-
Projected background and sensitivity of AMoRE-II
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (81 additional authors not shown)
Abstract:
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located ap…
▽ More
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located approximately 1000 meters deep in Jeongseon, Korea. The goal of AMoRE-II is to reach up to $T^{0νββ}_{1/2}$ $\sim$ 6 $\times$ 10$^{26}$ years, corresponding to an effective Majorana mass of 15 - 29 meV, covering all the inverted mass hierarchy regions. To achieve this, the background level of the experimental configurations and possible background sources of gamma and beta events should be well understood. We have intensively performed Monte Carlo simulations using the GEANT4 toolkit in all the experimental configurations with potential sources. We report the estimated background level that meets the 10$^{-4}$counts/(keV$\cdot$kg$\cdot$yr) requirement for AMoRE-II in the region of interest (ROI) and show the projected half-life sensitivity based on the simulation study.
△ Less
Submitted 13 June, 2024;
originally announced June 2024.
-
Characteristics of a matrix proportional counter with circular anodes
Authors:
R. A. Etezov,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
A. Kh. Khokonov,
V. V. Kuzminov,
S. I. Panasenko,
S. S Ratkevich
Abstract:
The construction of a butt-end multicell matrix proportional counter (MMPC) is presented in the work. Each cell is a butt-end proportional counter with a 5 mm cathode diameter and 0.8 mm circular anode diameter. In the example of the $3\times3$ matrix, it is shown that the gas multiplication of the central cell depends on the potentials at the anodes of the peripheral cells, the drift electrode, t…
▽ More
The construction of a butt-end multicell matrix proportional counter (MMPC) is presented in the work. Each cell is a butt-end proportional counter with a 5 mm cathode diameter and 0.8 mm circular anode diameter. In the example of the $3\times3$ matrix, it is shown that the gas multiplication of the central cell depends on the potentials at the anodes of the peripheral cells, the drift electrode, the forming rings, and the surrounding metal parts of the structure. The amplitude characteristics were measured when the MMPC was filled with mixtures of 96.3\% Ar + 3.7\% Xe and 90\% Ar + 10\% CH$_4$ at pressures of 620 Torr and 62 Torr. The calibration was carried out with $α$-particles and $γ$-quanta from a $^{238}$Pu source. For photons with energies of 7.5 keV, a resolution of 26\% was obtained. It is shown that, based on MMPC, it is possible to fabricate recording surfaces of arbitrary configuration.
△ Less
Submitted 4 January, 2022;
originally announced January 2022.
-
$^{222}$Rn content variations at ground and underground conditions
Authors:
R. A. Etezov,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. M. Gezhaev,
V. V. Kazalov,
A. Kh. Khokonov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
The activity of $^{222}$Rn and its daughter isotopes was measured in the air of several underground laboratories of the Baksan Neutrino Observatory at various distances from the entrance. The measurements were carried out with the help of the cylindrical ionionization air chamber. We found that the radon content in the ventilated airflow within the measurement accuracy does not depend on the dista…
▽ More
The activity of $^{222}$Rn and its daughter isotopes was measured in the air of several underground laboratories of the Baksan Neutrino Observatory at various distances from the entrance. The measurements were carried out with the help of the cylindrical ionionization air chamber. We found that the radon content in the ventilated airflow within the measurement accuracy does not depend on the distance travelled along the adit. In addition, we observed that the radon content increases abruptly in those locations where underground gases and water are released. As a result, we review various mechanisms of air enrichment with radon. We also outline our research methodology and present the results of our measurements of radon release from the rocky walls of the underground laboratory. Finally, we present the results of the measurements of the radon content of various ground and underground water sources.
△ Less
Submitted 9 January, 2022; v1 submitted 28 October, 2021;
originally announced October 2021.
-
Recent advancements of the experiment to search for $2K$-capture in $^{124}$Xe using a Large Low-background Proportional Counter
Authors:
O. D. Petrenko,
I. D. Fedorets,
A. M. Gangapshev,
Yu. M. Garilyuk,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
A new method for correcting the charge signal from the large proportional counter is proposed. The correction method makes it possible to take into account the loss of primary ionization electrons in the presence of weakly increasing micro impurities of electronegative gases during long-term measurements. It allows increasing the efficiency of the selection of useful events and thereby increasing…
▽ More
A new method for correcting the charge signal from the large proportional counter is proposed. The correction method makes it possible to take into account the loss of primary ionization electrons in the presence of weakly increasing micro impurities of electronegative gases during long-term measurements. It allows increasing the efficiency of the selection of useful events and thereby increasing the sensitivity to $2\nu2K$-decay in $^{124}$Xe at the level of $2\times10^{22}$ from over six years of measurements using a large proportional counter. Analysis of the calibration data, taking into account the new method for correcting the energy release in the detector, made it possible to register events from double $K$ photoionization by a single photon.
△ Less
Submitted 6 October, 2021;
originally announced October 2021.
-
Improving Calibration of the Large Low-Background Proportional Counter
Authors:
O. D. Petrenko,
A. M. Gangapshev,
Yu. M. Garilyuk,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva
Abstract:
The study of low-yield effects requires not only good quality of the original data but also puts high requirements for their processing procedures to increase the efficiency of the selection of useful events. The exploiting of the large cylindrical proportional counter's electrostatic topology allows improving the extrapolation of information about the primary ionization of a multipoint event. Lon…
▽ More
The study of low-yield effects requires not only good quality of the original data but also puts high requirements for their processing procedures to increase the efficiency of the selection of useful events. The exploiting of the large cylindrical proportional counter's electrostatic topology allows improving the extrapolation of information about the primary ionization of a multipoint event. Long-term calibration measurements with an external $^{109}$Cd-source allowed the development of a new method for analyzing the pulse shape from a sizeable proportional counter. Optimized analysis of the current's pulse shape from the electron cloud of primary ionization in the counter improved the resolution and energy calibration. As a result, the efficiency of selecting useful events was increased by 25\%.
△ Less
Submitted 15 October, 2020;
originally announced October 2020.
-
Modeling of a MeV-scale Particle Detector Based on Organic Liquid Scintillator
Authors:
Yu. M. Malyshkin,
A. M. Gangapshev,
V. N. Gavrin,
T. V. Ibragimova,
M. M. Kochkarov,
V. V. Kazalov,
D. Yu. Kudrin,
V. V. Kuzminov,
B. K. Lubsandorzhiev,
G. Ya. Novikova,
V. B. Petkov,
A. Yu. Sidorenkov,
N. A. Ushakov,
E. P. Veretenkin,
D. M. Voronin,
E. A. Yanovich
Abstract:
The detectors based on the liquid scintillator (LS) monitored by an array of photo-multiplier tubes (PMT) are often used in low energy experiments such as neutrino oscillation studies and search for dark matter. Detectors of this kind operate in an energy range spanning from hundreds of keV to a few GeV providing a few percent resolution at energies above 1 MeV and allowing to observe fine spectra…
▽ More
The detectors based on the liquid scintillator (LS) monitored by an array of photo-multiplier tubes (PMT) are often used in low energy experiments such as neutrino oscillation studies and search for dark matter. Detectors of this kind operate in an energy range spanning from hundreds of keV to a few GeV providing a few percent resolution at energies above 1 MeV and allowing to observe fine spectral features. This article gives a brief overview of relevant physical processes and introduces a new universal simulation tool LSMC (Liquid Scintillator Monte Carlo) for simulation of LS-based detectors equipped with PMT arrays. This tool is based on the Geant4 framework and provides supplementing functionality for ease of configuration and comprehensive output. The usage of LSMC is illustrated by modeling and optimization of a compact detector prototype currently being built at Baksan Neutrino Observatory.
△ Less
Submitted 7 September, 2019;
originally announced September 2019.
-
First Results from the AMoRE-Pilot neutrinoless double beta decay experiment
Authors:
V. Alenkov,
H. W. Bae,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun,
D. M. Chernyak,
J. S. Choe,
S. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. M. Gezhaev,
V. D. Grigoryeva,
V. I. Gurentsov,
O. Gylova,
C. Ha,
D. H. Ha
, et al. (84 additional authors not shown)
Abstract:
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-de…
▽ More
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-depleted calcium and $^{100}$Mo-enriched molybdenum ($^{48\textrm{depl}}$Ca$^{100}$MoO$_4$). The simultaneous detection of heat(phonon) and scintillation (photon) signals is realized with high resolution metallic magnetic calorimeter sensors that operate at milli-Kelvin temperatures. This stage of the project is carried out in the Yangyang underground laboratory at a depth of 700 m. We report first results from the AMoRE-Pilot $0νββ$ search with a 111 kg$\cdot$d live exposure of $^{48\textrm{depl}}$Ca$^{100}$MoO$_4$ crystals. No evidence for $0νββ$ decay of $^{100}$Mo is found, and a upper limit is set for the half-life of 0$νββ$ of $^{100}$Mo of $T^{0ν}_{1/2} > 9.5\times10^{22}$ y at 90% C.L.. This limit corresponds to an effective Majorana neutrino mass limit in the range $\langle m_{ββ}\rangle\le(1.2-2.1)$ eV.
△ Less
Submitted 7 May, 2019; v1 submitted 22 March, 2019;
originally announced March 2019.
-
TAU-4 installation intended for long-term monitoring of a half-life value of the $^{212}$Po
Authors:
E. N. Alexeev,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. M. Gezhaev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
O. D. Petrenko,
S. S. Ratkevich
Abstract:
Description of the TAU-4 installation intended for long-term monitoring of the half-life value $T_{1/2}$ of the $^{212}$Po is presented. Natural thorium used as a source of the mother's chain. The methods of measurement and data processing are described. The comparative results of short test measurements carried out in the ground (680 h) and underground (564 h) laboratories are given. Averaged val…
▽ More
Description of the TAU-4 installation intended for long-term monitoring of the half-life value $T_{1/2}$ of the $^{212}$Po is presented. Natural thorium used as a source of the mother's chain. The methods of measurement and data processing are described. The comparative results of short test measurements carried out in the ground (680 h) and underground (564 h) laboratories are given. Averaged value $T_{1/2}$ =$294.09\pm 0.07$ ns of the $^{212}$Po half-life has been found for the ground level data set similar one for the underground data set. The solar-daily variations with amplitudes $A_{So}=(11.7\pm 5.2)\times10^{-4}$ for the ground data and $A_{So}=(7.5\pm 4.1)\times10^{-4}$ for the underground one were found in a series of $τ$ values.
△ Less
Submitted 12 December, 2018;
originally announced December 2018.
-
The background simulation of experiment for searching of $2\nu2K$ capture in Xe-124
Authors:
V. V. Kazalov,
A. M. Gangapshev,
Yu. M. Gavrilyuk,
V. V. Kuzminov,
S. I. Panasenko,
O. D. Petrenko,
S. S. Ratkevich,
D. A. Tekueva
Abstract:
We describe the Monte Carlo (MC) simulation package of the `2K-CAPTURE' setup and discuss the agreement of its output with data. The `2K-CAPTURE' MC simulates the energy loss of particles in detector and components of the passive shield and generates the resulting response in working volume large proportional counter (LPC). The simulation accounts for absorption, reemission, and scattering of both…
▽ More
We describe the Monte Carlo (MC) simulation package of the `2K-CAPTURE' setup and discuss the agreement of its output with data. The `2K-CAPTURE' MC simulates the energy loss of particles in detector and components of the passive shield and generates the resulting response in working volume large proportional counter (LPC). The simulation accounts for absorption, reemission, and scattering of both photons and neutrons and tracks them until they either are absorbed. The algorithm proceeds with a detailed simulation of the electronics chain. The MC is tuned using data collected with radioactive calibration source deployed in the internal channel of the installation. The simulation reproduces the energy response of the detector corresponding to distribution of the generated pointwise clusters of a charge of primary ionization in LPC.
△ Less
Submitted 11 December, 2018;
originally announced December 2018.
-
2K(2ν)-Capture in Xe-124: Results of Data Processing for an Exposure of 37.7 kg x day
Authors:
Yu. M. Gavriljuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva
Abstract:
The results of the experimental search for two-neutrino $2K$-capture in $^{124}$Xe with a large copper proportional counter obtained by processing the data for an exposure of 37.7 kg$\times$day are presented. The experimental setup is located at the Underground Low-Background Laboratory of the Baksan Neutrino Observatory at a depth of 4900 m w.e. The combination of methods of selection of useful s…
▽ More
The results of the experimental search for two-neutrino $2K$-capture in $^{124}$Xe with a large copper proportional counter obtained by processing the data for an exposure of 37.7 kg$\times$day are presented. The experimental setup is located at the Underground Low-Background Laboratory of the Baksan Neutrino Observatory at a depth of 4900 m w.e. The combination of methods of selection of useful signals with a unique set of characteristics and the event topology taken into account allowed us to suppress the background in the energy region of interest. A new half-life limit for $2K(2ν)$-capture in $^{124}$Xe was determined: T$_{1/2}\geq7.7\cdot10^{21}$ yrs (90\%
C.L.).
△ Less
Submitted 8 June, 2018;
originally announced June 2018.
-
Technical Design Report for the AMoRE $0νββ$ Decay Search Experiment
Authors:
V. Alenkov,
P. Aryal,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun D. M. Chernyak,
J. Choi,
S. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. M. Gezhaev,
V. I. Gurentsov,
D. H Ha,
I. S. Hahn,
J. H. Jang,
E. J. Jeon,
H. S. Jo
, et al. (65 additional authors not shown)
Abstract:
The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillati…
▽ More
The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillation light produced in ultra-pure \Mo[100]-enriched and \Ca[48]-depleted calcium molybdate ($\mathrm{^{48depl}Ca^{100}MoO_4}$) crystals that are located in a deep underground laboratory in Korea. The \mohundred nuclide was chosen for this \zeronubb decay search because of its high $Q$-value and favorable nuclear matrix element. Tests have demonstrated that \camo crystals produce the brightest scintillation light among all of the molybdate crystals, both at room and at cryogenic temperatures. $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals are being operated at milli-Kelvin temperatures and read out via specially developed metallic-magnetic-calorimeter (MMC) temperature sensors that have excellent energy resolution and relatively fast response times. The excellent energy resolution provides good discrimination of signal from backgrounds, and the fast response time is important for minimizing the irreducible background caused by random coincidence of two-neutrino double-beta decay events of \mohundred nuclei. Comparisons of the scintillating-light and phonon yields and pulse shape discrimination of the phonon signals will be used to provide redundant rejection of alpha-ray-induced backgrounds. An effective Majorana neutrino mass sensitivity that reaches the expected range of the inverted neutrino mass hierarchy, i.e., 20-50 meV, could be achieved with a 200~kg array of $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals operating for three years.
△ Less
Submitted 18 December, 2015;
originally announced December 2015.
-
Study of the characteristics of SiPMs matrix as a photosensor for the scintillation detectors
Authors:
I. M. Dzaparova,
A. M. Gangapshev,
Yu. M. Gavrilyuk,
V. B. Petkov,
A. V. Sergeev,
V. I. Volchenko,
S. P. Yakimenko,
A. F. Yanin
Abstract:
The matrices formed of silicon photomultipliers (SiPMs) are very promising photosensors for the scintillation detectors. The use of SiPM matrices with appropriate optical collector gives, in principle, a possibility to do a snapshot of glowing track of charged particle traversing a scintillator. The prototype of such scintillation detector is under development now in INR RAS. The preliminary resul…
▽ More
The matrices formed of silicon photomultipliers (SiPMs) are very promising photosensors for the scintillation detectors. The use of SiPM matrices with appropriate optical collector gives, in principle, a possibility to do a snapshot of glowing track of charged particle traversing a scintillator. The prototype of such scintillation detector is under development now in INR RAS. The preliminary results of characterization study of the matrix ArrayC-60035-64P-PCB (SensL company) for the prototype of such detector are presented.
△ Less
Submitted 18 December, 2015;
originally announced December 2015.
-
Characteristics of a thermal neutrons scintillation detector with the [ZnS(Ag)+$^6$LiF] at different conditions of measurements
Authors:
V. V. Alekseenko,
I. R. Barabanov,
R. A. Etezov,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. M. Gezhaev,
V. V. Kazalov,
A. Kh. Khokonov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
A construction of a thermal neutron testing detector with a thin [ZnS(Ag)+$^6$LiF] scintillator is described. Results of an investigation of sources of the detector pulse origin and the pulse features in a ground and underground conditions are presented. Measurements of the scintillator own background, registration efficiency and a neutron flux at different objects of the BNO INR RAS were performe…
▽ More
A construction of a thermal neutron testing detector with a thin [ZnS(Ag)+$^6$LiF] scintillator is described. Results of an investigation of sources of the detector pulse origin and the pulse features in a ground and underground conditions are presented. Measurements of the scintillator own background, registration efficiency and a neutron flux at different objects of the BNO INR RAS were performed. The results are compared with the ones measured by the $^3$He proportional counter.
△ Less
Submitted 30 October, 2015;
originally announced October 2015.
-
Results of measurements of an environment neutron background at BNO INR RAS objects with the helium proportional counter
Authors:
V. V. Alekseenko,
I. R. Barabanov,
R. A. Etezov,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. M. Gezhaev,
V. V. Kazalov,
A. Kh. Khokonov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
A method of measurements of the environmental neutron background at the Baksan Neutrino Observatory of the INR RAS are described. Measurements were done by using of a proportional counter filled with mixture of Ar(2 at)+$^3$He(4 at). The results obtained at the surface and the underground laboratory of the BNO INR RAS are presented. It is shown that a neutron background in the underground laborato…
▽ More
A method of measurements of the environmental neutron background at the Baksan Neutrino Observatory of the INR RAS are described. Measurements were done by using of a proportional counter filled with mixture of Ar(2 at)+$^3$He(4 at). The results obtained at the surface and the underground laboratory of the BNO INR RAS are presented. It is shown that a neutron background in the underground laboratory at the 4900 m w.e. depth is decreased by $\sim 260$ times without any special shield in a comparison with the Earth surface. A neutron flux density in the 5-1323.5~cm air height region is constant within the determination error and equal to $(7.1\pm0.1_{\rm{stat}}\pm0.3_{\rm{syst}})\times10^{-3}$ s$^{-1}\cdot$cm$^{-2}$.
△ Less
Submitted 29 October, 2015; v1 submitted 17 October, 2015;
originally announced October 2015.
-
High-resolution ion pulse ionization chamber with air filling for the Rn-222 decays detection
Authors:
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. M. Gezhaev,
R. A. Etezov,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva,
S. P. Yakimenko
Abstract:
The construction and characteristics of the cylindrical ion pulse ionization chamber (CIPIC) with a working volume of 3.2 L are described. The chamber is intended to register alpha-particles from the $^{222}$Rn and its daughter's decays in the filled air sample. The detector is less sensitive to electromagnetic pick-ups and mechanical noises. The digital pulse processing method is proposed to impr…
▽ More
The construction and characteristics of the cylindrical ion pulse ionization chamber (CIPIC) with a working volume of 3.2 L are described. The chamber is intended to register alpha-particles from the $^{222}$Rn and its daughter's decays in the filled air sample. The detector is less sensitive to electromagnetic pick-ups and mechanical noises. The digital pulse processing method is proposed to improve the energy resolution of the ion pulse ionization chamber. An energy resolution of 1.6% has been achieved for the 5.49 MeV alpha-line. The dependence of the energy resolution on high voltage and working media pressure has been investigated and the results are presented.
△ Less
Submitted 18 August, 2015;
originally announced August 2015.
-
The study of the thermal neutron flux in the deep underground laboratory DULB-4900
Authors:
V. V. Alekseenko,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. M. Gezhaev,
D. D. Dzhappuev,
V. V. Kazalov,
A. U. Kudzhaev,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva,
S. P. Yakimenko,
Yu. V. Sten'kin
Abstract:
We report on the study of thermal neutron flux using monitors based on mixture of ZnS(Ag) and LiF enriched with a lithium-6 isotope at the deep underground laboratory DULB-4900 at the Baksan Neutrino Observatory. An annual modulation of thermal neutron flux in DULB-4900 is observed. Experimental evidences were obtained of correlation between the long-term thermal neutron flux variations and the ab…
▽ More
We report on the study of thermal neutron flux using monitors based on mixture of ZnS(Ag) and LiF enriched with a lithium-6 isotope at the deep underground laboratory DULB-4900 at the Baksan Neutrino Observatory. An annual modulation of thermal neutron flux in DULB-4900 is observed. Experimental evidences were obtained of correlation between the long-term thermal neutron flux variations and the absolute humidity of the air in laboratory. The amplitude of the modulation exceed 5\% of total neutron flux.
△ Less
Submitted 24 July, 2015; v1 submitted 20 July, 2015;
originally announced July 2015.
-
Search for 2K(2ν)-capture of Xe-124
Authors:
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva,
S. P. Yakimenko
Abstract:
The results of a search for two neutrino mode of double K-capture of Xe-124 using a large copper low-background proportional counter are presented. Data collected during 3220 hours of measurements with 58.6 g of $^{124}$Xe provides us to a new limit on the half-life of Xe-124 regarding 2K-capture at the level: T_{1/2} >= 2.0*10^{21} years at a 90\% confidence level.
The results of a search for two neutrino mode of double K-capture of Xe-124 using a large copper low-background proportional counter are presented. Data collected during 3220 hours of measurements with 58.6 g of $^{124}$Xe provides us to a new limit on the half-life of Xe-124 regarding 2K-capture at the level: T_{1/2} >= 2.0*10^{21} years at a 90\% confidence level.
△ Less
Submitted 16 July, 2015;
originally announced July 2015.
-
The origin of the background radioactive isotope Xe-127 in the sample of Xe enriched in Xe-124
Authors:
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva,
S. P. Yakimenko
Abstract:
The results of investigation of Xe-127 radioactive isotope production in the xenon sample enriched in Xe-124, Xe-126, Xe-128 are presented. The isotope is supposed to be the source of the background events in the low-background experiment on search for 2K-capture of Xe-124. In this work we consider two channels of Xe-127 production: the neutron knock-out from Xe-128 nucleus by cosmogenic muons and…
▽ More
The results of investigation of Xe-127 radioactive isotope production in the xenon sample enriched in Xe-124, Xe-126, Xe-128 are presented. The isotope is supposed to be the source of the background events in the low-background experiment on search for 2K-capture of Xe-124. In this work we consider two channels of Xe-127 production: the neutron knock-out from Xe-128 nucleus by cosmogenic muons and the neutron capture by Xe-126 nucleus. For the first channel the upper limit of the cross section of Xe-127 production was found to be sigma >= 0.007 barn at 95\% C.L. For the second channel the value obtained for the cross section was found to be equal to sigma =(2.74+-0.4) barn, which coincides well, within the statistical error, with reference value.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
Results of a search for daily and annual variations of the Po-214 half-life at the two year observation period
Authors:
E. N. Alexeyev,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
The brief description of installation TAU-2 intended for long-term monitoring of the half-life value $τ$ ($τ_{1/2}$) of the $^{214}$Po is presented. The methods of measurement and processing of collected data are reported. The results of analysis of time series values $τ$ with different time step are presented. Total of measurement time was equal to 590 days. Averaged value of the $^{214}$Po half-…
▽ More
The brief description of installation TAU-2 intended for long-term monitoring of the half-life value $τ$ ($τ_{1/2}$) of the $^{214}$Po is presented. The methods of measurement and processing of collected data are reported. The results of analysis of time series values $τ$ with different time step are presented. Total of measurement time was equal to 590 days. Averaged value of the $^{214}$Po half-life was obtained $τ=163.46\pm0.04$ $μ$s. The annual variation with an amplitude $A=(8.9\pm2.3)\cdot10^{-4}$, solar-daily variation with an amplitude $A_{So}=(7.5\pm1.2)\cdot10^{-4}$, lunar-daily variation with an amplitude $A_L=(6.9\pm2.0)\cdot10^{-4}$ and sidereal-daily variation with an amplitude $A_S=(7.2\pm1.2)\cdot10^{-4}$ were found in a series of $τ$ values. The maximal values of amplitude are observed at the moments when the projections of the installation Earth location velocity vectors toward the source of possible variation achieve its maximal magnitudes.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.
-
First result of the experimental search for the 9.4 keV solar axion reactions with Kr-83 in the copper proportional counter
Authors:
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. V. Derbin,
V. V. Kazalov,
H. J. Kim,
Y. D. Kim,
V. V. Kobychev,
V. V. Kuzminov,
Luqman Ali,
V. N. Muratova,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Semenov,
D. A. Tekueva,
S. P. Yakimenko,
E. V. Unzhakov
Abstract:
The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches Russian Academy of Science. It is assumed that axions are created in the Sun during M1-transition between the first thermally excited level at 9.4 keV and the ground state in Kr-83. The experiment is based on axion detection via resonant absorption process by the…
▽ More
The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches Russian Academy of Science. It is assumed that axions are created in the Sun during M1-transition between the first thermally excited level at 9.4 keV and the ground state in Kr-83. The experiment is based on axion detection via resonant absorption process by the same nucleus in the detector. The big copper proportional counter filled with krypton is used to detect signals from axions. The experimental setup is situated in the deep underground low background laboratory. No evidence of axion detection were found after the 26.5 days data collection. Resulting new upper limit on axion mass is m_{A} < 130 eV at 95% C.L.
△ Less
Submitted 6 May, 2014;
originally announced May 2014.
-
Sources of the systematic errors in measurements of Po-214 decay half-life time variations at the Baksan deep underground experiments
Authors:
E. N. Alexeyev,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
The design changes of the Baksan low-background TAU-1 and TAU-2 set-ups allowed to improve a sensitivity of Po-214 half-life (τ) measurements up to the 2.5 x 10^{-4} are described. Different possible sources of systematic errors influencing on the $τ$-value are studed. An annual variation of Po-214 half-life time measurements with an amplitude of A=(6.9 \pm 3) x 10^{-4} and a phase of (φ=93 \pm 10…
▽ More
The design changes of the Baksan low-background TAU-1 and TAU-2 set-ups allowed to improve a sensitivity of Po-214 half-life (τ) measurements up to the 2.5 x 10^{-4} are described. Different possible sources of systematic errors influencing on the $τ$-value are studed. An annual variation of Po-214 half-life time measurements with an amplitude of A=(6.9 \pm 3) x 10^{-4} and a phase of (φ=93 \pm 10) days was found in a sequence of the week-collected τ-values obtained from the TAU-2 data sample with total duration of 480 days. 24 hours' variation of the τ-value measurements with an amplitude of A=(10.0 \pm 2.6) x 10^{-4} and phase of (φ=1 \pm 0.5) hours was found in a solar day 1 hour step τ-value sequence formed from the same data sample. It was found that the Po-214 half-life averaged at 480 days is equal to (163.45 \pm 0.04) mks.
△ Less
Submitted 23 April, 2014;
originally announced April 2014.
-
First result of the experimental search for the 2K-capture of Xe-124 with the copper proportional counter
Authors:
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva,
S. P. Yakimenko
Abstract:
First result of experiment for searching of 2K-capture of Xe-124 with the large-volume copper proportional counter is given. The 12 litre sample with 63.3% (44 g) of Xe-124 was used in measurements. The limit on the half-life of Xe-124 with regard to 2K(2ν)-capture for the ground state of Te-124 has been found: T_{1/2} > 4.67x10^{20} y (90% C.L.). A sample with volume 52 L comprising of Xe-124 (10…
▽ More
First result of experiment for searching of 2K-capture of Xe-124 with the large-volume copper proportional counter is given. The 12 litre sample with 63.3% (44 g) of Xe-124 was used in measurements. The limit on the half-life of Xe-124 with regard to 2K(2ν)-capture for the ground state of Te-124 has been found: T_{1/2} > 4.67x10^{20} y (90% C.L.). A sample with volume 52 L comprising of Xe-124 (10.6 L - 58.6 g) and Xe-126 (14.1 L - 79.3 g) will used at the next step of the experiment to increase a sensitivity of 2K-caption of Xe-124 registration. In this case sensitivity to the investigated process will be at the level of S=1.46 x 10^{21} y (90% C.L.) for 1 year measurement.
△ Less
Submitted 22 April, 2014;
originally announced April 2014.
-
Working characteristics of the New Low-Background Laboratory (DULB-4900, Baksan Neutrino Observatory)
Authors:
Ju. M. Gavriljuk,
A. M. Gangapshev,
A. M. Gezhaev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
S. P. Yakimenko
Abstract:
A concise technical characteristic of a new low-background laboratory DULB-4900 of the BNO INR RAS is presented. The technique and the results of background measurements in the Hall, ordinary box and low-background box are presented. Rn-222 contamination in the laboratory air has been measured by direct detection of gamma-radiation of its daughter Bi-214 distributed over the volume of the low-back…
▽ More
A concise technical characteristic of a new low-background laboratory DULB-4900 of the BNO INR RAS is presented. The technique and the results of background measurements in the Hall, ordinary box and low-background box are presented. Rn-222 contamination in the laboratory air has been measured by direct detection of gamma-radiation of its daughter Bi-214 distributed over the volume of the low-background box. The results of the data analysis are presented.
△ Less
Submitted 28 April, 2012;
originally announced April 2012.
-
Pulse Shape Analysis and Identification of Multipoint Events in a Large-Volume Proportional Counter in an Experimental Search for 2K Capture Kr-78
Authors:
Yu. M. Gavriljuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
S. P. Yakimenko
Abstract:
A pulse shape analysis algorithm and a method for suppressing the noise component of signals from a large copper proportional counter in the experiment aimed at searching for 2K capture of Kr-78 are described. These signals correspond to a compound event with different numbers of charge clusters due to from primary ionization is formed by these signals. A technique for separating single- and multi…
▽ More
A pulse shape analysis algorithm and a method for suppressing the noise component of signals from a large copper proportional counter in the experiment aimed at searching for 2K capture of Kr-78 are described. These signals correspond to a compound event with different numbers of charge clusters due to from primary ionization is formed by these signals. A technique for separating single- and multipoint events and determining the charge in individual clusters is presented. Using the Daubechies wavelets in multiresolutional signal analysis, it is possible to increase the sensitivity and the resolution in extraction of multipoint events in the detector by a factor of 3-4.
△ Less
Submitted 12 June, 2010; v1 submitted 28 November, 2009;
originally announced November 2009.
-
Measurement of surface alpha-acrivity of different samples with ion pulse ionization chamber
Authors:
Yu. M. Gavriljuk,
V. N. Gavrin,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
The construction of an ion pulse ionization chamber aimed at measuring ultra-low levels of surface alpha-activity of different samples is described. The results of measurement carried out with alpha-source and copper samples and light-reflecting film VM2000 are presented.
The construction of an ion pulse ionization chamber aimed at measuring ultra-low levels of surface alpha-activity of different samples is described. The results of measurement carried out with alpha-source and copper samples and light-reflecting film VM2000 are presented.
△ Less
Submitted 16 November, 2007;
originally announced November 2007.