-
Pipeline for Advanced Contrast Enhancement (PACE) of chest X-ray in evaluating COVID-19 patients by combining bidimensional empirical mode decomposition and CLAHE
Authors:
Giulio Siracusano,
Aurelio La Corte,
Michele Gaeta,
Giuseppe Cicero,
Massimo Chiappini,
Giovanni Finocchio
Abstract:
COVID-19 is a new pulmonary disease which is driving stress to the hospitals due to the large number of cases worldwide. Imaging of lungs can play a key role in monitoring of the healthy status. Non-contrast chest computed tomography (CT) has been used for this purpose, mainly in China, with a significant success. However, this approach cannot be used massively mainly for both high risk and cost a…
▽ More
COVID-19 is a new pulmonary disease which is driving stress to the hospitals due to the large number of cases worldwide. Imaging of lungs can play a key role in monitoring of the healthy status. Non-contrast chest computed tomography (CT) has been used for this purpose, mainly in China, with a significant success. However, this approach cannot be used massively mainly for both high risk and cost and in some countries also because this tool is not extensively available. Alternatively, chest X-ray, although less sensitive than CT-scan, can provide important information about the evolution of pulmonary involvement during the disease, this aspect is very important to verify the response of a patient to treatments. Here, we show how to improve the sensitivity of chest X-ray via a nonlinear post processing tool, named PACE, combining properly fast and adaptive bidimensional empirical mode decomposition and contrast limited adaptive histogram equalization (CLAHE). The results show an enhancement of the image contrast as confirmed by three widely used metrics: (i) contrast improvement index, (ii) entropy, and (iii) measure of enhancement. This improvement gives rise to a detectability of more lung lesions as identified by two radiologists, which evaluate the images separately, and confirmed by CT-scans. Based on our findings this method is proved as a flexible and effective way for medical image enhancement and can be used as a post-processing step for medical image understanding and analysis.
△ Less
Submitted 7 June, 2020;
originally announced June 2020.
-
Sulfur and REE zoning in apatite: The example of the Colli Albani magmatic system
Authors:
Alessandro Fabbrizio,
Mario Gaeta,
Michael R. Carroll,
Maurizio Petrelli
Abstract:
We investigate the distribution of major and trace elements in apatite crystals hosted in granular alkaline rocks composed mainly of leucite and clinopyroxene, representative of the hypabyssal crystallization of a magma body in the Quaternary ultra-potassic Colli Albani Volcanic District (CAVD), which was emplaced into thick limestone units along the Tyrrhenian margin of Italy. Results show that t…
▽ More
We investigate the distribution of major and trace elements in apatite crystals hosted in granular alkaline rocks composed mainly of leucite and clinopyroxene, representative of the hypabyssal crystallization of a magma body in the Quaternary ultra-potassic Colli Albani Volcanic District (CAVD), which was emplaced into thick limestone units along the Tyrrhenian margin of Italy. Results show that the analyzed crystals are the SrO-richest (up to 4.6 wt%) fluorapatite (F =2.6-3.7 wt%) of the Italian alkaline rocks. The strontium enrichment is caused by the lack of other Sr-compatible mineral phases, such as plagioclase, alkali feldspar and melilite, in these leucite- and clinopyroxene-bearing rocks. The studied samples show core-rim zoning with rims enriched in Si, S, and REE whereas the cores are enriched in Ca and P. The LREE-oxides contents of apatite, reaching 4.2 wt%, represent more than 95% of the total REE budget; SiO2 contents range from 1.3 to 3.6 wt%, and SO3 concentrations between 0.6 and 1.4 wt%.
△ Less
Submitted 28 December, 2018;
originally announced December 2018.
-
A data-Oriented based Self-Calibration And Robust chemical-shift encoding by using clusterization (OSCAR) - Theory, Optimization and Clinical Validation in Neuromuscular disorders
Authors:
Giulio Siracusano,
Aurelio La Corte,
Michele Gaeta,
Giovanni Finocchio
Abstract:
Multi-echo Chemical Shift Encoded methods for Fat-Water quantification are growing in clinical use due to their ability to estimate and correct some confounding effects. State of the art CSE water-fat separation approaches rely on a multi-peak fat spectrum with peak frequencies and relative amplitudes kept constant over the entire MRI dataset. However, the latter approximation introduces a systema…
▽ More
Multi-echo Chemical Shift Encoded methods for Fat-Water quantification are growing in clinical use due to their ability to estimate and correct some confounding effects. State of the art CSE water-fat separation approaches rely on a multi-peak fat spectrum with peak frequencies and relative amplitudes kept constant over the entire MRI dataset. However, the latter approximation introduces a systematic error in fat percentage quantification in patients where the differences in lipid chemical composition are significant, such as for neuromuscular disorders, because of the spatial dependence of the peak amplitudes. The present work aims to overcome this limitation by taking advantage of an unsupervised clusterization-based approach offering a reliable criterion to carry out a data-driven segmentation of the input MRI dataset into multiple regions. The idea is to apply the clusterization for partitioning the multi-echo MRI dataset into a finite number of clusters whose internal voxels exhibit similar distance metrics. For each cluster, the estimation of the fat spectral properties are evaluated with a self-calibration technique and finally the fat-water percentages are computed via a non-linear fitting. The method is tested in ad-hoc and public datasets. The overall performance and results in terms of fitting accuracy, robustness and reproducibility are compared with other state-of-the-art CSE algorithms. This approach provides a more accurate and reproducible identification of chemical species, hence fat-water separation, when compared with other calibrated and non-calibrated approaches.
△ Less
Submitted 14 June, 2017;
originally announced June 2017.
-
On the R2* Relaxometry in Complex Multi-Peak Multi-Echo Chemical Shift-Based Water-Fat Quantification: Applications to the Neuromuscular Diseases
Authors:
G. Siracusano,
A. La Corte,
C. Milazzo,
G. P. Anastasi,
G. Finocchio,
M. Gaeta
Abstract:
Purpose: Investigation of the feasibility of the R2* map** techniques by using latest theoretical models corrected for confounding factors and optimized for signal to noise ratio. Theory and Methods: The improvement of the performance of state of the art MRI relaxometry algorithms is challenging because of a non-negligible bias and still unresolved numerical instabilities. Here, R2* map** reco…
▽ More
Purpose: Investigation of the feasibility of the R2* map** techniques by using latest theoretical models corrected for confounding factors and optimized for signal to noise ratio. Theory and Methods: The improvement of the performance of state of the art MRI relaxometry algorithms is challenging because of a non-negligible bias and still unresolved numerical instabilities. Here, R2* map** reconstructions, including complex-fitting with multi-spectral fat-correction by using single-decay (1D) and double-decay (2D) formulation, are studied in order to identify optimal configuration parameters and minimize numerical artifacts. The effects of echo number, echo spacing, and fat/water relaxation model are evaluated through simulated and in-vivo data. We also explore the stability of such models by analyzing the impact of high percentage of fat infiltrations and local transverse relaxation differences among biological species. Results: The main limits of the MRI relaxometry are the presence of bias and the occurrence of artifacts which affect its accuracy. Chemical-shift complex reconstructions R2*-corrected with 1D formulation exhibit a large bias in presence of a significant difference in the relaxation rates of fat and water and with fat concentration larger than 30%. We find that for fat-dominated tissues or in patients affected by iron overload, MRI reconstructions accounting for multi-exponential relaxation time provide accurate R2* measurements and are less prone to numerical artifacts. Conclusions: Complex fitting 2D formulation outperforms the conventional 1D approximation in various diagnostic scenarios. Although it still lacks of numerical stability which requires model enhancement and support from spectroscopy, it offers promising perspectives for the development of relaxometry as a reliable tool to improve tissue characterization and monitoring of neuromuscular disorders.
△ Less
Submitted 8 August, 2016;
originally announced August 2016.