Skip to main content

Showing 1–6 of 6 results for author: Gandilo, N N

Searching in archive physics. Search in all archives.
.
  1. arXiv:2103.07936  [pdf, other

    astro-ph.IM physics.ins-det

    Anti-reflection Coated Vacuum Window for the Primordial Inflation Polarization ExploreR (PIPER) balloon-borne instrument

    Authors: Rahul Datta, David T. Chuss, Joseph Eimer, Thomas Essinger-Hileman, Natalie N. Gandilo, Kyle Helson, Alan J. Kogut, Luke Lowe, Paul Mirel, Karwan Rostem, Marco Sagliocca, Danielle Sponseller, Eric R. Switzer, Peter A. Taraschi, Edward J. Wollack

    Abstract: Measuring the faint polarization signal of the cosmic microwave background (CMB) not only requires high optical throughput and instrument sensitivity but also control over systematic effects. Polarimetric cameras or receivers used in this setting often employ dielectric vacuum windows, filters, or lenses to appropriately prepare light for detection by cooled sensor arrays. These elements in the op… ▽ More

    Submitted 14 March, 2021; originally announced March 2021.

    Journal ref: Review of Scientific Instruments 92, 035111 (2021)

  2. arXiv:2002.05771  [pdf, other

    astro-ph.IM physics.ins-det

    Particle response of antenna-coupled TES arrays: results from SPIDER and the lab

    Authors: B. Osherson, J. P. Filippini, J. Fu, R. V. Gramillano, R. Gualtieri, E. C. Shaw, P. A. R. Ade, M. Amiri, S. J. Benton, J. J. Bock, J. R. Bond, S. A. Bryan, H. C. Chiang, C. R. Contaldi, O. Dore, A. A. Fraisse, A. E. Gambrel, N. N. Gandilo, J. E. Gudmundsson, M. Halpern, J. Hartley, M. Hasselfield, G. Hilton, W. Holmes, V. V. Hristov , et al. (23 additional authors not shown)

    Abstract: Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers… ▽ More

    Submitted 13 February, 2020; originally announced February 2020.

    Comments: 9 pages, 6 figures, Proceedings of the 18th International Workshop on Low Temperature Detectors

  3. arXiv:1711.04169  [pdf, other

    astro-ph.IM physics.ins-det

    280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter

    Authors: A. S. Bergman, P. A. R. Ade, S. Akers, M. Amiri, J. A. Austermann, J. A. Beall, D. T. Becker, S. J. Benton, J. J. Bock, J. R. Bond, S. A. Bryan, H. C. Chiang, C. R. Contaldi, R. S Domagalski, O. Doré, S. M. Duff, A. J. Duivenvoorden, H. K. Eriksen, M. Farhang, J. P. Filippini, L. M. Fissel, A. A. Fraisse, K. Freese, M. Galloway, A. E. Gambrel , et al. (54 additional authors not shown)

    Abstract: We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mod… ▽ More

    Submitted 22 November, 2017; v1 submitted 11 November, 2017; originally announced November 2017.

  4. arXiv:1506.06953  [pdf, other

    astro-ph.IM astro-ph.CO physics.ins-det

    The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat

    Authors: J. E. Gudmundsson, P. A. R. Ade, M. Amiri, S. J. Benton, J. J. Bock, J. R. Bond, S. A. Bryan, H. C. Chiang, C. R. Contaldi, B. P. Crill, O. Doré, J. P. Filippini, A. A. Fraisse, A. Gambrel, N. N. Gandilo, M. Hasselfield, M. Halpern, G. C. Hilton, W. Holmes, V. V. Hristov, K. D. Irwin, W. C. Jones, Z. Kermish, C. J. MacTavish, P. V. Mason , et al. (18 additional authors not shown)

    Abstract: We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid he… ▽ More

    Submitted 11 September, 2015; v1 submitted 23 June, 2015; originally announced June 2015.

    Comments: 15 pgs, 17 figs

  5. arXiv:1407.1881  [pdf, ps, other

    astro-ph.IM physics.ins-det

    Design and construction of a carbon fiber gondola for the SPIDER balloon-borne telescope

    Authors: J. D. Soler, P. A. R. Ade, M. Amiri, S. J. Benton, J. J. Bock, J. R. Bond, S. A. Bryan, C. Chiang, C. C. Contaldi, B. P. Crill, O. P. Doré, M. Farhang, J. P. Filippini, L. M. Fissel, A. A. Fraisse, A. E. Gambrel, N. N. Gandilo, S. Golwala, J. E. Gudmundsson, M. Halpern, M. Hasselfield, G. C. Hilton, W. A. Holmes, V. V. Hristov, K. D. Irwin , et al. (22 additional authors not shown)

    Abstract: We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne in… ▽ More

    Submitted 7 July, 2014; originally announced July 2014.

    Comments: 16 pages, 11 figures. Presented at SPIE Ground-based and Airborne Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume 9145

  6. arXiv:1106.2507  [pdf, other

    astro-ph.IM physics.ins-det

    Thermal architecture for the SPIDER flight cryostat

    Authors: J. E. Gudmundsson, P. A. R. Ade, M. Amiri, S. J. Benton, R. Bihary, J. J. Bock, J. R. Bond, J. A. Bonetti, S. A. Bryan, H. C. Chiang, C. R. Contaldi, B. P. Crill, D. O'Dea, M. Farhang, J. P. Filippini, L. M. Fissel, N. N. Gandilo, S. R. Golwala, M. Halpern, M. Hasselfield, K. R. Helson, G. Hilton, W. Holmes, V. V. Hristov, K. D. Irwin , et al. (18 additional authors not shown)

    Abstract: We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooli… ▽ More

    Submitted 13 June, 2011; originally announced June 2011.

    Comments: 11 pages, 4 figures; as published in the conference proceedings for SPIE Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy V (2010)

    Journal ref: Proceedings of the SPIE, Volume 7741, pp. 77411M-77411M-11 (2010)