-
Low-Shapiro hydrostatic reconstruction technique for blood flow simulation in large arteries with varying geometrical and mechanical properties
Authors:
A. R. Ghigo,
O. Delestre,
J. -M. Fullana,
P. -Y. Lagrée
Abstract:
The purpose of this work is to construct a simple, efficient and accurate well-balanced numerical scheme for one-dimensional (1D) blood flow in large arteries with varying geometrical and mechanical properties. As the steady states at rest are not relevant for blood flow, we construct two well-balanced hydrostatic reconstruction techniques designed to preserve low-Shapiro number steady states that…
▽ More
The purpose of this work is to construct a simple, efficient and accurate well-balanced numerical scheme for one-dimensional (1D) blood flow in large arteries with varying geometrical and mechanical properties. As the steady states at rest are not relevant for blood flow, we construct two well-balanced hydrostatic reconstruction techniques designed to preserve low-Shapiro number steady states that may occur in large network simulations. The Shapiro number S h = u/c is the equivalent of the Froude number for shallow water equations and the Mach number for compressible Euler equations. The first is the low-Shapiro hydrostatic reconstruction (HR-LS), which is a simple and efficient method, inspired from the hydrostatic reconstruction technique (HR). The second is the subsonic hydrostatic reconstruction (HR-S), adapted here to blood flow and designed to exactly preserve all subcritical steady states. We systematically compare HR, HR-LS and HR-S in a series of single artery and arterial network numerical tests designed to evaluate their well-balanced and wave-capturing properties. The results indicate that HR is not adapted to compute blood flow in large arteries as it is unable to capture wave reflections and transmissions when large variations of the arteries' geometrical and mechanical properties are considered. On the contrary, HR-S is exactly well-balanced and is the most accurate hydrostatic reconstruction technique. However, HR-LS is able to compute low-Shapiro number steady states as well as wave reflections and transmissions with satisfying accuracy and is simpler and computationally less expensive than HR-S. We therefore recommend using HR-LS for 1D blood flow simulations in large arterial network simulations.
△ Less
Submitted 19 January, 2017;
originally announced January 2017.
-
One-dimensional Arterial Network Model for Bypass Grafts Assessment
Authors:
Arthur Ghigo,
Salam Abou Taam,
Xiaofei Wang,
Pierre-Yves Lagrée,
Jose-Maria Fullana
Abstract:
We propose an arterial network model based on 1D blood hemodynamic equations to study the behavior of different vascular surgical bypass grafts in case of an arterial occlusive pathology: an obliteration or stenosis of the iliac artery. We investigate the performances of three different bypass grafts (Aorto-Femoral, Axillo-Femoral and cross-over Femoral) depending on the degree of obliteration of…
▽ More
We propose an arterial network model based on 1D blood hemodynamic equations to study the behavior of different vascular surgical bypass grafts in case of an arterial occlusive pathology: an obliteration or stenosis of the iliac artery. We investigate the performances of three different bypass grafts (Aorto-Femoral, Axillo-Femoral and cross-over Femoral) depending on the degree of obliteration of the stenosis. Numerical simulations show that all bypass grafts are efficient since we retrieve in all cases the normal hemodynamics in the stenosed region while ensuring at the same time a global healthy circulation. We analyze in particular the Axillo-Femoral bypass graft by performing hundreds of simulations by varying the values of the Young's modulus [0.1--50 MPa] and the radius [0.01--5 cm] of the bypass graft. We show that the Young's modulus and radius of commercial bypass grafts are optimal in terms of hemodynamic considerations. The numerical findings prove that this approach could be used to optimize or plan surgeries for specific patients, to perform parameter's statistics and error propagation evaluations by running extensive simulations, or to characterize numerically specific bypass grafts.
△ Less
Submitted 28 November, 2016;
originally announced November 2016.
-
Modeling rain-driven overland flow: empirical versus analytical friction terms in the shallow water approximation
Authors:
G. Kirstetter,
J. Hu,
O. Delestre,
F. Darboux,
P. -Y. Lagrée,
S. Popinet,
J. -M. Fullana,
C. Josserand
Abstract:
Modeling and simulating overland flow fed by rainfall is a common issue in watershed surface hydrology. Modelers have to choose among various friction models when defining their simulation framework. The purpose of this work is to compare the simulation quality for the Manning, Darcy-Weisbach, and Poiseuille friction models on the simple case of a constant rain on a thin experimental flume. Result…
▽ More
Modeling and simulating overland flow fed by rainfall is a common issue in watershed surface hydrology. Modelers have to choose among various friction models when defining their simulation framework. The purpose of this work is to compare the simulation quality for the Manning, Darcy-Weisbach, and Poiseuille friction models on the simple case of a constant rain on a thin experimental flume. Results show that the usual friction law of Manning is not suitable for this type of flow. The Poiseuille friction model gave the best results both on the flux at the outlet and the velocity and depth profile along the flume. The Darcy-Weisbach model shows good results for laminar flow. Additional testing should be carried out for turbulent cases.
△ Less
Submitted 15 September, 2016;
originally announced September 2016.
-
Linear and nonlinear viscoelastic arterial wall models: application on animals
Authors:
Arthur Ghigo,
Xiao-Fei Wang,
Ricardo Armentano,
Pierre-Yves Lagrée,
Jose-Maria Fullana
Abstract:
This work deals with the viscoelasticity of the arterial wall and its influence on the pulse waves. We describe the viscoelasticity by a non-linear Kelvin-Voigt model in which the coefficients are fitted using experimental time series of pressure and radius measured on a sheep's arterial network. We obtained a good agreement between the results of the nonlinear Kelvin-Voigt model and the experimen…
▽ More
This work deals with the viscoelasticity of the arterial wall and its influence on the pulse waves. We describe the viscoelasticity by a non-linear Kelvin-Voigt model in which the coefficients are fitted using experimental time series of pressure and radius measured on a sheep's arterial network. We obtained a good agreement between the results of the nonlinear Kelvin-Voigt model and the experimental measurements. We found that the viscoelastic relaxation time-defined by the ratio between the viscoelastic coefficient and the Young's modulus-is nearly constant throughout the network. Therefore, as it is well known that smaller arteries are stiffer, the viscoelastic coefficient rises when approaching the peripheral sites to compensate the rise of the Young's modulus, resulting in a higher dam** effect. We incorporated the fitted viscoelastic coefficients in a nonlinear 1D fluid model to compute the pulse waves in the network. The dam** effect of viscoelasticity on the high frequency waves is clear especially at the peripheral sites.
△ Less
Submitted 27 July, 2016;
originally announced July 2016.
-
Droplet migration in a Hele-Shaw cell: Effect of the lubrication film on the droplet dynamics
Authors:
Yue Ling,
Jose-Maria Fullana,
Stéphane Popinet,
Christophe Josserand
Abstract:
Droplet migration in a Hele--Shaw cell is a fundamental multiphase flow problem which is crucial for many microfluidics applications. We focus on the regime at low capillary number and three-dimensional direct numerical simulations are performed to investigate the problem. In order to reduce the computational cost, an adaptive mesh is employed and high mesh resolution is only used near the interfa…
▽ More
Droplet migration in a Hele--Shaw cell is a fundamental multiphase flow problem which is crucial for many microfluidics applications. We focus on the regime at low capillary number and three-dimensional direct numerical simulations are performed to investigate the problem. In order to reduce the computational cost, an adaptive mesh is employed and high mesh resolution is only used near the interface. Parametric studies are performed on the droplet horizontal radius and the capillary number. For droplets with an horizontal radius larger than half the channel height the droplet overfills the channel and exhibits a pancake shape. A lubrication film is formed between the droplet and the wall and particular attention is paid to the effect of the lubrication film on the droplet velocity. The computed velocity of the pancake droplet is shown to be lower than the average inflow velocity, which is in agreement with experimental measurements. The numerical results show that both the strong shear induced by the lubrication film and the three-dimensional flow structure contribute to the low mobility of the droplet. In this low-migration-velocity scenario the interfacial flow in the droplet reference frame moves toward the rear on the top and reverses direction moving to the front from the two side edges. The velocity of the pancake droplet and the thickness of the lubrication film are observed to decrease with capillary number. The droplet velocity and its dependence on capillary number cannot be captured by the classic Hele--Shaw equations, since the depth-averaged approximation neglects the effect of the lubrication film.
△ Less
Submitted 18 May, 2016; v1 submitted 26 January, 2016;
originally announced January 2016.
-
Fluid friction and wall viscosity of the 1D blood flow model
Authors:
Xiao-Fei Wang,
Shohei Nishi,
Mami Matsukawa,
Arthur Ghigo,
Pierre-Yves Lagrée,
Jose-Maria Fullana
Abstract:
We study the behavior of the pulse waves of water into a flexible tube for application to blood flow simulations. In pulse waves both fluid friction and wall viscosity are dam** factors, and difficult to evaluate separately. In this paper, the coefficients of fluid friction and wall viscosity are estimated by fitting a nonlinear 1D flow model to experimental data. In the experimental setup,…
▽ More
We study the behavior of the pulse waves of water into a flexible tube for application to blood flow simulations. In pulse waves both fluid friction and wall viscosity are dam** factors, and difficult to evaluate separately. In this paper, the coefficients of fluid friction and wall viscosity are estimated by fitting a nonlinear 1D flow model to experimental data. In the experimental setup, a distensible tube is connected to a piston pump at one end and closed at another end. The pressure and wall displacements are measured simultaneously. A good agreement between model predictions and experiments was achieved. For amplitude decrease, the effect of wall viscosity on the pulse wave has been shown as important as that of fluid viscosity.
△ Less
Submitted 15 November, 2015;
originally announced November 2015.
-
Droplet in micro-channels: A numerical approach using an adaptive two phase flow solver
Authors:
Jose-Maria Fullana,
Yue Ling,
Stéphane Popinet,
Christophe Josserand
Abstract:
We propose a numerical approach to study the mechanics of a flowing bubble in a constraint micro channel. Using an open source two phase flow solver (Gerris, gfs.sourceforge.net) we compute solutions of the bubble dynamics (i.e. shape and terminal velocity) induced by the interaction between the bubble movement, the Laplace pressure variation, and the lubrication film near the channel wall. Quanti…
▽ More
We propose a numerical approach to study the mechanics of a flowing bubble in a constraint micro channel. Using an open source two phase flow solver (Gerris, gfs.sourceforge.net) we compute solutions of the bubble dynamics (i.e. shape and terminal velocity) induced by the interaction between the bubble movement, the Laplace pressure variation, and the lubrication film near the channel wall. Quantitative and qualitative results are presented and compared against both theory and experimental data for small Capillary numbers. We discuss the technical issues of explicit integration methods on small Capillary numbers computations, and the possibility of adding Van der Walls forces to give a more precise picture of the Droplet-based microfluidic problem.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
Verification and comparison of four numerical schemes for a 1D viscoelastic blood flow model
Authors:
Xiaofei Wang,
Jose-Maria Fullana,
Pierre-Yves Lagrée
Abstract:
A reliable and fast numerical scheme is crucial for the 1D simulation of blood flow in compliant vessels. In this paper, a 1D blood flow model is incorporated with a Kelvin-Voigt viscoelastic arterial wall. This leads to a nonlinear hyperbolic-parabolic system, which is then solved with four numerical schemes, namely: MacCormack, Taylor-Galerkin, MUSCL (monotonic upwind scheme for conservation law…
▽ More
A reliable and fast numerical scheme is crucial for the 1D simulation of blood flow in compliant vessels. In this paper, a 1D blood flow model is incorporated with a Kelvin-Voigt viscoelastic arterial wall. This leads to a nonlinear hyperbolic-parabolic system, which is then solved with four numerical schemes, namely: MacCormack, Taylor-Galerkin, MUSCL (monotonic upwind scheme for conservation law) and local discontinuous Galerkin. The numerical schemes are tested on a single vessel, a simple bifurcation and a network with 55 arteries. The numerical solutions are checked favorably against analytical, semi-analytical solutions or clinical observations. Among the numerical schemes, comparisons are made in four important aspects: accuracy, ability to capture shock-like phenomena, computational speed and implementation complexity. The suitable conditions for the application of each scheme are discussed.
△ Less
Submitted 16 September, 2014; v1 submitted 22 February, 2013;
originally announced February 2013.