Skip to main content

Showing 1–6 of 6 results for author: Gibbons, R

Searching in archive physics. Search in all archives.
.
  1. arXiv:2406.12874  [pdf, other

    physics.ins-det hep-ex

    The Design, Implementation, and Performance of the LZ Calibration Systems

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, E. E. Barillier, J. W. Bargemann, K. Beattie, T. Benson, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, E. Bishop, G. M. Blockinger, B. Boxer , et al. (179 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low e… ▽ More

    Submitted 20 June, 2024; v1 submitted 2 May, 2024; originally announced June 2024.

  2. arXiv:2405.14732  [pdf, other

    physics.ins-det hep-ex

    The Data Acquisition System of the LZ Dark Matter Detector: FADR

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, S. Balashov, J. Bang, E. E. Barillier, J. W. Bargemann, K. Beattie, T. Benson, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, E. Bishop, G. M. Blockinger, B. Boxer , et al. (190 additional authors not shown)

    Abstract: The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals.… ▽ More

    Submitted 23 May, 2024; originally announced May 2024.

    Comments: 18 pages, 24 figures

  3. arXiv:2309.07913  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Why would you put a flashlight in a dark matter detector?

    Authors: R. Gibbons, H. Chen, S. J. Haselschwardt, Q. Xia, P. Sorensen

    Abstract: Silicon photomultipliers (SiPMs) are solid-state, single-photon sensitive, pixelated sensors whose usage for scintillation detection has rapidly increased over the past decade. It is known that the avalanche process within the device, which renders a single photon detectable, can also generate secondary photons which may be detected by a separate device. This effect, known as external crosstalk, c… ▽ More

    Submitted 15 January, 2024; v1 submitted 14 September, 2023; originally announced September 2023.

    Comments: 12 pages, 6 figures

  4. arXiv:2211.17120  [pdf, other

    hep-ex physics.ins-det

    Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment

    Authors: J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, S. K. Alsum, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, M. Arthurs, A. Baker, J. Bang, J. W. Bargemann, A. Baxter, K. Beattie, P. Beltrame, E. P. Bernard, A. Bhatti, A. Biekert, T. P. Biesiadzinski, H. J. Birch, G. M. Blockinger, B. Boxer , et al. (178 additional authors not shown)

    Abstract: The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-bet… ▽ More

    Submitted 17 July, 2023; v1 submitted 30 November, 2022; originally announced November 2022.

    Comments: 25 pages, 15 figures

    Journal ref: Phys. Rev. D 108, 012010 (2023)

  5. arXiv:2201.05740  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber

    Authors: S. Kravitz, H. Chen, R. Gibbons, S. J. Haselschwardt, Q. Xia, P. Sorensen

    Abstract: We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to tag and reject radon-chain backgrounds, due to t… ▽ More

    Submitted 29 March, 2022; v1 submitted 14 January, 2022; originally announced January 2022.

  6. Large-Scale, Precision Xenon Do** of Liquid Argon

    Authors: N. McFadden, S. R. Elliott, M. Gold, D. E. Fields, K. Rielage, R. Massarczyk, R. Gibbons

    Abstract: The detection of scintillation light from liquid argon is an experimental technique key to a number of current and future nuclear/particle physics experiments, such as neutrino physics, neutrinoless double beta decay and dark matter searches. Although the idea of adding small quantities of xenon (do**) to enhance the light yield has attracted considerable interest, this technique has never been… ▽ More

    Submitted 23 June, 2021; v1 submitted 17 June, 2020; originally announced June 2020.