-
Lessons learnt from the recent EURADOS intercomparisons in computational dosimetry
Authors:
Hans Rabus,
Maria Zankl,
Jose Maria Gomez-Ros,
Carmen Villagrasa,
Jonathan Eakins,
Christelle Huet,
Hrvoje Brkic,
Rick Tanner
Abstract:
Organized by Working Group 6 "Computational Dosimetry" of the European Radiation Dosimetry Group (EURADOS), a group of intercomparison exercises was conducted in which participants were asked to solve predefined problems in computational dosimetry. The results of these comparisons were published in a series of articles in this virtual special issue of Radiation Measurements. This paper reviews the…
▽ More
Organized by Working Group 6 "Computational Dosimetry" of the European Radiation Dosimetry Group (EURADOS), a group of intercomparison exercises was conducted in which participants were asked to solve predefined problems in computational dosimetry. The results of these comparisons were published in a series of articles in this virtual special issue of Radiation Measurements. This paper reviews the experience gained from the various exercises and highlights the resulting conclusions for future exercises, as well as regarding the state of the art and the need for development in terms of quality assurance for computational dosimetry techniques.
△ Less
Submitted 15 May, 2022;
originally announced May 2022.
-
Results of the EURADOS international comparison exercise on neutron spectra unfolding in Bonner spheres spectrometry
Authors:
J. M. Gómez-Ros,
R. Bedogni,
C. Domingo,
J. S. Eakins,
N. Roberts,
R. J. Tanner
Abstract:
This paper summarizes the results obtained from an international comparison exercise on neutron spectra unfolding in Bonner spheres spectrometry, organized within the activities of EURADOS working group 6: computational dosimetry. Four realistic situations were considered: a medical accelerator, a workplace field, an irradiation room and a skyshine scenario. The reference solutions are presented,…
▽ More
This paper summarizes the results obtained from an international comparison exercise on neutron spectra unfolding in Bonner spheres spectrometry, organized within the activities of EURADOS working group 6: computational dosimetry. Four realistic situations were considered: a medical accelerator, a workplace field, an irradiation room and a skyshine scenario. The reference solutions are presented, given in terms of idealized fluence-energy distributions and dose rates, along with details of their derivation using verified Monte Carlo codes. The wide variety of unfolded results that were submitted by the participants are then provided, with some shown to agree well with the reference solutions but others showing significant energy-dependent discrepancies. Finally, explanations for some of these discrepancies are proposed, along with suggested methods for how they might be improved.
△ Less
Submitted 21 April, 2022; v1 submitted 4 January, 2022;
originally announced January 2022.
-
Monte Carlo calculation of the organ equivalent dose and effective dose due to immersion in a 16N beta source in air using the ICRP Reference Phantoms
Authors:
Jose M. Gomez-Ros,
Montserrat Moraleda,
Pedro Arce,
Duc-Ky Bui,
Thi-My-Linh Dang,
Laurent Desorgher,
Han Sung Kim,
Dragana Krstic,
Michal Kuc,
Ngoc-Thiem Le,
Yi-Kang Lee,
Ngoc-Quynh Nguyen,
Dragoslav Nikezic,
Katarzyna Tyminska,
Tomas Vrba
Abstract:
This work summarises the results of a comparison organized by EURADOS focused on the usage of the ICRP Reference Computational Phantoms. This activity aimed to provide training for the implementation of voxel phantoms in Monte Carlo radiation transport codes and the calculation of the dose equivalent in organs and the effective dose. This particular case describes a scenario of immersion in a 16N…
▽ More
This work summarises the results of a comparison organized by EURADOS focused on the usage of the ICRP Reference Computational Phantoms. This activity aimed to provide training for the implementation of voxel phantoms in Monte Carlo radiation transport codes and the calculation of the dose equivalent in organs and the effective dose. This particular case describes a scenario of immersion in a 16N beta source distributed in the air of a room with concrete walls where the phantom is located. Seven participants took part in the comparison of results using GEANT4, TRIPOLI-4 and MCNP family codes, and there was detected a general problem when calculating the dose to skeletal tissue and the remainder tissue. After a process of feedback with the participants the errors were corrected and the final results reached an agreement of +/-5%.
△ Less
Submitted 7 December, 2021;
originally announced December 2021.
-
Development of gamma insensitive silicon carbide diagnostics to qualify intense thermal and epithermal neutron fields
Authors:
O. Sans Planell,
M. Costa,
E. Durisi,
A. Lega,
E. Mafucci,
L. Menzio,
V. Monti,
L. Visca,
R. Bedogni,
M. Treccani,
A. Pola,
D. Bortot,
K. Alikaniotis,
G. Giannini,
J. M. Gomez-Ros
Abstract:
The e_LiBANS project aims at creating accelerator based compact neutron facilities for diverse interdisciplinary applications. After the successful setting up and characterization of a thermal neutron source based on a medical electron LINAC, a similar assembly for epithermal neutrons has been developed. The project is based on an Elekta 18 MV LINAC coupled with a photoconverter-moderator system w…
▽ More
The e_LiBANS project aims at creating accelerator based compact neutron facilities for diverse interdisciplinary applications. After the successful setting up and characterization of a thermal neutron source based on a medical electron LINAC, a similar assembly for epithermal neutrons has been developed. The project is based on an Elekta 18 MV LINAC coupled with a photoconverter-moderator system which deploys the (γ,n) photonuclear reaction to convert a bremsstrahlung photon beam into a neutron field. This communication describes the development of novel diagnostics to qualify the thermal and epithermal neutron fields that have been produced. In particular, a proof of concept for the use of silicon carbide photodiodes as a thermal neutron rate detector is presented.
△ Less
Submitted 17 April, 2020;
originally announced April 2020.
-
The e_LiBANS facility: a new compact thermal neutron source based on a medical electron LINAC
Authors:
Valeria Monti,
Marco Costa,
Elisabetta Durisi,
Ettore Mafucci,
Luca Menzio,
Oriol Sans-Planell,
Lorenzo Visca,
Roberto Bedogni,
Matteo Treccani,
Andrea Pola,
Davide Bortot,
Katia Alikaniotis,
Gianrossano Giannini,
Jose Maria Gomez-Ros
Abstract:
A new photonuclear thermal neutron facility has been developed at the Physics Department of University of Torino. The facility is based on a medical electron LINAC coupled to a compact converter and moderator assembly. A homogenous thermal neutron field of the order of 10$^6$ cm$^{-2}$s$^{-1}$ is achievable in the enclosed irradiation cavity with low gamma and fast neutron contaminations. Its inte…
▽ More
A new photonuclear thermal neutron facility has been developed at the Physics Department of University of Torino. The facility is based on a medical electron LINAC coupled to a compact converter and moderator assembly. A homogenous thermal neutron field of the order of 10$^6$ cm$^{-2}$s$^{-1}$ is achievable in the enclosed irradiation cavity with low gamma and fast neutron contaminations. Its intensity can be tuned varying the LINAC current. These characteristics make the source appropriate for several applications like detectors development, material studies and BNCT preclinical research. This work describes the project and the experimental characterization of the facility. This includes the measurement of the thermal neutron fluence rate, the determination of the neutron energy spectrum and of the thermal neutron field uniformity and the evaluation of the gamma contamination.
△ Less
Submitted 2 September, 2019;
originally announced September 2019.
-
Results of the first user program on the Homogenous Thermal Neutron Source HOTNES (ENEA / INFN)
Authors:
A. Sperduti,
M. Angelone,
R. Bedogni,
G. Claps,
E. Diociaiuti,
C. Domingo,
R. Donghia,
S. Giovannella,
J. M. Gomez-Ros,
L. Irazola-Rosales,
S. Loreti,
V. Monti,
S. Miscetti,
F. Murtas,
G. Pagano,
M. Pillon,
R. Pilotti,
A. Pola,
M. Romero-Expósito,
F. Sánchez-Doblado,
O. Sans-Planell,
A. Scherillo,
E. Soldani,
M. Treccani,
A. Pietropaolo
Abstract:
The HOmogeneous Thermal NEutron Source (HOTNES) is a new type of thermal neutron irradiation assembly developed by the ENEA-INFN collaboration. The facility is fully characterized in terms of neutron field and dosimetric quantities, by either computational and experimental methods. This paper reports the results of the first "HOTNES users program", carried out in 2016, and covering a variety of th…
▽ More
The HOmogeneous Thermal NEutron Source (HOTNES) is a new type of thermal neutron irradiation assembly developed by the ENEA-INFN collaboration. The facility is fully characterized in terms of neutron field and dosimetric quantities, by either computational and experimental methods. This paper reports the results of the first "HOTNES users program", carried out in 2016, and covering a variety of thermal neutron active detectors such as scintillators, solid-state, single crystal diamond and gaseous detectors.
△ Less
Submitted 22 February, 2018;
originally announced February 2018.