-
Cosmogenic background simulations for the DARWIN observatory at different underground locations
Authors:
M. Adrover,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
B. Antunovic,
E. Aprile,
M. Babicz,
D. Bajpai,
E. Barberio,
L. Baudis,
M. Bazyk,
N. Bell,
L. Bellagamba,
R. Biondi,
Y. Biondi,
A. Bismark,
C. Boehm,
A. Breskin,
E. J. Brookes,
A. Brown,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso
, et al. (158 additional authors not shown)
Abstract:
Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay ($0νββ$), and axion-like particles (ALPs). Although cosmic muons are…
▽ More
Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay ($0νββ$), and axion-like particles (ALPs). Although cosmic muons are a source of background that cannot be entirely eliminated, they may be greatly diminished by placing the detector deep underground. In this study, we used Monte Carlo simulations to model the cosmogenic background expected for the DARWIN observatory at four underground laboratories: Laboratori Nazionali del Gran Sasso (LNGS), Sanford Underground Research Facility (SURF), Laboratoire Souterrain de Modane (LSM) and SNOLAB. We determine the production rates of unstable xenon isotopes and tritium due to muon-included neutron fluxes and muon-induced spallation. These are expected to represent the dominant contributions to cosmogenic backgrounds and thus the most relevant for site selection.
△ Less
Submitted 28 June, 2023;
originally announced June 2023.
-
Electron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator
Authors:
L. Baudis,
Y. Biondi,
A. Bismark,
A. P. Cimental Chavez,
J. J. Cuenca-Garcia,
J. Franchi,
M. Galloway,
F. Girard,
R. Peres,
D. Ramirez Garcia,
P. Sanchez-Lucas,
K. Thieme,
C. Wittweg
Abstract:
There is a compelling physics case for a large, xenon-based underground detector devoted to dark matter and other rare-event searches. A two-phase time projection chamber as inner detector allows for a good energy resolution, a three-dimensional position determination of the interaction site and particle discrimination. To study challenges related to the construction and operation of a multi-tonne…
▽ More
There is a compelling physics case for a large, xenon-based underground detector devoted to dark matter and other rare-event searches. A two-phase time projection chamber as inner detector allows for a good energy resolution, a three-dimensional position determination of the interaction site and particle discrimination. To study challenges related to the construction and operation of a multi-tonne scale detector, we have designed and constructed a vertical, full-scale demonstrator for the DARWIN experiment at the University of Zurich. Here we present first results from a several-months run with 343 kg of xenon and electron drift lifetime and transport measurements with a 53 cm tall purity monitor immersed in the cryogenic liquid. After 88 days of continuous purification, the electron lifetime reached a value of 664(23) microseconds. We measured the drift velocity of electrons for electric fields in the range (25--75) V/cm, and found values consistent with previous measurements. We also calculated the longitudinal diffusion constant of the electron cloud in the same field range, and compared with previous data, as well as with predictions from an empirical model.
△ Less
Submitted 12 December, 2023; v1 submitted 24 March, 2023;
originally announced March 2023.
-
Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors
Authors:
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
D. Durnford,
S. Fallows,
J. Farine,
R. Filgas,
A. García-Viltres,
F. Girard,
G. Giroux,
O. Harris,
E. W. Hoppe,
C. M. Jackson,
M. **,
C. B. Krauss
, et al. (32 additional authors not shown)
Abstract:
The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct…
▽ More
The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.
△ Less
Submitted 7 November, 2022; v1 submitted 11 May, 2022;
originally announced May 2022.
-
GPU-based optical simulation of the DARWIN detector
Authors:
L. Althueser,
B. Antunović,
E. Aprile,
D. Bajpai,
L. Baudis,
D. Baur,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
Y. Biondi,
A. Bismark,
A. Brown,
R. Budnik,
A. Chauvin,
A. P. Colijn,
J. J. Cuenca-García,
V. D'Andrea,
P. Di Gangi,
J. Dierle,
S. Diglio,
M. Doerenkamp,
K. Eitel,
S. Farrell,
A. D. Ferella,
C. Ferrari
, et al. (55 additional authors not shown)
Abstract:
Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing effi…
▽ More
Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.
△ Less
Submitted 11 July, 2022; v1 submitted 27 March, 2022;
originally announced March 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Design and construction of Xenoscope -- a full-scale vertical demonstrator for the DARWIN observatory
Authors:
L. Baudis,
Y. Biondi,
M. Galloway,
F. Girard,
A. Manfredini,
N. McFadden,
R. Peres,
P. Sanchez-Lucas,
K. Thieme
Abstract:
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and other rare interactions. It will operate a 50 t liquid xenon detector, with 40 t in the time projection chamber (TPC). To inform the final detector design and technical choices, a series of technological questions must first be addressed. Here we describe a full-scale demonstrator in the vertical…
▽ More
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and other rare interactions. It will operate a 50 t liquid xenon detector, with 40 t in the time projection chamber (TPC). To inform the final detector design and technical choices, a series of technological questions must first be addressed. Here we describe a full-scale demonstrator in the vertical dimension, Xenoscope, with the main goal of achieving electron drift over a 2.6 m distance, which is the scale of the DARWIN TPC. We have designed and constructed the facility infrastructure, including the cryostat, cryogenic and purification systems, the xenon storage and recuperation system, as well as the slow control system. We have also designed a xenon purity monitor and the TPC, with the fabrication of the former nearly complete. In a first commissioning run of the facility without an inner detector, we demonstrated the nominal operational reach of Xenoscope and benchmarked the components of the cryogenic and slow control systems, demonstrating reliable and continuous operation of all subsystems over 40 days. The infrastructure is thus ready for the integration of the purity monitor, followed by the TPC. Further applications of the facility include R&D on the high voltage feedthrough for DARWIN, measurements of electron cloud diffusion, as well as measurements of optical properties of liquid xenon. In the future, Xenoscope will be available as a test platform for the DARWIN collaboration to characterise new detector technologies.
△ Less
Submitted 24 August, 2021; v1 submitted 28 May, 2021;
originally announced May 2021.
-
Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering
Authors:
J. Aalbers,
F. Agostini,
S. E. M. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
F. Amaro,
J. Angevaare,
V. C. Antochi,
B. Antunovic,
E. Aprile,
L. Arazi,
F. Arneodo,
M. Balzer,
L. Baudis,
D. Baur,
M. L. Benabderrahmane,
Y. Biondi,
A. Bismark,
C. Bourgeois,
A. Breskin,
P. A. Breur,
A. Brown,
E. Brown,
S. Brünner,
G. Bruno
, et al. (141 additional authors not shown)
Abstract:
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would ben…
▽ More
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would benefit from a depleted target. A high-statistics observation of $pp$ neutrinos would allow us to infer the values of the weak mixing angle, $\sin^2θ_w$, and the electron-type neutrino survival probability, $P_e$, in the electron recoil energy region from a few keV up to 200 keV for the first time, with relative precision of 5% and 4%, respectively, at an exposure of 300 ty. An observation of $pp$ and $^7$Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high (GS98) and low metallicity (AGS09) solar models with 2.1-2.5$σ$ significance, independent of external measurements from other experiments or a measurement of $^8$B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of $^{131}$Xe.
△ Less
Submitted 20 December, 2020; v1 submitted 4 June, 2020;
originally announced June 2020.
-
Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of $^{136}$Xe
Authors:
F. Agostini,
S. E. M. Ahmed Maouloud,
L. Althueser,
F. Amaro,
B. Antunovic,
E. Aprile,
L. Baudis,
D. Baur,
Y. Biondi,
A. Bismark,
P. A. Breur,
A. Brown,
G. Bruno,
R. Budnik,
C. Capelli,
J. Cardoso,
D. Cichon,
M. Clark,
A. P. Colijn,
J. J. Cuenca-García,
J. P. Cussonneau,
M. P. Decowski,
A. Depoian,
J. Dierle,
P. Di Gangi
, et al. (70 additional authors not shown)
Abstract:
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, u…
▽ More
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, using a fiducial volume of 5t of natural xenon and 10$\,$yr of operation with a background rate of less than 0.2$~$events/(t$\cdot$yr) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in $^{136}$Xe.
△ Less
Submitted 7 September, 2020; v1 submitted 25 March, 2020;
originally announced March 2020.
-
The first dual-phase xenon TPC equipped with silicon photomultipliers and characterisation with $^{37}$Ar
Authors:
L. Baudis,
Y. Biondi,
M. Galloway,
F. Girard,
S. Hochrein,
S. Reichard,
P. Sanchez-Lucas,
K. Thieme,
J. Wulf
Abstract:
For the first time, a small dual-phase (liquid/gas) xenon time projection chamber was equipped with a top array of silicon photomultipliers for light and charge readout. Here we describe the instrument in detail, as well as the data processing and the event position reconstruction algorithms. We obtain a spatial resolution of ~1.5 mm in the horizontal plane. To characterise the detector performanc…
▽ More
For the first time, a small dual-phase (liquid/gas) xenon time projection chamber was equipped with a top array of silicon photomultipliers for light and charge readout. Here we describe the instrument in detail, as well as the data processing and the event position reconstruction algorithms. We obtain a spatial resolution of ~1.5 mm in the horizontal plane. To characterise the detector performance, we show calibration data with internal $^{83\text{m}}$Kr and $^{37}$Ar sources, and we detail the production of the latter as well as its introduction into the system. We finally compare the observed light and charge yields down to electronic recoil energies of 2.82 keV to predictions based on NEST v2.0.
△ Less
Submitted 1 November, 2021; v1 submitted 3 March, 2020;
originally announced March 2020.
-
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
S. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
R. Filgas
, et al. (54 additional authors not shown)
Abstract:
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by…
▽ More
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by a hot-spike as previously supposed. Using this semi-empirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c$^{-2}$.
△ Less
Submitted 25 November, 2020; v1 submitted 29 May, 2019;
originally announced May 2019.
-
Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas
, et al. (47 additional authors not shown)
Abstract:
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total backgr…
▽ More
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$ cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.
△ Less
Submitted 11 February, 2019;
originally announced February 2019.
-
Develo** a Bubble Chamber Particle Discriminator Using Semi-Supervised Learning
Authors:
B. Matusch,
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis
, et al. (48 additional authors not shown)
Abstract:
The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually develo** a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing…
▽ More
The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually develo** a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing formats and neural network architectures are applied to the task. First, they are optimized in a supervised learning context. Next, two novel semi-supervised learning algorithms are trained, and found to replicate the Acoustic Parameter (AP) discriminator previously used in PICO-60 with a mean of 97% accuracy.
△ Less
Submitted 27 November, 2018;
originally announced November 2018.
-
Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
P. Campion,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
G. Crowder,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas,
F. Girard
, et al. (37 additional authors not shown)
Abstract:
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less th…
▽ More
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than 1 event per month. A blind analysis of an efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 3.4 $\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one order of magnitude improvement from previous PICO results.
△ Less
Submitted 2 August, 2017; v1 submitted 24 February, 2017;
originally announced February 2017.
-
Improved dark matter search results from PICO-2L Run 2
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
M. Das,
F. Debris,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas,
M. Fines-Neuschild,
F. Girard,
G. Giroux
, et al. (33 additional authors not shown)
Abstract:
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nu…
▽ More
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nuclear-recoil event was observed in the data, consistent both with the predicted background rate from neutrons and with the observed rate of unambiguous multiple-bubble neutron scattering events. The chamber exhibits the same excellent electron-recoil and alpha decay rejection as was previously reported. These data provide the most stringent direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.
△ Less
Submitted 25 March, 2016; v1 submitted 14 January, 2016;
originally announced January 2016.
-
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Authors:
C. Amole,
M. Ardid,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
S. Daley,
M. Das,
F. Debris,
N. Dhungana,
J. Farine,
I. Felis,
R. Filgas,
F. Girard,
G. Giroux,
A. Grandison
, et al. (34 additional authors not shown)
Abstract:
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays…
▽ More
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. These behaviors allow for analysis cuts to remove all background events while retaining $48.2\%$ of the exposure. Stringent limits on weakly interacting massive particles interacting via spin-dependent proton and spin-independent processes are set, and most interpretations of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei are ruled out.
△ Less
Submitted 3 March, 2016; v1 submitted 26 October, 2015;
originally announced October 2015.
-
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
S. Daley,
M. Das,
F. Debris,
N. Dhungana,
J. Farine,
I. Felis,
R. Filgas,
M. Fines-Neuschild,
F. Girard,
G. Giroux
, et al. (32 additional authors not shown)
Abstract:
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation o…
▽ More
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation of a dependence of acoustic signal on alpha energy. Twelve single nuclear recoil event candidates were observed during the run. The candidate events exhibit timing characteristics that are not consistent with the hypothesis of a uniform time distribution, and no evidence for a dark matter signal is claimed. These data provide the most sensitive direct detection constraints on WIMP-proton spin-dependent scattering to date, with significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon scattering.
△ Less
Submitted 29 June, 2015; v1 submitted 27 February, 2015;
originally announced March 2015.