The Design, Implementation, and Performance of the LZ Calibration Systems
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
E. E. Barillier,
J. W. Bargemann,
K. Beattie,
T. Benson,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer
, et al. (179 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low e…
▽ More
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.
△ Less
Submitted 20 June, 2024; v1 submitted 2 May, 2024;
originally announced June 2024.
-
The Data Acquisition System of the LZ Dark Matter Detector: FADR
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
E. E. Barillier,
J. W. Bargemann,
K. Beattie,
T. Benson,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer
, et al. (190 additional authors not shown)
Abstract:
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals.…
▽ More
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis.
The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition.
The hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.
△ Less
Submitted 23 May, 2024;
originally announced May 2024.
-
Why would you put a flashlight in a dark matter detector?
Authors:
R. Gibbons,
H. Chen,
S. J. Haselschwardt,
Q. Xia,
P. Sorensen
Abstract:
Silicon photomultipliers (SiPMs) are solid-state, single-photon sensitive, pixelated sensors whose usage for scintillation detection has rapidly increased over the past decade. It is known that the avalanche process within the device, which renders a single photon detectable, can also generate secondary photons which may be detected by a separate device. This effect, known as external crosstalk, c…
▽ More
Silicon photomultipliers (SiPMs) are solid-state, single-photon sensitive, pixelated sensors whose usage for scintillation detection has rapidly increased over the past decade. It is known that the avalanche process within the device, which renders a single photon detectable, can also generate secondary photons which may be detected by a separate device. This effect, known as external crosstalk, could potentially degrade the science goals of future xenon dark matter experiments. In this article, we measure the effect of external crosstalk in a dual-phase, liquid xenon time projection chamber fully instrumented with SiPMs. We then consider the implications for a future xenon dark matter experiment utilizing SiPMs and discuss possible solutions.
△ Less
Submitted 15 January, 2024; v1 submitted 14 September, 2023;
originally announced September 2023.
-
Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
J. Bang,
J. W. Bargemann,
A. Baxter,
K. Beattie,
P. Beltrame,
E. P. Bernard,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
G. M. Blockinger,
B. Boxer
, et al. (178 additional authors not shown)
Abstract:
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-bet…
▽ More
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-beta decay searches and effective field theory interpretations of LUX-ZEPLIN data. We confirm that the in-situ determinations of bulk and fixed radioactive backgrounds are consistent with expectations from the ex-situ assays. The observed background rate after WIMP search criteria were applied was $(6.3\pm0.5)\times10^{-5}$ events/keV$_{ee}$/kg/day in the low-energy region, approximately 60 times lower than the equivalent rate reported by the LUX experiment.
△ Less
Submitted 17 July, 2023; v1 submitted 30 November, 2022;
originally announced November 2022.
-
Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber
Authors:
S. Kravitz,
H. Chen,
R. Gibbons,
S. J. Haselschwardt,
Q. Xia,
P. Sorensen
Abstract:
We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to tag and reject radon-chain backgrounds, due to t…
▽ More
We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to tag and reject radon-chain backgrounds, due to the time and energy signature of their decays. The present article is the first demonstration of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.
△ Less
Submitted 29 March, 2022; v1 submitted 14 January, 2022;
originally announced January 2022.
-
Large-Scale, Precision Xenon Do** of Liquid Argon
Authors:
N. McFadden,
S. R. Elliott,
M. Gold,
D. E. Fields,
K. Rielage,
R. Massarczyk,
R. Gibbons
Abstract:
The detection of scintillation light from liquid argon is an experimental technique key to a number of current and future nuclear/particle physics experiments, such as neutrino physics, neutrinoless double beta decay and dark matter searches. Although the idea of adding small quantities of xenon (do**) to enhance the light yield has attracted considerable interest, this technique has never been…
▽ More
The detection of scintillation light from liquid argon is an experimental technique key to a number of current and future nuclear/particle physics experiments, such as neutrino physics, neutrinoless double beta decay and dark matter searches. Although the idea of adding small quantities of xenon (do**) to enhance the light yield has attracted considerable interest, this technique has never been demonstrated at the necessary scale or precision. Here we report on xenon do** in a 100 l cryogenic vessel. Xenon do** was performed in four concentrations of 1.00$\pm$0.06 ppm, 2.0$\pm$0.1 ppm, 5.0$\pm$0.3 ppm, and 10.0$\pm$0.5 ppm. These measurements represent the most precise xenon do** measurements as of publishing. We observed an increase in average light yield by a factor of 1.92$\pm$0.12(syst)$\pm$0.02(stat) at a dopant concentration of 10 ppm.
△ Less
Submitted 23 June, 2021; v1 submitted 17 June, 2020;