,
M. Hartmann,
A. Kacharava,
A. Lehrach,
B. Lorentz,
R. Maier,
M. Mielke,
M. Papenbrock,
D. Prasuhn,
R. Stassen,
H. J. Stein,
H. Stockhorst,
H. Ströher,
C. Wilkin
Abstract:
In order to measure the mass of the eta meson with high accuracy using the d+p -> 3He+eta reaction, the momentum of the circulating deuteron beam in the Cooler Synchrotron COSY of the Forschungszentrum Juelich has to be determined with unprecedented precision. This has been achieved by studying the spin dynamics of the polarized deuteron beam. By depolarizing the beam through the use of an artif…
▽ More
In order to measure the mass of the eta meson with high accuracy using the d+p -> 3He+eta reaction, the momentum of the circulating deuteron beam in the Cooler Synchrotron COSY of the Forschungszentrum Juelich has to be determined with unprecedented precision. This has been achieved by studying the spin dynamics of the polarized deuteron beam. By depolarizing the beam through the use of an artificially induced spin resonance, it was possible to evaluate its momentum p with a precision of dp/p < 10-4 for a momentum of roughly 3 GeV/c. Different possible sources of error in the application of the spin resonance method are discussed in detail and its possible use during a standard experiment is considered.
△ Less
Submitted 26 February, 2010; v1 submitted 21 August, 2009;
originally announced August 2009.