Characterization of VUV4 SiPM for Liquid Argon Detector
Authors:
L. Wang,
M. Y. Guan,
H. J. Qin,
C. Guo,
X. L. Sun,
C. G. Yang,
Q. Zhao,
J. C. Liu,
P. Zhang,
Y. P. Zhang,
W. X. Xiong,
Y. T. Wei,
Y. Y. Gan,
J. J. Li
Abstract:
Particle detectors based on liquid argon are now recognised as an attractive technology for dark matter direct detection and coherent elastic neutrino-nucleus scattering measurement. A program using a dual-phase liquid argon detector with a fiducial mass of 200~kg to detect coherent elastic neutrino-nucleus scattering at Taishan Nuclear Power Plant has been proposed. SiPMs will be used as the phot…
▽ More
Particle detectors based on liquid argon are now recognised as an attractive technology for dark matter direct detection and coherent elastic neutrino-nucleus scattering measurement. A program using a dual-phase liquid argon detector with a fiducial mass of 200~kg to detect coherent elastic neutrino-nucleus scattering at Taishan Nuclear Power Plant has been proposed. SiPMs will be used as the photon sensor because of their high radio-purity and high photon detection efficiency. S13370-6050CN SiPM, made by Hamamatsu, is a candidate for the detector. In this paper, the characterisation of S13370-6050CN SiPM, including the cross talk and after pulse probabilities at liquid argon temperature and the temperature dependence of break down voltage, dark counting rate and relative quantum efficiency were presented.
△ Less
Submitted 12 April, 2021; v1 submitted 11 January, 2021;
originally announced January 2021.
Using $^{22}$Na and $^{83{\rm m}}$Kr to calibrate and study the properties of scintillation in xenon-doped liquid argon
Authors:
Y. Y. Gan,
M. Y. Guan,
Y. P. Zhang,
P. Zhang,
C. G. Yang,
Q. Zhao,
Y. T. Wei,
W. X. Xiong
Abstract:
We have measured the properties of scintillation light in liquid argon doped with xenon concentrations from 165 ppm to 10,010 ppm using a $^{22}$Na source. The energy transfer processes in the xenon-doped liquid argon are discussed in detail, and a new waveform model is established and used to fit the average waveform. The time profile of the scintillation photon in the xenon-doped liquid argon an…
▽ More
We have measured the properties of scintillation light in liquid argon doped with xenon concentrations from 165 ppm to 10,010 ppm using a $^{22}$Na source. The energy transfer processes in the xenon-doped liquid argon are discussed in detail, and a new waveform model is established and used to fit the average waveform. The time profile of the scintillation photon in the xenon-doped liquid argon and of the TPB emission are presented. The quantities of xenon-doped are controlled by a Mass Flow Controller which is calibrated via a Redusial Gas Analyzer to ensure that the xenon concentration is accurate. In addition, a successful test of $^{83{\rm m}}$Kr as a calibration source has been implemented in the xenon-doped liquid argon detector for the first time. By comparing the light yield of the $^{22}$Na and $^{83{\rm m}}$Kr, it can be concluded that the scintillation efficiency is almost same over the range of 41.5 keV to 511 keV.
△ Less
Submitted 25 October, 2020; v1 submitted 3 July, 2020;
originally announced July 2020.