A Pilot Study on Coupling CT and MRI through Use of Semiconductor Nanoparticles
Authors:
Matthew Getzin,
Lars Gjesteby,
Yen-Jun Chuang,
Scott McCallum,
Wenxiang Cong,
Chao Wang,
Zhengwei Pan,
Guohao Dai,
Ge Wang
Abstract:
CT and MRI are the two most widely used imaging modalities in healthcare, each with its own merits and drawbacks. Combining these techniques in one machine could provide unprecedented resolution and sensitivity in a single scan, and serve as an ideal platform to explore physical coupling of x-ray excitation and magnetic resonance. Molecular probes such as functionalized nanophosphors present an op…
▽ More
CT and MRI are the two most widely used imaging modalities in healthcare, each with its own merits and drawbacks. Combining these techniques in one machine could provide unprecedented resolution and sensitivity in a single scan, and serve as an ideal platform to explore physical coupling of x-ray excitation and magnetic resonance. Molecular probes such as functionalized nanophosphors present an opportunity to demonstrate a synergy between these modalities. However, a simultaneous CT-MRI scanner does not exist at this moment. As a pilot study, here we propose a mechanism in which water solutions containing LiGa5O8:Cr3+ nanophosphors can be excited with x-rays to store energy, and these excited particles may subsequently influence the T2 relaxation times of the solutions so that a difference in T2 can be measured by MRI before and after x-ray excitation. The trends seen in our study suggest that a measurable effect may exist from x-ray excitation of the nanophosphors. However, there are several experimental conditions that hinder the clarity of the results to be statistically significant up to a commonly accepted level (p=0.05), including insoluble nanoparticles and inter-scan variability. Nevertheless, the initial results from our experiments seem a consistent and inspiring story that x-rays modify MRI T2 values around nanophosphors. Upon availability of soluble nanophosphors, we will repeat our experiments to confirm these observations.
△ Less
Submitted 23 December, 2014;
originally announced December 2014.
X-optogenetics and U-optogenetics: Feasibility and Possibilities
Authors:
Rachel Berry,
Matthew Getzin,
Lars Gjesteby,
Ge Wang
Abstract:
To address these limitations of optogenetics, here we propose two new methods for optogenetic stimulation. The first is x-optogenetics, which uses visible light-emitting nanophosphors stimulated by focused x-rays. This idea is not new but the application to optogenetics is novel. X-rays can penetrate much more deeply than infrared light and could allow for nerve cell stimulation in any part of the…
▽ More
To address these limitations of optogenetics, here we propose two new methods for optogenetic stimulation. The first is x-optogenetics, which uses visible light-emitting nanophosphors stimulated by focused x-rays. This idea is not new but the application to optogenetics is novel. X-rays can penetrate much more deeply than infrared light and could allow for nerve cell stimulation in any part of the brain. In this paper, we discuss the feasibility and possibilities of such a method by describing the advances in nanomaterials, x-ray focusing, and x-ray sources. Also, we discuss concerns when dealing with x-rays such as radiation dosage. Through the use of quantities and assumptions backed by recent literature, manufacturer specifications, and personal correspondence, a full feasibility analysis of x-optogenetics is completed. The second proposed method we explore is u-optogenetics, which is the application of sonoluminescence to optogenetics. Such a technique uses ultrasound waves instead of x-rays to induce light emission, so there would be no introduction of radiation. However, the penetration depth of ultrasound is less than that of x-ray. The key issues affecting feasibility are laid out for further investigation into both x-optogenetics and u-optogenetics.
△ Less
Submitted 18 December, 2014;
originally announced December 2014.