-
A study of scalar optically-pumped magnetometers for use in magnetoencephalography without shielding
Authors:
Richard J. Clancy,
Vladislav Gerginov,
Orang Alem,
Stephen Becker,
Svenja Knappe
Abstract:
Scalar optically-pumped magnetometers (OPMs) are being developed in small packages with high sensitivities. The high common-mode rejection ratio of these sensors allows for detection of very small signals in the presence of large background fields making them ideally suited for brain imaging applications in unshielded environments. Despite a flurry of activity around the topic, questions remain co…
▽ More
Scalar optically-pumped magnetometers (OPMs) are being developed in small packages with high sensitivities. The high common-mode rejection ratio of these sensors allows for detection of very small signals in the presence of large background fields making them ideally suited for brain imaging applications in unshielded environments. Despite a flurry of activity around the topic, questions remain concerning how well a dipolar source can be localized under such conditions, especially when using few sensors. In this paper, we investigate the source localization capabilities using an array of scalar OPMs in the presence of a large background field while varying dipole strength, sensor count, and forward model accuracy. We also consider localization performance as the orientation angle of the background field changes. Our results are validated experimentally through accurate localization using a phantom virtual array mimicking a current dipole in a conducting sphere in a large background field. Our results are intended to give researchers a general sense of the capabilities and limitations of scalar OPMs for magnetoencephalography systems.
△ Less
Submitted 5 May, 2021;
originally announced May 2021.
-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
Gradiometry-free noise suppression in RF atomic magnetometers
Authors:
Vladislav Gerginov
Abstract:
We demonstrate the sensitivity of a sensor based on an optically-pumped radio-frequency (RF) atomic magnetometer to the polarization state of the detected RF magnetic field, and measure $>$36 dB difference in amplitude sensitivity for opposite circular field polarizations. This sensitivity could be used to create novel sensors that would allow signal detection while suppressing the ambient noise,…
▽ More
We demonstrate the sensitivity of a sensor based on an optically-pumped radio-frequency (RF) atomic magnetometer to the polarization state of the detected RF magnetic field, and measure $>$36 dB difference in amplitude sensitivity for opposite circular field polarizations. This sensitivity could be used to create novel sensors that would allow signal detection while suppressing the ambient noise, regardless of the distance between the sources of signal and noise, in contrast to traditional gradiometry configurations. Additionally, such sensor will be orientation-sensitive, as the phase of the detected signal is shown to depend on the angle between the sensor's detection axis and the direction to the transmitter.
△ Less
Submitted 24 September, 2018;
originally announced September 2018.
-
Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks
Authors:
S. Weyers,
V. Gerginov,
M. Kazda,
J. Rahm,
B. Lipphardt,
G. Dobrev,
K. Gibble
Abstract:
Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum…
▽ More
Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum projection noise limited frequency instabilities are improved to $7.2 \times 10^{-14} (τ/1\,\mathrm{s})^{-1/2}$ for CSF1 and $2.5 \times 10^{-14} (τ/1\,\mathrm{s})^{-1/2}$ for CSF2 at high atom density. The systematic uncertainties of CSF1 and CSF2 are reduced to $2.74 \times 10^{-16}$ and $1.71 \times 10^{-16}$, respectively. Both fountain clocks regularly calibrate the scale unit of International Atomic Time (TAI) and the local realization of Coordinated Universal Time, UTC(PTB), and serve as references to measure the frequencies of local and remote optical frequency standards.
△ Less
Submitted 10 September, 2018;
originally announced September 2018.
-
Two-photon optical frequency reference with active ac Stark shift cancellation
Authors:
V. Gerginov,
K. Beloy
Abstract:
An optical reference based on a two-photon optical transition with ac Stark shift cancellation is proposed. The reference uses two interrogating laser fields at different frequencies. Compared to conventional optical two-photon references, the new approach offers the possibility for improved short-term stability resulting from a higher signal-to-noise and improved long-term stability due to active…
▽ More
An optical reference based on a two-photon optical transition with ac Stark shift cancellation is proposed. The reference uses two interrogating laser fields at different frequencies. Compared to conventional optical two-photon references, the new approach offers the possibility for improved short-term stability resulting from a higher signal-to-noise and improved long-term stability due to active ac Stark shift cancellation. We demonstrate the ac Stark shift cancellation method on the $5s\,{^2S}_{1/2} \rightarrow 5d\,{^2D}_{5/2}$ two-photon transition in $^{87}$Rb.
△ Less
Submitted 3 August, 2018;
originally announced August 2018.
-
First international comparison of fountain primary frequency standards via a long distance optical fiber link
Authors:
J. Guéna,
S. Weyers,
M. Abgrall,
C. Grebing,
V. Gerginov,
P. Rosenbusch,
S. Bize,
B. Lipphardt,
H. Denker,
N. Quintin,
S. M. F. Raupach,
D. Nicolodi,
F. Stefani,
N. Chiodo,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
C. Chardonnet,
Y. Le Coq,
M. Lours,
G. Santarelli,
A. Amy-Klein,
R. Le Targat
, et al. (3 additional authors not shown)
Abstract:
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs…
▽ More
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs have been major contributors to accuracy of the International Atomic Time (TAI), with stated accuracies of around $3\times 10^{-16}$. They have also been the references for a number of absolute measurements of clock transition frequencies in various optical frequency standards in view of a future redefinition of the second. The phase coherent optical frequency transfer via a stabilized telecom fiber link enables far better resolution than any other means of frequency transfer based on satellite links. The agreement for each pair of distant fountains compared is well within the combined uncertainty of a few 10$^{-16}$ for all the comparisons, which fully supports the stated PFSs' uncertainties. The comparison also includes a rubidium fountain frequency standard participating in the steering of TAI and enables a new absolute determination of the $^{87}$Rb ground state hyperfine transition frequency with an uncertainty of $3.1\times 10^{-16}$.
This paper is dedicated to the memory of André Clairon, who passed away on the 24$^{th}$ of December 2015, for his pioneering and long-lasting efforts in atomic fountains. He also pioneered optical links from as early as 1997.
△ Less
Submitted 14 March, 2017; v1 submitted 2 March, 2017;
originally announced March 2017.
-
Optical Stabilization of a Microwave Oscillator for Fountain Clock Interrogation
Authors:
Burghard Lipphardt,
Vladislav Gerginov,
Stefan Weyers
Abstract:
We describe an optical frequency stabilization scheme of a microwave oscillator that is used for the interrogation of primary caesium fountain clocks. Because of its superior phase noise properties, this scheme, which is based on an ultrastable laser and a femtosecond laser frequency comb, overcomes the frequency instability limitations of fountain clocks given by the previously utilized quartz-os…
▽ More
We describe an optical frequency stabilization scheme of a microwave oscillator that is used for the interrogation of primary caesium fountain clocks. Because of its superior phase noise properties, this scheme, which is based on an ultrastable laser and a femtosecond laser frequency comb, overcomes the frequency instability limitations of fountain clocks given by the previously utilized quartz-oscillator-based frequency synthesis. The presented scheme combines the transfer of the short-term frequency instability of an optical cavity and the long-term frequency instability of a hydrogen maser to the microwave oscillator and is designed to provide continuous long-term operation for extended measurement periods of several weeks. The utilization of the twofold stabilization scheme on the one hand ensures the referencing of the fountain frequency to the hydrogen maser frequency and on the other hand results in a phase noise level of the fountain interrogation signal, which enables fountain frequency instabilities at the $2.5 \times 10^{-14} (τ/\mathrm{s})^{-1/2}$ level which are quantum projection noise limited.
△ Less
Submitted 15 November, 2016; v1 submitted 19 September, 2016;
originally announced September 2016.
-
Loading of a fountain clock with an enhanced Low-Velocity Intense Source of atoms
Authors:
Georgi Dobrev,
Vladislav Gerginov,
Stefan Weyers
Abstract:
We present experimental work for improved atom loading in the optical molasses of a caesium fountain clock, employing a low-velocity intense source of atoms (LVIS) [Lu et al., Phys. Rev. Lett. 77, 3331 (1996)], which we modified by adding a "dark" state pump laser. With this modification the atom source has a mean flux of $4 \times 10^{8}$ atoms/s at a mean atom velocity of $8.6$ m/s. Compared to…
▽ More
We present experimental work for improved atom loading in the optical molasses of a caesium fountain clock, employing a low-velocity intense source of atoms (LVIS) [Lu et al., Phys. Rev. Lett. 77, 3331 (1996)], which we modified by adding a "dark" state pump laser. With this modification the atom source has a mean flux of $4 \times 10^{8}$ atoms/s at a mean atom velocity of $8.6$ m/s. Compared to fountain operation using background gas loading, we achieved a significant increase of the loaded and detected atom number by a factor of 40. Operating the fountain clock with a total number of detected atoms $N_{\mathrm{at}}=2.9 \times 10^6$ in the quantum projection noise-limited regime, a frequency instability $σ_y\left(1\text{s}\right)=2.7 \times 10^{-14}$ was demonstrated.
△ Less
Submitted 19 January, 2016;
originally announced January 2016.
-
Realization of a time-scale with an accurate optical lattice clock
Authors:
C. Grebing,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
V. Gerginov,
S. Weyers,
B. Lipphardt,
F. Riehle,
U. Sterr,
C. Lisdat
Abstract:
Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the re-definition of the SI base unit second as they now surpass the performance of caesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of the optical clocks that made a cont…
▽ More
Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the re-definition of the SI base unit second as they now surpass the performance of caesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of the optical clocks that made a continuous realization of a timescale impractical. In this paper, we demonstrate how this situation can be resolved and that a timescale based on an optical clock can be established that is superior to one based on even the best caesium fountain clocks. The paper also gives further proof of the international consistency of strontium lattice clocks on the $10^{-16}$ accuracy level, which is another prerequisite for a change in the definition of the second.
△ Less
Submitted 22 February, 2016; v1 submitted 12 November, 2015;
originally announced November 2015.
-
Phase Analysis for Frequency Standards in the Microwave and Optical Domains
Authors:
M. Kazda,
V. Gerginov,
N. Huntemann,
B. Lipphardt,
S. Weyers
Abstract:
Coherent manipulation of atomic states is a key concept in high-precision spectroscopy and used in atomic fountain clocks and a number of optical frequency standards. Operation of these standards can involve a number of cyclic switching processes, which may induce cycle synchronous phase excursions of the interrogation signal and thus lead to shifts in the output of the frequency standard. We have…
▽ More
Coherent manipulation of atomic states is a key concept in high-precision spectroscopy and used in atomic fountain clocks and a number of optical frequency standards. Operation of these standards can involve a number of cyclic switching processes, which may induce cycle synchronous phase excursions of the interrogation signal and thus lead to shifts in the output of the frequency standard. We have built a FPGA-based phase analyzer to investigate these effects and conducted measurements on two frequency standards. For the caesium fountain PTB-CSF2 we were able to exclude phase variations of the microwave source at the level of a few $μ$rad, corresponding to relative frequency shifts of less than 10$^{-16}$. In the optical domain, we investigated phase variations in PTB's Yb$^+$ optical frequency standard and made detailed measurements of AOM chirps and their scaling with duty cycle and driving power. We ascertained that cycle-synchronous as well as long-term phase excursion do not cause frequency shifts larger than 10$^{-18}$.
△ Less
Submitted 9 July, 2015;
originally announced July 2015.
-
Improved limit on a temporal variation of $m_p/m_e$ from comparisons of Yb$^+$ and Cs atomic clocks
Authors:
N. Huntemann,
B. Lipphardt,
Chr. Tamm,
V. Gerginov,
S. Weyers,
E. Peik
Abstract:
Accurate measurements of different transition frequencies between atomic levels of the electronic and hyperfine structure over time are used to investigate temporal variations of the fine structure constant $α$ and the proton-to-electron mass ratio $μ$. We measure the frequency of the $^2S_{1/2}\rightarrow {^2F_{7/2}}$ electric octupole (E3) transition in $^{171}$Yb$^+$ against two caesium fountai…
▽ More
Accurate measurements of different transition frequencies between atomic levels of the electronic and hyperfine structure over time are used to investigate temporal variations of the fine structure constant $α$ and the proton-to-electron mass ratio $μ$. We measure the frequency of the $^2S_{1/2}\rightarrow {^2F_{7/2}}$ electric octupole (E3) transition in $^{171}$Yb$^+$ against two caesium fountain clocks as $f(E3) = 642\,121\,496\,772\,645.36(25)$~Hz with an improved fractional uncertainty of $3.9\times 10^{-16}$. This transition frequency shows a strong sensitivity to changes of $α$. Together with a number of previous and recent measurements of the $^2S_{1/2}\rightarrow {^2D_{3/2}}$ electric quadrupole transition in $^{171}$Yb$^+$ and with data from other elements, a least-squares analysis yields $(1/α)(dα/dt)=-0.20(20)\times 10^{-16}/\mathrm{yr}$ and $(1/μ)(dμ/dt)=-0.5(1.6)\times 10^{-16}/\mathrm{yr}$, confirming a previous limit on $dα/dt$ and providing the most stringent limit on $d μ/dt$ from laboratory experiments.
△ Less
Submitted 16 July, 2014;
originally announced July 2014.
-
A strontium lattice clock with $3 \times 10^{-17}$ inaccuracy and its frequency
Authors:
Stephan Falke,
Nathan Lemke,
Christian Grebing,
Burghard Lipphardt,
Stefan Weyers,
Vladislav Gerginov,
Nils Huntemann,
Christian Hagemann,
Ali Al-Masoudi,
Sebastian Häfner,
Stefan Vogt,
Uwe Sterr,
Christian Lisdat
Abstract:
We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent ag…
▽ More
We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17}$, opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy, or optical clock evaluation.
△ Less
Submitted 15 August, 2014; v1 submitted 12 December, 2013;
originally announced December 2013.
-
A Cs-Based Optical Frequency Measurement Using Cross-Linked Optical and Microwave Oscillators
Authors:
Chr. Tamm,
N. Huntemann,
B. Lipphardt,
V. Gerginov,
N. Nemitz,
M. Kazda,
S. Weyers,
E. Peik
Abstract:
We describe a measurement of the frequency of the 2S1/2(F = 0) - 2D3/2(F' = 2) transition of 171Yb+ at the wavelength 436 nm (frequency 688 THz), using a single Yb+ ion confined in a Paul trap and two caesium fountains as references. In one of the fountains, the frequency of the microwave oscillator that interrogates the caesium atoms is stabilized by the laser that excites the Yb+ reference trans…
▽ More
We describe a measurement of the frequency of the 2S1/2(F = 0) - 2D3/2(F' = 2) transition of 171Yb+ at the wavelength 436 nm (frequency 688 THz), using a single Yb+ ion confined in a Paul trap and two caesium fountains as references. In one of the fountains, the frequency of the microwave oscillator that interrogates the caesium atoms is stabilized by the laser that excites the Yb+ reference transition with a linewidth in the hertz range. The stability is transferred to the microwave oscillator with the use of a fiber laser based optical frequency comb generator that also provides the frequency conversion for the absolute frequency measurement. The frequency comb generator is configured as a transfer oscillator so that fluctuations of the pulse repetition rate and of the carrier offset frequency do not degrade the stability of the frequency conversion. The phase noise level of the generated ultrastable microwave signal is comparable to that of a cryogenic sapphire oscillator. For fountain operation with optical molasses loaded from a laser cooled atomic beam source, we obtain a stability corresponding to a fractional Allan deviation of $4.1\times 10^{-14}\ (τ/\text{s})^{-1/2}$. With the molasses loaded from thermal vapor and an averaging time of 65 h, we measure the frequency of the Yb+ transition with a relative statistical uncertainty of $2.8\times10^{-16}$ and a systematic uncertainty of $5.9\times10^{-16}$. The frequency was also simultaneously measured with the second fountain that uses a quartz-based interrogation oscillator. The unperturbed frequency of the Yb+ transition is realized with an uncertainty of $1.1\times10^{-16}$ that mainly results from the uncertainty of the blackbody shift at the operating temperature near 300 K. The transition frequency of 688 358 979 309 307.82(36) Hz, measured with the two fountains, is in good agreement with previous results.
△ Less
Submitted 30 October, 2013;
originally announced October 2013.
-
Atomic trajectory characterization in a fountain clock based on the spectrum of a hyperfine transition
Authors:
Nils Nemitz,
Vladislav Gerginov,
Robert Wynands,
Stefan Weyers
Abstract:
We describe a new method to determine the position of the atomic cloud during its interaction with the microwave field in the cavity of a fountain clock. The positional information is extracted from the spectrum of the F=3,mF=0 to F=4,mF=-1 hyperfine transition, which shows a position dependent asymmetry when the magnetic C-field is tilted by a few degrees with respect to the cavity axis. Analysis…
▽ More
We describe a new method to determine the position of the atomic cloud during its interaction with the microwave field in the cavity of a fountain clock. The positional information is extracted from the spectrum of the F=3,mF=0 to F=4,mF=-1 hyperfine transition, which shows a position dependent asymmetry when the magnetic C-field is tilted by a few degrees with respect to the cavity axis. Analysis of this spectral asymmetry provides the horizontal center-of-mass position for the ensemble of atoms contributing to frequency measurements. With an uncertainty on the order of 0.1 mm, the obtained information is useful for putting limits on the systematic uncertainty due to distributed cavity phase gradients. The validity of the new method is demonstrated through experimental evidence.
△ Less
Submitted 14 February, 2012;
originally announced February 2012.
-
Distributed cavity phase frequency shifts of the caesium fountain PTB-CSF2
Authors:
S. Weyers,
V. Gerginov,
N. Nemitz,
R. Li,
K. Gibble
Abstract:
We evaluate the frequency error from distributed cavity phase in the caesium fountain clock PTB-CSF2 at the Physikalisch-Technische Bundesanstalt with a combination of frequency measurements and ab initio calculations. The associated uncertainty is 1.3E-16, with a frequency bias of 0.4E-16. The agreement between the measurements and calculations explains the previously observed frequency shifts at…
▽ More
We evaluate the frequency error from distributed cavity phase in the caesium fountain clock PTB-CSF2 at the Physikalisch-Technische Bundesanstalt with a combination of frequency measurements and ab initio calculations. The associated uncertainty is 1.3E-16, with a frequency bias of 0.4E-16. The agreement between the measurements and calculations explains the previously observed frequency shifts at elevated microwave amplitude. We also evaluate the frequency bias and uncertainty due to the microwave lensing of the atomic wavepackets. We report a total PTB-CSF2 systematic uncertainty of 4.1E-16.
△ Less
Submitted 12 October, 2011;
originally announced October 2011.
-
Femtosecond frequency comb measurement of absolute frequencies and hyperfine coupling constants in cesium vapor
Authors:
Jason E. Stalnaker,
Vela Mbele,
Vladislav Gerginov,
Tara M. Fortier,
Scott A. Diddams,
Leo Hollberg,
Carol E. Tanner
Abstract:
We report measurements of absolute transition frequencies and hyperfine coupling constants for the 8S_{1/2}, 9S_{1/2}, 7D_{3/2}, and 7D_{5/2} states in ^{133}Cs vapor. The stepwise excitation through either the 6P_{1/2} or 6P_{3/2} intermediate state is performed directly with broadband laser light from a stabilized femtosecond laser optical-frequency comb. The laser beam is split, counter-propa…
▽ More
We report measurements of absolute transition frequencies and hyperfine coupling constants for the 8S_{1/2}, 9S_{1/2}, 7D_{3/2}, and 7D_{5/2} states in ^{133}Cs vapor. The stepwise excitation through either the 6P_{1/2} or 6P_{3/2} intermediate state is performed directly with broadband laser light from a stabilized femtosecond laser optical-frequency comb. The laser beam is split, counter-propagated and focused into a room-temperature Cs vapor cell. The repetition rate of the frequency comb is scanned and we detect the fluorescence on the 7P_{1/2,3/2} -> 6S_{1/2} branches of the decay of the excited states. The excitations to the different states are isolated by the introduction of narrow-bandwidth interference filters in the laser beam paths. Using a nonlinear least-squares method we find measurements of transition frequencies and hyperfine coupling constants that are in agreement with other recent measurements for the 8S state and provide improvement by two orders of magnitude over previously published results for the 9S and 7D states.
△ Less
Submitted 18 January, 2010;
originally announced January 2010.
-
Observation of the Nuclear Magnetic Octupole Moment of 87Rb from Spectroscopic Measurements of Hyperfine Intervals
Authors:
Vladislav Gerginov,
Carol E. Tanner,
W. R. Johnson
Abstract:
The magnetic octupole moment of 87Rb is determined from hyperfine intervals in the 5p 2P[3/2] state measured by Ye et al. [Opt. Lett. 21, 1280 (1996)]. Hyperfine constants A = 84.7189(22) MHz, B = 12.4942(43) MHz, and C = -0.12(09) kHz are obtained from the published measurements. The existence of a significant value for C indicates the presence of a nuclear magnetic octupole moment Omega. Combi…
▽ More
The magnetic octupole moment of 87Rb is determined from hyperfine intervals in the 5p 2P[3/2] state measured by Ye et al. [Opt. Lett. 21, 1280 (1996)]. Hyperfine constants A = 84.7189(22) MHz, B = 12.4942(43) MHz, and C = -0.12(09) kHz are obtained from the published measurements. The existence of a significant value for C indicates the presence of a nuclear magnetic octupole moment Omega. Combining the hyperfine constants with atomic structure calculations, we obtain Omega = -0.58(39) (b muN). Second-order corrections arising from interaction with the nearby 5p 2P[1/2] state are found to be insignificant.
△ Less
Submitted 5 December, 2008; v1 submitted 31 October, 2008;
originally announced October 2008.