-
High spatial coherence and short pulse duration revealed by the Hanbury Brown and Twiss interferometry at the European XFEL
Authors:
Ruslan Khubbutdinov,
Natalia Gerasimova,
Giuseppe Mercurio,
Dameli Assalauova,
Jerome Carnis,
Luca Gelisio,
Loïc le Guyader,
Alexandr Ignatenko,
Young Yong Kim,
Benjamin van Kuiken,
Ruslan P. Kurta,
Dmitry Lapkin,
Martin Teichmann,
Alexander Yaroslavtsev,
Oleg Gorobtsov,
Aleksey P. Menushenkov,
Matthias Scholz,
Andreas Scherz,
Ivan A. Vartanyants
Abstract:
Second-order intensity interferometry was employed to study the spatial and temporal properties of the European X-ray Free-Electron Laser (EuXFEL). Measurements were performed at the soft X-ray SASE3 undulator beamline at a photon energy of 1.2 keV in the Self-Amplified Spontaneous Emission (SASE) mode. Two high-power regimes of the SASE3 undulator settings, i.e. linear and quadratic tapering at s…
▽ More
Second-order intensity interferometry was employed to study the spatial and temporal properties of the European X-ray Free-Electron Laser (EuXFEL). Measurements were performed at the soft X-ray SASE3 undulator beamline at a photon energy of 1.2 keV in the Self-Amplified Spontaneous Emission (SASE) mode. Two high-power regimes of the SASE3 undulator settings, i.e. linear and quadratic tapering at saturation, were studied in detail and compared with the linear gain regime. The statistical analysis showed an exceptionally high degree of spatial coherence up to 90% for the linear undulator tapering. Analysis of the measured data in spectral and spatial domains provided an average pulse duration of about 10 fs in our measurements. The obtained results will be valuable for the experiments requiring and exploiting short pulse duration and utilizing high coherence properties of the EuXFEL.
△ Less
Submitted 22 April, 2021;
originally announced April 2021.
-
Femtosecond laser produced periodic plasma in a colloidal crystal probed by XFEL radiation
Authors:
Nastasia Mukharamova,
Sergey Lazarev,
Janne-Mieke Meijer,
Oleg Yu. Gorobtsov,
Andrej Singer,
Matthieu Chollet,
Michael Bussmann,
Dmitry Dzhigaev,
Yi** Feng,
Marco Garten,
Axel Huebl,
Thomas Kluge,
Ruslan P. Kurta,
Vladimir Lipp,
Robin Santra,
Marcin Sikorski,
Sanghoon Song,
Garth Williams,
Diling Zhu,
Beata Ziaja-Motyka,
Thomas Cowan,
Andrei V. Petukhov,
Ivan A. Vartanyants
Abstract:
With the rapid development of short-pulse intense laser sources, studies of matter under extreme irradiation conditions enter further unexplored regimes. In addition, an application of X-ray Free- Electron Lasers (XFELs), delivering intense femtosecond X-ray pulses allows to investigate sample evolution in IR pump - X-ray probe experiments with an unprecedented time resolution. Here we present the…
▽ More
With the rapid development of short-pulse intense laser sources, studies of matter under extreme irradiation conditions enter further unexplored regimes. In addition, an application of X-ray Free- Electron Lasers (XFELs), delivering intense femtosecond X-ray pulses allows to investigate sample evolution in IR pump - X-ray probe experiments with an unprecedented time resolution. Here we present the detailed study of periodic plasma created from the colloidal crystal. Both experimental data and theory modeling show that the periodicity in the sample survives to a large extent the extreme excitation and shock wave propagation inside the colloidal crystal. This feature enables probing the excited crystal, using the powerful Bragg peak analysis, in contrast to the conventional studies of dense plasma created from bulk samples for which probing with Bragg diffraction technique is not possible. X-ray diffraction measurements of excited colloidal crystals may then lead towards a better understanding of matter phase transitions under extreme irradiation conditions.
△ Less
Submitted 9 November, 2019;
originally announced November 2019.
-
ROSA: Reconstruction of Spectrogram Autocorrelation for Self-Amplified Spontaneous Emission Free-Electron Lasers
Authors:
Svitozar Serkez,
Oleg Gorobtsov,
Bohdana Sobko,
Natalia Gerasimova,
Gianluca Geloni
Abstract:
In recent years X-ray Free Electron Lasers (XFELs) proved to be unmatched sources of ultrashort pulses of spatially coherent quasimonochromatic X-ray radiation. Diagnostics of XFEL emission properties, in particular pulse duration, spectrum and temporal profile is extremely important in order to analyze the experimental results. In this paper we propose a cost-effective method to examine these pro…
▽ More
In recent years X-ray Free Electron Lasers (XFELs) proved to be unmatched sources of ultrashort pulses of spatially coherent quasimonochromatic X-ray radiation. Diagnostics of XFEL emission properties, in particular pulse duration, spectrum and temporal profile is extremely important in order to analyze the experimental results. In this paper we propose a cost-effective method to examine these properties of Self-Amplified Spontaneous Emission (SASE) pulses. It only requires an ensemble of measured SASE spectra and provides the temporal autocorrelation of the ensemble-averaged Wigner distribution of SASE FEL pulses.
△ Less
Submitted 28 November, 2018;
originally announced November 2018.
-
Ghost Imaging at an XUV Free-Electron Laser
Authors:
Young Yong Kim,
Luca Gelisio,
Giuseppe Mercurio,
Siarhei Dziarzhytski,
Martin Beye,
Lars Bocklage,
Anton Classen,
Christian David,
Oleg Yu. Gorobtsov,
Ruslan Khubbutdinov,
Sergey Lazarev,
Nastasia Mukharamova,
Yury N. Obukhov,
Benedikt Roesner,
Kai Schlage,
Ivan A. Zaluzhnyy,
Guenter Brenner,
Ralf Roehlsberger,
Joachim von Zanthier,
Wilfried Wurth,
Ivan A. Vartanyants
Abstract:
Radiation damage is one of the most severe resolution limiting factors in x-ray imaging, especially relevant to biological samples. One way of circumventing this problem is to exploit correlation-based methods developed in quantum imaging. Among these, there is ghost imaging (GI) in which the image is formed by radiation that has never interacted with the sample. Here, we demonstrate GI at an XUV…
▽ More
Radiation damage is one of the most severe resolution limiting factors in x-ray imaging, especially relevant to biological samples. One way of circumventing this problem is to exploit correlation-based methods developed in quantum imaging. Among these, there is ghost imaging (GI) in which the image is formed by radiation that has never interacted with the sample. Here, we demonstrate GI at an XUV free-electron laser by utilizing correlation techniques. We discuss the experimental challenges, optimal setup, and crucial ingredients to maximize the achievable resolution.
△ Less
Submitted 16 November, 2018;
originally announced November 2018.
-
Seeded x-ray free-electron laser generating radiation with laser statistical properties
Authors:
O. Yu. Gorobtsov,
G. Mercurio,
F. Capotondi,
P. Skopintsev,
S. Lazarev,
I. A. Zaluzhnyy,
M. Danailov,
M. Dell`Angela,
M. Manfredda,
E. Pedersoli,
L. Giannessi,
M. Kiskinova,
K. C. Prince,
W. Wurth,
I. A. Vartanyants
Abstract:
The invention of optical lasers led to a revolution in the field of optics and even to the creation of completely new fields of research such as quantum optics. The reason was their unique statistical and coherence properties. The newly emerging, short-wavelength free-electron lasers (FELs) are sources of very bright coherent extreme-ultraviolet (XUV) and x-ray radiation with pulse durations on th…
▽ More
The invention of optical lasers led to a revolution in the field of optics and even to the creation of completely new fields of research such as quantum optics. The reason was their unique statistical and coherence properties. The newly emerging, short-wavelength free-electron lasers (FELs) are sources of very bright coherent extreme-ultraviolet (XUV) and x-ray radiation with pulse durations on the order of femtoseconds, and are presently considered to be laser sources at these energies. Most existing FELs are highly spatially coherent but in spite of their name, they behave statistically as chaotic sources. Here, we demonstrate experimentally, by combining Hanbury Brown and Twiss (HBT) interferometry with spectral measurements that the seeded XUV FERMI FEL-2 source does indeed behave statistically as a laser. The first steps have been taken towards exploiting the first-order coherence of FELs, and the present work opens the way to quantum optics experiments that strongly rely on high-order statistical properties of the radiation.
△ Less
Submitted 21 July, 2018;
originally announced July 2018.
-
Quantum Imaging with Incoherently Scattered Light from a Free-Electron Laser
Authors:
Raimund Schneider,
Thomas Mehringer,
Giuseppe Mercurio,
Lukas Wenthaus,
Anton Classen,
Günter Brenner,
Oleg Gorobtsov,
Adrian Benz,
Daniel Bhatti,
Lars Bocklage,
Birgit Fischer,
Sergey Lazarev,
Yuri Obukhov,
Kai Schlage,
Petr Skopintsev,
Jochen Wagner,
Felix Waldmann,
Svenja Willing,
Ivan Zaluzhnyy,
Wilfried Wurth,
Ivan A. Vartanyants,
Ralf Röhlsberger,
Joachim von Zanthier
Abstract:
The advent of accelerator-driven free-electron lasers (FEL) has opened new avenues for high-resolution structure determination via diffraction methods that go far beyond conventional x-ray crystallography methods. These techniques rely on coherent scattering processes that require the maintenance of first-order coherence of the radiation field throughout the imaging procedure. Here we show that hi…
▽ More
The advent of accelerator-driven free-electron lasers (FEL) has opened new avenues for high-resolution structure determination via diffraction methods that go far beyond conventional x-ray crystallography methods. These techniques rely on coherent scattering processes that require the maintenance of first-order coherence of the radiation field throughout the imaging procedure. Here we show that higher-order degrees of coherence, displayed in the intensity correlations of incoherently scattered x-rays from an FEL, can be used to image two-dimensional objects with a spatial resolution close to or even below the Abbe limit. This constitutes a new approach towards structure determination based on incoherent processes, including Compton scattering, fluorescence emission or wavefront distortions, generally considered detrimental for imaging applications. Our method is an extension of the landmark intensity correlation measurements of Hanbury Brown and Twiss to higher than second-order paving the way towards determination of structure and dynamics of matter in regimes where coherent imaging methods have intrinsic limitations.
△ Less
Submitted 2 October, 2017;
originally announced October 2017.
-
Diffraction based Hanbury Brown and Twiss interferometry performed at a hard x-ray free-electron laser
Authors:
O. Yu. Gorobtsov,
N. Mukharamova,
S. Lazarev,
M. Chollet,
D. Zhu,
Y. Feng,
R. P. Kurta,
J. -M. Meijer,
G. Williams,
M. Sikorski,
S. Song,
D. Dzhigaev,
S. Serkez,
A. Singer,
A. V. Petukhov,
I. A. Vartanyants
Abstract:
We demonstrate experimentally Hanbury Brown and Twiss (HBT) interferometry at a hard X-ray Free Electron Laser (XFEL) on a sample diffraction patterns. This is different from the traditional approach when HBT interferometry requires direct beam measurements in absence of the sample. HBT analysis was carried out on the Bragg peaks from the colloidal crystals measured at Linac Coherent Light Source…
▽ More
We demonstrate experimentally Hanbury Brown and Twiss (HBT) interferometry at a hard X-ray Free Electron Laser (XFEL) on a sample diffraction patterns. This is different from the traditional approach when HBT interferometry requires direct beam measurements in absence of the sample. HBT analysis was carried out on the Bragg peaks from the colloidal crystals measured at Linac Coherent Light Source (LCLS). We observed high degree (80%) spatial coherence of the full beam and the pulse duration of the monochromatized beam on the order of 11 fs that is significantly shorter than expected from the electron bunch measurements.
△ Less
Submitted 27 July, 2017;
originally announced July 2017.
-
Statistical properties of a free-electron laser revealed by the Hanbury Brown and Twiss interferometry
Authors:
O. Yu. Gorobtsov,
G. Mercurio,
G. Brenner,
U. Lorenz,
N. Gerasimova,
R. P. Kurta,
F. Hieke,
P. Skopintsev,
I. Zaluzhnyy,
S. Lazarev,
D. Dzhigaev,
M. Rose,
A. Singer,
W. Wurth,
I. A. Vartanyants
Abstract:
We present a comprehensive experimental analysis of statistical properties of the self-amplified spontaneous emission (SASE) free-electron laser (FEL) FLASH at DESY in Hamburg by means of Hanbury Brown and Twiss (HBT) interferometry. The experiments were performed at the FEL wavelengths of 5.5 nm, 13.4 nm, and 20.8 nm. We determined the 2-nd order intensity correlation function for all wavelengths…
▽ More
We present a comprehensive experimental analysis of statistical properties of the self-amplified spontaneous emission (SASE) free-electron laser (FEL) FLASH at DESY in Hamburg by means of Hanbury Brown and Twiss (HBT) interferometry. The experiments were performed at the FEL wavelengths of 5.5 nm, 13.4 nm, and 20.8 nm. We determined the 2-nd order intensity correlation function for all wavelengths and different operation conditions of FLASH. In all experiments a high degree of spatial coherence (above 50%) was obtained. Our analysis performed in spatial and spectral domains provided us with the independent measurements of an average pulse duration of the FEL that were below 60 fs. To explain complicated behaviour of the 2-nd order intensity correlation function we developed advanced theoretical model that includes the presence of multiple beams and external positional jitter of the FEL pulses. By this analysis we determined that in most experiments several beams were present in radiating field and in one of the experiments external positional jitter was about 25% of the beam size. We envision that methods developed in our study will be used widely for analysis and diagnostics of the FEL radiation.
△ Less
Submitted 12 November, 2016;
originally announced November 2016.
-
Theoretical study of electronic damage in single particle imaging experiments at XFELs for pulse durations 0.1 - 10 fs
Authors:
O. Yu. Gorobtsov,
U. Lorenz,
N. M. Kabachnik,
I. A. Vartanyants
Abstract:
X-ray free-electron lasers (XFELs) may allow to employ the single particle imaging (SPI) method to determine the structure of macromolecules that do not form stable crystals. Ultrashort pulses of 10 fs and less allow to outrun complete disintegration by Coulomb explosion and minimize radiation damage due to nuclear motion, but electronic damage is still present. The major contribution to the elect…
▽ More
X-ray free-electron lasers (XFELs) may allow to employ the single particle imaging (SPI) method to determine the structure of macromolecules that do not form stable crystals. Ultrashort pulses of 10 fs and less allow to outrun complete disintegration by Coulomb explosion and minimize radiation damage due to nuclear motion, but electronic damage is still present. The major contribution to the electronic damage comes from the plasma generated in the sample that is strongly dependent on the amount of Auger ionization. Since the Auger process has a characteristic time scale on the order of femtoseconds, one may expect that its contribution will be significantly reduced for attosecond pulses. Here, we study the effect of electronic damage on the SPI at pulse durations from 0.1 fs to 10 fs and in a large range of XFEL fluences to determine optimal conditions for imaging of biological samples. We analyzed the contribution of different electronic excitation processes and found that at fluences higher than $10^{13}$-$10^{15}$ photons/$μ$m$^2$ (depending on the photon energy and pulse duration) the diffracted signal saturates and does not increase further. A significant gain in the signal is obtained by reducing the pulse duration from 10 fs to 1 fs. Pulses below 1 fs duration do not give a significant gain in the scattering signal in comparison with 1 fs pulses. We also study the limits imposed on SPI by Compton scattering.
△ Less
Submitted 28 April, 2015;
originally announced April 2015.
-
Water Window Ptychographic Imaging with Characterized Coherent X-rays
Authors:
Max Rose,
Petr Skopintsev,
Dmitry Dzhigaev,
Oleg Gorobtsov,
Tobias Senkbeil,
Andreas von Gundlach,
Thomas Gorniak,
Anatoly Shabalin,
Jens Viefhaus,
Axel Rosenhahn,
Ivan Vartanyants
Abstract:
We report on a ptychographical coherent diffractive imaging experiment in the water window with focused soft X-rays at $500~\mathrm{eV}$. An X-ray beam with high degree of coherence was selected for ptychography at the P04 beamline of the PETRA III synchrotron radiation source. We measured the beam coherence with the newly developed non-redundant array method. A pinhole $2.6~\mathrm{μm}$ in size s…
▽ More
We report on a ptychographical coherent diffractive imaging experiment in the water window with focused soft X-rays at $500~\mathrm{eV}$. An X-ray beam with high degree of coherence was selected for ptychography at the P04 beamline of the PETRA III synchrotron radiation source. We measured the beam coherence with the newly developed non-redundant array method. A pinhole $2.6~\mathrm{μm}$ in size selected the coherent part of the beam and was used for ptychographic measurements of a lithographically manufactured test sample and fossil diatom. The achieved resolution was $53~\mathrm{nm}$ for the test sample and only limited by the size of the detector. The diatom was imaged at a resolution better than $90~\mathrm{nm}$.
△ Less
Submitted 10 January, 2015;
originally announced January 2015.
-
Characterization of Spatial Coherence of Synchrotron Radiation with Non-Redundant Arrays of Apertures
Authors:
P. Skopintsev,
A. Singer,
J. Bach,
L. Muller,
B. Beyersdorf,
S. Schleitzer,
O. Gorobtsov,
A. Shabalin,
R. Kurta,
D. Dzhigaev,
O. M. Yefanov,
L. Glaser,
A. Sakdinawat,
Y. Liu,
G. Grubel,
R. Fromter,
H. P. Oepen,
J. Viefhaus,
I. A. Vartanyants
Abstract:
We present a method to characterize the spatial coherence of soft X-ray radiation from a single diffraction pattern. The technique is based on scattering from non-redundant arrays (NRA) of slits and records the degree of spatial coherence at several relative separations from one to 15 microns, simultaneously. Using NRAs we measured the transverse coherence of the X-ray beam at the XUV X-ray beamli…
▽ More
We present a method to characterize the spatial coherence of soft X-ray radiation from a single diffraction pattern. The technique is based on scattering from non-redundant arrays (NRA) of slits and records the degree of spatial coherence at several relative separations from one to 15 microns, simultaneously. Using NRAs we measured the transverse coherence of the X-ray beam at the XUV X-ray beamline P04 of the PETRA III synchrotron storage ring as a function of different beam parameters. To verify the results obtained with the NRAs additional Young's double pinhole experiments were conducted and show good agreement.
△ Less
Submitted 25 February, 2014;
originally announced February 2014.
-
Intensity interferometry of single x-ray pulses from a synchrotron storage ring
Authors:
A. Singer,
U. Lorenz,
A. Marras,
A. Klyuev,
J. Becker,
K. Schlage,
P. Skopintsev,
O. Gorobtsov,
A. Shabalin,
H. -C. Wille,
H. Franz,
H. Graafsma,
I. A. Vartanyants
Abstract:
We report on measurements of second-order intensity correlations at the high brilliance storage ring PETRA III using a prototype of the newly developed Adaptive Gain Integrating Pixel Detector (AGIPD). The detector recorded individual synchrotron radiation pulses with an x-ray photon energy of 14.4 keV and repetition rate of about 5 MHz. The second-order intensity correlation function was measured…
▽ More
We report on measurements of second-order intensity correlations at the high brilliance storage ring PETRA III using a prototype of the newly developed Adaptive Gain Integrating Pixel Detector (AGIPD). The detector recorded individual synchrotron radiation pulses with an x-ray photon energy of 14.4 keV and repetition rate of about 5 MHz. The second-order intensity correlation function was measured simultaneously at different spatial separations that allowed to determine the transverse coherence length at these x-ray energies. The measured values are in a good agreement with theoretical simulations based on the Gaussian Schell-model.
△ Less
Submitted 13 February, 2014;
originally announced February 2014.
-
Spectrometer for Hard X-Ray Free Electron Laser Based on Diffraction Focusing
Authors:
V. G. Kohn,
O. Y. Gorobtsov,
I. A. Vartanyants
Abstract:
X-ray free electron lasers (XFELs) generate sequences of ultra-short, spatially coherent pulses of x-ray radiation. We propose the diffraction focusing spectrometer (DFS), which is able to measure the whole energy spectrum of the radiation of a single XFEL pulse with an energy resolution of $ΔE/E\approx 2\times 10^{-6}$. This is much better than for most modern x-ray spectrometers. Such resolution…
▽ More
X-ray free electron lasers (XFELs) generate sequences of ultra-short, spatially coherent pulses of x-ray radiation. We propose the diffraction focusing spectrometer (DFS), which is able to measure the whole energy spectrum of the radiation of a single XFEL pulse with an energy resolution of $ΔE/E\approx 2\times 10^{-6}$. This is much better than for most modern x-ray spectrometers. Such resolution allows one to resolve the fine spectral structure of the XFEL pulse. The effect of diffraction focusing occurs in a single crystal plate due to dynamical scattering, and is similar to focusing in a Pendry lens made from the metamaterial with a negative refraction index. Such a spectrometer is easier to operate than those based on bent crystals. We show that the DFS can be used in a wide energy range from 5 keV to 20 keV.
△ Less
Submitted 15 November, 2012;
originally announced November 2012.