-
The daily modulations and broadband strategy in axion searches. An application with CAST-CAPP detector
Authors:
C. M. Adair,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
A. Belov,
D. Bozicevic,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
W. Chung,
H. Choi,
J. Choi,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. Galan,
A. Gardikiotis
, et al. (38 additional authors not shown)
Abstract:
It has been previously advocated that the presence of the daily and annual modulations of the axion flux on the Earth's surface may dramatically change the strategy of the axion searches. The arguments were based on the so-called Axion Quark Nugget (AQN) dark matter model which was originally put forward to explain the similarity of the dark and visible cosmological matter densities…
▽ More
It has been previously advocated that the presence of the daily and annual modulations of the axion flux on the Earth's surface may dramatically change the strategy of the axion searches. The arguments were based on the so-called Axion Quark Nugget (AQN) dark matter model which was originally put forward to explain the similarity of the dark and visible cosmological matter densities $Ω_{\rm dark}\sim Ω_{\rm visible}$. In this framework, the population of galactic axions with mass $ 10^{-6} {\rm eV}\lesssim m_a\lesssim 10^{-3}{\rm eV}$ and velocity $\langle v_a\rangle\sim 10^{-3} c$ will be accompanied by axions with typical velocities $\langle v_a\rangle\sim 0.6 c$ emitted by AQNs. Furthermore, in this framework, it has also been argued that the AQN-induced axion daily modulation (in contrast with the conventional WIMP paradigm) could be as large as $(10-20)\%$, which represents the main motivation for the present investigation. We argue that the daily modulations along with the broadband detection strategy can be very useful tools for the discovery of such relativistic axions. The data from the CAST-CAPP detector have been used following such arguments. Unfortunately, due to the dependence of the amplifier chain on temperature-dependent gain drifts and other factors, we could not conclusively show the presence or absence of a dark sector-originated daily modulation. However, this proof of principle analysis procedure can serve as a reference for future studies.
△ Less
Submitted 9 May, 2024;
originally announced May 2024.
-
Search for Dark Matter Axions with CAST-CAPP
Authors:
C. M. Adair,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
A. Belov,
D. Bozicevic,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
W. Chung,
H. Choi,
J. Choi,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. Galan,
A. Gardikiotis
, et al. (39 additional authors not shown)
Abstract:
The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 $μ$eV to 22.47 $μ$eV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a st…
▽ More
The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 $μ$eV to 22.47 $μ$eV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a strong dipole magnet, phase-matched to maximize the detection sensitivity. Here we report on the data acquired for 4124 h from 2019 to 2021. Each cavity is equipped with a fast frequency tuning mechanism of 10 MHz/min between 4.774 GHz and 5.434 GHz. In the present work, we exclude axion-photon couplings for virialized galactic axions down to $g_{aγγ} = 8 \times {10^{-14}}$ $GeV^{-1}$ at the 90% confidence level. The here implemented phase-matching technique also allows for future large-scale upgrades.
△ Less
Submitted 5 November, 2022;
originally announced November 2022.
-
Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector
Authors:
R. Abbott,
A. Abreu,
F. Addesa,
M. Alhusseini,
T. Anderson,
Y. Andreev,
A. Apresyan,
R. Arcidiacono,
M. Arenton,
E. Auffray,
D. Bastos,
L. A. T. Bauerdick,
R. Bellan,
M. Bellato,
A. Benaglia,
M. Benettoni,
R. Bertoni,
M. Besancon,
S. Bharthuar,
A. Bornheim,
E. Brücken,
J. N. Butler,
C. Campagnari,
M. Campana,
R. Carlin
, et al. (174 additional authors not shown)
Abstract:
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about…
▽ More
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3 x 3 x 57 mm$^3$ and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to an MPV energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.
△ Less
Submitted 16 July, 2021; v1 submitted 15 April, 2021;
originally announced April 2021.
-
The Upgrade I of LHCb VELO -- towards an intelligent monitoring platform
Authors:
P. Kopciewicz,
T. Szumlak,
M. Majewski,
K. Akiba,
O. Augusto,
J. Back,
D. S. Bobulska,
G. Bogdanova,
S. Borghi,
T. Bowcock,
J. Buytaert,
E. Lemos Cid,
V. Coco,
P. Collins,
E. Dall'Occo,
K. de Bruyn,
S. de Capua,
F. Dettori,
K. Dreimanis,
D. Dutta,
L. Eklund,
T. Evans,
M. Ferro-Luzzi W. Funk,
L. Meyer Garcia,
O. Boente García
, et al. (41 additional authors not shown)
Abstract:
The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated. In order to increase the trigger yield for purely hadronic channels, the hardware trigger will be removed, and the detector will be read out at 40 MHz. This, in…
▽ More
The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated. In order to increase the trigger yield for purely hadronic channels, the hardware trigger will be removed, and the detector will be read out at 40 MHz. This, in combination with the five-fold increase in luminosity, requires radical changes to LHCb's electronics, and, in some cases, the replacement of entire sub-detectors with state-of-the-art detector technologies. The Vertex Locator (VELO) surrounding the interaction region is used to reconstruct the collision points (primary vertices) and decay vertices of long-lived particles (secondary vertices). The upgraded VELO will be composed of 52 modules placed along the beam axis divided into two retractable halves. The modules will each be equipped with 4 silicon hybrid pixel tiles, each read out by 3 VeloPix ASICs. The total output data rate anticipated for the whole detector will be around 1.6 Tbit/s. The highest occupancy ASICs will have pixel hit rates of approximately 900 Mhit/s, with the corresponding output data rate of 15 Gbit/s. The LHCb upgrade detector will be the first detector to read out at the full LHC rate of 40 MHz. The VELO upgrade will utilize the latest detector technologies to read out at this rate while maintaining the required radiation-hard profile and minimizing the detector material.
△ Less
Submitted 22 July, 2022; v1 submitted 16 June, 2020;
originally announced June 2020.
-
First Results on the Search for Chameleons with the KWISP Detector at CAST
Authors:
S. Arguedas Cuendis,
J. Baier,
K. Barth,
S. Baum,
A. Bayirli,
A. Belov,
H. Bräuninger,
G. Cantatore,
J. M. Carmona,
J. F. Castel,
S. A. Cetin,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. A. García,
A. Gardikiotis,
J. G. Garza,
S. Gninenko,
M. D. Hasinoff,
D. H. H. Hoffmann,
F. J. Iguaz
, et al. (28 additional authors not shown)
Abstract:
We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of…
▽ More
We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of solar chameleons. The displacements are detected by a Michelson interferometer with a homodyne readout scheme. The sensor benefits from the focusing action of the ABRIXAS X-ray telescope installed at CAST, which increases the chameleon flux on the membrane. A mechanical chopper placed between the telescope output and the detector modulates the incoming chameleon stream. We present the results of the solar chameleon measurements taken at CAST in July 2017, setting an upper bound on the force acting on the membrane of $80$~pN at 95\% confidence level. The detector is sensitive for direct coupling to matter $10^4 \leqβ_m \leq 10^8$, where the coupling to photons is locally bound to $β_γ\leq 10^{11}$.
△ Less
Submitted 3 June, 2019;
originally announced June 2019.
-
Improved Search for Solar Chameleons with a GridPix Detector at CAST
Authors:
V. Anastassopoulos,
S. Aune,
K. Barth,
A. Belov,
H. Bräuninger,
G. Cantatore,
J. M. Carmona,
J. F. Castel,
S. A. Cetin,
F. Christensen,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
H. Fischer,
W. Funk,
J. A. García,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis,
T. Geralis
, et al. (44 additional authors not shown)
Abstract:
We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling,…
▽ More
We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling, $β_γ< 5.7\times10^{10}$ for $1<β_\mathrm{m}<10^6$ at 95% C.L. improving our previous results by a factor two and for the first time reaching sensitivity below the solar luminosity bound for tachocline magnetic fields up to $12.5\,\mathrm{T}$.
△ Less
Submitted 8 November, 2018; v1 submitted 31 July, 2018;
originally announced August 2018.
-
aKWISP: investigating short-distance interactions at sub-micron scales
Authors:
G. Cantatore,
V. Anastassopoulos,
S. Cetin,
H. Fischer,
W. Funk,
A Gardikiotis,
D. H. H. Hoffmann,
M. Karuza,
Y. K. Semertzidis,
D. Vitali,
K. Zioutas
Abstract:
The sub-micron range in the field of short distance interactions has yet to be opened to experimental investigation, and may well hold the key to understanding al least part of the dark matter puzzle. The aKWISP (advanced-KWISP) project introduces the novel Double Membrane Interaction Monitor (DMIM), a combined source-sensing device where interaction distances can be as short as 100 nm or even 10…
▽ More
The sub-micron range in the field of short distance interactions has yet to be opened to experimental investigation, and may well hold the key to understanding al least part of the dark matter puzzle. The aKWISP (advanced-KWISP) project introduces the novel Double Membrane Interaction Monitor (DMIM), a combined source-sensing device where interaction distances can be as short as 100 nm or even 10 nm, much below the 1-10 micron distance which is the lower limit encountered by current experimental efforts. aKWISP builds on the technology and the results obtained with the KWISP opto-mechanical force sensor now searching at CAST for the direct coupling to matter of solar chameleons. It will reach the ultimate quantum-limited sensitivity by exploiting an array of technologies, including operation at milli-Kelvin temperatures. Recent suggestions point at short-distance interactions studies as intriguing possibilities for the detection of axions and of new physical phenomena.
△ Less
Submitted 20 March, 2018;
originally announced March 2018.
-
Search for axions in streaming dark matter
Authors:
K. Zioutas,
V. Anastassopoulos,
S. Bertolucci,
G. Cantatore,
S. A. Cetin,
H. Fischer,
W. Funk,
A. Gardikiotis,
D. H. H. Hoffmann,
S. Hofmann,
M. Karuza,
M. Maroudas,
Y. K. Semertzidis,
I. Tkatchev
Abstract:
A new search strategy for the detection of the elusive dark matter (DM) axion is proposed. The idea is based on streaming DM axions, whose flux might get temporally enormously enhanced due to gravitational lensing. This can happen if the Sun or some planet (including the Moon) is found along the direction of a DM stream propagating towards the Earth location. The experimental requirements to the a…
▽ More
A new search strategy for the detection of the elusive dark matter (DM) axion is proposed. The idea is based on streaming DM axions, whose flux might get temporally enormously enhanced due to gravitational lensing. This can happen if the Sun or some planet (including the Moon) is found along the direction of a DM stream propagating towards the Earth location. The experimental requirements to the axion haloscope are a wide-band performance combined with a fast axion rest mass scanning mode, which are feasible. Once both conditions have been implemented in a haloscope, the axion search can continue parasitically almost as before. Interestingly, some new DM axion detectors are operating wide-band by default. In order not to miss the actually unpredictable timing of a potential short duration signal, a network of co-ordinated axion antennae is required, preferentially distributed world-wide. The reasoning presented here for the axions applies to some degree also to any other DM candidates like the WIMPs.
△ Less
Submitted 4 March, 2017;
originally announced March 2017.
-
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
Authors:
The CMS Electromagnetic Calorimeter Group,
P. Adzic,
N. Almeida,
D. Andelin,
I. Anicin,
Z. Antunovic,
R. Arcidiacono,
M. W. Arenton,
E. Auffray,
S. Argiro,
A. Askew,
S. Baccaro,
S. Baffioni,
M. Balazs,
D. Bandurin,
D. Barney,
L. M. Barone,
A. Bartoloni,
C. Baty,
S. Beauceron,
K. W. Bell,
C. Bernet,
M. Besancon,
B. Betev,
R. Beuselinck
, et al. (245 additional authors not shown)
Abstract:
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews t…
▽ More
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.
△ Less
Submitted 21 December, 2009;
originally announced December 2009.
-
Front-End electronics configuration system for CMS
Authors:
P. Gras,
F. Drouhin,
W. Funk,
L. Gross,
D. Vintache
Abstract:
The four LHC experiments at CERN have decided to use a commercial SCADA (Supervisory Control And Data Acquisition) product for the supervision of their DCS (Detector Control System). The selected SCADA, which is therefore used for the CMS DCS, is PVSS II from the company ETM. This SCADA has its own database, which is suitable for storing conventional controls data such as voltages, temperatures…
▽ More
The four LHC experiments at CERN have decided to use a commercial SCADA (Supervisory Control And Data Acquisition) product for the supervision of their DCS (Detector Control System). The selected SCADA, which is therefore used for the CMS DCS, is PVSS II from the company ETM. This SCADA has its own database, which is suitable for storing conventional controls data such as voltages, temperatures and pressures. In addition, calibration data and FE (Front-End) electronics configuration need to be stored. The amount of these data is too large to be stored in the SCADA database [1]. Therefore an external database will be used for managing such data. However, this database should be completely integrated into the SCADA framework, it should be accessible from the SCADA and the SCADA features, e.g. alarming, logging should be benefited from. For prototy**, Oracle 8i was selected as the external database manager. The development of the control system for calibration constants and FE electronics configuration has been done in close collaboration with the CMS tracker group and JCOP (Joint COntrols Project)(1).
(1)The four LHC experiments and the CERN IT/CO group has merged their efforts to build the experiments controls systems and set up the JCOP at the end of December, 1997 for this purpose.
△ Less
Submitted 17 December, 2001;
originally announced December 2001.
-
Design and Operation of Front-End Electronics for the HERA-B Muon Detector
Authors:
M. Buchler,
W. Funk,
A. Gutierrez,
R. F. Harr,
P. E. Karchin,
P. Liu,
S. Nam,
J. G. Shiu,
S. F. Takach,
M. Atiya,
D. Padrazo,
A. Arefiev,
S. Barsuk,
F. Khasanov,
L. Laptin,
V. Tchoudakov,
I. Tichimirov,
M. Titov,
Y. Zaitsev
Abstract:
We have implemented a cost-effective design for the readout electronics of both the anode wires and the cathode pads of large area proportional wire chambers for the HERA-B muon system based on the ASD-08 integrated circuit. To control and monitor the large number of readout channels, we have built a distributed control system based on Philips Semiconductors' I2C bus and microcontrollers. To dat…
▽ More
We have implemented a cost-effective design for the readout electronics of both the anode wires and the cathode pads of large area proportional wire chambers for the HERA-B muon system based on the ASD-08 integrated circuit. To control and monitor the large number of readout channels, we have built a distributed control system based on Philips Semiconductors' I2C bus and microcontrollers. To date we have installed about 10800 channels of muon chambers and electronics. The average single channel noise occupancy is less than 10**-5, and the detectors have been operated with target interaction rates as high as 70 MHz.
△ Less
Submitted 10 December, 1998;
originally announced December 1998.