-
Performance of the LHCb Vertex Locator
Authors:
LHCb VELO Group,
R. Aaij,
A. Affolder,
K. Akiba,
M. Alexander,
S. Ali,
R. B. Appleby,
M. Artuso,
A. Bates,
A. Bay,
O. Behrendt,
J. Benton,
M. van Beuzekom,
P. M. Bjørnstad,
G. Bogdanova,
S. Borghi,
A. Borgia,
T. J. V. Bowcock,
J. van den Brand,
H. Brown,
J. Buytaert,
O. Callot,
J. Carroll,
G. Casse,
P. Collins
, et al. (79 additional authors not shown)
Abstract:
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stabi…
▽ More
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented in FPGAs are described. The system performance is fully characterised. The sensors have a signal to noise ratio of approximately 20 and a best hit resolution of 4 microns is achieved at the optimal track angle. The typical detector occupancy for minimum bias events in standard operating conditions in 2011 is around 0.5%, and the detector has less than 1% of faulty strips. The proximity of the detector to the beam means that the inner regions of the n+-on-n sensors have undergone space-charge sign inversion due to radiation damage. The VELO performance parameters that drive the experiment's physics sensitivity are also given. The track finding efficiency of the VELO is typically above 98% and the modules have been aligned to a precision of 1 micron for translations in the plane transverse to the beam. A primary vertex resolution of 13 microns in the transverse plane and 71 microns along the beam axis is achieved for vertices with 25 tracks. An impact parameter resolution of less than 35 microns is achieved for particles with transverse momentum greater than 1 GeV/c.
△ Less
Submitted 10 September, 2014; v1 submitted 30 May, 2014;
originally announced May 2014.
-
Radiation damage in the LHCb Vertex Locator
Authors:
A. Affolder,
K. Akiba,
M. Alexander,
S. Ali,
M. Artuso,
J. Benton,
M. van Beuzekom,
P. M. Bjørnstad,
G. Bogdanova,
S. Borghi,
T. J. V. Bowcock,
H. Brown,
J. Buytaert,
G. Casse,
P. Collins,
S. De Capua,
D. Dossett,
L. Eklund,
C. Farinelli,
J. Garofoli,
M. Gersabeck,
T. Gershon,
H. Gordon,
J. Harrison,
V. Heijne
, et al. (26 additional authors not shown)
Abstract:
The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately $\rm{45 \times 10^{12}\,1\,MeV}$ neutron equivalent ($\rm{1\,MeV\,n_{eq}}$). At the op…
▽ More
The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately $\rm{45 \times 10^{12}\,1\,MeV}$ neutron equivalent ($\rm{1\,MeV\,n_{eq}}$). At the operational sensor temperature of approximately $-7\,^{\circ}\rm{C}$, the average rate of sensor current increase is $18\,\upmu\rm{A}$ per $\rm{fb^{-1}}$, in excellent agreement with predictions. The silicon effective bandgap has been determined using current versus temperature scan data after irradiation, with an average value of $E_{g}=1.16\pm0.03\pm0.04\,\rm{eV}$ obtained. The first observation of n-on-n sensor type inversion at the LHC has been made, occurring at a fluence of around $15 \times 10 ^{12}$ of $1\,\rm{MeV\,n_{eq}}$. The only n-on-p sensors in use at the LHC have also been studied. With an initial fluence of approximately $\rm{3 \times 10^{12}\,1\,MeV\,n_{eq}}$, a decrease in the Effective Depletion Voltage (EDV) of around 25\,V is observed, attributed to oxygen induced removal of boron interstitial sites. Following this initial decrease, the EDV increases at a comparable rate to the type inverted n-on-n type sensors, with rates of $(1.43\pm 0.16) \times 10 ^{-12}\,\rm{V} / \, 1 \, \rm{MeV\,n_{eq}}$ and $(1.35\pm 0.25) \times 10 ^{-12}\,\rm{V} / \, 1 \, \rm{MeV\,n_{eq}}$ measured for n-on-p and n-on-n type sensors, respectively. A reduction in the charge collection efficiency due to an unexpected effect involving the second metal layer readout lines is observed.
△ Less
Submitted 21 February, 2013;
originally announced February 2013.
-
Absolute luminosity measurements with the LHCb detector at the LHC
Authors:
The LHCb Collaboration,
R. Aaij,
B. Adeva,
M. Adinolfi,
C. Adrover,
A. Affolder,
Z. Ajaltouni,
J. Albrecht,
F. Alessio,
M. Alexander,
G. Alkhazov,
P. Alvarez Cartelle,
A. A. Alves Jr,
S. Amato,
Y. Amhis,
J. Anderson,
R. B. Appleby,
O. Aquines Gutierrez,
F. Archilli,
L. Arrabito,
A. Artamonov,
M. Artuso,
E. Aslanides,
G. Auriemma,
S. Bachmann
, et al. (549 additional authors not shown)
Abstract:
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-prot…
▽ More
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.
△ Less
Submitted 11 January, 2012; v1 submitted 13 October, 2011;
originally announced October 2011.
-
Charged Particle Tracking with the Timepix ASIC
Authors:
Kazuyoshi Akiba,
Marina Artuso,
Ryan Badman,
Alessandra Borgia,
Richard Bates,
Florian Bayer,
Martin van Beuzekom,
Jan Buytaert,
Enric Cabruja,
Michael Campbell,
Paula Collins,
Michael Crossley,
Raphael Dumps,
Lars Eklund,
Daniel Esperante,
Celeste Fleta,
Abraham Gallas,
Miriam Gandelman,
Justin Garofoli,
Marco Gersabeck,
Vladimir V. Gligorov,
Hamish Gordon,
Erik H. M. Heijne,
Veerle Heijne,
Daniel Hynds
, et al. (17 additional authors not shown)
Abstract:
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was u…
▽ More
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was used to evaluate in detail the performance of two Timepix hybrid pixel assemblies; a standard planar 300 micron thick sensor, and 285 micron thick double sided 3D sensor. This paper describes a detailed charge calibration study of the pixel devices, which allows the true charge to be extracted, and reports on measurements of the charge collection characteristics and Landau distributions. The planar sensor achieved a best resolution of 4.0 micron for angled tracks, and resolutions of between 4.4 and 11 micron for perpendicular tracks, depending on the applied bias voltage. The double sided 3D sensor, which has significantly less charge sharing, was found to have an optimal resolution of 9.0 micron for angled tracks, and a resolution of 16.0 micron for perpendicular tracks. Based on these studies it is concluded that the Timepix ASIC shows an excellent performance when used as a device for charged particle tracking.
△ Less
Submitted 14 June, 2011; v1 submitted 14 March, 2011;
originally announced March 2011.