Shower Separation in Five Dimensions for Highly Granular Calorimeters using Machine Learning
Authors:
S. Lai,
J. Utehs,
A. Wilhahn,
M. C. Fouz,
O. Bach,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
D. Heuchel,
A. Irles,
K. Krüger,
J. Kvasnicka,
S. Lu,
C. Neubüser,
A. Provenza,
M. Reinecke,
F. Sefkow,
S. Schuwalow,
M. De Silva,
Y. Sudo,
H. L. Tran,
L. Liu,
R. Masuda
, et al. (26 additional authors not shown)
Abstract:
To achieve state-of-the-art jet energy resolution for Particle Flow, sophisticated energy clustering algorithms must be developed that can fully exploit available information to separate energy deposits from charged and neutral particles. Three published neural network-based shower separation models were applied to simulation and experimental data to measure the performance of the highly granular…
▽ More
To achieve state-of-the-art jet energy resolution for Particle Flow, sophisticated energy clustering algorithms must be developed that can fully exploit available information to separate energy deposits from charged and neutral particles. Three published neural network-based shower separation models were applied to simulation and experimental data to measure the performance of the highly granular CALICE Analogue Hadronic Calorimeter (AHCAL) technological prototype in distinguishing the energy deposited by a single charged and single neutral hadron for Particle Flow. The performance of models trained using only standard spatial and energy and charged track position information from an event was compared to models trained using timing information available from AHCAL, which is expected to improve sensitivity to shower development and, therefore, aid in clustering. Both simulation and experimental data were used to train and test the models and their performances were compared. The best-performing neural network achieved significantly superior event reconstruction when timing information was utilised in training for the case where the charged hadron had more energy than the neutral one, motivating temporally sensitive calorimeters. All models under test were observed to tend to allocate energy deposited by the more energetic of the two showers to the less energetic one. Similar shower reconstruction performance was observed for a model trained on simulation and applied to data and a model trained and applied to data.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
Software Compensation for Highly Granular Calorimeters using Machine Learning
Authors:
S. Lai,
J. Utehs,
A. Wilhahn,
O. Bach,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
D. Heuchel,
A. Irles,
K. Krüger,
J. Kvasnicka,
S. Lu,
C. Neubüser,
A. Provenza,
M. Reinecke,
F. Sefkow,
S. Schuwalow,
M. De Silva,
Y. Sudo,
H. L. Tran,
E. Buhmann,
E. Garutti,
S. Huck
, et al. (39 additional authors not shown)
Abstract:
A neural network for software compensation was developed for the highly granular CALICE Analogue Hadronic Calorimeter (AHCAL). The neural network uses spatial and temporal event information from the AHCAL and energy information, which is expected to improve sensitivity to shower development and the neutron fraction of the hadron shower. The neural network method produced a depth-dependent energy w…
▽ More
A neural network for software compensation was developed for the highly granular CALICE Analogue Hadronic Calorimeter (AHCAL). The neural network uses spatial and temporal event information from the AHCAL and energy information, which is expected to improve sensitivity to shower development and the neutron fraction of the hadron shower. The neural network method produced a depth-dependent energy weighting and a time-dependent threshold for enhancing energy deposits consistent with the timescale of evaporation neutrons. Additionally, it was observed to learn an energy-weighting indicative of longitudinal leakage correction. In addition, the method produced a linear detector response and outperformed a published control method regarding resolution for every particle energy studied.
△ Less
Submitted 7 March, 2024;
originally announced March 2024.
-
Experimental determination of axion signal power of dish antennas and dielectric haloscopes using the reciprocity approach
Authors:
J. Egge,
M. Ekmedžić,
A. Gardikiotis,
E. Garutti,
S. Heyminck,
C. Kasemann,
S. Knirck,
M. Kramer,
C. Krieger,
D. Leppla-Weber,
S. Martens,
E. Öz,
N. Salama,
A. Schmidt,
H. Wang,
G. Wieching
Abstract:
The reciprocity approach is a powerful method to determine the expected signal power of axion haloscopes in a model-independent way. Especially for open and broadband setups like the MADMAX dielectric haloscope the sensitivity to the axion field is difficult to calibrate since they do not allow discrete eigenmode analysis and are optically too large to fully simulate. The central idea of the recip…
▽ More
The reciprocity approach is a powerful method to determine the expected signal power of axion haloscopes in a model-independent way. Especially for open and broadband setups like the MADMAX dielectric haloscope the sensitivity to the axion field is difficult to calibrate since they do not allow discrete eigenmode analysis and are optically too large to fully simulate. The central idea of the reciprocity approach is to measure a reflection-induced test field in the setup instead of trying to simulate the axion-induced field. In this article, the reciprocity approach is used to determine the expected signal power of a dish antenna and a minimal dielectric haloscope directly from measurements. The results match expectations from simulation but also include important systematic effects that are too difficult to simulate. In particular, the effect of antenna standing waves and higher order mode perturbations can be quantified for the first time in a dielectric haloscope.
△ Less
Submitted 2 April, 2024; v1 submitted 22 November, 2023;
originally announced November 2023.
-
Investigation of high resistivity p-type FZ silicon diodes after 60Co γ-irradiation
Authors:
Chuan Liao,
Eckhart Fretwurst,
Erika Garutti,
Joern Schwandt,
Ioana Pintilie,
Anja Himmerlich,
Michael Moll,
Yana Gurimskaya,
Zheng Li
Abstract:
In this work, the effects of $^\text{60}$Co $γ$-ray irradiation on high resistivity $p$-type diodes have been investigated. The diodes were exposed to dose values of 0.1, 0.2, 1, and \SI{2}{\mega Gy}. Both macroscopic ($I$--$V$, $C$--$V$) and microscopic (Thermally Stimulated Current~(TSC)) measurements were conducted to characterize the radiation-induced changes. The investigated diodes were manu…
▽ More
In this work, the effects of $^\text{60}$Co $γ$-ray irradiation on high resistivity $p$-type diodes have been investigated. The diodes were exposed to dose values of 0.1, 0.2, 1, and \SI{2}{\mega Gy}. Both macroscopic ($I$--$V$, $C$--$V$) and microscopic (Thermally Stimulated Current~(TSC)) measurements were conducted to characterize the radiation-induced changes. The investigated diodes were manufactured on high resistivity $p$-type Float Zone (FZ) silicon and were further classified into two types based on the isolation technique between the pad and guard ring: $p$-stop and $p$-spray. After irradiation, the macroscopic results of current-voltage and capacitance-voltage measurements were obtained and compared with existing literature data. Additionally, the microscopic measurements focused on the development of the concentration of different radiation-induced defects, including the boron interstitial and oxygen interstitial (B$_\text{i}$O$_\text{i}$) complex, the carbon interstitial and oxygen interstitial C$_\text{i}$O$_\text{i}$ defect, the H40K, and the so-called I$_\text{P}^*$. To investigate the thermal stability of induced defects in the bulk, isochronal annealing studies were performed in the temperature range of \SI{80}{\celsius} to \SI{300}{\celsius}. These annealing processes were carried out on diodes irradiated with doses of 1 and \SI{2}{\mega Gy} and the corresponding TSC spectra were analysed. Furthermore, in order to investigate the unexpected results observed in the $C$-$V$ measurements after irradiation with high dose values, the surface conductance between the pad and guard ring was measured as a function of both dose and annealing temperature.
△ Less
Submitted 27 June, 2023;
originally announced June 2023.
-
Investigation of the Boron removal effect induced by 5.5 MeV electrons on highly doped EPI- and Cz-silicon
Authors:
Chuan Liao,
Eckhart Fretwurst,
Erika Garutti,
Joern Schwandt,
Leonid Makarenko,
Ioana Pintilie,
Lucian Dragos Filip,
Anja Himmerlich,
Michael Moll,
Yana Gurimskaya,
Zheng Li
Abstract:
This study focuses on the properties of the B$_\text{i}$O$_\text{i}$ (interstitial Boron~-~interstitial Oxygen) and C$_\text{i}$O$_\text{i}$ (interstitial Carbon~-~interstitial Oxygen) defect complexes by \SI{5.5}{\mega\electronvolt} electrons in low resistivity silicon. Two different types of diodes manufactured on p-type epitaxial and Czochralski silicon with a resistivity of about 10~$Ω\cdot$cm…
▽ More
This study focuses on the properties of the B$_\text{i}$O$_\text{i}$ (interstitial Boron~-~interstitial Oxygen) and C$_\text{i}$O$_\text{i}$ (interstitial Carbon~-~interstitial Oxygen) defect complexes by \SI{5.5}{\mega\electronvolt} electrons in low resistivity silicon. Two different types of diodes manufactured on p-type epitaxial and Czochralski silicon with a resistivity of about 10~$Ω\cdot$cm were irradiated with fluence values between \SI{1e15}{\per\square\centi\meter} and \SI{6e15}{\per\square\centi\meter}. Such diodes cannot be fully depleted and thus the accurate evaluation of defect concentrations and properties (activation energy, capture cross-section, concentration) from Thermally Stimulated Currents (TSC) experiments alone is not possible. In this study we demonstrate that by performing Thermally Stimulated Capacitance (TS-Cap) experiments in similar conditions to TSC measurements and develo** theoretical models for simulating both types of B$_\text{i}$O$_\text{i}$ signals generated in TSC and TS-Cap measurements, accurate evaluations can be performed. The changes of the position-dependent electric field, the effective space charge density $N_\text{eff}$ profile as well as the occupation of the B$_\text{i}$O$_\text{i}$ defect during the electric field dependent electron emission, are simulated as a function of temperature. The macroscopic properties (leakage current and $N_\text{eff}$) extracted from current-voltage and capacitance-voltage measurements at \SI{20}{\celsius} are also presented and discussed
△ Less
Submitted 26 June, 2023;
originally announced June 2023.
-
Qualification of piezo-electric actuators for the MADMAX booster system at cryogenic temperatures and high magnetic fields
Authors:
E. Garutti,
H. Janssen,
D. Kreikemeyer-Lorenzo,
C. Krieger,
A. Lindner,
B. Majorovits,
J. Schaffran,
B. van Bree
Abstract:
We report on the qualification of a piezo-based linear stage for the manipulation of positions of dielectric discs in the booster of the MADMAX axion dark matter search experiment. A first demonstrator of the piezo drives, specifically developed for MADMAX, was tested at room temperature as well as at cryogenic temperatures down to 4.5 K and inside strong magnetic fields up to 5.3 T. These qualifi…
▽ More
We report on the qualification of a piezo-based linear stage for the manipulation of positions of dielectric discs in the booster of the MADMAX axion dark matter search experiment. A first demonstrator of the piezo drives, specifically developed for MADMAX, was tested at room temperature as well as at cryogenic temperatures down to 4.5 K and inside strong magnetic fields up to 5.3 T. These qualification measurements prove that the piezo-based linear stage is suited for MADMAX and fulfills the requirements.
△ Less
Submitted 7 July, 2023; v1 submitted 22 May, 2023;
originally announced May 2023.
-
SiPM Signal Processing via Multiple Linear Regression
Authors:
Wolfgang Schmailzl,
Claudio Piemonte,
Erika Garutti,
Walter Hansch
Abstract:
This paper presents a novel approach using multiple linear regression to process transient signals from silicon photomultipliers. The method provides excellent noise suppression and pulse detection in scenarios with a high pulse count rate and superimposed pulses. Insights into its implementation and benchmark results are presented. We also show how this approach can be used to automatically detec…
▽ More
This paper presents a novel approach using multiple linear regression to process transient signals from silicon photomultipliers. The method provides excellent noise suppression and pulse detection in scenarios with a high pulse count rate and superimposed pulses. Insights into its implementation and benchmark results are presented. We also show how this approach can be used to automatically detect the pulse shape from a given transient signal, providing good detection for count rates up to 90MHz. Experimental data are used to present an application where this algorithm improves charge spectrum resolution by an order of magnitude.
△ Less
Submitted 24 April, 2023;
originally announced April 2023.
-
PeakOTron: A Python Module for Fitting Charge Spectra of Silicon Photomultipliers
Authors:
Jack Rolph,
Erika Garutti,
Robert Klanner,
Tobias Quadfasel,
Joern Schwandt
Abstract:
A Python program has been developed which fits a published detector-response model to SiPM charge spectra to characterise SiPMs. Spectra for SiPMs illuminated by low intensity pulsed light with Poisson-distributed number of photons and a time spread of order nanoseconds or less, can be analysed. The entire charge spectra, including the intervals in-between the photoelectron peaks, are fitted, whic…
▽ More
A Python program has been developed which fits a published detector-response model to SiPM charge spectra to characterise SiPMs. Spectra for SiPMs illuminated by low intensity pulsed light with Poisson-distributed number of photons and a time spread of order nanoseconds or less, can be analysed. The entire charge spectra, including the intervals in-between the photoelectron peaks, are fitted, which allows determining, in addition to the mean number of detected photons, gain, gain spread, prompt cross-talk, pedestal, and electronics noise, the dark-count rate as well as the probability and time constant of after-pulses. The starting values of the fit parameters are extracted from the charge spectra.
The program performance has been evaluated using simulated charge spectra with the different SiPM parameters varied in a wide range. By analysing 100 simulated spectra for every parameter set, the biases and statistical uncertainties of the individual parameters have been determined. It is found that the parameters are precisely determined and that the entire spectra are well described, in most cases with a $χ^2$/NDF close to 1. In addition, measured spectra for two types of SiPMs for a wide range of over-voltages have been analysed. The program achieves mostly a good description of the spectra, and the parameters determined agree with the values from the producers and expectations.
The program can be used for detailed analyses of single spectra, but, as it is compatible with the native \texttt{Python} multiprocessing module, also for the automatic characterisation of large samples of SiPMs.
△ Less
Submitted 27 January, 2023;
originally announced January 2023.
-
Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
J. P. Figueiredo de sa Sousa de Almeida,
P. G. Dias de Almeida,
A. Alpana,
M. Alyari,
I. Andreev,
U. Aras,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Banerjee,
P. DeBarbaro,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (435 additional authors not shown)
Abstract:
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing med…
▽ More
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.
△ Less
Submitted 27 May, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Study of depth-dependent charge collection profiles in irradiated pad diodes
Authors:
Mohammadtaghi Hajheidari,
Massimiliano Antonello,
Erika Garutti,
Robert Klanner,
Joern Schwandt,
Georg Steinbrueck
Abstract:
In this work, charge collection profiles of non-irradiated and irradiated 150 $μ$m $p$-type pad diodes were measured using a 5.2 GeV electron beam traversing the diode parallel to the readout electrode. Four diodes were irradiated to 1 MeV neutron equivalent fluences of 2, 4, 8, and 12E15 {cm}^{-2} with 23 MeV protons. The Charge Collection Efficiency profiles as a function of depth are extracted…
▽ More
In this work, charge collection profiles of non-irradiated and irradiated 150 $μ$m $p$-type pad diodes were measured using a 5.2 GeV electron beam traversing the diode parallel to the readout electrode. Four diodes were irradiated to 1 MeV neutron equivalent fluences of 2, 4, 8, and 12E15 {cm}^{-2} with 23 MeV protons. The Charge Collection Efficiency profiles as a function of depth are extracted by unfolding the data. The results of the measurements are compared to the simulation using three radiation damage models from literature which were tuned to different irradiation types and fluences.
△ Less
Submitted 23 January, 2023; v1 submitted 26 September, 2022;
originally announced September 2022.
-
Radiation Hardness of a Wide Spectral Range SiPM with Quasi-Spherical Junction
Authors:
Julius Römer,
Erika Garutti,
Wolfgang Schmailzl,
Jörn Schwandt,
Stephan Martens
Abstract:
New pixel geometries are on the rise to achieve high sensitivity in near-infrared wavelengths with silicon photomultipliers (SiPMs). We test prototypes of the tip avalanche photo-diodes, which feature a quasi-spherical p-n junction and a high photodetection efficiency over a wide spectral range, and analyze the performance after neutron irradiation. The observed increase in dark count rate is sign…
▽ More
New pixel geometries are on the rise to achieve high sensitivity in near-infrared wavelengths with silicon photomultipliers (SiPMs). We test prototypes of the tip avalanche photo-diodes, which feature a quasi-spherical p-n junction and a high photodetection efficiency over a wide spectral range, and analyze the performance after neutron irradiation. The observed increase in dark count rate is significantly smaller than for a SiPM with a conventional design, indicating a good radiation hardness of the pixel geometry.
△ Less
Submitted 16 September, 2022;
originally announced September 2022.
-
Self-heating Effect in Silicon-Photomultipliers
Authors:
E. Garutti,
R. Klanner,
E. Popova,
S. Martens,
J. Schwandt,
C. Villalba
Abstract:
The main effect of radiation damage in a Silicon-Photolumtiplier (SiPM) is a dramatic increase in the dark current. The power dissipated, if not properly cooled, heats the SiPM, whose performance parameters depend on temperature. Heating studies were performed with a KETEK SiPM, glued on an Al$_2$O$_3$ substrate, which is either directly connected to the temperature-controlled chuck of a probe sta…
▽ More
The main effect of radiation damage in a Silicon-Photolumtiplier (SiPM) is a dramatic increase in the dark current. The power dissipated, if not properly cooled, heats the SiPM, whose performance parameters depend on temperature. Heating studies were performed with a KETEK SiPM, glued on an Al$_2$O$_3$ substrate, which is either directly connected to the temperature-controlled chuck of a probe station, or through layers of material with well-known thermal resistance. The SiPM is illuminated by a LED operated in DC-mode. The SiPM current is measured and used to determine the steady-state temperature as a function of power dissipated in the multiplication region of the SiPM and thermal resistance, as well as the time dependencies for heating and cooling. This information can be used to correct the parameters determined for radiation-damaged SiPM for the effects of self-heating. The method can also be employed for packaged SiPMs with unknown thermal contact to a heat sink. The results presented in this paper are preliminary.
△ Less
Submitted 14 June, 2022; v1 submitted 11 May, 2022;
originally announced May 2022.
-
Radiation damage uniformity in a SiPM
Authors:
O. Bychkova,
E. Garutti,
E. Popova,
A. Stifutkin,
S. Martens,
P. Parygin,
A. Kaminsky,
J. Schwandt
Abstract:
A dedicated single-cell SiPM structure is designed and measured to investigate the radiation damage effects on the gain and breakdown voltage of SiPMs exposed to a reactor neutron fluence up to $Φ$ = 5e13 cm$^{-2}$. The cell has a pitch of 15 $μ$m. Results of the measurements and analysis of the IV-curves are presented. Impact of the self-heating effect was investigated. The radiation damage unifo…
▽ More
A dedicated single-cell SiPM structure is designed and measured to investigate the radiation damage effects on the gain and breakdown voltage of SiPMs exposed to a reactor neutron fluence up to $Φ$ = 5e13 cm$^{-2}$. The cell has a pitch of 15 $μ$m. Results of the measurements and analysis of the IV-curves are presented. Impact of the self-heating effect was investigated. The radiation damage uniformity of 1 cell and 120 cells was checked up to $U_\mathit{ov}$ = 1.7 V. Fluence dependence of the breakdown voltage from the current measurements $U^{IV}_\mathit{bd}$ was extracted and compared to that of the breakdown voltage from the gain measurements $U^{G}_\mathit{bd}$.
△ Less
Submitted 2 May, 2022;
originally announced May 2022.
-
Radiation hardness study using SiPMs with single-cell readout
Authors:
E. Garutti,
E. Popova,
P. Parygin,
O. Bychkova,
A. Kaminsky,
S. Martens,
J. Schwandt,
A. Stifutkin
Abstract:
A dedicated single-cell SiPM structure is designed and measured to investigate the radiation damage effects on the gain and turn-off voltage of SiPMs exposed to a reactor neutron fluence up to $Φ$ = 5e13 cm$^{-2}$. The cell has a pitch of 15 $μ$m. The fluence dependence of gain and turn-off voltage are reported. A reduction of the gain by 19% and an increase of $V_{off}$ by $\approx$0.5 V is obser…
▽ More
A dedicated single-cell SiPM structure is designed and measured to investigate the radiation damage effects on the gain and turn-off voltage of SiPMs exposed to a reactor neutron fluence up to $Φ$ = 5e13 cm$^{-2}$. The cell has a pitch of 15 $μ$m. The fluence dependence of gain and turn-off voltage are reported. A reduction of the gain by 19% and an increase of $V_{off}$ by $\approx$0.5 V is observed after $Φ$ = 5e13 cm$^{-2}$.
△ Less
Submitted 31 October, 2021;
originally announced November 2021.
-
Depth-dependent charge collection profile of pad diodes
Authors:
Mohammadtaghi Hajheidari,
Erika Garutti,
Joern Schwandt,
Aliakbar Ebrahimi
Abstract:
The collected charge of two pad diodes is measured along the diode width using a 5:2 GeV electron beam at the DESY II beam test facility. The electron beam enters parallel to the readout electrode plane and perpendicular to the edge of the diode. The position of the electron beam is reconstructed by three planes of an EUDET-type telescope. An in-situ procedure is developed to align the diode surfa…
▽ More
The collected charge of two pad diodes is measured along the diode width using a 5:2 GeV electron beam at the DESY II beam test facility. The electron beam enters parallel to the readout electrode plane and perpendicular to the edge of the diode. The position of the electron beam is reconstructed by three planes of an EUDET-type telescope. An in-situ procedure is developed to align the diode surface parallel to the electron beam. The result of these measurements is the charge collection efficiency profile as a function of depth for each diode. For a non-irradiated diode, the charge profile is uniform as a function of the beam position for bias voltages above the full-depletion, as expected. For the irradiated diode, the charge profile is non-uniform and changes as a function of bias voltage.
△ Less
Submitted 15 December, 2021; v1 submitted 7 August, 2021;
originally announced August 2021.
-
Position reconstruction for segmented detectors
Authors:
A. Ebrahimi,
F. Feind,
E. Fretwurst,
E. Garutti,
M. Hajheidari,
R. Klanner,
D. Pitzl,
J. Schwandt,
G. Steinbrueck,
I. Zoi
Abstract:
The topic of the paper is the position reconstruction from signals of segmented detectors. With the help of a simple simulation, it is shown that the position reconstruction using the centre-of-gravity method is strongly biased, if the width of the charge (or e.g. light) distribution at the electrodes (or photo detectors) is less than the read-out pitch. A method is proposed which removes this bia…
▽ More
The topic of the paper is the position reconstruction from signals of segmented detectors. With the help of a simple simulation, it is shown that the position reconstruction using the centre-of-gravity method is strongly biased, if the width of the charge (or e.g. light) distribution at the electrodes (or photo detectors) is less than the read-out pitch. A method is proposed which removes this bias for events with signals in two or more read-out channels and thereby improves the position resolution. The method also provides an estimate of the position-response function for every event. Examples are given for which its width as a function of the reconstructed position varies by as much as an order of magnitude.
A fast Monte Carlo program is described which simulates the signals from a silicon pixel detector traversed by charged particles under different angles, and the results obtained with the proposed reconstruction method and with the centre-of-gravity method are compared. The simulation includes the local energy-loss fluctuations, the position-dependent electric field, the diffusion of the charge carriers, the electronics noise and charge thresholds for clustering. A comparison to test-beam-data is used to validate the simulation.
△ Less
Submitted 14 July, 2021;
originally announced July 2021.
-
Position resolution with 25 um pitch pixel sensors before and after irradiation
Authors:
I. Zoi,
A. Ebrahimi,
F. Feindt,
E. Garutti,
P. Gunnellini,
A. Hinzmann,
C. Niemeyer,
D. Pitzl,
J. Schwandt,
G. Steinbrück
Abstract:
Pixelated silicon detectors are state-of-the-art technology to achieve precise tracking and vertexing at collider experiments, designed to accurately measure the hit position of incoming particles in high rate and radiation environments. The detector requirements become extremely demanding for operation at the High-Luminosity LHC, where up to 200 interactions will overlap in the same bunch crossin…
▽ More
Pixelated silicon detectors are state-of-the-art technology to achieve precise tracking and vertexing at collider experiments, designed to accurately measure the hit position of incoming particles in high rate and radiation environments. The detector requirements become extremely demanding for operation at the High-Luminosity LHC, where up to 200 interactions will overlap in the same bunch crossing on top of the process of interest. Additionally, fluences up to 2.3 10^16 cm^-2 1 MeV neutron equivalent at 3.0 cm distance from the beam are expected for an integrated luminosity of 3000 fb^-1. In the last decades, the pixel pitch has constantly been reduced to cope with the experiment's needs of achieving higher position resolution and maintaining low pixel occupancy per channel. The spatial resolution improves with a decreased pixel size but it degrades with radiation damage. Therefore, prototype sensor modules for the upgrade of the experiments at the HL-LHC need to be tested after being irradiated. This paper describes position resolution measurements on planar prototype sensors with 100x25 um^2 pixels for the CMS Phase-2 Upgrade. It reviews the dependence of the position resolution on the relative inclination angle between the incoming particle trajectory and the sensor, the charge threshold applied by the readout chip, and the bias voltage. A precision setup with three parallel planes of sensors has been used to investigate the performance of sensors irradiated to fluences up to F_eq = 3.6 10^15 cm-2. The measurements were performed with a 5 GeV electron beam. A spatial resolution of 3.2 +\- 0.1 um is found for non-irradiated sensors, at the optimal angle for charge sharing. The resolution is 5.0 +/- 0.2 um for a proton-irradiated sensor at F_eq = 2.1 10^15 cm-2 and a neutron-irradiated sensor at F_eq = 3.6 10^15 cm^-2.
△ Less
Submitted 9 July, 2021;
originally announced July 2021.
-
Simulating MADMAX in 3D: Requirements for Dielectric Axion Haloscopes
Authors:
S. Knirck,
J. Schütte-Engel,
S. Beurthey,
D. Breitmoser,
A. Caldwell,
C. Diaconu,
J. Diehl,
J. Egge,
M. Esposito,
A. Gardikiotis,
E. Garutti,
S. Heyminck,
F. Hubaut,
J. Jochum,
P. Karst,
M. Kramer,
C. Krieger,
D. Labat,
C. Lee,
X. Li,
A. Lindner,
B. Majorovits,
S. Martens,
M. Matysek,
E. Öz
, et al. (16 additional authors not shown)
Abstract:
We present 3D calculations for dielectric haloscopes such as the currently envisioned MADMAX experiment. For ideal systems with perfectly flat, parallel and isotropic dielectric disks of finite diameter, we find that a geometrical form factor reduces the emitted power by up to $30\,\%$ compared to earlier 1D calculations. We derive the emitted beam shape, which is important for antenna design. We…
▽ More
We present 3D calculations for dielectric haloscopes such as the currently envisioned MADMAX experiment. For ideal systems with perfectly flat, parallel and isotropic dielectric disks of finite diameter, we find that a geometrical form factor reduces the emitted power by up to $30\,\%$ compared to earlier 1D calculations. We derive the emitted beam shape, which is important for antenna design. We show that realistic dark matter axion velocities of $10^{-3} c$ and inhomogeneities of the external magnetic field at the scale of $10\,\%$ have negligible impact on the sensitivity of MADMAX. We investigate design requirements for which the emitted power changes by less than $20\,\%$ for a benchmark boost factor with a bandwidth of $50\,{\rm MHz}$ at $22\,{\rm GHz}$, corresponding to an axion mass of $90\,μ{\rm eV}$. We find that the maximum allowed disk tilt is $100\,μ{\rm m}$ divided by the disk diameter, the required disk planarity is $20\,μ{\rm m}$ (min-to-max) or better, and the maximum allowed surface roughness is $100\,μ{\rm m}$ (min-to-max). We show how using tiled dielectric disks glued together from multiple smaller patches can affect the beam shape and antenna coupling.
△ Less
Submitted 13 October, 2021; v1 submitted 13 April, 2021;
originally announced April 2021.
-
A computer program to simulate the response of SiPMs
Authors:
E. Garutti,
R. Klanner,
J. Rolph,
J. Schwandt
Abstract:
A Monte Carlo program which simulates the response of SiPMs is presented. Input to the program are the mean number and the time distribution of Geiger discharges from light, as well as the dark-count rate. For every primary Geiger discharge from light and dark counts in an event, correlated Geiger discharges due to prompt and delayed cross-talk and after-pulses are simulated, and a table of the am…
▽ More
A Monte Carlo program which simulates the response of SiPMs is presented. Input to the program are the mean number and the time distribution of Geiger discharges from light, as well as the dark-count rate. For every primary Geiger discharge from light and dark counts in an event, correlated Geiger discharges due to prompt and delayed cross-talk and after-pulses are simulated, and a table of the amplitudes and times of all Geiger discharges in a specified time window generated.
A number of different physics-based models and statistical treatments for the simulation of correlated Geiger discharges can be selected. These lists for many events together with different options for the pulse shapes of single Geiger discharges are used to simulate charge spectra, as measured by a current-integrating charge-to-digital converter, or current transients convolved with an electronics response function, as recorded by a digital oscilloscope. The program can be used to compare simulations with different assumptions to experimental data, and thus find out which models are most appropriate for a given SiPM, optimise the operating conditions and readout for a given application or test programs which are used to extract SiPM parameters from experimental data.
△ Less
Submitted 19 June, 2020;
originally announced June 2020.
-
MADMAX Status Report
Authors:
S. Beurthey,
N. Böhmer,
P. Brun,
A. Caldwell,
L. Chevalier,
C. Diaconu,
G. Dvali,
P. Freire,
E. Garutti,
C. Gooch,
A. Hambarzumjan,
S. Heyminck,
F. Hubaut,
J. Jochum,
P. Karst,
S. Khan,
D. Kittlinger,
S. Knirck,
M. Kramer,
C. Krieger,
T. Lasserre,
C. Lee,
X. Li,
A. Lindner,
B. Majorovits
, et al. (20 additional authors not shown)
Abstract:
In this report we present the status of the MAgnetized Disk and Mirror Axion eXperiment (MADMAX), the first dielectric haloscope for the direct search of dark matter axions in the mass range of 40 to 400 $μ$eV. MADMAX will consist of several parallel dielectric disks, which are placed in a strong magnetic field and with adjustable separations. This setting is expected to allow for an observable em…
▽ More
In this report we present the status of the MAgnetized Disk and Mirror Axion eXperiment (MADMAX), the first dielectric haloscope for the direct search of dark matter axions in the mass range of 40 to 400 $μ$eV. MADMAX will consist of several parallel dielectric disks, which are placed in a strong magnetic field and with adjustable separations. This setting is expected to allow for an observable emission of axion induced electromagnetic waves at a frequency between 10 and 100 GHz corresponding to the axion mass. The present document orignated from a status report to the DESY PRC in 2019.
△ Less
Submitted 28 October, 2020; v1 submitted 24 March, 2020;
originally announced March 2020.
-
A new model for the TCAD simulation of the silicon damage by high fluence proton irradiation
Authors:
Joern Schwandt,
Eckhart Fretwurst,
Erika Garutti,
Robert Klanner,
Christian Scharf,
Georg Steinbrueck
Abstract:
For the high-luminosity phase of the Large Hadron Collider (HL-LHC), at the expected position of the innermost pixel detector layer of the CMS and ATLAS experiments, the estimated equivalent neutron fluence after 3000 fb$^{-1}$ is 2$\cdot$10$^{16}$ n$_{eq}$/cm$^2$, and the IEL (Ionizing Energy Loss) dose in the SiO$_2$ 12 MGy. The optimisation of the pixel sensors and the understanding of their pe…
▽ More
For the high-luminosity phase of the Large Hadron Collider (HL-LHC), at the expected position of the innermost pixel detector layer of the CMS and ATLAS experiments, the estimated equivalent neutron fluence after 3000 fb$^{-1}$ is 2$\cdot$10$^{16}$ n$_{eq}$/cm$^2$, and the IEL (Ionizing Energy Loss) dose in the SiO$_2$ 12 MGy. The optimisation of the pixel sensors and the understanding of their performance as a function of fluence and dose makes a radiation damage model for TCAD simulations, which describes the available experimental data, highly desirable. The currently available bulk-damage models are not able to describe simultaneously the measurements of dark current (I-V), capacitance-voltage (C-V) and charge collection efficiency (CCE) of pad diodes for fluences $\ge 1\cdot 10^{15}$ n$_{eq}$/cm$^2$. Therefore, for the development and validation of a new accurate bulk damage model we use I-V, C-V and CCE measurements on pad diodes available within the CMS-HPK campaign and data from samples irradiated recently with 24 GeV/c protons. For the determination of the radiation-induced damage parameters we utilise the "optimiser" of Synopsys TCAD, which allows the minimisation of the difference between the measured and simulated I-V, C-V and CCE. The outcome of this optimisation, the Hamburg Penta Trap Model (HPTM), provides a consistent and accurate description of the measurements of diodes irradiated with protons in the fluence range from 3$\cdot$10$^{14}$ n$_{eq}$/cm$^2$ to 1.3$\cdot$10$^{16}$ n$_{eq}$/cm$^2$.
△ Less
Submitted 23 April, 2019;
originally announced April 2019.
-
Analysis methods for highly radiation-damaged SiPMs
Authors:
S. Cerioli,
E. Garutti,
R. Klanner,
S. Martens,
J. Schwandt,
M. Zvolsky
Abstract:
Prototype SiPMs with 4384 pixels of dimensions $15 \times 15~μ$m$^2$ produced by KETEK have been irradiated with reactor neutrons to eight fluences between $10^9$ and $5\times 10^{14}$ cm$^{-2}$. For temperatures between $-30~^\circ $C and $+30~^\circ $C capacitance-voltage, admittance-frequency, current-forward voltage, current-reverse voltage and charge-voltage measurements with and without illu…
▽ More
Prototype SiPMs with 4384 pixels of dimensions $15 \times 15~μ$m$^2$ produced by KETEK have been irradiated with reactor neutrons to eight fluences between $10^9$ and $5\times 10^{14}$ cm$^{-2}$. For temperatures between $-30~^\circ $C and $+30~^\circ $C capacitance-voltage, admittance-frequency, current-forward voltage, current-reverse voltage and charge-voltage measurements with and without illumination by a sub-nanosecond laser have been performed. The data have been analysed using different methods in order to extract the dependence on neutron fluence and temperature of the electrical parameters, the breakdown oltage, the activation energy for the current generation, the dark-count rate and the response to light pulses. The results from the different analysis methods are compared.
△ Less
Submitted 15 April, 2019;
originally announced April 2019.
-
Characterisation of different stages of hadronic showers using the CALICE Si-W ECAL physics prototype
Authors:
CALICE Collaboration,
G. Eigen,
T. Price,
N. K. Watson,
A. Winter,
Y. Do,
A. Khan,
D. Kim,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
J. Apostolakis,
J. Giraud,
D. Grondin,
J. -Y. Hostachy,
O. Bach,
V. Bocharnikov,
E. Brianne
, et al. (81 additional authors not shown)
Abstract:
A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorith…
▽ More
A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorithm that reconstructs tracks within hadronic showers in a calorimeter in the absence of a magnetic field. The principle of carrying out detector monitoring and calibration using secondary tracks is also demonstrated.
△ Less
Submitted 18 September, 2019; v1 submitted 16 February, 2019;
originally announced February 2019.
-
Analysis of Testbeam Data of the Highly Granular RPC-Steel CALICE Digital Hadron Calorimeter and Validation of Geant4 Monte Carlo Models
Authors:
CALICE Collaboration,
M. Chefdeville,
J. Repond,
J. Schlereth,
J. R. Smith,
D. Trojand,
L. Xia,
Q. Zhang,
J. Apostolakis,
C. Grefe,
V. Ivantchenko,
G. Folger,
A. Ribon,
V. Uzhinskiy,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
O. Bach,
V. Bocharnikov,
E. Brianne,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
D. Heuchel
, et al. (71 additional authors not shown)
Abstract:
We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of…
▽ More
We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of $1\,\times\,1\,$cm$^{2}$ and a longitudinal segmentation of 38 layers, the calorimeter counted 350,208 readout channels, each read out with single-bit resolution (digital readout). The data were recorded in the Fermilab test beam in 2010-11. The analysis includes measurements of the calorimeter response and the energy resolution to positrons and muons, as well as detailed studies of various shower shape quantities. The results are compared to simulations based on Geant4, which utilise different electromagnetic and hadronic physics lists.
△ Less
Submitted 25 January, 2019;
originally announced January 2019.
-
A new experimental approach to probe QCD axion dark matter in the mass range above 40$μ$eV
Authors:
The MADMAX Collaboration,
P. Brun,
A. Caldwell,
L. Chevalier,
G. Dvali,
P. Freire,
E. Garutti,
S. Heyminck,
J. Jochum,
S. Knirck,
M. Kramer,
C. Krieger,
T. Lasserre,
C. Lee,
X. Li,
A. Lindner,
B. Majorovits,
S. Martens,
M. Matysek,
A. Millar,
G. Raffelt,
J. Redondo,
O. Reimann,
A. Ringwald,
K. Saikawa
, et al. (6 additional authors not shown)
Abstract:
The axion emerges in extensions of the Standard Model that explain the absence of CP violation in the strong interactions. Simultaneously, it can provide naturally the cold dark matter in our universe. Several searches for axions and axion-like particles (ALPs) have constrained the corresponding parameter space over the last decades but no unambiguous hints of their existence have been found. The…
▽ More
The axion emerges in extensions of the Standard Model that explain the absence of CP violation in the strong interactions. Simultaneously, it can provide naturally the cold dark matter in our universe. Several searches for axions and axion-like particles (ALPs) have constrained the corresponding parameter space over the last decades but no unambiguous hints of their existence have been found. The axion mass range below 1 meV remains highly attractive and a well motivated region for dark matter axions. In this White Paper we present a description of a new experiment based on the concept of a dielectric haloscope for the direct search of dark matter axions in the mass range of 40 to 400 $μ$eV. This MAgnetized Disk and Mirror Axion eXperiment (MADMAX) will consist of several parallel dielectric disks, which are placed in a strong magnetic field and with adjustable separations. This setting is expected to allow for an observable emission of axion induced electromagnetic waves at a frequency between 10 to 100 GHz corresponding to the axion mass.
△ Less
Submitted 28 October, 2020; v1 submitted 22 January, 2019;
originally announced January 2019.
-
Radiation damage of SiPMs
Authors:
E. Garutti,
Yu. Musienko
Abstract:
The current understanding of radiation tollerance of Silicon Photomultipliers (SiPMs) is reviewd. Radiation damage in silicon sensors is briefly introduced, surface and bulk effects are separately addressed. Results on the operation of irradiated SiPMs with X-ray, gamma, electron, proton and neutron sources are presented. The most critical effect of radiation on SiPMs is the increase of dark count…
▽ More
The current understanding of radiation tollerance of Silicon Photomultipliers (SiPMs) is reviewd. Radiation damage in silicon sensors is briefly introduced, surface and bulk effects are separately addressed. Results on the operation of irradiated SiPMs with X-ray, gamma, electron, proton and neutron sources are presented. The most critical effect of radiation on SiPMs is the increase of dark count rate, which makes it impossible to resolve signals generated by a single photon from the noise. Methods to characterize irradiated SiPMs after their single photo-electron resolution is lost are discussed. Due to the important similarity in the operation below the breakdown voltage, also older studies on radiadion damage of avalange photodiodes (APD) are reviewed. Finally, ideas are presented on how to approach the development of radiation hard SiPMs in the future.
△ Less
Submitted 25 September, 2018; v1 submitted 14 September, 2018;
originally announced September 2018.
-
Hadronic Energy Resolution of a Combined High Granularity Scintillator Calorimeter System
Authors:
CALICE Collaboration,
J. Repond,
L. Xia,
J. Apostolakis,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
D. Boumediene,
V. Francais,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
O. Bach,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Gttlicher,
O. Hartbrich F. Krivan,
K. Krüger,
J. Kvasnicka,
S. Lu,
C. Neubüser,
A. Provenza
, et al. (84 additional authors not shown)
Abstract:
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles.…
▽ More
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles. The results of a software compensation technique based on weighting according to hit energy are compared to those of a standard linear energy reconstruction. The results are compared to predictions of the GEANT4 physics lists QGSP_BERT_HP and FTFP_BERT_HP.
△ Less
Submitted 12 September, 2018; v1 submitted 11 September, 2018;
originally announced September 2018.
-
Study of point- and cluster-defects in radiation-damaged silicon
Authors:
Elena M. Donegani,
Eckhart Fretwurst,
Erika Garutti,
Robert Klanner,
Gunnar Lindstroem,
Ioana Pintilie,
Roxana Radu,
Joern Schwandt
Abstract:
Non-ionising energy loss of radiation produces point defects and defect clusters in silicon, which result in a signifcant degradation of sensor performance. In this contribution results from TSC (Thermally Stimulated Current) defect spectroscopy for silicon pad diodes irradiated by electrons to fluences of a few $10^{14}$ cm$^{-2}$ and energies between 3.5 and 27 MeV for isochronal annealing betwe…
▽ More
Non-ionising energy loss of radiation produces point defects and defect clusters in silicon, which result in a signifcant degradation of sensor performance. In this contribution results from TSC (Thermally Stimulated Current) defect spectroscopy for silicon pad diodes irradiated by electrons to fluences of a few $10^{14}$ cm$^{-2}$ and energies between 3.5 and 27 MeV for isochronal annealing between 80 and 280°C, are presented. A method based on SRH (Shockley-Read-Hall) statistics is introduced, which assumes that the ionisation energy of the defects in a cluster depends on the fraction of occupied traps. The dfference of ionisation energy of an isolated point defect and a fully occupied cluster, $ΔE_a$, is extracted from the TSC data.
For the VOi (vacancy-oxygen interstitial) defect $ΔE_a = 0$ is found, which cofirms that it is a point defect, and validates the method for point defects. For clusters made of deep acceptors the $ΔE_a$ values for different defects are determined after annealing at 80°C as a function of electron energy, and for the irradiation with 15 MeV electrons as a function of annealing temperature. For the irradiation with 3.5 MeV electrons the value $ΔE_a = 0$ is found, whereas for the electron energies of 6 to 27 MeV $ΔE_a > 0$. This agrees with the expected threshold of about 5 MeV for cluster formation by electrons. The $ΔE_a$ values determined as a function of annealing temperature show that the annealing rate is different for different defects. A naive diffusion model is used to estimate the temperature dependencies of the diffusion of the defects in the clusters.
△ Less
Submitted 19 March, 2018;
originally announced March 2018.
-
Characterisation of highly radiation-damaged SiPMs using current measurements
Authors:
E. Garutti,
R. Klanner,
D. Lomidze,
J. Schwandt,
M. Zvolsky
Abstract:
The characterisation of radiation-damaged SiPMs is a major challenge, when the average time between dark counts approaches, or even exceeds, the signal decay time. In this note a collection of formulae is presented, which have been developed and used for the analysis of current measurements for SiPMs in the dark and illuminated by an LED, before and after hadron irradiation. It is shown, how param…
▽ More
The characterisation of radiation-damaged SiPMs is a major challenge, when the average time between dark counts approaches, or even exceeds, the signal decay time. In this note a collection of formulae is presented, which have been developed and used for the analysis of current measurements for SiPMs in the dark and illuminated by an LED, before and after hadron irradiation. It is shown, how parameters like the breakdown voltage, the quenching resistance, the dark-count rate, the reduction of the photo-detection efficiency due to dark counts and the Geiger discharge probability can be estimated from current-voltage measurements. The only additional SiPM parameters needed are the pixel capacitance, the number of pixels and the correlated noise. Central to the method is the concept of the pixel occupancy, the probability of a Geiger discharge in a single pixel during a given time interval, for which the decay time of the SiPM signal has been assumed. As an illustration the formulae are used to characterise a KETEK SiPM before and after irradiation by a fluence of 5E13 cm$^{-2}$ of reactor neutrons for temperatures of -30°C and +20°C, where dark-count rates exceeding 1E11 Hz are observed.
△ Less
Submitted 15 September, 2017;
originally announced September 2017.
-
Neutron irradiation effect on SiPMs up to $Φ_{neq}$ = 5 $\times$ 10$^{14}$ cm$^{-2}$
Authors:
M. Centis Vignali,
E. Garutti,
R. Klanner,
D. Lomidze,
J. Schwandt
Abstract:
Silicon Photo-Multipliers (SiPM) are becoming the photo-detector of choice for increasingly more particle detection applications, from fundamental physics to medical and societal applications. One major consideration for their use at high-luminosity colliders is the radiation damage induced by hadrons, which leads to a dramatic increase of the dark count rate. KETEK SiPMs have been exposed to vari…
▽ More
Silicon Photo-Multipliers (SiPM) are becoming the photo-detector of choice for increasingly more particle detection applications, from fundamental physics to medical and societal applications. One major consideration for their use at high-luminosity colliders is the radiation damage induced by hadrons, which leads to a dramatic increase of the dark count rate. KETEK SiPMs have been exposed to various fluences of reactor neutrons up to $Φ_{neq}$ = 5$\times$10$^{14}$ cm$^{-2}$ (1 MeV equivalent neutrons). Results from the I-V, and C-V measurements for temperatures between $-$30$^\circ$C and $+$30$^\circ$C are presented. We propose a new method to quantify the effect of radiation damage on the SiPM performance. Using the measured dark current the single pixel occupation probability as a function of temperature and excess voltage is determined. From the pixel occupation probability the operating conditions for given requirements can be optimized. The method is qualitatively verified using current measurements with the SiPM illuminated by blue LED light.
△ Less
Submitted 14 September, 2017;
originally announced September 2017.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Determination of the p-spray profile for n+p silicon sensors using a MOSFET
Authors:
E. Fretwurst,
E. Garutti,
R. Klanner,
I. Kopsalis,
J. Schwandt,
M. Weberpals
Abstract:
The standard technique to electrically isolate the $n^+$ implants of segmented silicon sensors fabricated on high-ohmic $p$-type silicon are $p^+$-implants. Although the knowledge of the $p^+$-implant dose and of the do** profile is highly relevant for the understanding and optimisation of sensors, this information is usually not available from the vendors, and methods to obtain it are highly we…
▽ More
The standard technique to electrically isolate the $n^+$ implants of segmented silicon sensors fabricated on high-ohmic $p$-type silicon are $p^+$-implants. Although the knowledge of the $p^+$-implant dose and of the do** profile is highly relevant for the understanding and optimisation of sensors, this information is usually not available from the vendors, and methods to obtain it are highly welcome. The paper presents methods to obtain this information from circular MOSFETs fabricated as test structures on the same wafer as the sensors. Two circular MOSFETs, one with and one without a $p^+$-implant under the gate, are used for this study. They were produced on Magnetic Czochralski silicon doped with $\approx 3.5 \times 10^{12}$ cm$^{-2}$ of boron and $\langle 1 0 0 \, \rangle$ crystal orientation. The drain-source current as function of gate voltage for different back-side voltages is measured at a drain-source voltage of 50 mV in the linear MOSFET region, and the values of threshold voltage and mobility extracted using the standard MOSFET formulae. To determine the bulk do**, the implantation dose and profile from the data, two methods are used, which give compatible results. The do** profile, which varies between $3.5 \times 10^{12}$ cm$^{-3}$ and $2 \times 10^{15}$ cm$^{-3}$ for the MOSFET with $p^+$-implant, is determined down to a distance of a fraction of a $μ$m from the Si-SiO$_2$ interface. The method of extracting the do** profiles is verified using data from a TCAD simulation of the two MOSFETs. The details of the methods and of the problems encountered are discussed.
△ Less
Submitted 28 March, 2017;
originally announced April 2017.
-
On the characterisation of SiPMs from pulse-height spectra
Authors:
V. Chmill,
E. Garutti,
R. Klanner,
M. Nitschke,
J. Schwandt
Abstract:
Methods are developed, which use the pulse-height spectra of SiPMs measured in the dark and illuminated by pulsed light, to determine the pulse shape, the dark-count rate, the gain, the average number of photons initiating a Geiger discharge, the probabilities for prompt cross-talk and after-pulses, as well as the electronics noise and the gain fluctuations between and in pixels. The entire pulse-…
▽ More
Methods are developed, which use the pulse-height spectra of SiPMs measured in the dark and illuminated by pulsed light, to determine the pulse shape, the dark-count rate, the gain, the average number of photons initiating a Geiger discharge, the probabilities for prompt cross-talk and after-pulses, as well as the electronics noise and the gain fluctuations between and in pixels. The entire pulse-height spectra, including the background regions in-between the peaks corresponding to different number of Geiger discharges, are described by single functions. As a demonstration, the model is used to characterise a KETEK SiPM with 4382 pixels of 15 μm x 15 μm area for voltages between 2.5 and 8 V above the breakdown voltage at 20°C. The results are compared to other methods of characterising SiPMs. Finally, examples are given, how the complete description of the pulse-eight spectra can be used to optimise the operating voltage of SiPMs, and a method for an in-situ calibration and monitoring of SiPMs, suited for large-scale applications, is proposed.
△ Less
Submitted 21 February, 2017; v1 submitted 5 September, 2016;
originally announced September 2016.
-
Study of the breakdown voltage of SiPMs
Authors:
V. Chmill,
E. Garutti,
R. Klanner,
M. Nitschke,
J. Schwandt
Abstract:
The breakdown behaviour of SiPMs (Silicon PhotoMultiplier) with pixel sizes of 15$\times $15, 25$\times $25, 50$\times $50, and 100$\times $100 $μ$m$^2$, manufactured by KETEK, has been investigated. From the current-voltage characteristics measured with and without illumination by LED light of 470 nm wavelength, the current-breakdown voltage, $V_I$, and from linear fits of the voltage dependence…
▽ More
The breakdown behaviour of SiPMs (Silicon PhotoMultiplier) with pixel sizes of 15$\times $15, 25$\times $25, 50$\times $50, and 100$\times $100 $μ$m$^2$, manufactured by KETEK, has been investigated. From the current-voltage characteristics measured with and without illumination by LED light of 470 nm wavelength, the current-breakdown voltage, $V_I$, and from linear fits of the voltage dependence of the SiPM gain, measured by recording pulse-area spectra, the gain-breakdown voltage, $V_G$, have been obtained. The voltage dependence of the Geiger-breakdown probability was determined from the fraction of zero photoelectron events with LED illumination. By comparing the results to a model calculation, the photodetection-breakdown voltage, $V_{PD}$, has been determined. Within experimental uncertainties, $V_I$ and $V_{PD}$ are equal and independent of pixel size. For $V_G$, a dependence on pixel size is observed. The difference $V_I - V_G$ is about 1 V for the SiPM with 15 $μ$m pixels, decreases with pixel size and is compatible with zero for the SiPM with 100 $μ$m pixels.
△ Less
Submitted 4 May, 2016;
originally announced May 2016.
-
The influence of edge effects on the determination of the do** profile of silicon pad diodes
Authors:
M. Hufschmidt,
E. Fretwurst,
E. Garutti,
R. Klanner,
I. Kopsalis,
J. Schwandt
Abstract:
Edge effects for square p+n pad diodes with guard rings, fabricated on high-ohmic silicon, are investigated. Using capacitance-voltage measurements of two pad diodes with different areas, the planar and the edge contributions to the diode capacitance are determined separately. It is shown that the do** concentration derived from the capacitance-voltage measurements with and without edge correcti…
▽ More
Edge effects for square p+n pad diodes with guard rings, fabricated on high-ohmic silicon, are investigated. Using capacitance-voltage measurements of two pad diodes with different areas, the planar and the edge contributions to the diode capacitance are determined separately. It is shown that the do** concentration derived from the capacitance-voltage measurements with and without edge corrections differ significantly. After the edge correction, the bulk do** of the pad diodes is found to be uniform within +/- 1.5%. The voltage dependence of the edge capacitance is compared to the predictions of two simple models.
△ Less
Submitted 3 May, 2016;
originally announced May 2016.
-
Enabling Technologies for Silicon Microstrip Tracking Detectors at the HL-LHC
Authors:
C. Barth,
C. A. Betancourt,
I. Bloch,
F. Bögelspacher,
W. de Boer,
M. Daniels,
A. Dierlamm,
R. Eber,
G. Eckerlin,
D. Eckstein,
T. Eichhorn,
J. Erfle,
L. Feld,
E. Garutti,
I. -M. Gregor,
M. Guthoff,
F. Hartmann,
M. Hauser,
U. Husemann,
K. Jakobs,
A. Junkes,
W. Karpinski,
K. Klein,
S. Kuehn,
H. Lacker
, et al. (16 additional authors not shown)
Abstract:
While the tracking detectors of the ATLAS and CMS experiments have shown excellent performance in Run 1 of LHC data taking, and are expected to continue to do so during LHC operation at design luminosity, both experiments will have to exchange their tracking systems when the LHC is upgraded to the high-luminosity LHC (HL-LHC) around the year 2024. The new tracking systems need to operate in an env…
▽ More
While the tracking detectors of the ATLAS and CMS experiments have shown excellent performance in Run 1 of LHC data taking, and are expected to continue to do so during LHC operation at design luminosity, both experiments will have to exchange their tracking systems when the LHC is upgraded to the high-luminosity LHC (HL-LHC) around the year 2024. The new tracking systems need to operate in an environment in which both the hit densities and the radiation damage will be about an order of magnitude higher than today. In addition, the new trackers need to contribute to the first level trigger in order to maintain a high data-taking efficiency for the interesting processes. Novel detector technologies have to be developed to meet these very challenging goals. The German groups active in the upgrades of the ATLAS and CMS tracking systems have formed a collaborative "Project on Enabling Technologies for Silicon Microstrip Tracking Detectors at the HL-LHC" (PETTL), which was supported by the Helmholtz Alliance "Physics at the Terascale" during the years 2013 and 2014. The aim of the project was to share experience and to work together on key areas of mutual interest during the R&D phase of these upgrades. The project concentrated on five areas, namely exchange of experience, radiation hardness of silicon sensors, low mass system design, automated precision assembly procedures, and irradiations. This report summarizes the main achievements.
△ Less
Submitted 28 April, 2016;
originally announced April 2016.
-
Resistive Plate Chamber Digitization in a Hadronic Shower Environment
Authors:
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
J. Apostolakis,
G. Folger,
C. Grefe,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
D. Boumediene,
C. Carloganu,
V. Français,
G. Cho,
D-W. Kim,
S. C. Lee,
W. Park,
S. Vallecorsa,
S. Cauwenbergh,
M. Tytgat,
A. **ault,
N. Zaganidis,
E. Brianne,
A. Ebrahimi
, et al. (103 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, e…
▽ More
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, electrons and pions of different energies at the CERN Super Proton Synchrotron. To be able to study the performance of such a calorimeter in future experiments it is important to ensure reliable simulation of its response. In this paper we present our prototype simulation performed with GEANT4 and the digitization procedure achieved with an algorithm called SimDigital. A detailed description of this algorithm is given and the methods to determinate its parameters using muon tracks and electromagnetic showers are explained. The comparison with hadronic shower data shows a good agreement up to 50 GeV. Discrepancies are observed at higher energies. The reasons for these differences are investigated.
△ Less
Submitted 15 April, 2016;
originally announced April 2016.
-
DHCAL with Minimal Absorber: Measurements with Positrons
Authors:
The CALICE Collaboration,
B. Freund,
C. Neubüser,
J. Repond,
J. Schlereth,
L. Xia,
A. Dotti,
C. Grefe,
V. Ivantchenko,
J. Berenguer Antequera,
E. Calvo Alamillo,
M. -C. Fouz,
J. Marin,
J. Puerta-Pelayo,
A. Verdugo,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
C. Günter,
O. Hartbrich,
B. Hermberg,
A. Irles,
F. Krivan,
K. Krüger
, et al. (78 additional authors not shown)
Abstract:
In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on…
▽ More
In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.
△ Less
Submitted 4 March, 2016;
originally announced March 2016.
-
Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter
Authors:
The CALICE Collaboration,
G. Eigen,
T. Price,
N. K. Watson,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
J. -Y. Hostachy,
L. Morin,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
C. Günter,
O. Hartbrich,
B. Hermberg
, et al. (135 additional authors not shown)
Abstract:
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test be…
▽ More
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics lists from Geant4 version 9.6. The parameters extracted from data and simulated samples are compared for the two types of hadrons. The response to pions and the ratio of the non-electromagnetic to the electromagnetic calorimeter response, h/e, are estimated using the extrapolation and decomposition of the longitudinal profiles.
△ Less
Submitted 15 March, 2016; v1 submitted 27 February, 2016;
originally announced February 2016.
-
First results of the CALICE SDHCAL technological prototype
Authors:
V. Buridon,
C. Combaret,
L. Caponetto,
R. Eté,
G. Garillot,
G. Grenier,
R. Han,
J. C. Ianigro,
R. Kieffer,
I. Laktineh,
N. Lumb,
H. Mathez,
L. Mirabito,
A. Petrukhin,
A. Steen,
J. Berenguer Antequera,
E. Calvo Alamillo,
M. -C. Fouz,
J. Marin,
J. Puerta-Pelayo,
A. Verdugo,
E. Cortina Gil,
S. Mannai,
S. Cauwenbergh,
M. Tytgat
, et al. (96 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadronic Calorimeter (SDHCAL) prototype, built in 2011, was exposed to beams of hadrons, electrons and muons in two short periods in 2012 on two different beam lines of the CERN SPS. The prototype with its 48 active layers, made of Glass Resistive Plate Chambers and their embedded readout electronics, was run in triggerless and power-pulsing mode. The performance of the SDH…
▽ More
The CALICE Semi-Digital Hadronic Calorimeter (SDHCAL) prototype, built in 2011, was exposed to beams of hadrons, electrons and muons in two short periods in 2012 on two different beam lines of the CERN SPS. The prototype with its 48 active layers, made of Glass Resistive Plate Chambers and their embedded readout electronics, was run in triggerless and power-pulsing mode. The performance of the SDHCAL during the test beam was found to be very satisfactory with an efficiency exceeding 90% for almost all of the 48 active layers. A linear response (within 5%) and a good energy resolution are obtained for a large range of hadronic energies (5-80GeV) by applying appropriate calibration coefficients to the collected data for both the Digital (Binary) and the Semi-Digital (Multi-threshold) modes of the SDHCAL prototype. The Semi-Digital mode shows better performance at energies exceeding 30GeV
△ Less
Submitted 20 March, 2016; v1 submitted 6 February, 2016;
originally announced February 2016.
-
Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter
Authors:
The CALICE collaboration,
M. Chefdeville,
Y. Karyotakis,
J. Repond,
J. Schlereth,
L. Xia,
G. Eigen,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
N. Alipour Tehrani,
J. Apostolakis,
D. Dannheim,
K. Elsener,
G. Folger,
C. Grefe,
V. Ivantchenko,
M. Killenberg,
W. Klempt,
E. van der Kraaij,
L. Linssen,
A. -I. Lucaci-Timoce,
A. Münnich,
S. Poss,
A. Ribon
, et al. (158 additional authors not shown)
Abstract:
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolutio…
▽ More
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.
△ Less
Submitted 11 December, 2015; v1 submitted 2 September, 2015;
originally announced September 2015.
-
Trap** in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
Authors:
W. Adam,
T. Bergauer,
M. Dragicevic,
M. Friedl,
R. Fruehwirth,
M. Hoch,
J. Hrubec,
M. Krammer,
W. Treberspurg,
W. Waltenberger,
S. Alderweireldt,
W. Beaumont,
X. Janssen,
S. Luyckx,
P. Van Mechelen,
N. Van Remortel,
A. Van Spilbeeck,
P. Barria,
C. Caillol,
B. Clerbaux,
G. De Lentdecker,
D. Dobur,
L. Favart,
A. Grebenyuk,
Th. Lenzi
, et al. (663 additional authors not shown)
Abstract:
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi…
▽ More
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trap** rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trap** rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trap** rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.
-
Characterization studies of Silicon Photomultipliers and crystals matrices for a novel time of flight PET detector
Authors:
Etiennette Auffray,
Faraah Ben Mimoun Bel Hadj,
Daniele Cortinovis,
Katayoun Doroud,
Erika Garutti,
Paul Lecoq,
Zheng Liu,
Rosana Martinez,
Marco Paganoni,
Marco Pizzichemi,
Alessandro Silenzi,
Chen Xu,
Milan Zvolský
Abstract:
This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration aims to integrate Time-Of-Flight PET with ultrasound endoscopy in a novel multimodal device, capable to support the development of new biomarkers for prostate…
▽ More
This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration aims to integrate Time-Of-Flight PET with ultrasound endoscopy in a novel multimodal device, capable to support the development of new biomarkers for prostate and pancreatic tumors. The detector consists in two parts: a PET head mounted on an ultrasound probe and an external PET plate. The challenging goal of 1 mm spatial resolution for the PET image requires a detector with small crystal size, and therefore high channel density: 4096 LYSO crystals individually readout by Silicon Photomultipliers (SiPM) make up the external plate. The quality and properties of these components must be assessed before the assembly. The dark count rate, gain, breakdown voltage and correlated noise of the SiPMs are measured, while the LYSO crystals are evaluated in terms of light yield and energy resolution. In order to effectively reduce the noise in the PET image, high time resolution for the gamma detection is mandatory. The Coincidence Time Resolution (CTR) of all the SiPMs assembled with crystals is measured, and results show a value close to the demanding goal of 200 ps FWHM. The light output is evaluated for every channel for a preliminary detector calibration, showing an average of about 1800 pixels fired on the SiPM for a 511 keV interaction. Finally, the average energy resolution at 511 keV is about 13 %, enough for effective Compton rejection.
△ Less
Submitted 17 January, 2015;
originally announced January 2015.
-
Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
L. Xia,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh,
G. C. Blazey,
A. Dyshkant,
K. Francis,
J. G. R. Lima,
R. Salcido,
V. Zutshi,
F. Salvatore,
K. Kawagoe,
Y. Miyazaki,
Y. Sudo
, et al. (147 additional authors not shown)
Abstract:
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simul…
▽ More
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.
△ Less
Submitted 15 March, 2015; v1 submitted 8 December, 2014;
originally announced December 2014.
-
Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
J. Schlereth,
L. Xia,
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
G. Eigen,
Y. Mikami,
T. Price,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
C. Cârloganu,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh
, et al. (127 additional authors not shown)
Abstract:
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable ove…
▽ More
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.
△ Less
Submitted 8 May, 2015; v1 submitted 26 November, 2014;
originally announced November 2014.
-
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters J. Repond,
J. Schlereth,
L. Xia E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki J. Apostolakis,
S. Arfaoui,
M. Benoit
, et al. (188 additional authors not shown)
Abstract:
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is m…
▽ More
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.
△ Less
Submitted 21 July, 2014; v1 submitted 25 April, 2014;
originally announced April 2014.
-
Influence of X-ray Irradiation on the Properties of the Hamamatsu Silicon Photomultiplier S10362-11-050C
Authors:
Chen Xu,
Robert Klanner,
Erika Garutti,
Wolf-Lukas Hellweg
Abstract:
We have investigated the effects of X-ray irradiation to doses of 0, 200 Gy, 20 kGy, 2 MGy, and 20 MGy on the Hamamatsu silicon-photomultiplier (SiPM) S10362-11-050C. The SiPMs were irradiated without applied bias voltage. From current-voltage, capacitance/conductance-voltage, -frequency, pulse-shape, and pulse-area measurements, the SiPM characteristics below and above breakdown voltage were dete…
▽ More
We have investigated the effects of X-ray irradiation to doses of 0, 200 Gy, 20 kGy, 2 MGy, and 20 MGy on the Hamamatsu silicon-photomultiplier (SiPM) S10362-11-050C. The SiPMs were irradiated without applied bias voltage. From current-voltage, capacitance/conductance-voltage, -frequency, pulse-shape, and pulse-area measurements, the SiPM characteristics below and above breakdown voltage were determined. Significant changes of some SiPM parameters are observed. Up to a dose of 20 kGy the performance of the SiPMs is hardly affected by X-ray radiation damage. For doses of 2 and 20 MGy the SiPMs operate with hardly any change in gain, but with a significant increase in dark-count rate and cross-talk probability.
△ Less
Submitted 11 June, 2014; v1 submitted 11 April, 2014;
originally announced April 2014.
-
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
Authors:
CALICE Collaboration,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon
, et al. (169 additional authors not shown)
Abstract:
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measur…
▽ More
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.
△ Less
Submitted 11 June, 2014; v1 submitted 15 November, 2013;
originally announced November 2013.
-
Shower development of particles with momenta from 1 to 10 GeV in the CALICE Scintillator-Tungsten HCAL
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada
, et al. (194 additional authors not shown)
Abstract:
Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain hig…
▽ More
Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain high-energy showers, while allowing a compact size for the surrounding solenoid.
A fine-grained calorimeter prototype with tungsten absorber plates and scintillator tiles read out by silicon photomultipliers was built and exposed to particle beams at CERN. Results obtained with electrons, pions and protons of momenta up to 10 GeV are presented in terms of energy resolution and shower shape studies. The results are compared with several GEANT4 simulation models in order to assess the reliability of the Monte Carlo predictions relevant for a future experiment at CLIC.
△ Less
Submitted 13 January, 2014; v1 submitted 14 November, 2013;
originally announced November 2013.
-
Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter
Authors:
CALICE Collaboration,
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson
, et al. (184 additional authors not shown)
Abstract:
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angul…
▽ More
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angular distribution of identified track segments are compared to GEANT4 simulations with several different shower models. Track segments also provide the possibility for in-situ calibration of highly granular calorimeters.
△ Less
Submitted 29 July, 2013; v1 submitted 30 May, 2013;